Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 86

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Estimation of relative biological effectiveness for boron neutron capture therapy using the PHITS code coupled with a microdosimetric kinetic model

Horiguchi, Hironori*; Sato, Tatsuhiko; Kumada, Hiroaki*; Yamamoto, Tetsuya*; Sakae, Takeji*

Journal of Radiation Research, 56(2), p.382 - 390, 2015/03

 Times Cited Count:23 Percentile:69.26(Biology)

For evaluating the irradiation effect in tumors and surrounding normal tissues in BNCT, it is of great importance to estimate the relative biological effectiveness (RBE) for each dose component in the same framework. We have therefore established a new method for estimating the RBE of all BNCT dose components on the basis of the microdosimetric kinetic model. This method employs the probability densities of lineal energy, y, in a subcellular structure as the index for expressing RBE, which can be calculated using the microdosimetric function implemented in the particle transport simulation code PHITS. The accuracy of this method was tested by comparing the calculated RBE values with corresponding measured data in a water phantom irradiated with an epithermal neutron beam. The calculation technique developed in this study will be useful for biological dose estimation in the treatment planning of BNCT.

Journal Articles

Observation of the laser-induced surface dynamics using the single-shot soft X-ray laser probe

Hasegawa, Noboru; Ochi, Yoshihiro; Kawachi, Tetsuya; Nishikino, Masaharu; Ishino, Masahiko; Imazono, Takashi; Kaihori, Takeshi; Morita, Toshimasa; Sasaki, Akira; Terakawa, Kota*; et al.

X-Ray Lasers 2012; Springer Proceedings in Physics, Vol.147, p.117 - 120, 2014/00

 Times Cited Count:0 Percentile:0(Engineering, Electrical & Electronic)

We have developed the femto-second laser pump and soft X-ray laser probe system in order to observe the dynamical processes of the femto-second laser ablation. By using this system, we succeed to obtain the temporal evolution of the soft X-ray reflectivity from the laser induced Pt surface. The results lead that the rate of decrease in the reflectivity of the probe beam has a non-linear relation with the pump laser fluence.

Journal Articles

Measurement of femtosecond laser ablation by soft X-ray laser interferometory and reflective imaging

Nishikino, Masaharu; Hasegawa, Noboru; Ishino, Masahiko; Yamagiwa, Mitsuru; Kawachi, Tetsuya; Minami, Yasuo*; Terakawa, Kota*; Takei, Ryota*; Baba, Motoyoshi*; Suemoto, Toru; et al.

JAEA-Conf 2013-001, p.16 - 19, 2013/09

The dynamics of the femtosecond laser ablation is still not clear at the early stage. Several studies on the time-resolved imaging of femtosecond laser ablation process have been performed on various materials. In this study, we have demonstrated a pump and probe imaging of the metal surface morphology during the femtosecond laser ablation by using the laser-driven plasma induced soft X-ray laser (SXRL) as a probe beam. The pumping laser used for ablation was a Ti:Sapphire laser system based on chirped pulse amplification. The pump beam had a Gaussian profile and the focal spot size on the metal surface was about 70 micron at FWHM. The dependence for the pump laser fluence of the ablation surface expansion and the surface condition (roughness and density gradient) were observed from the soft X-ray interferogram and reflective image, respectively.

Journal Articles

Experimental verification of femtosecond laser ablation schemes by time-resolved soft X-ray reflective imaging

Tomita, Takuro*; Yamamoto, Minoru*; Hasegawa, Noboru; Terakawa, Kota*; Minami, Yasuo*; Nishikino, Masaharu; Ishino, Masahiko; Kaihori, Takeshi*; Ochi, Yoshihiro; Kawachi, Tetsuya; et al.

Optics Express (Internet), 20(28), p.29329 - 29337, 2012/12

 Times Cited Count:19 Percentile:64.97(Optics)

Pump and probe reflective imaging using a soft X-ray laser probe was applied to the observation of the early stage of femtosecond laser ablation process on platinum. In strongly excited area, drastic and fast reflectivity drop was observed. In moderately excited area, the decay of the reflectivity is slower than that in the strongly excited area, and the reflectivity reaches its minimum at t = 160 ps. In weakly excited area, laser-induced reflectivity change was not observed. These results give the critical information about the femtosecond laser ablation.

