Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 191

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Contrast dependence of scattering profiles for poly(ethylene glycol) in water; Investigation by small-angle neutron scattering with $$^{3}$$He spin filter and small-angle X-ray scattering

Ryoki, Akiyuki*; Watanabe, Fumi*; Okudaira, Takuya*; Takahashi, Shingo*; Oku, Takayuki; Hiroi, Kosuke; Motokawa, Ryuhei; Nakamura, Yo*

Journal of Chemical Physics, 160(11), p.114907_1 - 114907_9, 2024/03

Journal Articles

Neutron transmission CB-KID imager using samples placed at room temperature

Ishida, Takekazu*; Vu, TheDang*; Shishido, Hiroaki*; Aizawa, Kazuya; Oku, Takayuki; Oikawa, Kenichi; Harada, Masahide; Kojima, Kenji M*; Miyajima, Shigeyuki*; Koyama, Tomio*; et al.

Journal of Low Temperature Physics, 214(3-4), p.152 - 157, 2024/02

 Times Cited Count:0 Percentile:0.02(Physics, Applied)

Journal Articles

Orientation mapping of YbSn$$_{3}$$ single crystals based on Bragg-dip analysis using a delay-line superconducting sensor

Shishido, Hiroaki*; Vu, TheDang*; Aizawa, Kazuya; Kojima, Kenji M*; Koyama, Tomio*; Oikawa, Kenichi; Harada, Masahide; Oku, Takayuki; Soyama, Kazuhiko; Miyajima, Shigeyuki*; et al.

Journal of Applied Crystallography, 56(4), p.1108 - 1113, 2023/08

 Times Cited Count:0 Percentile:0.02(Chemistry, Multidisciplinary)

Journal Articles

Polarized neutrons observed nanometer-thick crystalline ice plates in frozen glucose solution

Kumada, Takayuki; Nakagawa, Hiroshi; Miura, Daisuke; Sekine, Yurina; Motokawa, Ryuhei; Hiroi, Kosuke; Inamura, Yasuhiro; Oku, Takayuki; Oishi, Kazuki*; Morikawa, Toshiaki*; et al.

Journal of Physical Chemistry Letters (Internet), 14(34), p.7638 - 7643, 2023/08

 Times Cited Count:0 Percentile:0.01(Chemistry, Physical)

The structure of nano-ice crystals in rapidly frozen glucose solution was elucidated by using spin-contrast-variation small-angle neutron scattering, which distinguishes the nano-ice crystal signal from the frozen amorphous solution signal by the polarization-dependent neutron scattering. The analysis revealed that the nano-ice crystals form a planar structure with a diameter exceeding tens of nanometers and a thickness of 1 nm, which is close to the critical nucleation size. This result suggests that the glucose molecules are preferentially bound to a specific face of nano-ice crystals, and then block the crystal growth perpendicular to that face.

Journal Articles

Measurement of the transverse asymmetry of $$gamma$$ rays in the $$^{117}$$Sn($$n,gamma$$)$$^{118}$$Sn reaction

Endo, Shunsuke; Okudaira, Takuya*; Abe, Ryota*; Fujioka, Hiroyuki*; Hirota, Katsuya*; Kimura, Atsushi; Kitaguchi, Masaaki*; Oku, Takayuki; Sakai, Kenji; Shima, Tatsushi*; et al.

Physical Review C, 106(6), p.064601_1 - 064601_7, 2022/12

 Times Cited Count:2 Percentile:52.69(Physics, Nuclear)

no abstracts in English

Journal Articles

Structure analysis of asymmetric interface using spin-contrast-variation neutron reflectometry

Kumada, Takayuki; Miura, Daisuke*; Akutsu, Kazuhiro*; Oku, Takayuki; Torikai, Naoya*; Niizeki, Tomotake*

Hamon, 32(4), p.165 - 168, 2022/11

We demonstrated the advantage of spin-contrast-variation neutron reflectometry on the structure analysis of buried interface between resin and porous silica layers. The interface structure was not reproduced by the normal Gaussian model, but by the asymmetric interface model where crosslinked polymer chains neither permeate the pore nor follow the surface roughness of the silica layer.

