Journal Articles

Radiation exposure to the lens of the eye for Japanese nuclear power plant workers

Yokoyama, Sumi*; Tatsuzaki, Hideo*; Tanimura, Yoshihiko; Yoshitomi, Hiroshi; Hirao, Shigekazu*; Aoki, Katsunori; Tachiki, Shuichi*; Ezaki, Iwao*; Hoshi, Katsuya; Tsujimura, Norio

Journal of Radiological Protection, 42(3), p.031504_1 - 031504_17, 2022/09

 Times Cited Count:1 Percentile:33.72(Environmental Sciences)

In Japan, the radiation-dose limit for the lens of the eye was revised in April 2021. Consequently, for workers, the numerical values of the equivalent dose to the lens of the eye are equal to those of the effective dose. Radiation workers, radiation safety officers and licensees must comply with regulations related to radiation protection and optimize protection. The new guidelines on dose monitoring of the lens of the eye developed by the Japan Health Physics Society recommend for the dose to be estimated near the eye for accurate estimation, when the dose to the lens approaches or exceeds the management criteria. However, there is limited information regarding the non-uniform exposure of nuclear power plant workers. In this study, the dose equivalents of high-dose-rate workplaces and the personal doses of 88 workers were estimated at four Japanese commercial nuclear power plant sites (RWR: 3 units and BWR: 3 units) and the dose to the lens of the eye and the exposure situations of the workers were analyzed.

Journal Articles

The Japan Health Physics Society Guideline on Dose Monitoring for the Lens of the Eye

Yokoyama, Sumi*; Tsujimura, Norio; Hashimoto, Makoto; Yoshitomi, Hiroshi; Kato, Masahiro*; Kurosawa, Tadahiro*; Tatsuzaki, Hideo*; Sekiguchi, Hiroshi*; Koguchi, Yasuhiro*; Ono, Koji*; et al.

Journal of Radiation Protection and Research, 47(1), p.1 - 7, 2022/03

Background: In Japan, new regulations that revise the dose limit for the lens of the eye (the lens), operational quantities, and measurement positions for the lens dose were enforced in April 2021. Based on the international safety standards, national guidelines, the results of the Radiation Safety Research Promotion Fund of the Nuclear Regulatory Authority, and other studies, the Working Group of Radiation Protection Standardization Committee, the Japan Health Physics Society (JHPS) developed a guideline for radiation dose monitoring for the lens. Materials and Methods: The Working Group of the JHPS discussed the criteria of non-uniform exposure and the management criteria set to not exceed the dose limit for the lens. Results and Discussion: In July 2020, the JHPS guideline was published. The guideline consists of three parts: main text, explanations, and 26 questions. In the questions, the corresponding answers were prepared, and specific examples were provided to enable similar cases to be addressed. Conclusion: With the development of guideline on radiation dose monitoring of the lens, radiation managers and workers will be able to smoothly comply with revised regulations and optimise radiation protection.

Journal Articles

Development of guidelines on radiation protection for the lens of the eye in Japan

Yokoyama, Sumi*; Iwai, Satoshi*; Tsujimura, Norio; Hashimoto, Makoto; Yoshitomi, Hiroshi; Kato, Masahiro*; Kurosawa, Tadahiro*; Tatsuzaki, Hideo*; Sekiguchi, Hiroshi*; Koguchi, Yasuhiro*; et al.

Proceedings of 15th International Congress of the International Radiation Protection Association (IRPA-15) (Internet), 8 Pages, 2022/00

Journal Articles

Measurements of the doses of eye lens for the workers of Fukushima Daiichi Nuclear Power Plant

Yokoyama, Sumi*; Ezaki, Iwao*; Tatsuzaki, Hideo*; Tachiki, Shuichi*; Hirao, Shigekazu*; Aoki, Katsunori; Tanimura, Yoshihiko; Hoshi, Katsuya; Yoshitomi, Hiroshi; Tsujimura, Norio

Radiation Measurements, 138, p.106399_1 - 106399_5, 2020/11

 Times Cited Count:2 Percentile:24.76(Nuclear Science & Technology)

Journal Articles

Current situations and discussions in Japan in relation to the new occupational equivalent dose limit for the lens of the eye

Yokoyama, Sumi*; Hamada, Nobuyuki*; Hayashida, Toshiyuki*; Tsujimura, Norio; Tatsuzaki, Hideo*; Kurosawa, Tadahiro*; Nabatame, Kuniaki*; Oguchi, Hiroyuki*; Ono, Kazuko*; Kawaura, Chiyo*; et al.

