Prevention of false alarms from automatic fire alarm system in the Tokai Reprocessing Plant

Ishii, Takahiro; Shimizu, Kazuyuki; Sakai, Katsumi; Inami, Shinichi

Dai-7-Kai Saishori, Risaikuru Bukai Semina Tekisuto, p.172 - 173, 2011/01

The automatic fire alarm system installed in the Tokai Reprocessing Plant consists of more than 5,000 detectors in about 40 facilities for the moment. In this system, 57 non-fire cases have occurred for about 10 years from January 2001 to December 2010. and about half of these cases was due to the condensation of water vapor generated on the sensor. Therefore, the prevention of condensation is necessary to reduce such false alarms, and the measure for prevention of condensation has been taken by installing a mount for the detector basement. This mount facilitates that the detector does not contact directly to the surface of ceiling where is likely to change an environment due to changeable temperature and humidity. As a result, false alarms caused by condensation have not been found on the detectors with the mounts. This paper reports the details of the improved fire alarm system, and cause/measures for false alarms.

Journal Articles

Prevention of false alarms from automatic fire alarm system in the Tokai Reprocessing Plant

Ishii, Takahiro; Shimizu, Kazuyuki; Sakai, Katsumi; Inami, Shinichi

Nihon Hozen Gakkai Dai-6-Kai Gakujutsu Koenkai Yoshishu, p.289 - 293, 2009/08

The automatic fire alarm system installed in the Tokai Reprocessing Plant consists of more than 5000 detectors in about 40 facilities for the moment. In this system, 51 non-fire cases have occurred for 8 years; 2001 Jan. to 2009 May, and about half of these cases was due to the condensation of water vapor generated on the sensor. Therefore, the prevention of condensation is necessary to reduce such false alarms, and the measure for prevention of condensation has been taken by installing a mount for the detector basement. This mount facilitates that the detector does not contact directly to the surface of ceiling where is likely to change an environment due to changeable temperature and humidity. As a result, false alarms caused by condensation have not been found on the detectors with the mounts. This paper reports the details of the improved fire alarm system, and cause/measures for false alarms.

JAEA Reports

None

Koizumi, Masumichi; *; *; Furuya, Hirotaka

PNC TN841 73-26, 30 Pages, 1973/09

PNC-TN841-73-26.pdf:4.39MB

no abstracts in English

JAEA Reports

None

Koizumi, Masumichi; *; *; Kaneko, Hiromitsu; Sasao, Nobuyuki*; Komatsu, Junji*

PNC TN841 72-09, 24 Pages, 1972/06

PNC-TN841-72-09.pdf:0.88MB

no abstracts in English

Oral presentation

Development of Tokai Reprocessing Plant Maintenance Support System (TORMASS) in the Tokai Reprocessing Plant

Sakai, Katsumi; Tomita, Tsuneo; Shimizu, Kazuyuki

no journal, , 

The maintenance work of many equipments such as mechanical, electrical and instrumentations installed in Tokai Reprocessing Plant has been performed more then 10,000 times per year and about 90% of maintenances were preventive work. For the maintenance management, optimization of maintenance information is required. Therefore, the aim of construction of suitable maintenance management system, Tokai Reprocessing Plant Maintenance Support System(TORMASS) was developed from 1985 to 1992. About 24,000 equipments of specifications and about 261,000 maintenance detail were registered in this system. TORMASS has been used for the repair, inspection and replacement of equipment.