Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 95

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

A Terrestrial SER Estimation Methodology Based on Simulation Coupled With One-Time Neutron Irradiation Testing

Abe, Shinichiro; Hashimoto, Masanori*; Liao, W.*; Kato, Takashi*; Asai, Hiroaki*; Shimbo, Kenichi*; Matsuyama, Hideya*; Sato, Tatsuhiko; Kobayashi, Kazutoshi*; Watanabe, Yukinobu*

IEEE Transactions on Nuclear Science, 70(8, Part 1), p.1652 - 1657, 2023/08

 Times Cited Count:0 Percentile:0.01(Engineering, Electrical & Electronic)

Single event upsets (SEUs) caused by neutrons is a reliability problem for microelectronic devices in the terrestrial environment. Acceleration tests using white neutron beam provide realistic soft error rates (SERs), but only a few facilities can provide white neutron beam in the world. If single-source irradiation applicable to diverse neutron source can be utilized for the evaluation of the SER in the terrestrial environment, it contributes to solve the shortage of beam time. In this study, we investigated the feasibility of the SER estimation in the terrestrial environment by any one of these measured data with the SEU cross sections obtained by PHITS simulation. It was found that the SERs estimated by our proposed method are within a factor of 2.7 of that estimated by the Weibull function. We also investigated the effect of simplification which reduce the computational cost in simulation to the SER estimation.

Journal Articles

PSTEP: Project for solar-terrestrial environment prediction

Kusano, Kanya*; Ichimoto, Kiyoshi*; Ishii, Mamoru*; Miyoshi, Yoshizumi*; Yoden, Shigeo*; Akiyoshi, Hideharu*; Asai, Ayumi*; Ebihara, Yusuke*; Fujiwara, Hitoshi*; Goto, Tadanori*; et al.

Earth, Planets and Space (Internet), 73(1), p.159_1 - 159_29, 2021/12

 Times Cited Count:6 Percentile:49.29(Geosciences, Multidisciplinary)

The PSTEP is a nationwide research collaboration in Japan and was conducted from April 2015 to March 2020, supported by a Grant-in-Aid for Scientific Research on Innovative Areas from the Ministry of Education, Culture, Sports, Science and Technology of Japan. It has made a significant progress in space weather research and operational forecasts, publishing over 500 refereed journal papers and organizing four international symposiums, various workshops and seminars, and summer school for graduate students at Rikubetsu in 2017. This paper is a summary report of the PSTEP and describes the major research achievements it produced.

Journal Articles

Dimensional reduction by geometrical frustration in a cubic antiferromagnet composed of tetrahedral clusters

Okuma, Ryutaro*; Kofu, Maiko; Asai, Shinichiro*; Avdeev, M.*; Koda, Akihiro*; Okabe, Hirotaka*; Hiraishi, Masatoshi*; Takeshita, Soshi*; Kojima, Kenji*; Kadono, Ryosuke*; et al.

Nature Communications (Internet), 12, p.4382_1 - 4382_7, 2021/07

 Times Cited Count:7 Percentile:60.19(Multidisciplinary Sciences)

Journal Articles

Measurement of double-differential thick-target neutron yields of the C($$d,n$$) reaction at 12, 20, and 30 MeV

Patwary, M. K. A*; Kin, Tadahiro*; Aoki, Katsumi*; Yoshinami, Kosuke*; Yamaguchi, Masaya*; Watanabe, Yukinobu*; Tsukada, Kazuaki; Sato, Nozomi*; Asai, Masato; Sato, Tetsuya; et al.

Journal of Nuclear Science and Technology, 58(2), p.252 - 258, 2021/02

 Times Cited Count:0 Percentile:0.01(Nuclear Science & Technology)

While designing deuteron accelerator neutron sources for radioisotopes production, nuclear data for light elements such as Li, Be, and C have been systematically measured in the deuteron energy range from a few MeV to around 50 MeV. Currently, the experimental data available on double-differential thick-target neutron yields (DDTTNYs) is insufficient, especially for deuteron energies between 18 and 33 MeV. In this study, we measured the DDTTNYs of ($$d,n$$) reactions on $$^{rm nat}$$C target for incident deuteron energies of 12, 20, and 30 MeV using the multiple-foils activation method to improve nuclear data insufficiency. We applied the GRAVEL code for the unfolding process to derive the DDTTNYs. The results were compared with the calculation by DEURACS. The present data were also used to confirm the systematics of the differential neutron yields at 0$$^{circ}$$ and total neutron yield per incident deuteron in the wide range of deuteron energy.

