Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 166

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Neutron transmission CB-KID imager using samples placed at room temperature

Ishida, Takekazu*; Vu, TheDang*; Shishido, Hiroaki*; Aizawa, Kazuya; Oku, Takayuki; Oikawa, Kenichi; Harada, Masahide; Kojima, Kenji M*; Miyajima, Shigeyuki*; Koyama, Tomio*; et al.

Journal of Low Temperature Physics, 214(3-4), p.152 - 157, 2024/02

 Times Cited Count:0 Percentile:0.02(Physics, Applied)

Journal Articles

Orientation mapping of YbSn$$_{3}$$ single crystals based on Bragg-dip analysis using a delay-line superconducting sensor

Shishido, Hiroaki*; Vu, TheDang*; Aizawa, Kazuya; Kojima, Kenji M*; Koyama, Tomio*; Oikawa, Kenichi; Harada, Masahide; Oku, Takayuki; Soyama, Kazuhiko; Miyajima, Shigeyuki*; et al.

Journal of Applied Crystallography, 56(4), p.1108 - 1113, 2023/08

 Times Cited Count:0 Percentile:0.02(Chemistry, Multidisciplinary)

Journal Articles

Structure analysis of a buried interface between organic and porous inorganic layers using spin-contrast-variation neutron reflectivity

Kumada, Takayuki; Miura, Daisuke*; Akutsu, Kazuhiro*; Oishi, Kazuki*; Morikawa, Toshiaki*; Kawamura, Yukihiko*; Suzuki, Junichi*; Oku, Takayuki; Torikai, Naoya*; Niizeki, Tomotake*

Journal of Applied Crystallography, 55(5), p.1147 - 1153, 2022/10

AA2021-0903.pdf:1.06MB

 Times Cited Count:1 Percentile:29.53(Chemistry, Multidisciplinary)

Spin-contrast-variation neutron reflectivity obtains multiple reflectivity curves from a single sample and a single beam source. We used the strong point of the technique to reveal that, although methylated-perhydropolysilazane-derived silica layer has a higher porosity near the interface with acrylic urethane resin, the resin did not permeate the pore network.

Journal Articles

High spatial resolution neutron transmission imaging using a superconducting two-dimensional detector

Shishido, Hiroaki*; Nishimura, Kazuma*; Vu, TheDang*; Aizawa, Kazuya; Kojima, Kenji M*; Koyama, Tomio*; Oikawa, Kenichi; Harada, Masahide; Oku, Takayuki; Soyama, Kazuhiko; et al.

IEEE Transactions on Applied Superconductivity, 31(9), p.2400505_1 - 2400505_5, 2021/12

 Times Cited Count:0 Percentile:0(Engineering, Electrical & Electronic)

In this study, we employed a superconducting detector, current-biased kinetic-inductance detector (CB-KID) for neutron imaging using a pulsed neutron source. We employed the delay-line method, and high spatial resolution imaging with only four reading channels was achieved. We also performed wavelength-resolved neutron imaging by the time-of-flight method. We obtained the neutron transmission images of a Gd-Al alloy sample, inside which single crystals of GdAl$$_{3}$$ were grown, using the delay-line CB-KID. Single crystals were well imaged, in both shapes and distributions, throughout the Al-Gd alloy. We identified Gd nuclei via neutron transmissions that exhibited characteristic suppression above the neutron wavelength of 0.03 nm. In addition, the $$_{155}$$Gd resonance dip, a dip structure of the transmission caused by the nuclear reaction between an isotope and neutrons, was observed even when the number of events was summed over a limited area of 15 $$mu$$m $$times$$ 12 $$mu$$m. Gd selective imaging was performed using the resonance dip of $$_{155}$$Gd, and it showed clear Gd distribution even with a limited neutron wavelength range of 1 pm.

Journal Articles

Practical tests of neutron transmission imaging with a superconducting kinetic-inductance sensor

Vu, TheDang; Shishido, Hiroaki*; Aizawa, Kazuya; Kojima, Kenji M*; Koyama, Tomio*; Oikawa, Kenichi; Harada, Masahide; Oku, Takayuki; Soyama, Kazuhiko; Miyajima, Shigeyuki*; et al.

Nuclear Instruments and Methods in Physics Research A, 1006, p.165411_1 - 165411_8, 2021/08

 Times Cited Count:1 Percentile:18.91(Instruments & Instrumentation)

Journal Articles

Polarization analysis for small-angle neutron scattering with a $$^{3}$$He spin filter at a pulsed neutron source

Okudaira, Takuya; Ueda, Yuki; Hiroi, Kosuke; Motokawa, Ryuhei; Inamura, Yasuhiro; Takata, Shinichi; Oku, Takayuki; Suzuki, Junichi*; Takahashi, Shingo*; Endo, Hitoshi*; et al.

