Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 28

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Tetrahedral triple-Q magnetic ordering and large spontaneous Hall conductivity in the metallic triangular antiferromagnet Co$$_{1/3}$$TaS$$_{2}$$

Park, P.*; Cho, W.*; Kim, C.*; An, Y.*; Kang, Y.-G.*; Avdeev, M.*; Sibille, R.*; Iida, Kazuki*; Kajimoto, Ryoichi; Lee, K. H.*; et al.

Nature Communications (Internet), 14, p.8346_1 - 8346_9, 2023/12

 Times Cited Count:0 Percentile:0(Multidisciplinary Sciences)

Journal Articles

CSNI leak-before-break benchmark; Summary of phase 1

Tregoning, R.*; Wallace, J.*; Bouydo, A.*; Costa-Garrido, O.*; Dillstr$"o$m, P.*; Duan, X.*; Heckmann, K.*; Kim, Y.-B.*; Kim, Y.*; Kurth-Twombly, E.*; et al.

Transactions of the 26th International Conference on Structural Mechanics in Reactor Technology (SMiRT-26) (Internet), 11 Pages, 2022/07

Fourteen organizations, representing eleven countries, participated in a leak-before-break (LBB) benchmark exercise that compared results from analyses among participating countries and identified the effects of weld residual stress (WRS) and crack morphology on crack opening displacement (COD), critical bending moment (CBM), and leak rate (LR) results. The participants determined whether the initial problem would meet their country's LBB acceptance criteria and then evaluated the effects of crack morphology and WRS for a prescribed crack size, geometry and loading. Six out of fourteen participants indicated that the initial problem met their LBB requirements. In the follow-on tasks, differences among the participant's CBM predictions were principally due to the material properties used in the analysis while the type of failure model chosen contributed much less. Most of the differences in the LR predictions were directly attributable to differences among the COD models, but a portion was attributable to the treatment of crack face pressure (CFP). The benchmark identified several aspects of an LBB analysis that could support a more realistic evaluation.

Journal Articles

Nature of structural instabilities in superconducting Sr$$_3$$Ir$$_4$$Sn$$_{13}$$

Kaneko, Koji; Cheung, Y. W.*; Hu, Y.*; Imai, Masaki*; Tanioku, Yasuaki*; Kanagawa, Hibiki*; Murakawa, Joichi*; Moriyama, Kodai*; Zhang, W.*; Lai, K. T.*; et al.

JPS Conference Proceedings (Internet), 30, p.011032_1 - 011032_6, 2020/03

Journal Articles

Evidence of a structural quantum critical point in (Ca$$_x$$Sr$$_{1-x}$$)$$_3$$Rh$$_4$$Sn$$_{13}$$ from a lattice dynamics study

Cheung, Y. W.*; Hu, Y. J.*; Imai, Masaki*; Tanioku, Yasuaki*; Kanagawa, Hibiki*; Murakawa, Joichi*; Moriyama, Kodai*; Zhang, W.*; Lai, K. T.*; Yoshimura, Kazuyoshi*; et al.

Physical Review B, 98(16), p.161103_1 - 161103_5, 2018/10

 Times Cited Count:19 Percentile:67.24(Materials Science, Multidisciplinary)

Journal Articles

Super-absorbent polymer valves and colorimetric chemistries for time-sequenced discrete sampling and chloride analysis of sweat via skin-mounted soft microfluidics

Kim, S. B.*; Zhang, Y.*; Won, S. M.*; Bandodkar, A. J.*; Sekine, Yurina; Xue, Y.*; Koo, J.*; Harshman, S. W.*; Martin, J. A.*; Park, J. M.*; et al.

Small, 14(12), p.1703334_1 - 1703334_11, 2018/03

 Times Cited Count:98 Percentile:95.52(Chemistry, Multidisciplinary)

Journal Articles

Maximizing $$T_c$$ by tuning nematicity and magnetism in FeSe$$_{1-x}$$S$$_x$$ superconductors

Matsuura, Kohei*; Mizukami, Yuta*; Arai, Yuki*; Sugimura, Yuichi*; Maejima, Naoyuki*; Machida, Akihiko*; Watanuki, Tetsu*; Fukuda, Tatsuo; Yajima, Takeshi*; Hiroi, Zenji*; et al.