Journal Articles

Electron-tracking Compton camera imaging of technetium-95m

Hatsukawa, Yuichi*; Hayakawa, Takehito*; Tsukada, Kazuaki; Hashimoto, Kazuyuki*; Sato, Tetsuya; Asai, Masato; Toyoshima, Atsushi; Tanimori, Toru*; Sonoda, Shinya*; Kabuki, Shigeto*; et al.

PLOS ONE (Internet), 13(12), p.e0208909_1 - e0208909_12, 2018/12

AA2018-0639.pdf:2.39MB

 Times Cited Count:3 Percentile:29.78(Multidisciplinary Sciences)

Imaging of $$^{95m}$$Tc radioisotope was conducted using an electron tracking-Compton camera (ETCC). $$^{95m}$$Tc emits 204, 582, and 835 keV $$gamma$$ rays, and was produced in the $$^{95}$$Mo(p,n)$$^{95m}$$Tc reaction with a $$^{95}$$Mo-enriched target. The recycling of the $$^{95}$$Mo-enriched molybdenum trioxide was investigated, and the recycled yield of $$^{95}$$Mo was achieved to be 70% - 90%. The images were obtained with each of the three $$gamma$$ rays. Results showed that the spatial resolution increases with increasing $$gamma$$-ray energy, and suggested that the ETCC with high-energy $$gamma$$-ray emitters such as $$^{95m}$$Tc is useful for the medical imaging of deep tissue and organs in the human body.

Journal Articles

Rapid separation of zirconium using microvolume anion-exchange cartridge for $$^{93}$$Zr determination with isotope dilution ICP-MS

Asai, Shiho; Hanzawa, Yukiko; Konda, Miki; Suzuki, Daisuke; Magara, Masaaki; Kimura, Takaumi; Ishihara, Ryo*; Saito, Kyoichi*; Yamada, Shinsuke*; Hirota, Hideyuki*

Talanta, 185, p.98 - 105, 2018/08

 Times Cited Count:8 Percentile:31.52(Chemistry, Analytical)

Estimating the risks associated with radiation from long-lived fission products (LLFP) in radioactive waste is essential to ensure the long-term safety of potential disposal sites. In this study, the amount of $$^{93}$$Zr, a LLFP, was determined by ICP-MS after separating Zr from a spent nuclear fuel solution using a microvolume anion-exchange cartridge (TEDA cartridge). The TEDA cartridge achieved highly selective separation of Zr regardless of its small bed volume of 0.08 cm$$^{3}$$. The time taken to complete the Zr separation was 1.2 min with a flow rate of 1.5 mL/min, which was 10 times faster than that for a conventional anion-exchange resin column. Almost all the other elements were removed, leading to accurate measurement of $$^{93}$$Zr. The result connects experimental value to theoretical prediction provided by ORIGEN2, which requires verification. With the measured value, we demonstrated that the theoretical value is reliable enough to estimate radiation risks.

Journal Articles

Determination of fusion barrier distributions from quasielastic scattering cross sections towards superheavy nuclei synthesis

Tanaka, Taiki*; Narikiyo, Yoshihiro*; Morita, Kosuke*; Fujita, Kunihiro*; Kaji, Daiya*; Morimoto, Koji*; Yamaki, Sayaka*; Wakabayashi, Yasuo*; Tanaka, Kengo*; Takeyama, Mirei*; et al.

