Journal Articles

Oxidation and embrittlement behavior of FeCrAl-ODS cladding tube under loss-of-coolant accident conditions

Narukawa, Takafumi; Kondo, Keietsu; Fujimura, Yuki; Kakiuchi, Kazuo; Udagawa, Yutaka; Nemoto, Yoshiyuki

Journal of Nuclear Materials, 587, p.154736_1 - 154736_8, 2023/12

 Times Cited Count:1 Percentile:0.01(Materials Science, Multidisciplinary)

Journal Articles

Behavior of FeCrAl-ODS cladding tube under loss-of-coolant accident conditions

Narukawa, Takafumi; Kondo, Keietsu; Fujimura, Yuki; Kakiuchi, Kazuo; Udagawa, Yutaka; Nemoto, Yoshiyuki

Journal of Nuclear Materials, 582, p.154467_1 - 154467_12, 2023/08

 Times Cited Count:3 Percentile:95.99(Materials Science, Multidisciplinary)

JAEA Reports

Differential pressure rise event for filters of HTTR primary helium gas circulators, 1; Investigation of differential pressure rise event

Nemoto, Takahiro; Arakawa, Ryoki; Kawakami, Satoru; Nagasumi, Satoru; Yokoyama, Keisuke; Watanabe, Masashi; Onishi, Takashi; Kawamoto, Taiki; Furusawa, Takayuki; Inoi, Hiroyuki; et al.

JAEA-Technology 2023-005, 33 Pages, 2023/05

JAEA-Technology-2023-005.pdf:5.25MB

During shut down of the HTTR (High Temperature engineering Test Reactor) RS-14 cycle, an increasing trend of filter differential pressure for the helium gas circulator was observed. In order to investigate this phenomenon, the blower of the primary helium purification system was disassembled and inspected. As a result, it is clear that the silicon oil mist entered into the primary coolant due to the deterioration of the charcoal filter performance. The replacement and further investigation of the filter are planning to prevent the reoccurrence of the same phenomenon in the future.

Journal Articles

Numerical evaluation on fluctuation absorption characteristics based on nuclear heat supply fluctuation test using HTTR

Takada, Shoji; Honda, Yuki*; Inaba, Yoshitomo; Sekita, Kenji; Nemoto, Takahiro; Tochio, Daisuke; Ishii, Toshiaki; Sato, Hiroyuki; Nakagawa, Shigeaki; Sawa, Kazuhiro*

Proceedings of 9th International Topical Meeting on High Temperature Reactor Technology (HTR 2018) (USB Flash Drive), 7 Pages, 2018/10

Nuclear heat utilization systems connected to HTGRs will be designed on the basis of non-nuclear grade standards for easy entry of chemical plant companies, requiring reactor operations to continue even if abnormal events occur in the systems. The inventory control is considered as one of candidate methods to control reactor power for load following operation for siting close to demand area, in which the primary gas pressure is varied while keeping the reactor inlet and outlet coolant temperatures constant. Numerical investigation was carried out based on the results of nuclear heat supply fluctuation tests using HTTR by non-nuclear heating operation to focus on the temperature transient of the reactor core bottom structure by imposing stepwise fluctuation on the reactor inlet temperature under different primary gas pressures below 120C. As a result, it was emerged that the fluctuation absorption characteristics are not deteriorated by lowering pressure. It was also emerged that the reactor outlet temperature did not reach the scram level by increasing the reactor inlet temperature 10 C stepwise at 80% of the rated power as same with the full power case.

Journal Articles

Loss of core cooling test with one cooling line inactive in Vessel Cooling System of High-Temperature Engineering Test Reactor

Fujiwara, Yusuke; Nemoto, Takahiro; Tochio, Daisuke; Shinohara, Masanori; Ono, Masato; Takada, Shoji

Journal of Nuclear Engineering and Radiation Science, 3(4), p.041013_1 - 041013_8, 2017/10

In HTTR, the test was carried out at the reactor thermal power of 9 MW under the condition that one cooling line of VCS was stopped to simulate the partial loss of cooling function from the surface of RPV in addition to the loss of forced cooling flow in the core simulation. The test results showed that temperature change of the core internal structures and the biological shielding concrete was slow during the test. Temperature of RPV decreased several degrees during the test. The temperature decrease of biological shielding made of concrete was within 1$$^{circ}$$C. The numerical result simulating the detail configuration of the cooling tubes of VCS showed that the temperature rise of cooling tubes of VCS was about 15$$^{circ}$$C, which is sufficiently small, which did not significantly affect the temperature of biological shielding concrete. As the results, it was confirmed that the cooling ability of VCS can be kept in case that one cooling line of VCS is lost.

