Hayashi, Koji; Inagaki, Yoshiyuki; Kato, Michio; Fujisaki, Katsuo*; Aita, Hideki; Takeda, Tetsuaki; Nishihara, Tetsuo; Inaba, Yoshitomo; Ohashi, Hirofumi; Katanishi, Shoji; et al.
JAERI-Tech 2005-032, 46 Pages, 2005/06
This is annual report on the experimental operation of the mock-up test facility with a full-scale reaction tube for the HTTR hydrogen production system in 2001 fiscal year. The first experimental operation was performed during two weeks from March 1, 2002 to March 13, 2002 to test on the thermal hydraulic performance of the steam reformer and also to train the operators. The thermal hydraulic performance test of the steam reformer was performed to evaluate the heat transfer characteristics between helium gas and process gas in the steam reformer. This report is summarized with an overview of the test, the results and its operation records.
Shimizu, Akira; Ohashi, Hirofumi; Kato, Michio; Hayashi, Koji; Aita, Hideki; Nishihara, Tetsuo; Inaba, Yoshitomo; Takada, Shoji; Morisaki, Norihiro; Sakaki, Akihiro*; et al.
JAERI-Tech 2005-031, 174 Pages, 2005/06
Connection of hydrogen production system by steam reforming of methane to the High Temperature Engineering Test Reactor (HTTR) of the Japan Atomic Energy Research Institute (JAERI) has been surveyed until now. Mock-up test facility of this steam reforming system with full-scale reaction tube was constructed in FY 2001, and a lot of operational test data on heat exchanges were obtained in these tests.In this report specifications, structures and heat transfer formulae of steam reformer, steam superheater, steam generator, condenser, helium gas cooler, feed gas heater and feed gas superheater were described. Evaluation codes were newly made to evaluate heat transfer characteristics from measured test data. Overall heat-transfer coefficient obtained from the experimental data were compared and evaluated with the prospective value calculated with heat transfer formulae. As a result, heat transfer performance and thermal efficiency of these heat exchangers were confirmed to be appropriate.
Sakaki, Akihiro*; Kato, Michio; Hayashi, Koji; Fujisaki, Katsuo*; Aita, Hideki; Ohashi, Hirofumi; Takada, Shoji; Shimizu, Akira; Morisaki, Norihiro; Maeda, Yukimasa; et al.
JAERI-Tech 2005-023, 72 Pages, 2005/04
In order to establish the system integration technology to connect a hydrogen production system to a high temperature gas cooled reactor, the mock-up test facility with a full-scale reaction tube for the steam reforming HTTR hydrogen production system was constructed in fiscal year 2001 and its functional test operation was performed in the year. Seven experimental test operations were performed from fiscal year 2001 to 2004. On a period of each test operation, there happened some troubles. For each trouble, the cause was investigated and the countermeasures and the improvement works were performed to succeed the experiments. The tests were successfully achieved according to plan.This report describes the improvement works on the test facility performed from fiscal year 2001 to 2004.
Nishihara, Tetsuo; Sakaki, Akihiro*; Inagaki, Yoshiyuki; Takami, Kazuo*
Nihon Genshiryoku Gakkai Wabun Rombunshi, 3(4), p.381 - 387, 2004/12
JAERI has been carried out research and development on the HTTR hydrogen production system. One of the key components in this system is a high temperature isolation valve (HTIV) installed on the hot helium gas piping penetrating the reactor containment vessel. Angle valve with inner thermal insulator was selected for HTIV and conceptual design was performed. The structural integrity of HTIV was clarified by the stress analyses. Allowable helium leak rate of HTIV was discussed. Helium leak tests using small-scaled valve seat models were performed to decide the seat surface shape and valve closing force. The test results show that the leak rate of wedge shape seat increased in proportion to the number of simulated temperature and stress cycles loaded on the seat models before helium leak test, however that of flat seat did not depend on the number of cycles. So flat seat is adopted for HTIV. It was found that the seat closing force of 30 MPa is reasonable to meet the allowable helium leak rate.
Inagaki, Yoshiyuki; Hayashi, Koji; Kato, Michio; Fujisaki, Katsuo; Aita, Hideki; Takeda, Tetsuaki; Nishihara, Tetsuo; Inaba, Yoshitomo; Ohashi, Hirofumi; Katanishi, Shoji; et al.
JAERI-Tech 2003-034, 129 Pages, 2003/05
no abstracts in English
Shimizu, Akira; Kato, Michio; Hayashi, Koji; Fujisaki, Katsuo; Aita, Hideki; Takeda, Tetsuaki; Nishihara, Tetsuo; Katanishi, Shoji; Takada, Shoji; Inaba, Yoshitomo; et al.
JAERI-Tech 2003-033, 105 Pages, 2003/03
no abstracts in English
Ohashi, Hirofumi; Sakaki, Akihiro; Inagaki, Yoshiyuki
JAERI-Research 2000-058, 64 Pages, 2001/01
no abstracts in English