Sakamoto, Atsushi; Kibe, Satoshi*; Kawanobe, Kazunori*; Fujisaku, Kazuhiko*; Sano, Yuichi; Takeuchi, Masayuki; Suzuki, Hideya*; Tsubata, Yasuhiro; Ban, Yasutoshi; Matsumura, Tatsuro
JAEA-Research 2021-003, 30 Pages, 2021/06
Japan Atomic Energy Agency has been developing a solvent extraction process called SELECT to recover minor actinides (MA) from spent nuclear fuel. In the SELECT process, TDdDGA, HONTA, and ADAAM are used as the extractants for MA + Ln corecovery, MA/Ln separation and Am/Cm separation, respectively. These extractants do not contain phosphorus (P), and consist of carbon (C), hydrogen (H), oxygen (O), and nitrogen (N). In this study, in order to give beneficial information for designing flowsheet, the mass transfer coefficients of Ln between HNO solution and TDdDGA or HONTA / n-dodecane solvent were evaluated by the single drop technique. Prior to the evaluation of mass transfer coefficient, we had optimized the structure of the single drop apparatus to improve accuracy of the measurement. Based on the mass transfer coefficients obtained in HNO / TDdDGA-n-dodecane system, Ln behaviors in the counter-current extraction and back-extraction using mixer-settlers and centrifugal contactors were estimated by simple calculation, and they had a good agreement with our previous experimental results. We also confirmed the mass transfer coefficients of Ln in HNO / HONTA - n-dodecane system are under 10 m/s.
Sano, Yuichi; Sakamoto, Atsushi; Takeuchi, Masayuki; Misumi, Ryuta*; Kunii, Kanako*; Todoroki, Kei*; Nishi, Kazuhiko*; Kaminoyama, Meguru*
Kagaku Kogaku Rombunshu, 44(6), p.335 - 340, 2018/11
Concerning an annular centrifugal contactor which has high throughput and separation performance, the effect of operational condition on fluidic and dispersion behavior, which are important to improve the contactor performance, was investigated by computational fluid dynamics (CFD) analysis based on the turbulence model, and the calculated results were validated by experimental data. The liquid phase in the annular zone was gradually divided into two regions vertically with increasing the rotor speed and decreasing the flowrate, and the liquid flow moved toward the center of the housing bottom was generated in the lower annular zone under any operational condition. The droplet size of the dispersed phase in the annular zone decreased with increasing the rotor speed and decreasing the flowrate. These calculation results showed a good agreement with experimental data. The CFD analysis considering mass transfer between aqueous and organic phases was also attempted, and it was confirmed that the change of extraction performance with the rotor speed showed the same tendency as the experimental result.
Takahatake, Yoko; Ambai, Hiromu; Sano, Yuichi; Takeuchi, Masayuki; Koizumi, Kenji; Sakamoto, Kan*; Yamashita, Shinichiro
Proceedings of Annual Topical Meeting on Reactor Fuel Performance (TopFuel 2018) (Internet), 9 Pages, 2018/10
The corrosion behaviour of FeCrAl-ODS steels for the accident tolerant fuel cladding of LWRs were investigated in nitric acid solutions for the reprocessing process of spent fuels. The corrosion tests were carried out at 60C, 80C and the boiling point of the solutions, and the specimens were then analysed by XPS. The corrosion remarkably progressed at the boiling point, and the highest corrosion rate was 0.22 mm/y. In the oxide film, the atomic concentration of Fe was lower, than that in the base material, and those of Cr and Al were higher. The results show that the corrosion of FeCrAl-ODS steels in hot nitric acid solution is not severe because of the high corrosion resistance of the oxide film formed on the material; hence, the corrosion resistance of the new cladding materials in the dissolution process of spent fuel is acceptable for reprocessing operations.
Misumi, Ryuta*; Todoroki, Kei*; Kunii, Kanako*; Nishi, Kazuhiko*; Kaminoyama, Meguru*; Sano, Yuichi; Sakamoto, Atsushi; Takeuchi, Masayuki
Kagaku Kogaku Rombunshu, 44(5), p.285 - 291, 2018/09
Annular centrifugal extractors have been anticipated for use as extractors in spent nuclear fuel recycling. The extraction rate and the liquid-liquid dispersion are related to the flow pattern in the vessel. However, no study has clarified flow patterns in vessels of various scales. For this study, flow pattern characteristics are quantified for extractors of two scales. An extractor has a mixing zone around the vessel bottom and a separation zone in the cylindrical rotor. For this experiment, distilled water was fed into the vessel. Flow behavior in the mixing zone was observed from a side view using a digital video camera at various rotor speeds and supply flow rates for extractors of two scales. In some cases, the liquid horizontal velocity vectors in the mixing zone were measured using particle image velocimetry. Results demonstrate that flow behaviors in the mixing zone in both scales of extractors are classifiable as three types, changing with operational conditions: Type A, Type B, and a Transition regime. For the Type A state, the mixing zone is fully filled with liquid from the vessel bottom up to the lower edge of the rotor. In the Type B state, the zone with existing liquid is vertically divisible into two regions. Lower rotor speeds and higher flow rates tend to produce Type A state flow behavior. The boundary operational condition between Type A and the Transition regime are correlated with the normalized supply flow rate and pumping capacity of the rotor, which is evaluated from liquid surface level in a rotor formed by centrifugal force. Furthermore, the fluid velocity in the mixing zone is roughly proportional to the rotor surface circumferential speed irrespective of the vessel scale.