Journal of the Physical Society of Japan, 87(1), p.014201_1 - 014201_9, 2018/01

 Times Cited Count:18 Percentile:74.14(Physics, Multidisciplinary)

Excitation functions of quasielastic scattering cross sections for the $$^{48}$$Ca + $$^{208}$$Pb, $$^{50}$$Ti + $$^{208}$$Pb, and $$^{48}$$Ca + $$^{248}$$Cm reactions were successfully measured by using the gas-filled recoil-ion separator GARIS. Fusion barrier distributions were extracted from these data, and compared with the coupled-channels calculations. It was found that the peak energies of the barrier distributions for the $$^{48}$$Ca + $$^{208}$$Pb and $$^{50}$$Ti + $$^{208}$$Pb systems coincide with those of the 2n evaporation channel cross sections for the systems, while that of the $$^{48}$$Ca + $$^{248}$$Cm is located slightly below the 4n evaporation ones. This results provide us helpful information to predict the optimum beam energy to synthesize superheavy nuclei.

Journal Articles

Study of the reaction $$^{48}$$Ca + $$^{248}$$Cm $$rightarrow$$ $$^{296}$$Lv$$^{ast}$$ at RIKEN-GARIS

Kaji, Daiya*; Morita, Kosuke*; Morimoto, Koji*; Haba, Hiromitsu*; Asai, Masato; Fujita, Kunihiro*; Gan, Z.*; Geissel, H.*; Hasebe, Hiroo*; Hofmann, S.*; et al.

Journal of the Physical Society of Japan, 86(3), p.034201_1 - 034201_7, 2017/03

 Times Cited Count:27 Percentile:82.58(Physics, Multidisciplinary)

The fusion reaction of $$^{48}$$Ca + $$^{248}$$Cm $$rightarrow$$ $$^{296}$$Lv$$^{ast}$$ was studied using the gas-filled recoil-ion separator GARIS at RIKEN. A total of seven $$alpha$$ and spontaneous-fission decay chains were observed, which would originate from the reaction products of the element 116, $$^{292}$$Lv and $$^{293}$$Lv. Decay properties observed in the chains are in good agreement with the previously published ones. However, one of the chains showed a discrepancy, indicating the new spontaneous-fission branch in $$^{285}$$Cn or the production of the new isotope $$^{294}$$Lv.

Journal Articles

Complex chemistry with complex compounds

Eichler, R.*; Asai, Masato; Brand, H.*; Chiera, N. M.*; Di Nitto, A.*; Dressler, R.*; D$"u$llmann, Ch. E.*; Even, J.*; Fangli, F.*; Goetz, M.*; et al.

EPJ Web of Conferences, 131, p.07005_1 - 07005_7, 2016/12

 Times Cited Count:3 Percentile:72.98(Chemistry, Inorganic & Nuclear)

In recent years gas-phase chemical studies assisted by physical pre-separation allowed for the productions and investigations of fragile single molecular species of superheavy elements. The latest highlight is the formation of very volatile hexacarbonyl compound of element 106, Sg(CO)$$_{6}$$. Following this success, second-generation experiments were performed to measure the first bond dissociation energy between the central metal atom and the surrounding ligand. The method using a tubular decomposition reactor was developed and successfully applied to short-lived Mo(CO)$$_{6}$$, W(CO)$$_{6}$$, and Sg(CO)$$_{6}$$.

Journal Articles

Preparation of microvolume anion-exchange cartridge for inductively coupled plasma mass spectrometry-based determination of $$^{237}$$Np content in spent nuclear fuel

Asai, Shiho; Hanzawa, Yukiko; Konda, Miki; Suzuki, Daisuke; Magara, Masaaki; Kimura, Takaumi; Ishihara, Ryo*; Saito, Kyoichi*; Yamada, Shinsuke*; Hirota, Hideyuki*

Analytical Chemistry, 88(6), p.3149 - 3155, 2016/03

 Times Cited Count:8 Percentile:29.59(Chemistry, Analytical)

Neptunium-237 ($$^{237}$$Np) is one of the major long-lived radionuclides found in spent nuclear fuel. To evaluate the long-term safety of a HLW repository, the $$^{237}$$Np content in spent nuclear fuel must be determined. In this study, micro-volume anion-exchange porous polymer disk-packed cartridges were prepared for Am-Np separation, which is required prior to the measurement of $$^{237}$$ Np with ICP-MS. Disks with a volume of 0.08 cm$$^{3}$$ were cut out from porous sheets having triethylenediamine (TEDA)-containing polymer chains densely attached on the pore surface. The resulting TEDA-introduced disk cartridge was applied to a spent nuclear fuel sample. The chemical yield of Np was 90.4%, which is sufficiently high for ICP-MS measurement of $$^{237}$$Np. Compared with the conventional separation technique using commercially available anion-exchange resin columns, the time required to adsorb, wash and elute Np using the TEDA-introduced disk cartridge was reduced by 75%.