Journal Articles

Structure analysis of a buried interface between organic and porous inorganic layers using spin-contrast-variation neutron reflectivity

Kumada, Takayuki; Miura, Daisuke*; Akutsu, Kazuhiro*; Oishi, Kazuki*; Morikawa, Toshiaki*; Kawamura, Yukihiko*; Suzuki, Junichi*; Oku, Takayuki; Torikai, Naoya*; Niizeki, Tomotake*

Journal of Applied Crystallography, 55(5), p.1147 - 1153, 2022/10

AA2021-0903.pdf:1.06MB

 Times Cited Count:1 Percentile:29.53(Chemistry, Multidisciplinary)

Spin-contrast-variation neutron reflectivity obtains multiple reflectivity curves from a single sample and a single beam source. We used the strong point of the technique to reveal that, although methylated-perhydropolysilazane-derived silica layer has a higher porosity near the interface with acrylic urethane resin, the resin did not permeate the pore network.

Journal Articles

Development of spin-contrast-variation neutron powder diffractometry for extracting the structure factor of hydrogen atoms

Miura, Daisuke*; Kumada, Takayuki; Sekine, Yurina; Oku, Takayuki; Takata, Shinichi; Hiroi, Kosuke; Iwata, Takahiro*

J-PARC 22-02; J-PARC MLF Annual Report 2021, p.6 - 7, 2022/03

We carried out spin contrast variation neutron powder diffractometry of glutamic acid crystal. The diffraction peak intensities varied as a function of proton polarization. We extracted the structure factor of hydrogen atoms from the variation of peak intensities.

Journal Articles

High spatial resolution neutron transmission imaging using a superconducting two-dimensional detector

Shishido, Hiroaki*; Nishimura, Kazuma*; Vu, TheDang*; Aizawa, Kazuya; Kojima, Kenji M*; Koyama, Tomio*; Oikawa, Kenichi; Harada, Masahide; Oku, Takayuki; Soyama, Kazuhiko; et al.

IEEE Transactions on Applied Superconductivity, 31(9), p.2400505_1 - 2400505_5, 2021/12

 Times Cited Count:0 Percentile:0(Engineering, Electrical & Electronic)

In this study, we employed a superconducting detector, current-biased kinetic-inductance detector (CB-KID) for neutron imaging using a pulsed neutron source. We employed the delay-line method, and high spatial resolution imaging with only four reading channels was achieved. We also performed wavelength-resolved neutron imaging by the time-of-flight method. We obtained the neutron transmission images of a Gd-Al alloy sample, inside which single crystals of GdAl$$_{3}$$ were grown, using the delay-line CB-KID. Single crystals were well imaged, in both shapes and distributions, throughout the Al-Gd alloy. We identified Gd nuclei via neutron transmissions that exhibited characteristic suppression above the neutron wavelength of 0.03 nm. In addition, the $$_{155}$$Gd resonance dip, a dip structure of the transmission caused by the nuclear reaction between an isotope and neutrons, was observed even when the number of events was summed over a limited area of 15 $$mu$$m $$times$$ 12 $$mu$$m. Gd selective imaging was performed using the resonance dip of $$_{155}$$Gd, and it showed clear Gd distribution even with a limited neutron wavelength range of 1 pm.

Journal Articles

Practical tests of neutron transmission imaging with a superconducting kinetic-inductance sensor

Vu, TheDang; Shishido, Hiroaki*; Aizawa, Kazuya; Kojima, Kenji M*; Koyama, Tomio*; Oikawa, Kenichi; Harada, Masahide; Oku, Takayuki; Soyama, Kazuhiko; Miyajima, Shigeyuki*; et al.

Nuclear Instruments and Methods in Physics Research A, 1006, p.165411_1 - 165411_8, 2021/08

 Times Cited Count:1 Percentile:18.91(Instruments & Instrumentation)

Journal Articles

Polarization analysis for small-angle neutron scattering with a $$^{3}$$He spin filter at a pulsed neutron source

Okudaira, Takuya; Ueda, Yuki; Hiroi, Kosuke; Motokawa, Ryuhei; Inamura, Yasuhiro; Takata, Shinichi; Oku, Takayuki; Suzuki, Junichi*; Takahashi, Shingo*; Endo, Hitoshi*; et al.

