Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 26

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Estimation of external dose for wild Japanese macaques captured in Fukushima prefecture; Decomposition of electron spin resonance spectrum

Mitsuyasu, Yusuke*; Oka, Toshitaka; Takahashi, Atsushi*; Kino, Yasushi*; Okutsu, Kenichi*; Sekine, Tsutomu*; Yamashita, Takuma*; Shimizu, Yoshinaka*; Chiba, Mirei*; Suzuki, Toshihiko*; et al.

Radiation Protection Dosimetry, 199(14), p.1620 - 1625, 2023/09

We have been conducting dose assessments for Japanese macaques captured in Fukushima to reveal radiobiological effects on the low-dose expose animals. To accurately determine the external exposure dose, it is desirable to examine the analysis of the CO$$_{2}^{-}$$ radical intensity. We examined ESR spectra of teeth of 10 macaques captured in Fukushima by two spectrum-decomposition algorithms.

Journal Articles

A Study on accuracy of analysis of the radiation-induced component in the ESR spectra of teeth

Mitsuyasu, Yusuke*; Oka, Toshitaka; Takahashi, Atsushi*; Kino, Yasushi*; Okutsu, Kenichi*; Sekine, Tsutomu*; Yamashita, Takuma*; Shimizu, Yoshinaka*; Chiba, Mirei*; Suzuki, Toshihiko*; et al.

KEK Proceedings 2022-2, p.120 - 125, 2022/11

We investigate the effect of sample's anisotropy and measurement condition to obtain the higher reproducibility for the shape of the ESR spectrum and the intensity of CO$$_{2}^{-}$$ radical.

Journal Articles

Radiation exposure and oxidative stress status of wild Japanese macaques in the ex-evacuation zone of the Fukushima Daiichi Nuclear Power Plant accident

Ishikawa, Ryoya*; Suzuki, Masatoshi*; Kino, Yasushi*; Endo, Satoru*; Nakajima, Hiroo*; Oka, Toshitaka; Takahashi, Atsushi*; Shimizu, Yoshinaka*; Suzuki, Toshihiko*; Shinoda, Hisashi*; et al.

KEK Proceedings 2022-2, p.61 - 66, 2022/11

The balance between oxidative stress and antioxidant activity, which is a defense mechanism against oxidative stress, was investigated in the liver and bladder of wild Japanese macaques captured in Fukushima Prefecture. No significant induction of oxidative stress by exposure to environmental radionuclides after the Fukushima nuclear accident was observed, suggesting that the stress defense mechanism of the organism is activated in some organs.

Journal Articles

Development of dose estimation method using wild animal teeth for low dose exposure

Mitsuyasu, Yusuke*; Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Kino, Yasushi*; Okutsu, Kenichi*; Sekine, Tsutomu*; Yamashita, Takuma*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.

KEK Proceedings 2021-2, p.91 - 96, 2021/12

We examined whether the ESR dose estimation method could be applied to wild Japanese macaque. In this work, we investigated the enamel preparation protocol and the analytical method of the ESR spectra.

Journal Articles

Rapid analysis of $$^{90}$$Sr in cattle bone and tooth samples by inductively coupled plasma mass spectrometry

Koarai, Kazuma; Matsueda, Makoto; Aoki, Jo; Yanagisawa, Kayo*; Terashima, Motoki; Fujiwara, Kenso; Kino, Yasushi*; Oka, Toshitaka; Takahashi, Atsushi*; Suzuki, Toshihiko*; et al.

Journal of Analytical Atomic Spectrometry, 36(8), p.1678 - 1682, 2021/08

 Times Cited Count:3 Percentile:57.04(Chemistry, Analytical)

Rapid analysis of $$^{90}$$Sr in bone and tooth samples of cattle were achieved by an inductively coupled plasma mass spectrometry (ICP-MS) coupled with mass shift and solid phase extraction techniques. Limit of detection (LOD) in the ICP-MS measurement of 0.1 g samples was lower than that of the radioactivity measurement. Analytical time of the ICP-MS method was reduced from 20 days to 11 hours, compared with the radiometric method. Therefore, the ICP-MS method can be rapid and useful procedure of $$^{90}$$Sr in small bone and tooth samples derived from terrestrial animals.

Journal Articles

Morphological reproductive characteristics of testes and fertilization capacity of cryopreserved sperm after the Fukushima accident in raccoon (${it Procyon lotor}$)

Komatsu, Kazuki*; Iwasaki, Tsugumi*; Murata, Kosuke*; Yamashiro, Hideaki*; Goh, V. S. T.*; Nakayama, Ryo*; Fujishima, Yohei*; Ono, Takumi*; Kino, Yasushi*; Shimizu, Yoshinaka*; et al.