Journal Articles

Decomposition studies of group 6 hexacarbonyl complexes, 1; Production and decomposition of Mo(CO)$$_6$$ and W(CO)$$_6$$

Usoltsev, I.*; Eichler, R.*; Wang, Y.*; Even, J.*; Yakushev, A.*; Haba, Hiromitsu*; Asai, Masato; Brand, H.*; Di Nitto, A.*; D$"u$llmann, Ch. E.*; et al.

Radiochimica Acta, 104(3), p.141 - 151, 2016/03

 Times Cited Count:31 Percentile:94.91(Chemistry, Inorganic & Nuclear)

Conditions of the production and decomposition of hexacarbonyl complexes of short-lived Mo and W isotopes were investigated to study thermal stability of the heaviest group 6 hexacarbonyl complex Sg(CO)$$_6$$. A tubular flow reactor was tested to decompose the hexacarbonyl complexes and to extract the first bond dissociation energies. A silver was found to be the most appropriate reaction surface to study the decomposition of the group 6 hexacarbonyl. It was found that the surface temperature at which the decomposition occurred was correlated to the first bond dissociation energy of Mo(CO)$$_6$$ and W(CO)$$_6$$, indicating that the first bond dissociation energy of Sg(CO)$$_6$$ could be determined with this technique.

Journal Articles

First $$alpha$$-$$gamma$$ spectroscopy using Si-Ge detector array installed at focal plane of GARIS

Kaji, Daiya*; Morimoto, Koji*; Wakabayashi, Yasuo*; Takeyama, Mirei*; Asai, Masato

JPS Conference Proceedings (Internet), 6, p.030106_1 - 030106_4, 2015/06

A Si-Ge detector array was newly installed at the focal plane of the gas-filled recoil ion separator GARIS to perform $$alpha$$-$$gamma$$ (X-rays) spectroscopy for superheavy nuclei. The performance of the array was tested using the $$^{207}$$Pb($$^{48}$$Ca,2n)$$^{253}$$No and $$^{208}$$Pb($$^{48}$$Ca,xn)$$^{256-x}$$No [x=1,2,3] reactions. $$gamma$$ rays originating from the $$alpha$$ decay of $$^{253}$$No and $$^{255}$$No were clearly observed in prompt coincidence with the $$alpha$$ particles.

Journal Articles

Performance of new gas-filled recoil ion separator GARIS-II for asymmetric fusion reaction

Kaji, Daiya*; Morimoto, Koji*; Wakabayashi, Yasuo*; Takeyama, Mirei*; Yamaki, Sayaka*; Tanaka, Kengo*; Haba, Hiromitsu*; Huang, M.*; Murakami, Masashi*; Kanaya, Jumpei*; et al.

JPS Conference Proceedings (Internet), 6, p.030107_1 - 030107_4, 2015/06

Performance of the new gas-filled recoil ion separator GARIS-II was investigated using asymmetric $$^{22}$$Ne-induced fusion reactions. The use of He-H$$_{2}$$ mixture gas for the gas-filled magnet significantly reduced background scattered particles detected at the focal-plane Si detector, and increased a transmission of the asymmetric reaction products. A target-identification system was newly installed for efficient measurements of excitation functions without changing beam energy nor target.

Journal Articles

Production of $$^{88}$$Nb and $$^{170}$$Ta for chemical studies of element 105, Db, using the GARIS gas-jet system

Huang, M.*; Haba, Hiromitsu*; Murakami, Masashi*; Asai, Masato; Kaji, Daiya*; Kanaya, Jumpei*; Kasamatsu, Yoshitaka*; Kikunaga, Hidetoshi*; Kikutani, Yuki*; Komori, Yukiko*; et al.