Journal Articles

Development of the X-ray interferometer and the method of temporal synchronization of X-ray and optical pulse

Hasegawa, Noboru; Yamamoto, Minoru*; Terakawa, Kota*; Nishikino, Masaharu; Ochi, Yoshihiro; Minami, Yasuo*; Tomita, Takuro*; Kawachi, Tetsuya; Suemoto, Toru

AIP Conference Proceedings 1465, p.23 - 27, 2012/07

 Times Cited Count:0 Percentile:0.13(Physics, Applied)

We have developed a soft X-ray laser (SXRL) interferometer capable of the single-shot imaging of nano-scaled structure dynamics. The depth and lateral resolutions of the interferometer were about 1 nm and 1.8 micron, respectively. We observed the initial stage ($$sim$$50 ps) of the ablation process of the Pt surface pumped by a 70 fs Ti:Sapphire laser pulse. The expansion speed of the Pt surface (34 nm/50 ps) indicated that the nano-bubble structures were formed in the initial stage of the ablation. In order to observe the detailed dynamics, the precision of temporal synchronization between the pump and probe pulses was improved to be 3 ps by adopting a portion of the SXRL and pump beams as the time fiducials.

Journal Articles

The Analysis of boron micro-distribution in 9L gliosarmoma cells and HUVEC cells using PIXE and PIGE

Endo, Kiyoshi*; Shibata, Yasushi*; Yamamoto, Tetsuya*; Nakai, Kei*; Matsumura, Akira*; Sato, Takahiro; Yokoyama, Akihito; Koka, Masashi; Okubo, Takeru; Yamazaki, Akiyoshi; et al.

JAEA-Review 2011-043, JAEA Takasaki Annual Report 2010, P. 86, 2012/01

Journal Articles

Picosecond soft-X-ray laser interferometer for probing nanometer surface structure

Ochi, Yoshihiro; Terakawa, Kota*; Hasegawa, Noboru; Yamamoto, Minoru*; Tomita, Takuro*; Kawachi, Tetsuya; Minami, Yasuo*; Nishikino, Masaharu; Imazono, Takashi; Ishino, Masahiko; et al.

Japanese Journal of Applied Physics, 51(1), p.016601_1 - 016601_3, 2012/01

 Times Cited Count:10 Percentile:40.61(Physics, Applied)

We have developed a soft X-ray laser interferometer based on the double Lloyd's mirror and obtained a single shot interferogram by a 7-ps pulse at the wavelength of 13.9 nm. Micrometer grooves with 5-nm depth were successfully reconstructed from the interferogram. The lateral and depth resolutions were estimated to be 1.5 $$mu$$m and better than 1 nm, respectively. This interferometer will be an attractive diagnostic device for observing transiently changing nano-scale deviations on solid surfaces.

Journal Articles

Source development and novel applications of laser-driven plasma X-ray lasers in JAEA

Kawachi, Tetsuya; Hasegawa, Noboru; Nishikino, Masaharu; Ishino, Masahiko; Imazono, Takashi; Oba, Toshiyuki; Kaihori, Takeshi; Kishimoto, Maki; Ochi, Yoshihiro; Tanaka, Momoko; et al.

X-Ray Lasers 2010; Springer Proceedings in Physics, Vol.136, p.15 - 24, 2011/12

This paper reviews recent improvement in the source development of laser-driven X-ray lasers and the applications in the research fields of material science, laser processing, X-ray imaging, and radiation damage in biological cells. In the application for material science, we have firstly observed temporal correlation between the domain structures of ferro-electric substance under the Curie temperature. In the laser processing, new X-ray laser interferometer reveals us the nano-scale surface distortion of substance pumped by a femto-second optical pulse. In the X-ray diffraction image, we have taken several static images of micro-structure of samples: now we are trying to extend the objective to nano-scale dynamics using pump and probe method. In the radiation damage of biological cells, we observed double strand break in DNA using X-ray laser exposure; this results are compared with the case using incoherent several KeV X-ray exposure.

Journal Articles

Development of the X-ray interferometer and the method of spatial and temporal synchronization of XRL and optical pulse

Hasegawa, Noboru; Ochi, Yoshihiro; Kawachi, Tetsuya; Terakawa, Kota*; Tomita, Takuro*; Yamamoto, Minoru; Nishikino, Masaharu; Oba, Toshiyuki; Kaihori, Takeshi; Imazono, Takashi; et al.

