Refine your search:     
Report No.
 - 
Search Results: Records 1-12 displayed on this page of 12
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Prompt in-line diagnosis of single bunch transverse profiles and energy spectra for laser-accelerated ions

Sakaki, Hironao; Nishiuchi, Mamiko; Hori, Toshihiko; Bolton, P.; Yogo, Akifumi; Katagiri, Masaki*; Ogura, Koichi; Sagisaka, Akito; Pirozhkov, A. S.; Orimo, Satoshi; et al.

Applied Physics Express, 3(12), p.126401_1 - 126401_3, 2010/11

 Times Cited Count:8 Percentile:34.47(Physics, Applied)

Many applications of laser-accelerated ions will require beamlines with diagnostic capability for validating simulations and machine performance at the single bunch level as well as for the development of controls to optimize machine performance. We demonstrated prompt, in-line, single bunch transverse profile and energy spectrum detection using a thin luminescent diagnostic and scintillator-based time-of-flight spectrometer simultaneously. The Monte Carlo code, particle and heavy ion transport code systems (PHITS) simulation is shown to be reasonably predictive at low proton energy for the observed transverse profiles measured by the thin luminescent monitor and also for single bunch energy spectra measured by time-of-flight spectrometry.

Journal Articles

Test beam-line for laser-driven proton therapy

Sakaki, Hironao; Nishiuchi, Mamiko; Hori, Toshihiko; Bolton, P.; Yogo, Akifumi; Ogura, Koichi; Sagisaka, Akito; Pirozhkov, A. S.; Orimo, Satoshi; Kondo, Kiminori; et al.

Proceedings of 7th Annual Meeting of Particle Accelerator Society of Japan (DVD-ROM), p.312 - 315, 2010/08

The beam transport test is carried out through the test beam line of the laser-driven proton accelerator which consists of the phase rotation cavity, PMQ, and bending magnet. The laser system used is J-KAREN at JAEA. The final transmitted bunch duration and transverse profile are well predicted by the PARMILA particle transport code by assuming relatively low initial current of the proton beam. The most probable explanation for this is the space charge neutralization by the laser-plasma-electrons.

Journal Articles

Measured and simulated transport of 1.9 MeV laser-accelerated proton bunches through an integrated test beam line at 1 Hz

Nishiuchi, Mamiko; Sakaki, Hironao; Hori, Toshihiko; Bolton, P.; Ogura, Koichi; Sagisaka, Akito; Yogo, Akifumi; Mori, Michiaki; Orimo, Satoshi; Pirozhkov, A. S.; et al.

Physical Review Special Topics; Accelerators and Beams, 13(7), p.071304_1 - 071304_7, 2010/07

 Times Cited Count:25 Percentile:79.49(Physics, Nuclear)

A laser-driven repetition-rated 1.9 MeV proton beam line composed of permanent quadrupole magnets (PMQs), a radio frequency (rf) phase rotation cavity, and a tunable monochromator is developed to evaluate and to test the simulation of laser-accelerated proton beam transport through an integrated system for the first time. In addition, the proton spectral modulation and focusing behavior of the rf phase rotationcavity device is monitored with input from a PMQ triplet. In the 1.9 MeV region we observe very weakproton defocusing by the phase rotation cavity. The final transmitted bunch duration and transverse profile are well predicted by the PARMILA particle transport code. The transmitted proton beam duration of 6 ns corresponds to an energy spread near 5% for which the transport efficiency is simulated to be 10%. The predictive capability of PARMILA suggests that it can be useful in the design of future higher energy transport beam lines as part of an integrated laser-driven ion accelerator system.

Journal Articles

Laser-driven proton accelerator for medical application

Nishiuchi, Mamiko; Sakaki, Hironao; Hori, Toshihiko; Bolton, P.; Ogura, Koichi; Sagisaka, Akito; Yogo, Akifumi; Mori, Michiaki; Orimo, Satoshi; Pirozhkov, A. S.; et al.

Proceedings of 1st International Particle Accelerator Conference (IPAC '10) (Internet), p.88 - 90, 2010/05

The concept of a compact ion particle accelerator has become attractive in view of recent progress in laser-driven ion acceleration. We report here the recent progress in the laser-driven proton beam transport at the Photo Medical Research Center (PMRC) at JAEA, which is established to address the challenge of laser-driven ion accelerator development for ion beam cancer therapy.

Journal Articles

Designing integrated laser-driven ion accelerator systems for hadron therapy at PMRC (Photo Medical Research Center)

Sakaki, Hironao; Hori, Toshihiko; Nishiuchi, Mamiko; Bolton, P.; Daido, Hiroyuki; Kawanishi, Shunichi; Sutherland, K.*; Soda, Hikaru*; Noda, Akira*; Iseki, Yasushi*; et al.