Journal Articles

Nuclear heat supply fluctuation tests by non-nuclear heating with HTTR

Inaba, Yoshitomo; Sekita, Kenji; Nemoto, Takahiro; Honda, Yuki; Tochio, Daisuke; Sato, Hiroyuki; Nakagawa, Shigeaki; Takada, Shoji; Sawa, Kazuhiro

Journal of Nuclear Engineering and Radiation Science, 2(4), p.041001_1 - 041001_7, 2016/10

The nuclear heat utilization systems connected to High Temperature Gas-cooled Reactors (HTGRs) will be designed on the basis of non-nuclear grade standards in terms of the easier entry of chemical plant companies and the construction economics of the systems. Therefore, it is necessary that the reactor operations can be continued even if abnormal events occur in the systems. The Japan Atomic Energy Agency has developed a calculation code to evaluate the absorption of thermal load fluctuations by the reactors when the reactor operations are continued after such events, and has improved the code based on the High Temperature engineering Test Reactor (HTTR) operating data. However, there were insufficient data on the transient temperature behavior of the metallic core side components and the graphite core support structures corresponding to the fluctuation of the reactor inlet coolant temperature for further improvement of the code. Thus, nuclear heat supply fluctuation tests with the HTTR were carried out in non-nuclear heating operation to focus on thermal effect. In the tests, the coolant helium gas temperature was heated up to 120$$^{circ}$$C by the compression heat of the gas circulators in the HTTR, and a sufficiently high fluctuation of 17$$^{circ}$$C by devising a new test procedure was imposed on the reactor inlet coolant under the ideal condition without the effect of the nuclear power. Then, the temperature responses of the metallic core side components and the graphite core support structures were investigated. The test results adequately showed as predicted that the temperature responses of the metallic components are faster than those of the graphite structures, and the mechanism of the thermal load fluctuation absorption by the metallic components was clarified.

Journal Articles

Loss of core cooling test without one cooling line in Vessel Cooling System (VCS) of High Temperature engineering Test Reactor (HTTR)

Fujiwara, Yusuke; Nemoto, Takahiro; Tochio, Daisuke; Shinohara, Masanori; Ono, Masato; Hamamoto, Shimpei; Iigaki, Kazuhiko; Takada, Shoji

Proceedings of 24th International Conference on Nuclear Engineering (ICONE-24) (DVD-ROM), 7 Pages, 2016/06

In HTTR, the test was carried out at the reactor thermal power of 9 MW under the condition that one cooling line of VCS was stopped to simulate the partial loss of cooling function from the surface of RPV in addition to the loss of forced cooling flow in the core simulation. The test results showed that temperature change of the core internal structures and the biological shielding concrete was slow during the test. Temperature of RPV decreased several degrees during the test. The temperature decrease of biological shielding made of concrete was within 1$$^{circ}$$C. The numerical result simulating the detail configuration of the cooling tubes of VCS showed that the temperature rise of cooling tubes of VCS was about 15 degree C, which is sufficiently small, which did not significantly affect the temperature of biological shielding concrete. As the results, it was confirmed that the cooling ability of VCS can be kept in case that one cooling line of VCS is lost.