Sano, Yuichi; Sakamoto, Atsushi; Kofuji, Hirohide; Takeuchi, Masayuki
Proceedings of 21st Pacific Basin Nuclear Conference (PBNC 2018) (USB Flash Drive), p.314 - 318, 2018/09
The effect of operational condition of the annular centrifugal contactor (ACC) on U extraction behavior was investigated by computational fluid dynamics (CFD) analysis considering mass transfer between aqueous and organic phases, and the calculation results were validated experimentally. The CFD analysis with ANSYS FLUENT was carried out using the Eulerian multi-fluid approach with a standard k- turbulence model. In order to calculate the droplet size of the dispersed phase and mass transfer between aqueous and organic phases, user-defined functions (UDF) were created. The changes of U extraction performance, i.e. U stage efficiency, with the rotor speed and the O/A ratio (= organic flowrate / aqueous flowrate) were calculated, and these showed a good agreement with experimental results.
Misumi, Ryuta*; Kunii, Kanako*; Todoroki, Kei*; Nishi, Kazuhiko*; Kaminoyama, Meguru*; Sano, Yuichi; Sakamoto, Atsushi; Takeuchi, Masayuki
Kagaku Kogaku Rombunshu, 44(3), p.135 - 141, 2018/05
Times Cited Count:1 Percentile:4.81(Engineering, Chemical)Annular centrifugal extractors have been used in spent nuclear fuel reprocessing, but the relation between the extraction rate and flow pattern in the vessel remains unclear. This study quantifies characteristics of the flow pattern to clarify this relation. An extractor produces a mixing zone around the vessel bottom and a separation zone in the rotor. The horizontal velocity of the liquid in the mixing zone was measured using particle image velocimetry at various rotor speeds and supply flow rates. Flow behaviors in the mixing zone are of three types, changing with operational conditions: Type A, Type B, and a transition regime. At lower rotor speeds and high supply flow rates, the mixing zone is fully filled with liquid from the vessel bottom up to the lower edge of the rotor: the Type A flow state. At high rotor speeds and low supply flow rates, the zone with existing liquid is vertically divisible into two regions: near the vanes and around the bottom of the rotor, which is the Type B flow state. A transition regime is also observed between Type A and Type B state. In each region surrounding the two vanes on the vessel bottom and the vessel wall, the liquid flowed in the direction of rotor rotation along the vessel wall. Liquid flow altered by the vane flowed toward the center of vessel bottom. The liquid then entered the separation zone through the orifice at the rotor bottom. For the Type A state, the horizontal velocity distribution was roughly proportional to the rotor speed. For the Type B state, the horizontal velocities around the vessel bottom were lower than those of Type A and were not proportional to the rotor speed. Presumably, the liquid fed into the vessel went directly to the rotor instead of passing between the two vanes attached to the vessel bottom.
Kibe, Satoshi; Fujisaku, Kazuhiko*; Sakamoto, Atsushi; Sano, Yuichi; Takeuchi, Masayuki; Suzuki, Hideya; Tsubata, Yasuhiro; Matsumura, Tatsuro
JAEA-Research 2016-024, 40 Pages, 2017/02
The Japan Atomic Energy Agency has been developing some flowsheets with TDdDGA (N,N,N,Ntetradodecyldiglycolamide) extractant to recover MA (minor actinide) from raffinate. In this study, countercurrent experiments with the improved flowsheet, e.g. the addition of alcohol into the solvent for preventing the precipitation, were performed using miniature centrifugal contactors in order to compare the extraction/stripping behavior of each element with the mixer-settler type. As a result, no entrainments were observed and sufficient phase separation was achieved by centrifugal contactors without any abnormal fluid behavior, such as overflow. The extraction and stripping of Ln(III) which show the similar tendencies as MA could be achieved successfully, especially their stripping proceeded more efficiently in centrifugal contactors. This might be due to the increase in stripping rates by improving the flowsheet and to superior phase separation performance of centrifugal contactors.
