Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
; Ohno, Shuji;
JNC TN2400 2000-006, 56 Pages, 2000/12
Sodium combustion analyses were performed using ASSCOPS version 2.1 in order to obtain background data for evaluating the validity of the mitigation system against secondary sodium leak of MONJU. The calculated results are summarized as follows. (1)Peak atmospheric pressure 4.3 kPa[gage] (2)Peak floor liner temperature 870C, Maximum thinning of liner 2.6mm (3)Peak hydrogen concentration <2% (4)Peak floor liner temperature in the spilt sodium storage eell 400C , Peak floor concrete temperature in the spilt sodium storage cell 140C.