Reproduction in Domestic Animals, 56(3), p.484 - 497, 2021/03

 Times Cited Count:9 Percentile:88.06(Agriculture, Dairy & Animal Science)

We have established an archive system of livestock and wild animals from the surrounding ex-evacuation zone. Wildlife within the alert zone have been exposed to low-dose-rate (LDR) radiation for a long and continuous time. In this study, we analysed the morphological characteristics of the testes and in vitro fertilization (IVF) capacity of cryopreserved sperm of raccoons from the ex-evacuation zone of the FDNPP accident. This study revealed that the chronic and LDR radiation exposure associated with the FDNPP accident had no adverse effect on the reproductive characteristics and functions of male raccoons.

Journal Articles

External exposure dose estimation by electron spin resonance technique for wild Japanese macaque captured in Fukushima Prefecture

Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Mitsuyasu, Yusuke*; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; Suzuki, Toshihiko*; Osaka, Ken*; et al.

Radiation Measurements, 134, p.106315_1 - 106315_4, 2020/06

 Times Cited Count:4 Percentile:54.54(Nuclear Science & Technology)

The relationship between the CO$$_{2}$$ radical intensity and the absorbed dose (dose response curve) of tooth enamel of Japanese macaque was observed by electron spin resonance and the detection limit of our system was estimated to be 33.5 mGy, which is comparable to the detection limit for human molar teeth. Using the dose response curve, external exposure dose for seven wild Japanese macaques captured in Fukushima prefecture were examined. The results suggest that the external exposure dose for the wild Japanese macaques were ranged between 45 mGy to 300 mGy.

Journal Articles

An Energy spread minimization system for microbeam generation in the JAERI AVF cyclotron

Fukuda, Mitsuhiro; Kurashima, Satoshi; Miyawaki, Nobumasa; Okumura, Susumu; Kamiya, Tomihiro; Oikawa, Masakazu*; Nakamura, Yoshiteru; Nara, Takayuki; Agematsu, Takashi; Ishibori, Ikuo; et al.

Nuclear Instruments and Methods in Physics Research B, 210, p.33 - 36, 2003/09

 Times Cited Count:4 Percentile:33.72(Instruments & Instrumentation)

A heavy ion microbeam with energy of hundreds MeV is a significantly useful probe for research in biotechnology. A single-ion hitting technique using a 260 MeV $$^{20}$$Ne$$^{7+}$$ microbeam is being developed at the JAERI AVF cyclotron facility for biofunction elucidation. Production of a microbeam with a spot size of one micro-meter in diameter requires reducing the energy spread of the beam to 0.02 % to minimize an effect of chromatic aberrations in focusing lenses. The typical energy spread of the cyclotron beam is around 0.1 % in an ordinary acceleration mode using a sinusoidal voltage waveform. The energy spread can be reduced by superimposing the fifth-harmonic voltage waveform on the fundamental one to generate a flattop waveform for uniform energy gain. We have designed an additional coaxial cavity to generate the fifth-harmonic voltage, coupled to the main resonator of one-fourth wavelength coaxial type. In a power test we successfully observed the fifth-harmonic voltage waveform by picking up an acceleration voltage signal.

Journal Articles

Flat-top acceleration system for the variable-energy multiparticle AVF cyclotron

Fukuda, Mitsuhiro; Kurashima, Satoshi; Okumura, Susumu; Miyawaki, Nobumasa; Agematsu, Takashi; Nakamura, Yoshiteru; Nara, Takayuki; Ishibori, Ikuo; Yoshida, Kenichi; Yokota, Wataru; et al.

Review of Scientific Instruments, 74(4), p.2293 - 2299, 2003/04

 Times Cited Count:14 Percentile:58.7(Instruments & Instrumentation)

A combination of the fundamental- and the fifth-harmonic voltages is ideally suited for flat-top acceleration in a variable-energy multi-particle cyclotron for energy-spread minimization. The flat-topping of the energy gain distribution using the fifth-harmonics has the advantages of minimizing an amplifier power, reducing power dissipation in a resonator and increasing the energy gain per turn. The flat-top acceleration system of the JAERI AVF cyclotron was designed to reduce the energy spread to 0.02 $$%$$, required for microbeam production. Tolerable fluctuations of acceleration voltages and the magnetic excitation were 2.0$$times$$10$$^{-4}$$ for the fundamental voltage, 1.0$$times$$10$$^{-3}$$ for the fifth-harmonic voltage, and 1.9$$times$$10$$^{-5}$$ for the magnetic field. In order to enhance compactness of the flat-topping cavity and to make a substantial saving of the amplifier power, optimum geometric parameters of the flat-topping cavity were determined by a cold model test and a calculation using the MAFIA code.