Nature Communications (Internet), 8, p.1143_1 - 1143_6, 2017/10

 Times Cited Count:80 Percentile:91.57(Multidisciplinary Sciences)

Journal Articles

Second-order structural transition in (Ca$$_{0.5}$$Sr$$_{0.5}$$)$$_3$$Rh$$_4$$Sn$$_{13}$$

Cheung, Y. W.*; Hu, Y. J.*; Goh, S. K.*; Kaneko, Koji; Tsutsui, Satoshi; Logg, P. W.*; Grosche, F. M.*; Kanagawa, Hibiki*; Tanioku, Yasuaki*; Imai, Masaki*; et al.

Journal of Physics; Conference Series, 807(3), p.032002_1 - 032002_4, 2017/04

BB2016-0329.pdf:0.86MB

 Times Cited Count:5 Percentile:83.59(Physics, Condensed Matter)

Journal Articles

Second-order structural transition in the superconductor La$$_3$$Co$$_4$$Sn$$_{13}$$

Cheung, Y. W.*; Zhang, J. Z.*; Zhu, J. Y.*; Yu, W. C.*; Hu, Y. J.*; Wang, D. G.*; Otomo, Yuka*; Iwasa, Kazuaki*; Kaneko, Koji; Imai, Masaki*; et al.

Physical Review B, 93(24), p.241112_1 - 241112_5, 2016/06

AA2016-0058.pdf:0.95MB

 Times Cited Count:14 Percentile:54.92(Materials Science, Multidisciplinary)

Journal Articles

First neutral beam injection experiments on KSTAR tokamak

Jeong, S. H.*; Chang, D. H.*; Kim, T. S.*; In, S. R.*; Lee, K. W.*; Jin, J. T.*; Chang, D. S.*; Oh, B. H.*; Bae, Y. S.*; Kim, J. S.*; et al.

Review of Scientific Instruments, 83(2), p.02B102_1 - 02B102_3, 2012/02

 Times Cited Count:22 Percentile:68.03(Instruments & Instrumentation)

The first NB (neutral beam) injection system of the KSTAR tokamak was partially completed in 2010 with only 1/3 of its full design capability, and NB heating experiments were carried out during the 2010 KSTAR operation campaign. The ion source is composed of a JAEA bucket plasma generator and a KAERI large multi-aperture accelerator assembly. Before the beam injection experiments, characteristics of the ion source were investigated. A minimum beam divergence angle was 0.8 $$^{circ}$$. The ion species ratio was D$$^{+}$$:D$$_{2}$$$$^{+}$$:D$$_{3}$$$$^{+}$$=75:20:5. The arc efficiency is more than 1.0 A/kW. In the 2010 KSTAR campaign, the deuterium NB power of 0.7-1.5 MW was successfully injected into the KSTAR plasma with the beam energy of 70-90 keV. L-H transitions were observed within a wide range of beam powers relative to a threshold value. In every deuterium NB injection, a burst of D-D neutrons was recorded, and increases in the ion temperature and the plasma stored energy were found.

Journal Articles

Characteristics of the first H-mode discharges in KSTAR

Yoon, S. W.*; Ahn, J.-W.*; Jeon, Y. M.*; Suzuki, Takahiro; Hahn, S. H.*; Ko, W. H.*; Lee, K. D.*; Chung, J. I.*; Nam, Y. U.*; Kim, J.*; et al.