JAEA Reports

Development of active control technology for impurities in coolant helium using High Temperature Engineering Test Reactor (HTTR)

Hamamoto, Shimpei; Nemoto, Takahiro; Sekita, Kenji; Saito, Kenji

JAEA-Technology 2015-048, 62 Pages, 2016/03

JAEA-Technology-2015-048.pdf:2.58MB

The decarburization may take place depending on the chemical impurity composition in helium gas used as the primary coolant in High-Temperature Gas-cooled Reactors, and will significantly reduce the strength of the alloy. The ability to remove impurities by a helium purification system was designed according to the predicted generation rate of impurities so as to make the coolant become the carburizing atmosphere. It has been confirmed that the coolant becomes the carburizing atmosphere during the operation period of the High Temperature engineering Test Reactor (HTTR). However, it is necessary to consider changes of generation rates of impurities since lifetime of commercial reactor is longer than the life of the HTTR. To avoid the influence of the change of generation rate, the control of removal efficiency of impurity in the helium purification system was considered in this study. To reform the decarburizing into the carburizing atmosphere, it is effective to increase the H$$_{2}$$ and CO concentration in the coolant helium. By controlling the efficiency of the Cooper Oxide Trap (CuOT), it is possible to increase the H$$_{2}$$ and CO concentrations. Therefore, an experiment was carried out by injecting the gas mixture of H$$_{2}$$ and CO into the existing purification system of HTTR to investigate the dependencies of temperature and impurity concentration on the removal efficiency of CuOT. The experimental results are described as the following, (1) By adjusting the temperature of helium at the CuOT within a range from 110$$^{circ}$$C to 50$$^{circ}$$C, it is possible to reduce the removal efficiency of H$$_{2}$$ sufficiently. (2) Temperature change of helium gas in the CuOT is sufficiently reduced by the cooler located at the downstream of the CuOT, which does not affect the primary cooling system of HTTR. As the results, the applicability of removal efficiency control of CuOT was verified to improve the decarburizing atmosphere for the actual HTGR system.

Journal Articles

2016 Professional Engineer (PE) test preparation course "Nuclear and Radiation Technical Disciplines"

Takahashi, Naoki; Yoshinaka, Kazuyuki; Harada, Akio; Yamanaka, Atsushi; Ueno, Takashi; Kurihara, Ryoichi; Suzuki, Soju; Takamatsu, Misao; Maeda, Shigetaka; Iseki, Atsushi; et al.

Nihon Genshiryoku Gakkai Homu Peji (Internet), 64 Pages, 2016/00

no abstracts in English

Journal Articles

Improvement of the vacuum pressure of the bunch shape monitor at J-PARC linac

Miyao, Tomoaki*; Miura, Akihiko; Kawane, Yusuke; Tamura, Jun; Nemoto, Yasuo; Ao, Hiroyuki*; Hayashi, Naoki; Oguri, Hidetomo; Ouchi, Nobuo; Mayama, Minoru*; et al.

Proceedings of 12th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.1338 - 1341, 2015/09

no abstracts in English

Journal Articles

Nuclear heat supply fluctuation test by non-nuclear heating using HTTR

Takada, Shoji; Sekita, Kenji; Nemoto, Takahiro; Honda, Yuki; Tochio, Daisuke; Inaba, Yoshitomo; Sato, Hiroyuki; Nakagawa, Shigeaki; Sawa, Kazuhiro

Proceedings of 23rd International Conference on Nuclear Engineering (ICONE-23) (DVD-ROM), 7 Pages, 2015/05

To investigate the safety design criteria of heat utilization system for the HTGRs, it is necessary to evaluate the effect of fluctuation of thermal load on the reactor. The nuclear heat supply fluctuation test by non-nuclear heating was carried out to simulate the nuclear heat supply test which is carried out in the nuclear powered operation. The test data is used to verify the numerical code to calculate the temperature of core bottom structure to carry out the safety evaluation of abnormal events in the heat utilization system. In the test, the helium gas temperature was heated up to 120$$^{circ}$$C. A sufficiently high temperature disturbance was imposed on the reactor inlet temperature. It was found that the response of temperatures of metallic components such as side shielding blocks was faster than those of graphite blocks in the core bottom structure, which was significantly affected by the heat capacities of components, the level of imposed disturbance and heat transfer performance.

