Oka, Kiyoshi; Seki, Takeshi*; Naito, Takehito*; Watanabe, Shinya*; Wakabayashi, Takao*; Naganawa, Akihiro*; Inui, Kazuo*; Yoshino, Junji*
Nihon Gazo Igaku Zasshi, 28(1), p.12 - 24, 2010/05
Focusing on the measurement function loaded on our rigid-typed endoscope for the fetal surgery treatment, we proposed that its combination with a generally used digestive endoscope enabled calibration of lesion size in stomach. While adding the function, with which the target size is to be easily measured, on the endoscope, we simplified the system structure as much as possible. We also tried to minimize the total cost by using the generally used endoscope, instead of making it from scratch. Combining another development, the composite-type optical fiberscope with diameter of 1.1mm, with a generally used endoscope, we proposed the following as the features: (1)acquisition of fiberscope image, (2)laser irradiation for treatments, (3)applying the real time measurement function of distance and blood flow by semiconductor laser to the generally used endoscope. We have operated the clinical study to the gastric wall of person with no health problem, using this system and confirmed it was available for practical use.
Ishikawa, Noriko; Oka, Kiyoshi; Naganawa, Akihiro*; Yoshino, Junji*; Wakabayashi, Takao*; Watanabe, Shinya*; Naito, Takehito*
Nihon Kikai Gakkai Rombunshu, C, 75(756), p.2359 - 2361, 2009/08
Instruments for measuring the internal pressure of digestive organs are used for diagnosing functional diseases, judging how critical the condition is, and deciding the treatment method or determining the degree of alleviation. However, the technique wherein the internal pressure of the small intestine is measured is highly invasive and painful for patients, and the insertion of the catheter via transducers is not preferred because it involves the insertion of an electric instrument in the body. In this study, we developed a system that measures the pressure of the small intestine with an ileus tube, which is generally used for the treatment of ileus. The main feature of our system is that can be used to measure internal pressure without the insertion of electric instruments such as transducers into the body, allowing the assessment of ileus without causing pain to the patient being treated. In this note, we present a brief description of the structure and function of this instrument used to measure the internal pressure of the small intestine.