Nuclear Fusion, 51(11), p.113009_1 - 113009_9, 2011/11

 Times Cited Count:33 Percentile:79.01(Physics, Fluids & Plasmas)

Typical ELMy H-mode discharges have been achieved on the KSTAR tokamak with the combined auxiliary heating of NBI and ECRH. The minimum external heating power required is about 1.1 MW at a line-averaged density higher than 1.4$$times$$10$$^{19}$$ m$$^{-3}$$ and a toroidal field of 2 T. There is a clear indication of the increase of the L-H threshold power at densities lower than $$1.4times 10^{19} {rm m}^{-3}$$. The initial analysis of energy confinement time ($$tau$$$$_{E}$$) predicted that $$tau$$$$_{E}$$ was higher than the prediction of multi-machine scaling laws by a factor 1.4-1.6. However, when the contribution of fast ion confinement to the total energy was taken into account, $$tau$$$$_{E}$$ better agreed with the scaling results. A clear increase of electron and ion temperature in the pedestal was observed in the H-mode phase but the core ion temperature did not change significantly. On the other hand, the toroidal rotation also increased over all radii in the H-mode phase. The measured ELM frequency was from 30-50 Hz and the drop of total energy appeared to be less than 5%. Between large ELM spikes, small/grassy ELMs were also identified when mixed heating of NBI and ECRH was applied.

Journal Articles

Arc discharge characteristics of a long pulse ion source for the KSTAR neutral beam injector

Chang, D. H.*; Jeong, S. H.*; Jin, J. T.*; Chang, D. S.*; Kim, T. S.*; Lee, K. W.*; In, S. R.*; Oh, B. H.*; Bae, Y. S.*; Kim, J. S.*; et al.

Journal of the Korean Physical Society, 59(2), p.275 - 280, 2011/08

 Times Cited Count:3 Percentile:27.54(Physics, Multidisciplinary)

A long pulse ion source (LPIS) for the neutral beam injector (NBI) has been developed for the Korea Superconducting Tokamak Advanced Research (KSTAR) superconducting tokamak. The arc discharge characteristics of the ion source were investigated on the first KSTAR neutral beam injector (NBI-1). The ion source consists of a magnetic bucket plasma generator with multi-pole cusp fields and a set of prototype tetrode accelerators with circular apertures. Stable and efficient arc plasmas up to an arc power of 70 kW have been produced by using a constant power-mode operation of the arc power supply. The reliable operation region of the arc discharges has been investigated for various filament heating voltages, arc powers, and amounts of injected deuterium gas.

Journal Articles

Results of beam extraction performance for the KSTAR neutral beam injector

Chang, D. H.*; Jeong, S. H.*; Kim, T. S.*; Lee, K. W.*; In, S. R.*; Jin, J. T.*; Chang, D. S.*; Oh, B. H.*; Bae, Y. S.*; Kim, J. S.*; et al.

Japanese Journal of Applied Physics, 50(6), p.066302_1 - 066302_7, 2011/06

 Times Cited Count:11 Percentile:43.98(Physics, Applied)

A stable ion beam extraction of the LPIS-1 was achieved up to 85 kV/32 A for a 5 s pulse length and 80 kV/25 A for a 14 s pulse length. An optimum beam perveance of 1.15 $$mu$$perv was observed at an acceleration voltage of 60 kV. Neutralization efficiency was measured by a water-flow calorimetry (WFC) method using a calorimeter and the operation of a bending magnet. The full-energy species of ion beams were detected by using the diagnostic method of optical multichannel analyzer (OMA). An arc efficiency of the LPIS was 0.6-1.1 A/kW depending on the operating conditions of arc discharge. A neutral beam power of 1.0 MW must be sufficiently injected into the KSTAR plasmas from the LPIS-1 at a beam energy of 80 keV.

Journal Articles

Development of a plasma generator for a long pulse ion source for neutral beam injectors

Watanabe, Kazuhiro; Dairaku, Masayuki; Tobari, Hiroyuki; Kashiwagi, Mieko; Inoue, Takashi; Hanada, Masaya; Jeong, S. H.*; Chang, D. H.*; Kim, T. S.*; Kim, B. R.*; et al.