JAEA Reports

Improvement in oil seal performance of gas compressor in HTTR, 2

Nemoto, Takahiro; Kaneshiro, Noriyuki*; Sekita, Kenji; Furusawa, Takayuki; Kuroha, Misao; Kawakami, Satoru; Kondo, Masaaki

JAEA-Technology 2015-006, 36 Pages, 2015/03

JAEA-Technology-2015-006.pdf:16.77MB

The High-Temperature engineering Test Reactor (HTTR) has been developed for establishing and upgrading the technical basis of HTGR.HTTR facilities have their structures, systems and a lot of components including reciprocating gas compressors, commonly used to extract and/or discharge reactor coolant helium gas contained in primary/secondary coolant systems. From the fact of the operational experiences of these compressors, seal-oil leakage has been frequently observed, although rod-seal mechanisms with complicated structures are equipped and improved for preventing coolant helium gas. So, we tried to change the rod-seal materials which might be a primary reason of frequent seal-oil leakage, that resulted in decreasing a mass and frequently of seal-oil leakage. It is confirmed that it is important to select adequate materials of rod seal for sliding speed of the piston of the compressor to prevent seal-oil leakage. Additionally, the procedure to estimate seal-oil leakage for each compressor is discussed. This report describes the results of investigation for improvement on seal-oil leak tightness of the compressors in HTTR facilities.

Journal Articles

High-power test of annular-ring coupled structures for the J-PARC linac energy upgrade

Tamura, Jun; Ao, Hiroyuki; Nemoto, Yasuo; Asano, Hiroyuki*; Suzuki, Takahiro*

Journal of the Korean Physical Society, 66(3), p.399 - 404, 2015/02

 Times Cited Count:0 Percentile:0(Physics, Multidisciplinary)

ACSs are going to increase the beam energy of the J-PARC linac from 181 to 400 MeV. The 2011 Tohoku earthquake damaged the J-PARC facilities and the cavity conditioning was interrupted for two years. After the restoration of the facility, the two ACS cavities (M01 and M11) were conditioned. They achieved to 15-20% above the designed accelerating field of 4.2 MV/m. Since M01 was conditioned six years ago, the conditioning time required for M01 was drastically reduced from that for the first time. During the high-power operation for M11, which is an unique cavity equipped with a capacitive iris in a waveguide, no significant increase of the temperature and the discharge rate around the capacitive iris was observed. The vacuum pressure was sufficiently low (4$$times$$10$$^{-6}$$ Pa) even from the view point of beam loss due to residual gas scattering. The more stable operation can be expected through one-month conditioning before beam commissioning.

Journal Articles

Present status of J-PARC linac

Oguri, Hidetomo; Hasegawa, Kazuo; Ito, Takashi; Chishiro, Etsuji; Hirano, Koichiro; Morishita, Takatoshi; Shinozaki, Shinichi; Ao, Hiroyuki; Okoshi, Kiyonori; Kondo, Yasuhiro; et al.

Proceedings of 11th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.389 - 393, 2014/10

no abstracts in English

Journal Articles

Resuming of ACS high-power test for J-PARC Linac Energy Upgrade

Tamura, Jun; Ao, Hiroyuki; Nemoto, Yasuo; Asano, Hiroyuki*; Suzuki, Takahiro*

Proceedings of 10th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.437 - 439, 2014/06

no abstracts in English

Journal Articles

Investigation of chemical characteristics of primary helium gas coolant of HTTR (High Temperature engineering Test Reactor)

Hamamoto, Shimpei; Shimazaki, Yosuke; Furusawa, Takayuki; Nemoto, Takahiro; Inoi, Hiroyuki; Takada, Shoji

Nuclear Engineering and Design, 271, p.487 - 491, 2014/05

 Times Cited Count:5 Percentile:36.96(Nuclear Science & Technology)

The technical basis of helium gas purification control for HTGRs was established by verifying the design of the PHPS of HTTR by showing that the measured concentrations of impurities of primary helium coolant were restricted below the criteria to protect the graphite oxidation, and that the carburization atmosphere was maintained to keep intact of metallic high temperature components, in the 30-day continuous operation and the 50-day long term high temperature operation. The improved analytical model predicted the composition of the impurities such as H$$_{2}$$, CO, H$$_{2}$$O and CO$$_{2}$$, which is determined by the temperature dependency of release of impurities during the rated power operation adequately. In contrast, it was revealed that the measured concentration of H$$_{2}$$O remarkably decreased while the concentration of CO increased in the primary helium coolant in the long term high temperature operation.