Journal of Radiological Protection, 37(3), p.659 - 683, 2017/09

 Times Cited Count:14 Percentile:82.46(Environmental Sciences)

Since the International Commission on Radiological Protection recommended reducing the occupational equivalent dose limit for the lens of the eye in 2011, there have been extensive discussions in various countries. This paper reviews the current situations in radiation protection of the ocular lens and the discussions on the potential impact of the new lens dose limit in Japan. Topics include historical changes to the lens dose limit, the current situations in occupational lens exposures (e.g., in medical workers, nuclear workers, and Fukushima nuclear power plant workers) and measurements, and the current status of biological studies and epidemiological studies on radiation cataracts. Our focus is on the situations in Japan, but we believe such information sharing will be useful in many other countries.

Journal Articles

Addendum report of the JHPS expert committee on radiation protection of the lens of the eye, 2; When and how should the dosimetry of beta $$H_{rm p}$$(3) be made?

Akahane, Keiichi*; Iimoto, Takeshi*; Ichiji, Takeshi*; Iwai, Satoshi*; Oguchi, Hiroyuki*; Ono, Kazuko*; Kawaura, Chiyo*; Kurosawa, Tadahiro*; Tatsuzaki, Hideo*; Tsujimura, Norio; et al.

Hoken Butsuri, 50(4), p.257 - 261, 2015/12

In a mixed field of photon and beta radiations, the same dose assigned to skin is normally assigned to the dose to the lens of the eye as a conservative estimate of H$$_{p}$$(3). In exceptional cases that a very high beta dose might be imparted of the same order with the dose limit, however, the conservatively biased dose must be too limiting, and thereby an accurate estimate of beta $$H_{rm p}$$(3) is desirable. This article presents a practical proposal of when and how the dosimetry of beta $$H_{rm p}$$(3) should be made.

Journal Articles

Interim report of the JHPS expert committee on radiation protection of the lens of the eye, 2; The Dosimetry method for the lens of the eye of workers in Japan

Akahane, Keiichi*; Iimoto, Takeshi*; Ichiji, Takeshi*; Iwai, Satoshi*; Oguchi, Hiroyuki*; Ono, Kazuko*; Kawaura, Chiyo*; Tatsuzaki, Hideo*; Tsujimura, Norio; Hamada, Nobuyuki*; et al.

Hoken Butsuri, 49(3), p.153 - 156, 2014/09

A brief review is given of the history and methodology of external dosimetry for the lens of the eye. Under the 1989 revision to domestic radiological protection regulations, the concept on the effective dose equivalent and the dose limit to the lens of the eye (150 mSv/y) both introduced in ICRP 1977 recommendations has changed nationwide the external monitoring methodology in non-uniform exposure situations to the trunk of a radiological worker. In such situations, often created by the presence of a protective apron, the worker is required to use at least two personal dosemeters, one worn on the trunk under the apron and the other, typically, at the collar over the apron. The latter dosemeter serves the dual purpose of providing the dose profile across the trunk for improved effective dose equivalent assessment and of estimating the dose to lens of the eye. The greater or appropriate value between $$H_{rm p}$$(10) and $$H_{rm p}$$(0.07), given by the dosemeter, is generally used as a surrogate of $$H_{rm p}$$(3).

Oral presentation

Eye lens dosimetry for workers at Fukushima Daiichi Nuclear Power Station, 1; Outline of the research and results of dose measurement for the workers

Yokoyama, Sumi*; Ezaki, Iwao*; Aoki, Katsunori; Tatsuzaki, Hideo*; Hirao, Shigekazu*; Tachiki, Shuichi*; Yoshitomi, Hiroshi; Hoshi, Katsuya; Tanimura, Yoshihiko; Oguchi, Hiroyuki*; et al.

no journal, , 

no abstracts in English

Oral presentation

Eye lens dosimetry for workers at Fukushima Daiichi Nuclear Power Station, 2; Summary of personal dose measurement and dosimeter comparison

Ezaki, Iwao*; Aoki, Katsunori; Tatsuzaki, Hideo*; Tachiki, Shuichi*; Hirao, Shigekazu*; Yoshitomi, Hiroshi; Hoshi, Katsuya; Tanimura, Yoshihiko; Oguchi, Hiroyuki*; Tsujimura, Norio; et al.

no journal, , 

no abstracts in English

9 (Records 1-9 displayed on this page)