Refine your search:     
Report No.
 - 
Search Results: Records 1-12 displayed on this page of 12
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

JAEA Reports

Robot operation manual for reconnaissance

Chiba, Yusuke; Nishiyama, Yutaka; Tsubaki, Hirohiko; Iwai, Masaki; Furukawahara, Ryo; Ono, Hayato*; Hayasaka, Toshiro*

JAEA-Testing 2020-007, 42 Pages, 2021/02

JAEA-Testing-2020-007.pdf:4.38MB

Maintenance and Operation Section for Remote Control Equipment in Naraha Center for Remote Control Technology Development was the main part of the nuclear emergency response team of JAEA in full-scale operation starts on the 1st of April, 2020. In this section, we need to develop equipment for a JAEA nuclear emergency. To support full-scale operation, we have created a work robot for opening and closing doors, a work robot for opening and closing valves, and a reconnaissance robot for measuring radiation dose. This report describes how to operate a Reconnaissance robot.

JAEA Reports

Work robot (for valves opening/closing) operation manual

Chiba, Yusuke; Nishiyama, Yutaka; Tsubaki, Hirohiko; Iwai, Masaki; Ono, Hayato*; Hayasaka, Toshiro*

JAEA-Testing 2020-006, 24 Pages, 2021/02

JAEA-Testing-2020-006.pdf:3.35MB

Maintenance and Operation Section for Remote Control Equipment in Naraha Center for Remote Control Technology Development was the main part of the nuclear emergency response team of JAEA in full-scale operation starts on the 1st of April, 2020. In this section, we need to develop equipment for a JAEA nuclear emergency. To support full- scale operation, we have created a work robot for opening and closing doors, a work robot for opening and closing valves, and a reconnaissance robot for measuring radiation dose. This report describes how to operate a work robot (opening and closing valves).

JAEA Reports

Work robot (for opening and closing the door) operation manual

Chiba, Yusuke; Nishiyama, Yutaka; Tsubaki, Hirohiko; Iwai, Masaki; Furukawahara, Ryo; Ono, Hayato*; Hayasaka, Toshiro*

JAEA-Testing 2020-005, 29 Pages, 2021/02

JAEA-Testing-2020-005.pdf:3.07MB

Maintenance and Operation Section for Remote Control Equipment in Naraha Center for Remote Control Technology Development was the main part of the nuclear emergency response team of JAEA in full-scale operation starts on the 1st of April, 2020. In this section, we need to develop equipment for a JAEA nuclear emergency. To support full-scale operation, we have created a work robot for opening and closing doors, a work robot for opening and closing valves, and a reconnaissance robot for measuring radiation dose. This report describes how to operate the work robot (for opening and closing the door).

JAEA Reports

Design and produce two sets of multi-joint manipulator (for opening a door) against nuclear disaster and a crawler robot for opening and closing manual valves

Nishiyama, Yutaka; Iwai, Masaki; Chiba, Yusuke; Tsubaki, Hirohiko; Ono, Hayato*; Hayasaka, Toshiro*; Hanyu, Toshinori*

JAEA-Technology 2020-007, 18 Pages, 2020/09

JAEA-Technology-2020-007.pdf:2.33MB

Maintenance and Operation Section for Remote Control Equipment in Naraha Center for Remote Control Technology Development is the main part of the nuclear emergency response team of Japan Atomic Energy Agency (JAEA) in full-scale operation starts on the 1st of April, 2020. The section needs to develop equipment for JAEA nuclear emergency. Because of dealing the full-scale operation, the section designed and produced two sets of Multi-joint Manipulator or (for Opening Doors) against Nuclear Disaster in order to put them on two crawler robots in 2018 fiscal year. And the section also designed and produced a Crawler Robot for Opening and Closing Manual Valves in 2019 fiscal year. This report shows two sets of Multi-Joint Manipulator (for Opening Doors) and a Crawler Robot for Opening and Closing Manual Valves designed and produced by Maintenance and Operation Section for Remote Control Equipment in 2018 and 2019 fiscal year.