Proceedings of 2009 Particle Accelerator Conference (PAC '09) (DVD-ROM), p.1309 - 1311, 2009/05

The concept of a compact ion particle accelerator has become attractive in view of recent progress in laser-driven hadrons acceleration. The Photo Medical Research Center (PMRC) of JAEA was recently established to address the challenge of laser-driven ion accelerator development for hadron beam cancer therapy. PMRC considers conceptual designs of such a therapeutic instrument based on the current state in the laser-driven acceleration. We describe a conceptual gantry device that is designed by the general-purpose ion accelerator design code, PARMILA.

Journal Articles

Focusing and spectral enhancement of a repetition-rated, laser-driven, divergent multi-MeV proton beam using permanent quadrupole magnets

Nishiuchi, Mamiko; Daito, Izuru; Ikegami, Masahiro; Daido, Hiroyuki; Mori, Michiaki; Orimo, Satoshi; Ogura, Koichi; Sagisaka, Akito; Yogo, Akifumi; Pirozhkov, A. S.; et al.

Applied Physics Letters, 94(6), p.061107_1 - 061107_3, 2009/02

 Times Cited Count:57 Percentile:87.53(Physics, Applied)

A pair of conventional permanent magnet quadrupoles is used to focus a 2.4 MeV laser-driven proton beam at a 1 Hz repetition rate. The magnetic field strengths are 55 T/m and 60 T/m for the first and second quadrupoles respectively. The proton beam is focused to a spot size (full width at half maximum) of 2.7$$times$$8 mm$$^{2}$$ at a distance of 650 mm from the source. This result is in good agreement with a Monte Carlo particle trajectory simulation.

Journal Articles

High power tests of the cryogenic window for millimeter wave

Kasugai, Atsushi; Yokokura, Kenji; Sakamoto, Keishi; Tsuneoka, Masaki; Yamamoto, Takumi; Imai, Tsuyoshi; Saito, Yasushi*; *; *; Ebisawa, Katsuyuki*

Proceedings of the 19th International Conference on Infrared and Millimeter Waves, 0, p.295 - 296, 1994/00

no abstracts in English

Journal Articles

High power test of RF cavity for SPring-8 booster synchrotron

Suzuki, Hiromitsu; *; Yonehara, Hiroto; Harami, Taikan; ; Kawashima, Yoshitaka*; *; Inoue, K.*; Hara, Masahiro*; *

Proc. of the 8th Symp. on Accelerator Science and Technology, p.113 - 115, 1991/00

no abstracts in English

JAEA Reports

Development of the in-vessel inspection system on JT-60

*; Takatsu, Hideyuki; Arai, Takashi; ; Kaminaga, Atsushi; Okubo, Minoru; *; *

JAERI-M 87-070, 44 Pages, 1987/05

JAERI-M-87-070.pdf:3.18MB

no abstracts in English

Oral presentation

Transportation of the laser-driven MeV proton beam for the application; Spatial focusing and spectral enhancement with PMQs

Nishiuchi, Mamiko; Daito, Izuru; Mori, Michiaki; Orimo, Satoshi; Ogura, Koichi; Sagisaka, Akito; Sakaki, Hironao; Hori, Toshihiko; Yogo, Akifumi; Pirozhkov, A. S.; et al.

no journal, , 

From our previous research, we have successfully produce MeV proton beam by 1Hz repetition rate stabely from the interaction between the femto-second TW laser with solid target. Produced proton beam exhibits lower emittance. The number of proton beam is 10$$^{13}$$. However, it shows large divergence angle of 10 degree. The energy spectrum exhibits 100% energy spread. These are problematic for some specific applications. In this study we transported the laser-driven proton beam with permanent quadrapole magnet for the future application. We successfully obtain focused proton beam as well as the monochromatic proton beam. Those spatial distribution at the focus point as well as the spectral information is well reproduced by the montecalro simulation.

Oral presentation

Towards the laser-driven proton accelerator for cancer therapy; Benchmark test of the PARMILA code at the transport and irradiation test beam line

Nishiuchi, Mamiko; Sakaki, Hironao; Hori, Toshihiko; Bolton, P.; Ogura, Koichi; Yogo, Akifumi; Pirozhkov, A. S.; Sagisaka, Akito; Orimo, Satoshi; Mori, Michiaki; et al.

no journal, , 

no abstracts in English

Oral presentation

Prototype of beam transport line for laser-driven proton therapy

Sakaki, Hironao; Nishiuchi, Mamiko; Hori, Toshihiko; Kondo, Kiminori; Ogura, Koichi; Yogo, Akifumi; Sagisaka, Akito; Orimo, Satoshi; Mori, Michiaki; Tampo, Motonobu; et al.

no journal, , 

We constructed prototype transportation system of the laser driven 2.0MeV by using nuclear power mechanism J-KAREN laser, and we measured and analyzed this beam line.

12 (Records 1-12 displayed on this page)
  • 1