Journal Articles

Design of the flat-top acceleration system for the JAERI AVF cyclotron

Kurashima, Satoshi; Fukuda, Mitsuhiro; Nakamura, Yoshiteru; Nara, Takayuki; Agematsu, Takashi; Ishibori, Ikuo; Tamura, Hiroyuki; Yokota, Wataru; Okumura, Susumu; Arakawa, Kazuo; et al.

AIP Conference Proceedings 600, p.303 - 305, 2001/00

A flat-top acceleration system for the JAERI AVF cyclotron has been designed. The fifth harmonic of the fundamental frequency is used to obtain uniform energy gain. To determine optimum parameters of the flat-top system, a cold model test was carried out and flat-top waveforms of the voltages were observed successfully in the whole range of the fundamental frequency. An rf power required for generating a flat-top dee voltage of 30 kV was estimated to be about 1 kW. The design of the flat-top cavity is being modified using the MAFIA code.

Journal Articles

A Modified RF system of JAERI AVF cyclotron

*; *; Fukuda, Mitsuhiro; Arakawa, Kazuo; *; *

Proceedings of 13th International Conference on Cyclotrons and Their Applications, p.526 - 529, 1993/00

no abstracts in English

Journal Articles

RF system of JAERI AVF cyclotron

Fukuda, Mitsuhiro; Arakawa, Kazuo; Nakamura, Yoshiteru; Yokota, Wataru; Kamiya, Tomihiro; Nara, Takayuki; Agematsu, Takashi; Okumura, Susumu; Ishibori, Ikuo; Tanaka, Ryuichi; et al.

Proc. of the 8th Symp. on Accelerator Science and Technology, p.138 - 140, 1991/00

no abstracts in English

Oral presentation

External dose estimation of Japanese macaque and Procyon lotor using electron spin resonance spectroscopy

Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Ono, Takumi*; Tamaki, Hiroaki*; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; Suzuki, Toshihiko*; et al.

no journal, , 

Releases of the radioactive materials from the Fukushima Daiichi Nuclear Power Plant accident result in an ionization exposure to people and animals, the precise dosimetry is required. To estimate the external dose due to the accident, we utilize electron spin resonance (ESR) spectroscopy which is a powerful tool for the dosimetry of external dose. The detection limit of this technique was 146 mGy, so that we have to improve the detection limit for the precise dosimetry. In this work, we developed a novel enamel-dentine separation technique and improved the detection limit down to 43 mGy, and estimated the external dose for Japanese macaque and Procyon lotor collected in Fukushima prefecture.

Oral presentation

Incorporation record of radionuclides in teeth and otoliths

Koarai, Kazuma; Matsueda, Makoto; Fujiwara, Kenso; Ono, Takumi*; Kino, Yasushi*; Oka, Toshitaka; Okutsu, Kenichi*; Takahashi, Atsushi*; Suzuki, Toshihiko*; Shimizu, Yoshinaka*; et al.

no journal, , 

We have investigated incorporation of $$^{90}$$Sr and $$^{137}$$Cs in teeth of cattle and otoliths of fish. Specific activity of $$^{90}$$Sr in the dentin tissue was higher than that in the enamel tissue. The result shows change of $$^{90}$$Sr incorporation in cattle even within a tooth. Concentrations of stable Sr and Cs were 94 ppm and 3 ppb. Distributions of stable Sr and Cs were uniform in the otolith of fish. If distribution of $$^{90}$$Sr and $$^{137}$$Cs in the otolith was measured, change of $$^{90}$$Sr and $$^{137}$$Cs incorporation into the fish would be found. These findings suggest that distribution patterns of $$^{90}$$Sr and $$^{137}$$Cs in the environment could be estimated from distribution of the radionuclides in the tooth and otolith.

Oral presentation

Sample preparation procedure for the estimation of external exposure dose of wild animals using elecron spin resonance spectroscopy

Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Mitsuyasu, Yusuke*; Ono, Takumi*; Tamaki, Hiroaki*; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.

no journal, , 

Release of the radioactive materials from Fukushima Daiichi Nuclear Power Plant accident results in a long-term low dose rate ionization exposure to wild animals. The biological effects of the wild animal do not show a clear correlation with the external dose, which is estimated from the external dose rate of the captured point of the animal, a precise external dose estimation using ESR and tooth enamel is required instead of using the external dose rate. In this work, we attempted to estimate the external dose of wild Japanese macaque and Procyon lotor captured in the high dose rate area.