Journal of Applied Crystallography, 54(2), p.548 - 556, 2021/04

 Times Cited Count:2 Percentile:33.1(Chemistry, Multidisciplinary)

Neutron polarization analysis (NPA) for small-angle neutron scattering (SANS) experiments using a pulsed neutron source was successfully achieved by applying a $$^{3}$$He spin filter as a spin analyzer for the scattered neutrons. The $$^{3}$$He spin filter covers a sufficient solid angle for performing SANS experiments, and the relaxation time of the $$^{3}$$He polarization is sufficient for continuous use over a few days, thus reaching the typical duration required for a complete set of SANS experiments. Although accurate evaluation of the incoherent neutron scattering, which is predominantly attributable to hydrogen atoms in samples, is practically difficult using calculations based on the sample elemental composition, the developed NPA approach with consideration of the influence of multiple neutron scattering enabled reliable decomposition of the SANS intensity distribution into the coherent and incoherent scattering components. To date, NPA has not been well established as a standard technique for SANS experiments at pulsed neutron sources. This work is anticipated to greatly contribute to the accurate determination of the coherent neutron scattering component for scatterers in various types of organic sample systems in SANS experiments at J-PARC.

Journal Articles

Study of neutron-nuclear spin correlation term with a polarized Xe target

Sakai, Kenji; Oku, Takayuki; Okudaira, Takuya; Kai, Tetsuya; Harada, Masahide; Hiroi, Kosuke; Hayashida, Hirotoshi*; Kakurai, Kazuhisa*; Shimizu, Hirohiko*; Hirota, Katsuya*; et al.

JPS Conference Proceedings (Internet), 33, p.011116_1 - 011116_6, 2021/03

In neutron fundamental physics, study of correlation term $${bf s}cdot{bf I}$$ of a neutron spin $${bf s}$$ and a target nuclear spin $${bf I}$$ is important because $${bf s}cdot{bf I}$$ term interferes to parity non-conserving (PNC) and time reversal non-conserving terms. For this study, a xenon (Xe) is an interesting nucleus because it has been observed an enhancement of PNC effect around neutron resonance peaks, and polarizes up to $$ sim 10^{-1}$$ by using a spin exchange optical pumping (SEOP) method. We would plan to develop a polarized Xe gas target with a compact in-situ SEOP system, and to study $${bf s}cdot{bf I}$$ term by utilizing epithermal neutron beams supplied from a high intense pulsed spallation neutron source. As the first step, we attempted to measure neutron polarizing ability caused by $${bf s}cdot{bf I}$$ term at a 9.6 eV s-wave resonance peak of $$^{129}$$Xe at BL10 in MLF, by detecting change $$Delta R$$ of ratio between neutron transmissions with the polarized and unpolarized Xe target. After demonstrating that our apparatus could detect small change ($$Delta R_{rm DB} , {approx},10^{-2}$$) of neutron transmissions caused by Doppler broadening effect, a signified value of $$Delta R$$ has been obtained as preliminary results. For analyzing the obtained $$Delta R$$ in detail, we are improving our nuclear magnetic resonance and electron paramagnetic resonance systems for evaluating Xe polarization independently of neutron beams.

Journal Articles

Homogeneity of neutron transmission imaging over a large sensitive area with a four-channel superconducting detector

Vu, TheDang; Shishido, Hiroaki*; Kojima, Kenji M*; Koyama, Tomio*; Oikawa, Kenichi; Harada, Masahide; Miyajima, Shigeyuki*; Oku, Takayuki; Soyama, Kazuhiko; Aizawa, Kazuya; et al.

Superconductor Science and Technology, 34(1), p.015010_1 - 015010_10, 2021/01

 Times Cited Count:3 Percentile:27.71(Physics, Applied)

Journal Articles

Energy-resolved neutron imaging using a delay line current-biased kinetic-inductance detector

Shishido, Hiroaki*; Nishimura, Kazuma*; Vu, TheDang*; Kojima, Kenji M*; Koyama, Tomio*; Oikawa, Kenichi; Harada, Masahide; Miyajima, Shigeyuki*; Hidaka, Mutsuo*; Oku, Takayuki; et al.

Journal of Physics; Conference Series, 1590, p.012033_1 - 012033_8, 2020/10

 Times Cited Count:0 Percentile:0.01(Engineering, Electrical & Electronic)

Journal Articles

Development and application of a $$^3$$He neutron spin filter at J-PARC

Okudaira, Takuya; Oku, Takayuki; Ino, Takashi*; Hayashida, Hirotoshi*; Kira, Hiroshi*; Sakai, Kenji; Hiroi, Kosuke; Takahashi, Shingo*; Aizawa, Kazuya; Endo, Hitoshi*; et al.