JAEA Reports

Design and mounting advanced wireless communication equipment on the crawler-type robots for tasks and on the crawler-type scouting robot

Nishiyama, Yutaka; Iwai, Masaki; Tsubaki, Hirohiko; Chiba, Yusuke; Hayasaka, Toshiro*; Ono, Hayato*; Hanyu, Toshinori*

JAEA-Technology 2020-006, 26 Pages, 2020/08

JAEA-Technology-2020-006.pdf:2.43MB

Maintenance and Operation Section for Remote Control Equipment in Naraha Center for Remote Control Technology Development is the main part of the nuclear emergency response team of JAEA deal with Act on Special Measures Concerning Nuclear Emergency Preparedness. The section needs to remodel crawler-type robots for tasks, crawler-type scouting robots, and so on. About two crawler-type robots for tasks, the section designed and mounted advanced wireless communication equipment on manipulators mounted on the two robots. The crawler part of the robot has been able to be controlled by way of the new equipment, and when it is broken down, it can be changed by way of an original equipment. And the new equipment makes a single relay robot controllable both the crawler part and the manipulator part of the robot, in case of wireless relay robots being needed. And after checking the ability and characteristic about 5 wireless communication equipment, the section chose and mounted the best equipment on one crawler-type scouting robot. This report shows design and mounting advanced wireless communication equipment on the two crawler-type robots for tasks and on the one crawler-type scouting robot.

JAEA Reports

Training programs of emergency response robots operation for operators in each site of JAEA beginner class / intermediate class

Chiba, Yusuke; Nishiyama, Yutaka; Tsubaki, Hirohiko; Iwai, Masaki

JAEA-Technology 2019-002, 29 Pages, 2019/03

JAEA-Technology-2019-002.pdf:2.43MB

Act on Special Measures Concerning Nuclear Emergency Preparedness was amended on the 30th of October in 2017. As the JAEA Emergency Assistance Organization, Maintenance and Operation Section for Remote Control Equipment in Naraha Center for Remote Control Technology Development started training for emergency response robots operation for operators in each site of JAEA in response to the new amendment. The training consists of three operations: small crawler-type mobile scouting robots, big crawler-type mobile robots with a manipulator or a long tong and small radio-controlled helicopters. The training has three classes (beginner, intermediate and advanced classes) depending on skills and experiences. This paper reports the training programs of emergency response robots operation of the beginner and intermediate classes which were used in the first half of fiscal 2018.

JAEA Reports

Verification of alternative dew point hygrometer for CV-LRT in MONJU; Short- and long-term verification for capacitance-type dew point hygrometer (Translated document)

Ichikawa, Shoichi; Chiba, Yusuke; Ono, Fumiyasu; Hatori, Masakazu; Kobayashi, Takanori; Uekura, Ryoichi; Hashiri, Nobuo*; Inuzuka, Taisuke*; Kitano, Hiroshi*; Abe, Hisashi*

JAEA-Research 2017-001, 40 Pages, 2017/03

JAEA-Research-2017-001.pdf:5.19MB

In order to reduce the influence on a plant schedule of the MONJU by the maintenance of dew point hygrometers, The JAEA examined a capacitance type dew point hygrometer as an alternative dew point hygrometer for a lithium-chloride type dew point hygrometer which had been used at the CV-LRT in the MONJU. As a result of comparing a capacitance type dew point hygrometer with a lithium-chloride type dew point hygrometer at the CV-LRT (Atmosphere: nitrogen, Testing time: 24 hours), there weren't significant difference between a capacitance type dew point hygrometer and a lithium-chloride type dew point hygrometer. As a result of comparing a capacitance dew point hygrometer with a high-mirror-surface type dew point hygrometer for long term verification (Atmosphere: air, Testing time: 24 months), the JAEA confirmed that a capacitance type dew point hygrometer satisfied the instrument specification ($$pm$$2.04$$^{circ}$$C) required by the JEAC4203-2008.

JAEA Reports

Verification of alternative dew point hygrometer for CV-LRT in Monju

Ichikawa, Shoichi; Chiba, Yusuke; Ono, Fumiyasu; Hatori, Masakazu; Kobayashi, Takanori; Uekura, Ryoichi; Hashiri, Nobuo*; Inuzuka, Taisuke*; Kitano, Hiroshi*; Abe, Hisashi*

JAEA-Research 2016-021, 32 Pages, 2017/02

JAEA-Research-2016-021.pdf:5.0MB

In order to reduce the influence on a plant schedule of the MONJU by the maintenance of dew point hygrometers, The JAEA examined a capacitance type dew point hygrometer as an alternative dew point hygrometer for a lithium-chloride type dew point hygrometer which had been used at the CV-LRT in the MONJU. As a result of comparing a capacitance type dew point hygrometer with a lithium-chloride type dew point hygrometer at the CV-LRT (Atmosphere: nitrogen, Testing time: 24 hours), there weren't significant difference between a capacitance type dew point hygrometer and a lithium-chloride type dew point hygrometer. As a result of comparing a capacitance dew point hygrometer with a high-mirror-surface type dew point hygrometer for long term verification (Atmosphere: air, Testing time: 24 months), the JAEA confirmed that a capacitance type dew point hygrometer satisfied the instrument specification ($$pm$$2.04$$^{circ}$$C) required by the JEAC4203-2008.