Oral presentation

External exposure dose of Japanese macaque captured in Fukushima prefecture

Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Mitsuyasu, Yusuke*; Kino, Yasushi*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; Suzuki, Toshihiko*; Osaka, Ken*; et al.

no journal, , 

Due to the Fukushima Daiichi Nuclear Power Plant accident, the exposure dose estimation for human is examined by the whole body counter or by the Fukushima Health Management Survey, however, the precise estimated dose cannot obtained by such methods. We applied electron spin resonance (ESR) dosimetry for the external dose estimation using tooth enamel of human/animal. As we reported last year, we improved the detection limit of ESR dosimetry down to 43 mGy. We used this improved ESR dosimetry system and attempted to estimate the external dose of wild Japanese macaque capture in Fukushima prefecture, however, the metal component which may obstruct the ESR measurement was observed, so that we cannot estimate the external dose. In this work, we investigated how to remove such metal components, obtain the clear ESR spectrum, and estimate the external dose.

Oral presentation

Strontium-90 measurement in trace amount of hard tissues for distribution analysis

Koarai, Kazuma; Matsueda, Makoto; Aoki, Jo; Yanagisawa, Kayo*; Fujiwara, Kenso; Terashima, Motoki; Kino, Yasushi*; Oka, Toshitaka; Okutsu, Kenichi*; Yamashita, Takuma*; et al.

no journal, , 

We demonstrated a method of $$^{90}$$Sr measurement in small pieces of hard tissues with radioactivity measurement or ICP-MS measurement. Interference elements of the measurements were removed by chemical separation. We could determine $$^{90}$$Sr in 0.1 g of hard tissues by radioactivity measurement method and ICP-MS method. Limit of detection of the ICP-MS method was lower than that of the radioactivity measurement. The ICP-MS method is adequate method for distribution analysis of $$^{90}$$Sr in the hard tissues.

Oral presentation

Sample preparation procedure for ESR dosimetry using teeth of wild animal

Oka, Toshitaka; Mitsuyasu, Yusuke*; Takahashi, Atsushi*; Koarai, Kazuma; Kino, Yasushi*; Sekine, Tsutomu*; Okutsu, Kenichi*; Yamashita, Takuma*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.

no journal, , 

Releases of the radioactive materials from the Fukushima Daiichi Nuclear Power Plant accident result in a low dose exposure to wild animals. The external dose of wild animals is commonly estimated by the external dose rate of the captured point, but the estimated exposure dose has huge uncertainties because the size of the habitat and/or the movement of the wild animals are not included in the estimation. To estimate the external dose precisely, we utilize electron spin resonance (ESR) dosimetry. In this work, we investigated the sample preparation procedure of wild animals. The ESR spectrum of enamel of racoon captured in Namie-town, Fukushima has a broad ESR signal due to metal components. The linear relationship between the Co$$_{2}$$ intensity and the absorbed dose that we can apply ESR dosimetry for racoon teeth. Using this relationship, the external exposure dose was estimated.

Oral presentation

Dose estimation for animals exposed low dose using their teeth

Mitsuyasu, Yusuke*; Oka, Toshitaka; Takahashi, Atsushi*; Koarai, Kazuma; Kino, Yasushi*; Okutsu, Kenichi*; Sekine, Tsutomu*; Yamashita, Takuma*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.

no journal, , 

The improvement of the ESR dosimetry is required to apply that for the low-dose exposure of wild animals. We will report our progress of the improvement, and compare the external exposure dose estimated by the ESR dosimetry technique and the calculated result based on the external exposure dose rate of the captured point.

Oral presentation

External exposure dose estimation using ESR dosimetry technique

Oka, Toshitaka; Takahashi, Atsushi*; Mitsuyasu, Yusuke*; Koarai, Kazuma; Kino, Yasushi*; Okutsu, Kenichi*; Yamashita, Takuma*; Sekine, Tsutomu*; Shimizu, Yoshinaka*; Chiba, Mirei*; et al.

no journal, , 

Electron spin resonance (ESR) dosimetry technique is a powerful tool that has been used in the study of external exposure dose assessment of human by measuring CO$$_{2}$$ radicals of teeth. In this work, we applied this technique for wild monkey and wild racoon captured in Fukushima prefecture, and estimated the external exposure dose.

26 (Records 1-20 displayed on this page)