Sakamoto, Atsushi; Sano, Yuichi; Takeuchi, Masayuki
Procedia Chemistry, 21, p.495 - 502, 2016/12
Times Cited Count:2 Percentile:81(Chemistry, Inorganic & Nuclear)Kibe, Satoshi; Fujisaku, Kazuhiko*; Ambai, Hiromu; Sakamoto, Atsushi; Sano, Yuichi; Takeuchi, Masayuki; Suzuki, Hideya; Tsubata, Yasuhiro; Matsumura, Tatsuro
JAEA-Research 2015-021, 40 Pages, 2016/02
The flowsheet with TDdDGA extractant has been being developed for recovering MA from PUREX raffinate. In the previous study, the yields of MA and other elements in countercurrent extraction/stripping experiments using mixer-settlers were not enough for the target and it would be due to the insufficient phase (aqueous/organic) separation. In this study, we carried out countercurrent experiments with surrogate PUREX raffinate using centrifugal contactors which had superior phase separation ability, and evaluated the extraction/stripping behavior of each element. During the operation, abnormal fluid behavior, such as overflow and entrainment, was not observed, and sufficient phase separation was achieved by centrifugal contactors. Extraction behavior of lanthanides was similar to that in mixer-settlers, but their stripping efficiencies decreased. This would be due to shorter residence time in mixing zone.
Hoshino, Yuzuru; Sakamoto, Yoshiaki; Muroi, Masayuki*; Mukai, Satoru*
JAEA-Technology 2015-015, 96 Pages, 2015/07
In order to dispose of the radioactive waste which generates from post-irradiation examination (PIE) facilities, the common evaluation method of radioactivity in wastes from PIE should be established by the actual data such as radioactivity values and the theoretical calculation. In this study, the radioactivity concentrations of 17 nuclides (H-3, C-14, Co-60, Ni-63, Sr-90, Tc-99, Cs-137, Eu-154, U-234, U-235, U-238, Pu-238, Pu-239, Pu-240, Pu-241, Am-241, Cm-244) in combustible wastes stored in NUCLEAR DEVELOPMENT CORPORATION were measured from 3 samples and the radioactivity was calculated by ORIGEN-2 based on initial contents and operation record of the spent fuel. From the comparison of the obtained data by the radiological measurement with the calculated values, the subject to be solved for establishment of the radioactivity evaluation method for PIE was extracted.
Sakamoto, Atsushi; Sano, Yuichi; Takeuchi, Masayuki; Okamura, Nobuo; Koizumi, Kenji
Proceedings of 23rd International Conference on Nuclear Engineering (ICONE-23) (DVD-ROM), 5 Pages, 2015/05
Obara, Kenjiro; *; Kakudate, Satoshi; Shibanuma, Kiyoshi; Tada, Eisuke; *; *; *
JAERI-M 92-130, 34 Pages, 1992/09
no abstracts in English
Sakamoto, Atsushi; Takeuchi, Masayuki; Ogino, Hideki; Koizumi, Kenji; Sawahata, Osamu*; Sakamoto, Yukio*; Akutsu, Koichi*
no journal, ,
no abstracts in English
Arai, Yoichi; Takeuchi, Masayuki; Sakamoto, Atsushi; Ohata, Fumikazu; Okamura, Nobuo; Ogino, Hideki; Koizumi, Kenji
no journal, ,
no abstracts in English
Okamura, Nobuo; Sakamoto, Atsushi; Takeuchi, Masayuki; Koizumi, Kenji; Sakamoto, Yukio*
no journal, ,
no abstracts in English
Ohata, Fumikazu; Sakamoto, Atsushi; Takeuchi, Masayuki; Koizumi, Kenji; Sawahata, Osamu*; Sakamoto, Yukio*; Akutsu, Koichi*
no journal, ,
no abstracts in English
Nakahara, Masaumi; Sano, Yuichi; Sakamoto, Atsushi; Takeuchi, Masayuki; Nakajima, Yasuo
no journal, ,
Centrifugal contactors is expected to apply to co-processing process, but there is concern that the mixing time of centrifugal contactors is not enough to reduce Pu because it is shorter than that of mixer-settlers. To study the influence of mixing time on the Pu reduction, the countercurrent experiments were carried out with a centrifugal contactor. The relationship of mixing time and Pu recovery ratio was evaluated, and mixing time for Pu reduction partitioning is indicated in an engineering plant.
Sakamoto, Atsushi; Sano, Yuichi; Takeuchi, Masayuki; Ito, Kazuyuki*; Sekita, Satoshi*; Sakamoto, Yukio*; Akutsu, Koichi*
no journal, ,
no abstracts in English
Sakamoto, Atsushi; Okamura, Nobuo; Sano, Yuichi; Takeuchi, Masayuki
no journal, ,
no abstracts in English
Ishihara, Nozomi*; Misumi, Ryuta*; Nishi, Kazuhiko*; Kaminoyama, Meguru*; Sano, Yuichi; Sakamoto, Atsushi; Takeuchi, Masayuki; Koizumi, Kenji
no journal, ,
no abstracts in English