Review of Scientific Instruments, 82(6), p.063507_1 - 063507_6, 2011/06

 Times Cited Count:16 Percentile:58.97(Instruments & Instrumentation)

A long pulse plasma generator for neutral beam injectors has been developed. The plasma generator was designed to produce 65 A at 120 keV from a beam extraction area of 12 cm $$times$$ 46 cm. A type of the plasma generator is a multi-cusp plasma generator with SmCo permanent magnets. A long pulse test of the plasma generator was performed at the KSTAR NBI test stand in Korea under the Japan - Korea Fusion collaboration. It was successfully demonstrated of the long pulse operation of the plasma generator for 200 s at an arc discharge power of 70 kW which can produce 65 A beams. Plasma spatial uniformity at the beam extraction area was confirmed to be smaller than $$pm$$ 8% of the deviation from an averaged ion saturation current density. A high arc efficiency of 0.9-1.1 A/kW was obtained at the beam extraction with 73 keV, 41 A for 5 sec. From these experimental studies, a performance of this plasma generator for long pulse ion sources was confirmed.

Journal Articles

Commissioning results of the KSTAR neutral beam system

Bae, Y. S.*; Park, Y. M.*; Kim, J. S.*; Han, W. S.*; Kwak, S. W.*; Chang, Y. B.*; Park, H. T.*; Song, N. H.*; Chang, D. H.*; Jeong, S. H.*; et al.

Proceedings of 23rd IAEA Fusion Energy Conference (FEC 2010) (CD-ROM), 9 Pages, 2011/03

The neutral beam injection (NBI) system is designed to provide the ion heating and current drive for the high performance operation and long pulse operation of the Korean Superconducting Tokamak Advanced Research (KSTAR). The KSTAR NBI consists of two beam lines. Each beam line contains three ion sources of which one ion source has been designed to deliver more than 2.5 MW of deuterium neutral beam power with maximum 120-keV beam energy. Consequently, the final goal of the KSTAR NBI system aims to inject more than 14 MW of deuterium beam power with the two beam lines. According to the planned NBI system, the first NBI system is to demonstrate the beam injection from one ion source into the KSTAR tokamak plasma in 2010 campaign including the system commissioning of each components and subsystems. In this paper, the construction and the commissioning of the first NBI system with one ion source is presented.

Journal Articles

Efficient production of a collimated MeV proton beam from a Polyimide target driven by an intense femtosecond laser pulse

Nishiuchi, Mamiko; Daido, Hiroyuki; Yogo, Akifumi; Orimo, Satoshi; Ogura, Koichi; Ma, J.-L.; Sagisaka, Akito; Mori, Michiaki; Pirozhkov, A. S.; Kiriyama, Hiromitsu; et al.

Physics of Plasmas, 15(5), p.053104_1 - 053104_10, 2008/05

 Times Cited Count:45 Percentile:83.73(Physics, Fluids & Plasmas)

High-flux energetic protons whose maximum energies are up to 4 MeV are generated by an intense femtosecond Titanium Sapphire laser pulse interacting with a 7.5, 12.5, and 25$$mu$$m thick Polyimide tape targets. The laser pulse energy is 1.7 J, duration is 34 fs, and intensity is 3$$times$$10$$^{19}$$Wcm$$^{-2}$$. The amplified spontaneous emission (ASE) has the intensity contrast ratio of 4$$times$$10$$^{-8}$$. The conversion efficiency from laser energy into proton kinetic energies of $$sim$$3% is achieved, which is comparable or even higher than those achieved in the previous works with nanometer-thick targets and the ultrahigh contrast laser pulses ($$sim$$10$$^{-10}$$).

Journal Articles

Simultaneous proton and X-ray imaging with femtosecond intense laser driven plasma source

Orimo, Satoshi; Nishiuchi, Mamiko; Daido, Hiroyuki; Yogo, Akifumi; Ogura, Koichi; Sagisaka, Akito; Li, Z.*; Pirozhkov, A. S.; Mori, Michiaki; Kiriyama, Hiromitsu; et al.