X-Ray Lasers 2010; Springer Proceedings in Physics, Vol.136, p.353 - 358, 2011/12

The understanding of the dynamics of the initial process is important for the micro processing and welding by the ultra-short laser pulse. The X-ray laser is suitable for probing this initial process because it has short wavelength (Ni-like Ag, 13.9 nm) and short duration (7 ps). For this investigation, the origin of time of the pumping pulse is quite important. In this study, we used the scintillation plate and the plasma gate technique to realize the spatial and temporal synchronization of the pump and probe pulses. For the spatial alignment, a CsI scintillation plate that was set at the sample position was illuminated by both the X-ray laser pulse, and the fluorescence light were detected by the CCD camera. For the temporal synchronization, we set a thin foil at the sample position. We measured the transmission of the X-ray laser while changing a temporal delay of the pumping laser with respect to the time of X-ray laser pulse to obtain the origin of the irradiation time.

Journal Articles

Observation of the laser-induced surface dynamics by the single-shot X-ray laser interferometer

Hasegawa, Noboru; Ochi, Yoshihiro; Kawachi, Tetsuya; Nishikino, Masaharu; Ishino, Masahiko; Imazono, Takashi; Kaihori, Takeshi; Sasaki, Akira; Terakawa, Kota*; Minami, Yasuo*; et al.

Proceedings of SPIE, Vol.8140, p.81400G_1 - 81400G_8, 2011/10

 Times Cited Count:3 Percentile:82.2(Engineering, Electrical & Electronic)

We have developed a soft X-ray laser (SXRL) interferometer capable of the single-shot imaging of nano-scaled structure dynamics. The interferometer consisted of the reflection optics including double Lloyd's mirrors and focusing optics, and the interference fringes are produced on the detector surface. By using this interferometer, the initial stage ($$sim$$50 ps) of the ablation process of the Pt surface pumped by a 70 fs Ti:Sapphire laser pulse was observed. The expansion speed of the surface estimated from the result (34 nm/50 ps) indicated that the nano-bubble structures were formed in the initial stage of the ablation. In order to observe the detailed dynamics, the temporal synchronization between the pump and probe pulses was improved to be 3 ps by adopting a portion of the SXRL and pump beams as the time fiducials, to which the pump and probe timing was adjusted by using the X-ray streak camera.

Journal Articles

Development of a specimen holder combined with ultra thin film laser plasma X-ray source for compact contact-type soft X-ray microscope to observe hydrated living biologocal cells

Ishino, Masahiko; Kado, Masataka; Shinohara, Kunio*; Yamamoto, Yoshimasa*; Hirai, Itaru*; Kishimoto, Maki; Nishikino, Masaharu; Hasegawa, Noboru; Tamotsu, Satoshi*; Yasuda, Keiko*; et al.

Proceedings of SPIE Europe Optics + Optoelectronics 2011, Vol.8139, p.81390R_1 - 81390R_8, 2011/09

 Times Cited Count:0 Percentile:0.01(Optics)

Ultra thin gold films are favorable laser plasma targets for a soft X-ray microscopy, because the thin films emit intense soft X-rays at the wavelength of water window region. Using rear side emissions, the distance between the X-ray source and the specimens can be reduced so that the X-ray flux on specimens increases. The microscope system can be designed to be compact when the specimen holder and X-ray source are combined in one piece. The biological specimen holder combined with an ultra thin film target has been developed. This X-ray microscope system needs not any X-ray optics which causes a decrease in X-ray photons for imaging. X-ray images of hydrated living cells have been obtained successfully by use of the newly developed specimen holder. Specimen holder combined with plasma X-ray source will be a key component of a compact soft X-ray microscope using in a laboratory.

Journal Articles

Observation of femtosecond laser ablation process by using the soft X-ray laser interferometer

Yamamoto, Minoru; Hasegawa, Noboru; Terakawa, Kota*; Umeda, Yoshifumi*; Tomita, Takuro*; Ochi, Yoshihiro; Nishikino, Masaharu; Ishino, Masahiko; Imazono, Takashi; Kaihori, Takeshi; et al.