Journal of Radioanalytical and Nuclear Chemistry, 304(2), p.845 - 849, 2015/05

 Times Cited Count:3 Percentile:25.64(Chemistry, Analytical)

A technique to utilize radioisotopes of Nb and Ta was developed for chemical studies of element 105, Db, by coupling a gas-jet transport system to the RIKEN gas-filled recoil ion separator (GARIS). The short-lived $$^{88}$$Nb and $$^{170}$$Ta were produced with nuclear reactions using a $$^{19}$$F beam whose energy was the same as that to produce $$^{262}$$Db. Then, they were separated with GARIS and extracted to a chemistry laboratory with the gas-jet transport system. By changing only magnetic field of GARIS and inserting an energy degrader and a shutter for recoil ions, we could deliver the $$^{88}$$Nb and $$^{170}$$Ta to a chemistry device for $$^{262}$$Db without changing other experimental conditions.

Journal Articles

In situ synthesis of volatile carbonyl complexes with short-lived nuclides

Even, J.*; Ackermann, D.*; Asai, Masato; Block, M.*; Brand, H.*; Di Nitto, A.*; D$"u$llmann, Ch. E.*; Eichler, R.*; Fan, F.*; Haba, Hiromitsu*; et al.

Journal of Radioanalytical and Nuclear Chemistry, 303(3), p.2457 - 2466, 2015/03

 Times Cited Count:15 Percentile:77.35(Chemistry, Analytical)

Rapid In situ synthesis of metal carbonyl complexes has been demonstrated using short-lived isotopes produced in nuclear fission and fusion reactions. The short-lived isotopes with high recoil energy directly react with carbon-monoxides and form carbonyl complexes. Only highly volatile complexes were fast transported in a gas stream to counting and chemistry devices. Short-lived Mo, Tc, Ru, Rh, W, Re, Os, and Ir were found to form volatile carbonyl complexes, while no volataile complex of Hf and Ta were detected. This technique has been applied to a chemical investigation of the superheavy element Sg (atomic number 106), and will be applicable to various fields of nuclear science with short-lived transition metal isotopes.

Journal Articles

Production of $$^{rm 95m}$$Tc for Compton camera imaging

Hatsukawa, Yuichi; Hashimoto, Kazuyuki; Tsukada, Kazuaki; Sato, Tetsuya; Asai, Masato; Toyoshima, Atsushi; Nagai, Yasuki; Tanimori, Toru*; Sonoda, Shinya*; Kabuki, Shigeto*; et al.

Journal of Radioanalytical and Nuclear Chemistry, 303(2), p.1283 - 1285, 2015/02

 Times Cited Count:2 Percentile:17.52(Chemistry, Analytical)

Technetium-99m ($$^{rm 99m}$$Tc) is used in radioactive medical diagonostic tests, for example as a radioactive tracer that medical equipment can detect in the human body. It is well suited to the role because it emits readily detectable 141 keV $$gamma$$ rays, and its half-life is 6.01 hours (meaning that about 94% of it decays to technetium-99 in 24 hours). There are at least 31 commonly used radiopharmaceuticals based on technetium-99m for imaging and functional studies of the brain, myocardium, thyroid, lungs, liver, gallbladder, kidneys, skeleton, blood, and tumors. Recent years, with the develop-ment of the Compton camera which can realize high position resolution, technetium isotopes emitting high energy $$gamma$$-rays are required. In this study, technetium-95m which emits some $$gamma$$ rays around 800 keV was produced by the $$^{95}$$Mo(p,n)$$^{rm 95m}$$Tc reaction.

Journal Articles

Synthesis and detection of a Seaborgium carbonyl complex

Even, J.*; Yakushev, A.*; D$"u$llmann, Ch. E.*; Haba, Hiromitsu*; Asai, Masato; Sato, Tetsuya; Brand, H.*; Di Nitto, A.*; Eichler, R.*; Fan, F. L.*; et al.

