Refine your search:     
Report No.
 - 
Search Results: Records 1-4 displayed on this page of 4
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Development of in-reactor observation system using Cherenkov light(VI)

Takeuchi, Tomoaki; Yamamoto, Keiichi; Otsuka, Noriaki; Shibata, Hiroshi; Shibata, Akira; Takemoto, Noriyuki; Tsuchiya, Kunihiko; Sano, Tadafumi*; Unesaki, Hironobu*; Fujihara, Yasuyuki*; et al.

KURRI Progress Report 2014, P. 108, 2015/07

Investigation of a relation between output power and brightness of Cherenkov light of a specific fuel element at KUR by a CCD camera was performed due to a development of a real-time in-core measurement technique using Cherenkov light. The results indicate that the inhomogeneous distribution of output power and the shadow of the control-rod guide tubes and the other irradiation equipment have significant effects on the brightness of the Cherenkov light. These effects could be suppressed by using a number of cameras located at various positions.

Journal Articles

Development of in-reactor observation system using Cherenkov light, 5

Otsuka, Noriaki; Takeuchi, Tomoaki; Yamamoto, Keiichi; Shibata, Akira; Kimura, Nobuaki; Takemoto, Noriyuki; Tanimoto, Masataka; Tsuchiya, Kunihiko; Sano, Tadafumi*; Unesaki, Hironobu*; et al.

KURRI Progress Report 2013, P. 215, 2014/10

Investigation of a relation between reactor power and brightness of Cherenkov light at Kyoto University Research reactor (KUR) by a CCD camera was performed due to a development of a real-time in-core measurement technique using Cherenkov light. Analyzing the brightness value of individual RGB color component at each pixel, some of the G and B brightness values reached the maximum value of 8-bit binary number, i.e. 255, above about 2-3 MW. Therefore, we corrected the G and B brightness values by the R signals whose brightness value did not saturate even at 5 MW, the maximum reactor power of KUR. Then, the total brightness value was in proportion to the reactor power after the correction. These results indicate the reactor power can be estimated by the observation of Cherenkov light.

Journal Articles

Development of in-reactor observation system using Cherenkov light, 4

Kimura, Nobuaki; Takeuchi, Tomoaki; Shibata, Akira; Takemoto, Noriyuki; Kimura, Akihiro; Naka, Michihiro; Nishikata, Kaori; Tanimoto, Masataka; Tsuchiya, Kunihiko; Sano, Tadafumi*; et al.

KURRI Progress Report 2012, P. 209, 2013/10

In research reactors, CCD cameras are used to observe reactor core for reactor operation management, e.g. to prevent debris from falling. In order to measure the reactor power and fuel burnup exactly by means of observation of Cherenkov light, the development of the on-line measurement device started in 2009. In this study, the wavelength and the absolute irradiance of the Cherenkov light were measured by a spectrometer, and the Cherenkov light was observed by the CCD camera. As a result, the measurement value is good agreement with the nominal value. On the other hand, the value by the visible imaging system was obtained the same tendency of nominal transmittance value of ND-filters.

Journal Articles

Deuterium ion irradiation for tritium breeding material and evaluation for tritium inventories in test blanket module and blanket of a demonstration reactor

Hino, Tomoaki*; Shibata, Hironobu*; Yamauchi, Yuji*; Nobuta, Yuji*; Suzuki, Satoshi; Akiba, Masato

Journal of Nuclear Materials, 417(1-3), p.713 - 717, 2011/10

 Times Cited Count:8 Percentile:53.23(Materials Science, Multidisciplinary)

4 (Records 1-4 displayed on this page)