Proceedings of 12th International Symposium on Laser Precision Microfabrication (LPM 2011) (Internet), 4 Pages, 2011/06

Femtosecond lasers have been used for material processing. However, the physical processes responsible for femtosecond laser ablation have not been understood completely. These processes involve melting, vaporization, re-solidification or ablation, which occur in a very short time from pico- to nano-seconds. To understand the physical processes, it is essential to reveal the dynamics of ultrafast surface morphological change after laser irradiation. At JAEA, the laser-driven plasma soft X-ray laser (SXRL) that has extremely high spatial and spectral purity was constructed. It delivers soft X-ray photons at 89.2 eV (13.9 nm) with a photon number of exceeding $$10^{10}$$, which is sufficient to obtain a single shot interferogram. By using this system, the soft X-ray laser interferometer with the lateral resolution of 1.8 $$mu$$m and a depth resolution of 1 nm was developed. We report on demonstration of time-resolved measurement of femtosecond-laser ablation dynamics by using the soft X-ray laser interferometer.

Journal Articles

Single-shot picosecond interferometry with one-nanometer resolution for dynamical surface morphology using a soft X-ray laser

Suemoto, Toru; Terakawa, Kota*; Ochi, Yoshihiro; Tomita, Takuro*; Yamamoto, Minoru; Hasegawa, Noboru; Deki, Manato*; Minami, Yasuo*; Kawachi, Tetsuya

Optics Express (Internet), 18(13), p.14114 - 14122, 2010/06

 Times Cited Count:33 Percentile:80.1(Optics)

Using highly coherent radiation at a wavelength of 13.9 nm from a Ag-plasma soft X-ray laser, we constructed a pump-and-probe interferometer based on a double Lloyd's mirror system. The spatial resolutions are evaluated with a test pattern, showing 1.8 micrometers lateral resolution, and 1-nm depth sensitivity. This instrument enables a single-shot observation of the surface morphology with a 7-ps time-resolution. We succeeded in observing a nanometer scale surface dilation of Pt films at the early stage of the ablation process initiated by a 70 fs near infrared pump pulse.

Journal Articles

Development of JCDS, a computational dosimetry system at JAEA for boron neutron capture therapy

Kumada, Hiroaki; Yamamoto, Kazuyoshi; Matsumura, Akira*; Yamamoto, Tetsuya*; Nakagawa, Yoshinobu*

Journal of Physics; Conference Series, 74, p.021010_1 - 021010_7, 2007/00

no abstracts in English

Journal Articles

Failure patterns of high-grade glioma treated with BNCT

Matsuda, Masahide*; Yamamoto, Tetsuya*; Nakai, Kei*; Endo, Kiyoshi*; Kumada, Hiroaki; Kageji, Teruyoshi*; Matsumura, Akira*

Proceedings of 12th International Congress on Neutron Capture Therapy (ICNCT-12), p.40 - 42, 2006/10

To describe the failure patterns and survival seen with high-grade glioma treated with BNCT, the dose distribution and the clinical responses were retrospectively analyzed. BSH-based BNCT was performed in 12 patients with high-grade glioma (grade IV 7, grade III 5). The post-diagnosis median survival time of 12 patients was 19.8 months (range 3.3-47.2). Four cases of local control, 3 of local recurrence, 3 of distant intraparenchymal recurrence and 2 of subarachnoid dissemination were recorded. According to the analysis of the failure patterns, minimum GTV dose of 26 GyEq or more is necessary for local control.

Journal Articles

Development of a real-time thermal neutron monitor and its clinical application

Ishikawa, Masayori*; Ono, Koji*; Matsumura, Akira*; Yamamoto, Tetsuya*; Hiratsuka, Junichi*; Miyatake, Shinichi*; Kato, Itsuro*; Sakurai, Yoshinori*; Kobayashi, Toru*; Kumada, Hiroaki; et al.

Proceedings of 12th International Congress on Neutron Capture Therapy (ICNCT-12), p.397 - 400, 2006/10

An ultraminiature thermal neutron monitor which was named SOF detector (Scintillator with Optical Fiber detector) had been developed for BNCT treatment. We had been experienced 15 clinical trials using SOF detector until the end of 2005, some measurements got good results, and some got unacceptable results. One reason of the unacceptable results was due to dislocation of the detector during treatment. This is because it is difficult to fix the SOF detector on patient's skin without strong sticker. To overcome this problem, a loop-type SOF probe was developed. By using the loop-type SOF detector, fixing on the patient's skin was much easier.

