Refine your search:     
Report No.
 - 
Search Results: Records 1-3 displayed on this page of 3
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

The Way of maintenance to keep log-term accuracy and a sign of malfunction of digiquartz differential pressure transducer used for accurate level measurement system

Mukai, Yasunobu; Koiso, Katsuya; Nakamura, Hironobu; Hosoma, Takashi; Yoshimoto, Katsunobu; Hayashi, Hiroyuki*

Kaku Busshitsu Kanri Gakkai (INMM) Nihon Shibu Dai-30-Kai Nenji Taikai Rombunshu (CD-ROM), 9 Pages, 2009/11

Electro manometer (ELTM) is a device to measure accurately level, density and volume in an accountability tank for the purpose of nuclear materials accountancy, safeguards and operational control. JAEA have developed and put the ELTM using digiquartz differential pressure transducer into practical use at plutonium conversion development facility since initial tank calibration in 1982. As a result of calibrations and measurements in the last 15 years, the sustainable measurement accuracy is $$pm$$2 Pa as a sigma of difference from the standard pressure and $$pm$$ 0.002 g/cm$$^{3}$$ as a sigma of difference from the solution density analytically determined. However, a drift of data we have never experienced was found in 2008. After investigations, a characteristic value T$$_{0}$$ (period of vibration at zero pressure) which is stable in normal state had changed around 7% at the drift. This was the result of aging, so it was found that monitoring of T$$_{0}$$ value was the very effective information to know the timing of replacement of the transducer. We will present the long-term measurement accuracy of ELTM practically achieved and the way of maintenance including a replacement of the transducer.

Oral presentation

Method of radiation exposure management regarding hands for glove operation by using glass dosimeter and the irradiation characteristic results

Isomae, Hidemi; Nakamura, Hironobu; Matsumoto, Masaki; Kato, Yoshiyuki; Nakamichi, Hideo; Koiso, Katsuya*; Shoji, Kaoru*

no journal, , 

Ring monitor by glass dosimeter was designed and applied to the radiation management for glove box operation. The radiation management method and the irradiation test results are introduced in this report.

Oral presentation

Test of neutralization treatment for radioactive liquid waste by using sodium hydroxide, 2; Confirmation of decontamination effects by neutralization

Fujiwara, Hideki*; Kamoshida, Shuichi*; Sugaya, Shinichi*; Nakamura, Hironobu; Koiso, Katsuya; Yoshimoto, Katsunobu

no journal, , 

no abstracts in English

3 (Records 1-3 displayed on this page)
  • 1