Refine your search:     
Report No.
 - 
Search Results: Records 1-1 displayed on this page of 1
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

JAEA Reports

Study on Advanced Structural Design for Commercialized Fast Breeder Reactors

Morishita, Masaki; Kitamura, Seiji; Takahashi, Kenji; Inoue, Kazuhiko; Kida, Masanori; Moro, Satoshi*; Kato, Asao*; Fushimi, Minoru*

JNC TY9400 2004-028, 921 Pages, 2004/11

Japan Nuclear Cycle Development Institute (JNC) and Japan Atomic Power Company (JAPC) launched joint research programs on structural design and three-dimensional seismic isolation technologies, as part of the supporting R&D activities for the feasibility studies on commercialized fast breeder reactor cycle systems. A research project by JAPC under the auspices of the Ministry of Economy, Trade, and Industry (METI) with technical support by JNC is included in this joint study. This report contains the results of the research on the structural design technology. The research scope was identified as (1) Study on Developing Program, (2) Study on 3-dimentional Entire Building Base Isolation System, and (3) Study on Vertical Isolation System for Main Equipment, and the results of this year's studies are summarized as follows. (1) Study on Developing Program -Performance Requirements for 3-dimensional Isolation Devices "The behavior of a three-dimensional isolated reactor building" and "amenity under the strong wind load" were studied in order to set up performance requirements for the three-dimensional isolation system. Consequently, it was proved for the former subject that the structure of horizontal base-dimensional isolated building was applicable to 3-D isolated building and for the latter that amenity of the operator in the 3-D isolated reactor building is not affected under the strong wind. -Development Targets and Schedules for Three-dimensional Isolation Deviece In order to select the development candidate of the three dimensional isolation devices, "evaluation items and criteria" and "technical guideline on seismic three-dimensional isolation system" were studied. For the former subject, detailed requirements to the component in the reactor building were studied based on the 2002 fiscal year result and embodied.(2) Study on 3-dimentional Entire Building Base Isolation System -The 3 system concepts nominated on 2001, "Hydraulic system", "Fiber reinforced air sp

1 (Records 1-1 displayed on this page)
  • 1