Journal Articles

Chemical characteristics of helium coolant of HTTR (High Temperature engineering Test Reactor)

Hamamoto, Shimpei; Shimazaki, Yosuke; Furusawa, Takayuki; Nemoto, Takahiro; Inoi, Hiroyuki; Takada, Shoji

Proceedings of 6th International Topical Meeting on High Temperature Reactor Technology (HTR 2012) (USB Flash Drive), 8 Pages, 2012/10

Journal Articles

Dust generation and transport behavior in the primary circuit of HTTR

Hamamoto, Shimpei; Shimazaki, Yosuke; Furusawa, Takayuki; Nemoto, Takahiro; Inoi, Hiroyuki

Proceedings of 20th International Conference on Nuclear Engineering and the ASME 2012 Power Conference (ICONE-20 & POWER 2012) (DVD-ROM), 7 Pages, 2012/07

Journal Articles

Complementary characterization of radioactivity produced by repetitive laser-driven proton beam using shot-to-shot proton spectral measurement and direct activation measurement

Ogura, Koichi; Shizuma, Toshiyuki; Hayakawa, Takehito; Yogo, Akifumi; Nishiuchi, Mamiko; Orimo, Satoshi; Sagisaka, Akito; Pirozhkov, A. S.; Mori, Michiaki; Kiriyama, Hiromitsu; et al.

Japanese Journal of Applied Physics, 51(4), p.048003_1 - 048003_2, 2012/04

 Times Cited Count:2 Percentile:8.93(Physics, Applied)

A proton beam driven by a repetitive high-intensity-laser is utilized to induce a $$^{7}$$Li(p,n)$$^{7}$$Be nuclear reaction. The total activity of $$^{7}$$Be are evaluated by two different methods. The activity obtained measuring the decay $$gamma$$-rays after 1912 shots at 1 Hz is 1.7$$pm$$0.2 Bq. This is in good agreement with 1.6$$pm$$0.3 Bq evaluated from the proton energy distribution measured using a time-of-flight detector and the nuclear reaction cross-sections. We conclude that the production of activity can be monitored in real time using the time-of-flight-detector placed inside a diverging proton beam coupled with a high-speed signal processing system.

JAEA Reports

Evaluating techniques and phenomena of Stress Corrosion Cracking (SCC) in Light Water Reactors (LWRs); SCC evaluating techniques for predicting core internal and pipe aging of LWRs, technical data collection (Contract research)

Yamamoto, Masahiro; Kato, Chiaki; Sato, Tomonori; Nakano, Junichi; Ugachi, Hirokazu; Tsukada, Takashi; Kaji, Yoshiyuki; Tsujikawa, Shigeo*; Hattori, Shigeo*; Yoshii, Tsuguyasu*; et al.

JAEA-Review 2012-007, 404 Pages, 2012/03

JAEA-Review-2012-007.pdf:36.72MB

There are many LWRs which have been operated for more than 20 years in Japan and it is expected that technique corresponding to aging plants are necessary established for safety operation in LWRs. A lot of troubles related to SCC are reported and many investigations are concerned with SCC mechanism and technical evaluation. In this paper, those research data were collected as possible widely and reviewed systematically. Current circumstances concerned with SCC in LWRs were reviewed specifically as follows: SCC incidents, SCC evaluation methods for crack initiation and propagation, the investigations concerned with SCC mechanism and monitoring technique for corrosive environment. Influences with reactor types (BWR, PWR), materials (stainless steels, Ni alloys) and SCC evaluating methods (laboratories and actual plants) were summarized as graphs and tables easy to understand in common/difference points concerned with SCC. From these arranged results, future themes were considered and remarked SCC phenomenon was summarized in actual plants. As for SCC evaluations under the accelerate conditions in the laboratory test, it was suggested that a computational prediction and modeling including statistical technique and microscopic analysis in crack initiation were important. Furthermore it was suggested that monitoring techniques predicting SCC initiation and grasping plant circumstance in operation and feasibility in actual plants were important.

192 (Records 1-20 displayed on this page)