JAEA Reports

Estimation methods of blood boron concentration and error evaluation during boron neutron capture therapy for malignant brain tumor

Shibata, Yasushi*; Yamamoto, Kazuyoshi; Matsumura, Akira*; Yamamoto, Tetsuya*; Hori, Naohiko; Kishi, Toshiaki; Kumada, Hiroaki; Akutsu, Hiroyoshi*; Yasuda, Susumu*; Nakai, Kei*; et al.

JAERI-Research 2005-009, 41 Pages, 2005/03

JAERI-Research-2005-009.pdf:1.99MB

The measurement of neutron flux and boron concentration in the blood during medical irradiation is indispensable in order to evaluate the radiation in boron neutron capture therapy. It is, however, difficult to measure the blood boron concentration during neutron irradiation because access to the patient is limited. Therefore we prospectively investigated the predictability of blood boron concentrations using the data obtained at the first craniotomy after infusion of a low dosage of BSH. When the test could not be carried out, the blood boron concentration during irradiation was also predicted by using the 2-compartment model. If the final boron concentration after the end of the infusion is within 95% confidence interval of the prediction, direct prediction from biexponential fit will reduce the error of blood boron concentrations during irradiation to around 6%. If the final boron concentration at 6 or 9 hours after the end of infusion is out of 95% confidence interval of the prediction, proportional adjustment will reduce error and expected error after adjustment to around 12%.

Journal Articles

Combination of boron and gadolinium compounds for neutron capture therapy; An $$in Vitro$$ study

Matsumura, Akira*; Zhang, T.*; Nakai, Kei*; Endo, Kiyoshi*; Kumada, Hiroaki; Yamamoto, Tetsuya*; Yoshida, Fumiyo*; Sakurai, Yoshinori*; Yamamoto, Kazuyoshi; Nose, Tadao*

Journal of Experimental and Clinical Cancer Research, 24(1), p.93 - 98, 2005/03

no abstracts in English

Journal Articles

Improvement of dose calculation accuracy for BNCT dosimetry by the multi-voxel method in JCDS

Kumada, Hiroaki; Yamamoto, Kazuyoshi; Yamamoto, Tetsuya*; Nakai, Kei*; Nakagawa, Yoshinobu*; Kageji, Teruyoshi*; Matsumura, Akira*

Applied Radiation and Isotopes, 61(5), p.1045 - 1050, 2004/11

 Times Cited Count:12 Percentile:61.53(Chemistry, Inorganic & Nuclear)

To carry out the BNCT clinical trials based on accurate dosimetry of several absorbed doses given to a patient, we have developed JCDS which can determine the absorbed doses by numerical simulation. The aim of this study is to improve the accuracy of the BNCT dosimetry efficiently. We have developed the multi-voxel calculation method reconstructing the original voxel model by combining of several voxel cell sizes such as in 5mm, 10mm and 20mm voxel cell. To verify the accuracy of the multi-voxel method, the calculation results were compared with the phantom experimental data. These results proved that the multi-voxel calculation enables JCDS to more accurately estimate the absorbed doses to a patient by efficient calculations.

Journal Articles

Enhancement of sodium borocaptate (BSH) uptake by tumor cells induced by glutathione depletion and its radiobiological effect

Yoshida, Fumiyo*; Matsumura, Akira*; Yamamoto, Tetsuya*; Kumada, Hiroaki; Nakai, Kei*

Cancer Letters, 215(1), p.61 - 67, 2004/11

 Times Cited Count:13 Percentile:22.46(Oncology)

Sodium borocaptate (BSH) is widely used for Boron Neutron Capture Therapy (BNCT) of brain tumors. However, the mechanism of uptake by the tumor remains unclear. We investigated the sulfhydryl moiety of this compound. Down regulation of glutathione (GSH) by buthionine sulfoximine (BSO) in cultured cells resulted in increase of BSH uptake (7.9 %-36.5 %) compared to control group and subsequently cytocidal effect of neutron irradiation also increased. The radiation damage by $$gamma$$-ray irradiation was suppressed by enhancement of BSH uptake. These findings suggested that modulation of GSH induce enhancement effect of B(n,$$alpha$$) reaction and protective effect of secondary $$gamma$$-ray in BNCT.

86 (Records 1-20 displayed on this page)