Nuclear Instruments and Methods in Physics Research A, 977, p.164301_1 - 164301_8, 2020/10

 Times Cited Count:10 Percentile:79.13(Instruments & Instrumentation)

Journal Articles

Kinetic inductance neutron detector operated at near critical temperature

Vu, TheDang; Nishimura, Kazuma*; Shishido, Hiroaki*; Harada, Masahide; Oikawa, Kenichi; Miyajima, Shigeyuki*; Hidaka, Mutsuo*; Oku, Takayuki; Soyama, Kazuhiko; Aizawa, Kazuya; et al.

Journal of Physics; Conference Series, 1590, p.012036_1 - 012036_9, 2020/07

 Times Cited Count:0 Percentile:0.01(Engineering, Electrical & Electronic)

Journal Articles

Transverse asymmetry of $$gamma$$ rays from neutron-induced compound states of $$^{140}$$La

Yamamoto, Tomoki*; Okudaira, Takuya; Endo, Shunsuke; Fujioka, Hiroyuki*; Hirota, Katsuya*; Ino, Takashi*; Ishizaki, Kohei*; Kimura, Atsushi; Kitaguchi, Masaaki*; Koga, Jun*; et al.

Physical Review C, 101(6), p.064624_1 - 064624_8, 2020/06

 Times Cited Count:9 Percentile:73.66(Physics, Nuclear)

Journal Articles

Measurement of the angular distribution of $$gamma$$-rays after neutron capture by $$^{139}$$La for a T-violation search

Okudaira, Takuya; Shimizu, Hirohiko*; Kitaguchi, Masaaki*; Hirota, Katsuya*; Haddock, C. C.*; Ito, Ikuya*; Yamamoto, Tomoki*; Endo, Shunsuke*; Ishizaki, Kohei*; Sato, Takumi*; et al.

EPJ Web of Conferences, 219, p.09001_1 - 09001_6, 2019/12

Parity violating effects enhanced by up to 10$$^6$$ times have been observed in several neutron induced compound nuclei. There is a theoretical prediction that time reversal (T) violating effects can also be enhanced in these nuclei implying that T-violation can be searched for by making very sensitive measurements. However, the enhancement factor has not yet been measured in all nuclei. The angular distribution of the (n,$$gamma$$) reaction was measured with $$^{139}$$La by using a germanium detector assembly at J-PARC, and the enhancement factor was obtained. From the result, the measurement time to achieve the most sensitive T-violation search was estimated as 1.4 days, and a 40% polarized $$^{139}$$La target and a 70% polarized $$^3$$He spin filter whose thickness is 70 atm$$cdot$$cm are needed. Therefore high quality $$^3$$He spin filter is developed in JAEA. The measurement result of the (n,$$gamma$$) reaction at J-PARC and the development status of the $$^3$$He spin filter will be presented.

Journal Articles

Development of the neutron polarizer for the T-violation search using compound nuclei

Okudaira, Takuya; Oku, Takayuki; Sakai, Kenji; Ino, Takashi*; Hayashida, Hirotoshi*; Hiroi, Kosuke; Shinohara, Takenao; Kakurai, Kazuhisa*; Aizawa, Kazuya; Shimizu, Hirohiko*; et al.

Proceedings of Science (Internet), 356, p.029_1 - 029_5, 2019/12

The technology development section carries out the development of the neutron polarization device: $$^{3}$$He Spin Filter. It is often used for the fundamental physics region. In order to explain the matter-dominated universe, a time reversal violation is necessary and searches for new physics are conducted in the world. The T-violation search using a polarized neutron beam is planned at J-PARC. A large $$^{3}$$He spin filter is needed to polarize high energy neutrons for the experiment and is developed in JAEA. Recently, we developed the accurate measurement system to evaluate the polarization of $$^{3}$$He and a vacuum system to make the $$^{3}$$He spin filter, and large $$^{3}$$He spin filters for epi-thermal neutron was made using the system. The current status of the development of the $$^{3}$$He spin filter will be talked.

Journal Articles

Energy-resolved neutron imaging with high spatial resolution using a superconducting delay-line kinetic inductance detector

Iizawa, Yuki*; Shishido, Hiroaki*; Nishimura, Kazuma*; Vu, TheDang*; Kojima, Kenji M*; Koyama, Tomio*; Oikawa, Kenichi; Harada, Masahide; Miyajima, Shigeyuki*; Hidaka, Mutsuo*; et al.

Superconductor Science and Technology, 32(12), p.125009_1 - 125009_8, 2019/12

 Times Cited Count:13 Percentile:59.07(Physics, Applied)

191 (Records 1-20 displayed on this page)