Japanese Journal of Applied Physics, Part 1, 46(9A), p.5853 - 5858, 2007/09

 Times Cited Count:17 Percentile:54.99(Physics, Applied)

A laser-driven proton beam with a maximum energy of a few MeV is stably obtained using an ultra-short and high-intensity Titanium Sapphire laser. At the same time, keV X-ray is also generated at almost the same place where protons are emitted. Here, we show the successful demonstration of simultaneous proton and X-ray projection images of a test sample placed close to the source with a resolution of $$sim$$10$$mu$$m, which is determined from the source sizes. Although the experimental configuration is very simple, the simultaneity is better than a few hundreds of ps. A CR-39 track detector and imaging plate, which are placed as close as possible to the CR-39, are used as detectors of protons and X-ray. The technique is applicable to the precise observation of microstructures.

Journal Articles

Status of KSTAR electron cyclotron heating system

Bae, Y. S.*; Na, Y. S.*; Oh, Y. K.*; Kwon, M.*; Bak, J. S.*; Lee, G. S.*; Jeong, J. H.*; Park, S. I.*; Cho, M. H.*; Namkung, W.*; et al.

Fusion Science and Technology, 52(2), p.321 - 333, 2007/08

 Times Cited Count:23 Percentile:81.77(Nuclear Science & Technology)

An 84-GHz, 500-kW gyrotron system have been installed at KSTAR, and the initial test of the gyrotron has been carried out with 20 $$mu$$sec-pulse and an output RF power of 500 kW. The launcher system having with a highly flexible steering mirror was fabricated and would inject 500-kW rf power into the KSTAR plasma. KSTAR will employ 170-GHz EC current drive (CD) in ITER-relevant experiments such as the suppression of the neoclassical tearing modes and the creation of an electron internal transport barrier. A JAEA 170-GHz, 1-MW gyrotron on loan in accordance with a Korea-Japan fusion collaboration agreement, and it will be used for the 170-GHz, 1-MW ECCD system in 2010. This paper describes the current status of the installation and initial conditioning tests of the 84-GHz gyrotron system as well as the development plan of the 170-GHz ECH and CD system. Also, this paper discusses the CD efficiency and the steering range of the second-harmonic X-mode injection.

Journal Articles

Measurement of the electron density produced by the prepulse in an experiment of high energy proton beam generation

Jeong, T.*; Choi, I. W.*; Sung, J. H.*; Kim, H.*; Hong, K.*; Yu, T.*; Kim, J.-H.*; Noh, Y.*; Ko, D.-K.*; Lee, J.*; et al.

Journal of the Korean Physical Society, 50(1), p.34 - 39, 2007/01

no abstracts in English

Journal Articles

Development of laser driven proton sources and their applications

Daido, Hiroyuki; Sagisaka, Akito; Ogura, Koichi; Orimo, Satoshi; Nishiuchi, Mamiko; Mori, Michiaki; Ma, J.-L.; Pirozhkov, A. S.; Kiriyama, Hiromitsu; Kanazawa, Shuhei; et al.

Proceedings of 7th Pacific Rim Conference on Lasers and Electro-Optics (CLEO-PR 2007) (CD-ROM), p.77 - 79, 2007/00

We are developing a proton accelerator using an intense lasers with a focused intensity of $$>$$ 10$$^{17}$$ W/cm$$^{2}$$. To monitor proton energy spectra as well as plasma parameters at each laser shot, we are using real time detectors. The proton energy of MeV is stably obtained for applications.

Journal Articles

Intense femto-second laser-driven X-ray source coupled with multiple directional quantum beams for applications

Daido, Hiroyuki; Sagisaka, Akito; Ogura, Koichi; Orimo, Satoshi; Nishiuchi, Mamiko; Yogo, Akifumi; Mori, Michiaki; Li, Z.*; Kiriyama, Hiromitsu; Kanazawa, Shuhei; et al.

X-Ray Lasers 2006; Springer Proceedings in Physics, Vol.115, p.595 - 605, 2007/00

At present, using ultra-short high intensity lasers at APRC, JAEA Kansai photon research institute, we are developing laser driven multiple quantum beams such as protons, X-rays, electrons and THz waves. These beams are perfectly synchronized with each other. The pulse duration of each beam is lass than a pico-second. They have sharp directionality with high brightness. If we properly combined these, we have new pump-probe techniques for various applications.

28 (Records 1-20 displayed on this page)