Oral presentation

Precise measurements of projectile charge changing cross sections for intermediate energy heavy ions

Chiba, Satoshi; Ota, Shuya*; Yasuda, Nakahiro*; Sihver, L.*; Kodaira, Satoshi*; Ideguchi, Yusuke*; Hasebe, Nobuyuki*

no journal, , 

no abstracts in English

Oral presentation

Verification test of alternative dew point detector for CV-LRT in Monju

Chiba, Yusuke; Ichikawa, Shoichi; Ono, Shimpei; Hatori, Masakazu; Kobayashi, Takanori; Uekura, Ryoichi; Hashiri, Nobuo*; Inuzuka, Taisuke*; Abe, Hisashi*; Kitano, Hiroshi*

no journal, , 

The lithium chloride-type dew point detector was used for reactor containment vessel the entire leak rate test (CV-LRT) in fast-breeder reactor Monju (Monju) which needs the maintenance every three months. But when the plant process is considered, it's desirable for the maintenance periods beyond 12 months. Thereupon the capacitance-type dew point detector made in VAISALA Corporation was nominated as the alternative lithium chloride-type dew point detector in Monju. The lithium chloride-type dew point detector, when it's adopted, for, to have to be satisfied a request of the regulations, it's necessary to estimate the performance of the lithium chloride-type dew point detector. In the condition of the CV-LRT, the dew point data were measured by the capacitance-type dew point detector and the lithium chloride-type dew point detector for 24 hours. These data were compared and the performance of the capacitance-type dew point detector was estimated. Furthermore, the dew point data of Monju under the atmosphere ware continuously measured by the capacitance-type dew point detector and the mirror surface-type dew point detector for 2 years. These data were compared and the performance of the capacitance-type dew point detector was estimated. As a result, the capacitance-type dew point detector was confirmed that had the instrument precision that JEAC4203-2008 required.

Oral presentation

Verification of alternative dew point hygrometer for CV-LRT in MONJU; Short and long-term verification for capacitance type dew point hygrometer

Hatori, Masakazu; Ichikawa, Shoichi; Chiba, Yusuke; Kobayashi, Takanori; Uekura, Ryoichi; Hashiri, Nobuo*; Inuzuka, Taisuke*; Kitano, Hiroshi*; Abe, Hisashi*; Ono, Fumiyasu

no journal, , 

In order to reduce the influence on a plant schedule of Monju by the maintenance of dew point hygrometers, JAEA Agency examined a capacitance type dew point hygrometer as an alternative dew point hygrometer for a lithium-chloride type dew point hygrometer which had been used at the containment vessel leak rate test in Monju. As a result of comparing a capacitance type dew point hygrometer with a lithium-chloride type dew point hygrometer at the CV-LRT (Atmosphere: nitrogen, testing time/24 hours), there was no significant difference between a capacitance type dew point hygrometer and a lithium-chloride type dew point hygrometer. As a result of comparing a capacitance dew point hygrometer with a high-precision-mirror-surface type dew point hygrometer for long term verification (Atmosphere: air, testing time: 24 months), it was confirmed that a capacitance type dew point hygrometer satisfied the instrument specification required by the CV-LRT. There are no other cases where atmosphere measurement has been carried out for a long time by existing measuring instruments.

Oral presentation

Challenge for Mo-99/Tc-99m production by JRR-3

Chiba, Yusuke

no journal, , 

Japan depends on foreign countries for many medical isotopes, and in order to realize domestic production from the viewpoint of enhancing the security of the medical system, the Atomic Energy Commission formulated the "Action Plan for the Production and Use of Radioisotopes for Medical Purposes" on 2022. In this Action Plan, one of the goals is to "manufacture and supply approximately 30% of the domestic demand for Mo-99/Tc-99m by utilizing JRR-3". JRR-3 has several utilization facilities for neutron beam experiments, irradiation tests of reactor material, and manufacturing radio isotopes for medicine use and silicon semiconductor by transmutation. JAEA is aiming to establish production technology of Mo-99 by neutron capture method, making effective use of the performance of JRR-3. The demonstration test is scheduled to be completed in 2025, and the prospect for domestic production of Mo-99 is expected to be established. In this issue, we will introduce the current status of the test.

12 (Records 1-12 displayed on this page)