Refine your search:     
Report No.
 - 
Search Results: Records 1-2 displayed on this page of 2
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Study on piping response under multiple excitations; Triple shaking table test of piping having three-supporting anchors

Watakabe, Tomoyoshi; Kaneko, Naoaki*; Aida, Shigekazu*; Otani, Akihito*; Tsukimori, Kazuyuki; Moriizumi, Makoto; Kitamura, Seiji

Dynamics and Design Conference 2013 (D&D 2013) Koen Rombunshu (USB Flash Drive), 8 Pages, 2013/08

The piping in a nuclear power plant is laid across multiple floors of a single building or two buildings, which are supported at many anchors. As the piping is excited by multiple inputs from the supporting anchors during an earthquake, seismic response analysis by multiple excitations is needed to obtain the exact seismic response of the piping. However, few tests involving such multiple excitations have been performed to verify the validity of multiple excitation analysis. To perform rational seismic design and evaluation, it is important to investigate the seismic response by multiple excitations and verify the validity of the analysis method by multiple excitation test. This paper reports on the result of the shaking test using triple uni-axial shaking tables and a 3-dimensional piping model.

Journal Articles

Study on piping response under multiple excitation, 1; Triple shaking table test of piping having three-supporting points

Watakabe, Tomoyoshi; Kaneko, Naoaki*; Aida, Shigekazu*; Otani, Akihito*; Moriizumi, Makoto*; Tsukimori, Kazuyuki; Kitamura, Seiji

Proceedings of 2013 ASME Pressure Vessels and Piping Conference (PVP 2013) (DVD-ROM), 8 Pages, 2013/07

The piping in a nuclear power plant is laid across multiple floors of a single building or two buildings, which are supported at many points. As the piping is excited by multiple inputs from the supporting points during an earthquake, seismic response analysis by multiple excitations is needed to obtain the exact seismic response of the piping. However, few experiments involving such multiple excitations have been performed to verify the validity of multiple excitation analysis. To perform rational seismic design and evaluation, it is important to investigate the seismic response by multiple excitations and verify the validity of the analysis method by multiple excitation test. This paper reports on the result of the shaking test using triple uni-axial shaking tables and a 3-dimensional piping model.

2 (Records 1-2 displayed on this page)