Science, 345(6203), p.1491 - 1493, 2014/09

 Times Cited Count:64 Percentile:83.15(Multidisciplinary Sciences)

A new superheavy element complex, a seaborgium carbonyl, has been successfully synthesized, and its adsorption property has been studied using a cryo-thermochromatography and $$alpha$$-detection apparatus COMPACT. Nuclear reaction products of short-lived $$^{265}$$Sg preseparated with a gas-filled recoil ion separator GARIS at RIKEN were directly injected into a gas cell filled with He/CO mixture gas, and chemical reaction products of volatile carbonyl complexes were trasported to COMPACT. The Sg carbonyl complex detected with COMPACT was found to be very volatile with adsorption enthalpy of $$-$$50 kJ/mol, from which we have concluded that this complex should be a Sg hexacarbonyl Sg(CO)$$_{6}$$. This is the first synthesis of organometallic compounds of transactinide elements for which only simple inorganic comounds have been synthesized so far.

Journal Articles

Weak ferromagnetic ordering disordered by Rh$$^{3+}$$ ions for LaCo$$_{0.8}$$Rh$$_{0.2}$$O$$_{3}$$

Asai, Shinichiro*; Okazaki, Ryuji*; Terasaki, Ichiro*; Yasui, Yukio*; Igawa, Naoki; Kakurai, Kazuhisa

JPS Conference Proceedings (Internet), 3, p.014034_1 - 014034_6, 2014/06

We have carried out the neutron scattering measurements for a single crystal of LaCo$$_{0.8}$$Rh$$_{0.2}$$O$$_{3}$$ in order to investigate the ferromagnetic ordering induced by Rh$$^{3+}$$ substitution for Co$$^{3+}$$ of LaCoO$$_{3}$$. The ordered moment is evaluated to be 0.4$$pm$$0.2$$mu$$$$_{B}$$, which is consistent with the saturation magnetization of LaCo$$_{0.8}$$Rh$$_{0.2}$$O$$_{3}$$. It indicates that the ferromagnetic ordering of LaCo$$_{0.8}$$Rh$$_{0.2}$$O$$_{3}$$ originates from the short-range ferromagnetic ordering disordered by Rh$$^{3+}$$ ions.

Journal Articles

Theory of macroscopic quantum tunneling with Josephson-Leggett collective excitations in multiband superconducting Josephson junctions

Asai, Hidehiro*; Ota, Yukihiro; Kawabata, Shiro*; Machida, Masahiko; Nori, F.*

Physical Review B, 89(22), p.224507_1 - 224507_7, 2014/06

 Times Cited Count:9 Percentile:38.66(Materials Science, Multidisciplinary)

Collective excitations reveal fundamental properties and potential applications of superconducting states. We study macroscopic quantum tunneling (MQT) in a Josephson junction composed of multiband superconductors, focusing on a phase mode induced by interband fluctuations: the Josephson-Leggett (JL) collective excitation mode. We derive a formula for the MQT escape rate for low-temperature switching events, carefully treating this collective mode. We clarify that the JL mode has two major effects on the MQT: (1) the zero-point fluctuations enhance the escape rate, and (2) the quantum dissipation induced by the couplings to the gauge-invariant phase difference suppresses the quantum tunneling. We show that the enhancement exceeds the suppression for a wide range of junction parameters. This enhancement originates from the single-mode interaction between the tunneling variable and the interband fluctuations.

Journal Articles

Utilization status at TIARA facility

Haruyama, Yasuyuki; Takizawa, Haruki; Hosono, Masakazu; Mizuhashi, Kiyoshi*; Nakamura, Yoshiteru*; Kaneya, Satoshi*; Asai, Takahiro*; Kawabata, Michiko*; Imai, Koji*

JAEA-Review 2013-059, JAEA Takasaki Annual Report 2012, P. 177, 2014/03

Cyclotron use in FY 2012, was 2243.5 hours beam time. Among them, the use time of Bio technology and Medical application relationship most, I occupy the time spent for the Quarter of the total. Use offer to the outside utilization was 17%. Use the number of days in Electrostatic Accelerators was 490 days. Among them, Basic technology is accounted for using the percentage of 46%, but the use of irradiation Reactor materials and irradiation of Material for space even more, I accounted for 18 percent utilization rate, respectively, of 15%. Use offer to the outside utilization was 8%.

95 (Records 1-20 displayed on this page)