Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Yamauchi, Michinori*; Nishitani, Takeo; Ochiai, Kentaro; Morimoto, Yuichi*; Hori, Junichi; Ebisawa, Katsuyuki*; Kasai, Satoshi; Walker, C.*
Review of Scientific Instruments, 74(3), p.1730 - 1734, 2003/03
Times Cited Count:22 Percentile:70.86(Instruments & Instrumentation)no abstracts in English
Nishitani, Takeo; Ebisawa, Katsuyuki*; Kasai, Satoshi; Walker, C.*
Review of Scientific Instruments, 74(3), p.1735 - 1738, 2003/03
Times Cited Count:14 Percentile:58.58(Instruments & Instrumentation)no abstracts in English
Nishitani, Takeo; Iguchi, Tetsuo*; Ebisawa, Katsuyuki*; Yamauchi, Michinori*; Walker, C.*; Kasai, Satoshi
JAERI-Tech 2002-062, 39 Pages, 2002/07
no abstracts in English
Nishitani, Takeo; Ebisawa, Katsuyuki*; Walker, C.*; Kasai, Satoshi
JAERI-Tech 2002-033, 40 Pages, 2002/03
no abstracts in English
Yamauchi, Michinori*; Nishitani, Takeo; Ochiai, Kentaro; Morimoto, Yuichi*; Hori, Junichi; Ebisawa, Katsuyuki*; Kasai, Satoshi
JAERI-Tech 2002-032, 41 Pages, 2002/03
A micro-fission chamber and a dummy chamber without uranium were fabricated and the performance was tested. They are designed to be installed inside the vacuum vessel of compact ITER (ITER-FEAT) for neutron monitoring. Vacuum leak rate of the chamber, resistances between central conductor and outer sheath, and mechanical strength up to 50G acceleration were confirmed to meet design criteria. Gamma-ray sensitivity was measured with Co gamma-ray irradiation facility at JAERI Takasaki. The output signals for gamma-rays in Campbelling mode were estimated to be less than 0.1% those by neutrons at the location behind the blanket module in ITER-FEAT. Detector response for 14 MeV neutrons was investigated with the FNS facility. Excellent linearity between count rates and neutron fluxes was confirmed. According to the test for the change of surrounding materials, the sensitivity was enhanced by slow-downed neutrons, which agreed with the calculation result by MCNP-4C code. As a result, it was concluded that the developed micro-fission chamber is applicable for ITER-FEAT.
Nishitani, Takeo; Ebisawa, Katsuyuki*; Walker, C.*; Kasai, Satoshi
JAERI-Tech 2001-066, 57 Pages, 2001/10
no abstracts in English
Uno, Yoshitomo; Kaneko, Junichi; Nishitani, Takeo; Maekawa, Fujio; Tanaka, Teruya; Shibata, S.*; Ikeda, Yujiro; Khripunov, V.*; Walker, C. I.*; Ebisawa, Katsuyuki*; et al.
Fusion Engineering and Design, 56-57, p.895 - 898, 2001/10
Times Cited Count:8 Percentile:52.3(Nuclear Science & Technology)no abstracts in English
Ebisawa, Katsuyuki*; Costley, A.*; Donn, A. J. H.*; Janeschitz, G.*; Kasai, Satoshi; Malaquias, A.*; Vayakis, G.*; Walker, C. I.*; Yamamoto, Shin; Zavariaev, V.*
Review of Scientific Instruments, 72(1), p.545 - 550, 2001/01
Times Cited Count:18 Percentile:67.36(Instruments & Instrumentation)no abstracts in English
Ozeki, Takahisa; Iio, Shunji*; Yoshino, Ryuji; Shimada, Michiya; Fujisawa, Noboru; Ebisawa, Katsuyuki*; Ioki, Kimihiro*; Nakamura, Yukiharu; Tokuda, Shinji; Hayashi, Nobuhiko
Purazuma, Kaku Yugo Gakkai-Shi, 76(7), p.694 - 696, 2000/07
no abstracts in English
Kawano, Yasunori; Kondoh, Takashi; Ishikawa, Masao; Hatae, Takaki; Hayashi, Toshimitsu; Ono, Takehiro; Ogawa, Hiroaki; Sugie, Tatsuo; Iwamae, Atsushi; Kusama, Yoshinori; et al.
no journal, ,
Progress in ITER diagnostics development in Japan is presented. (1) Micro Fission Chamber: A bending test of the mineral insulated cable has been carried out since its smallest bending radius would be 12 cm in the vacuum vessel. It has been confirmed that no damage has been observed even at the bending radius is small as 10 cm. (2) Thomson Scattering (Edge): It has been confirmed that the prototype YAG laser amplifier satisfies the target performance of ITER requirement. (3) Poloidal Polarimeter: Study of retro-reflectors in the first wall modules and the divertor cassette has been progressed. (4) Impurity Influx Monitor (Divertor): Mechanical designs of mirror box and optical shutter in the divertor cassette have been designed. (5) Upper Port Plug: For the generic design of the upper port plug (UPP), mesh modeling of UPP has been performed for the E-M analysis. Application of HIP (Hot Isostatic Press) method for manufacturing of UPP has been proposed.
Kawano, Yasunori; Ishikawa, Masao; Kusama, Yoshinori; Hayashi, Toshimitsu; Ono, Takehiro; Ebisawa, Katsuyuki*; Wakabayashi, Kuniaki*; Kiyohara, Motosuke*
no journal, ,
no abstracts in English
Kawano, Yasunori; Kondoh, Takashi; Ishikawa, Masao; Ogawa, Hiroaki; Iwamae, Atsushi; Sugie, Tatsuo; Sato, Kazuyoshi; Hatae, Takaki; Yatsuka, Eiichi; Hayashi, Toshimitsu; et al.
no journal, ,
no abstracts in English
Kawano, Yasunori; Ishikawa, Masao; Sato, Kazuyoshi; Kusama, Yoshinori; Hayashi, Toshimitsu; Ono, Takehiro; Ebisawa, Katsuyuki*; Wakabayashi, Kuniaki*; Hiramatsu, Miho*; Kiyohara, Michio*; et al.
no journal, ,
no abstracts in English
Kawano, Yasunori; Ishikawa, Masao; Sato, Kazuyoshi; Imazawa, Ryota; Kusama, Yoshinori; Hayashi, Toshimitsu; Ono, Takehiro; Ebisawa, Katsuyuki*; Wakabayashi, Kuniaki*; Hiramatsu, Miho*; et al.
no journal, ,
Yatsuka, Eiichi; Hatae, Takaki; Ebisawa, Katsuyuki*; Wakabayashi, Kuniaki*; Kusama, Yoshinori
no journal, ,
no abstracts in English
Kawano, Yasunori; Imazawa, Ryota; Ono, Takehiro; Ishikawa, Masao; Hayashi, Toshimitsu; Sato, Kazuyoshi; Kusama, Yoshinori; Ebisawa, Katsuyuki*; Wakabayashi, Kuniaki*; Katsumata, Takahito*
no journal, ,
no abstracts in English
Takeuchi, Masaki; Sugie, Tatsuo; Ogawa, Hiroaki; Kusama, Yoshinori; Ebisawa, Katsuyuki*; Wakabayashi, Kunio*; Nariai, Kyoji*; Tanimoto, Aki*; Kiyohara, Motosuke*
no journal, ,
no abstracts in English