Journal of Applied Crystallography, 54(2), p.548 - 556, 2021/04

 Times Cited Count:2 Percentile:33.1(Chemistry, Multidisciplinary)

Neutron polarization analysis (NPA) for small-angle neutron scattering (SANS) experiments using a pulsed neutron source was successfully achieved by applying a $$^{3}$$He spin filter as a spin analyzer for the scattered neutrons. The $$^{3}$$He spin filter covers a sufficient solid angle for performing SANS experiments, and the relaxation time of the $$^{3}$$He polarization is sufficient for continuous use over a few days, thus reaching the typical duration required for a complete set of SANS experiments. Although accurate evaluation of the incoherent neutron scattering, which is predominantly attributable to hydrogen atoms in samples, is practically difficult using calculations based on the sample elemental composition, the developed NPA approach with consideration of the influence of multiple neutron scattering enabled reliable decomposition of the SANS intensity distribution into the coherent and incoherent scattering components. To date, NPA has not been well established as a standard technique for SANS experiments at pulsed neutron sources. This work is anticipated to greatly contribute to the accurate determination of the coherent neutron scattering component for scatterers in various types of organic sample systems in SANS experiments at J-PARC.

Journal Articles

Homogeneity of neutron transmission imaging over a large sensitive area with a four-channel superconducting detector

Vu, TheDang; Shishido, Hiroaki*; Kojima, Kenji M*; Koyama, Tomio*; Oikawa, Kenichi; Harada, Masahide; Miyajima, Shigeyuki*; Oku, Takayuki; Soyama, Kazuhiko; Aizawa, Kazuya; et al.

Superconductor Science and Technology, 34(1), p.015010_1 - 015010_10, 2021/01

 Times Cited Count:3 Percentile:27.71(Physics, Applied)

Journal Articles

Energy-resolved neutron imaging using a delay line current-biased kinetic-inductance detector

Shishido, Hiroaki*; Nishimura, Kazuma*; Vu, TheDang*; Kojima, Kenji M*; Koyama, Tomio*; Oikawa, Kenichi; Harada, Masahide; Miyajima, Shigeyuki*; Hidaka, Mutsuo*; Oku, Takayuki; et al.

Journal of Physics; Conference Series, 1590, p.012033_1 - 012033_8, 2020/10

 Times Cited Count:0 Percentile:0.01(Engineering, Electrical & Electronic)

Journal Articles

Development and application of a $$^3$$He neutron spin filter at J-PARC

Okudaira, Takuya; Oku, Takayuki; Ino, Takashi*; Hayashida, Hirotoshi*; Kira, Hiroshi*; Sakai, Kenji; Hiroi, Kosuke; Takahashi, Shingo*; Aizawa, Kazuya; Endo, Hitoshi*; et al.

Nuclear Instruments and Methods in Physics Research A, 977, p.164301_1 - 164301_8, 2020/10

 Times Cited Count:10 Percentile:79.13(Instruments & Instrumentation)

Journal Articles

Energy-resolved neutron imaging with high spatial resolution using a superconducting delay-line kinetic inductance detector

Iizawa, Yuki*; Shishido, Hiroaki*; Nishimura, Kazuma*; Vu, TheDang*; Kojima, Kenji M*; Koyama, Tomio*; Oikawa, Kenichi; Harada, Masahide; Miyajima, Shigeyuki*; Hidaka, Mutsuo*; et al.

Superconductor Science and Technology, 32(12), p.125009_1 - 125009_8, 2019/12

 Times Cited Count:13 Percentile:59.07(Physics, Applied)

Journal Articles

Materials and Life Science Experimental Facility at the Japan Proton Accelerator Research Complex, 3; Neutron devices and computational and sample environments

Sakasai, Kaoru; Sato, Setsuo*; Seya, Tomohiro*; Nakamura, Tatsuya; To, Kentaro; Yamagishi, Hideshi*; Soyama, Kazuhiko; Yamazaki, Dai; Maruyama, Ryuji; Oku, Takayuki; et al.

Quantum Beam Science (Internet), 1(2), p.10_1 - 10_35, 2017/09

Neutron devices such as neutron detectors, optical devices including supermirror devices and $$^{3}$$He neutron spin filters, and choppers are successfully developed and installed at the Materials Life Science Facility (MLF) of the Japan Proton Accelerator Research Complex (J-PARC), Tokai, Japan. Four software components of MLF computational environment, instrument control, data acquisition, data analysis, and a database, have been developed and equipped at MLF. MLF also provides a wide variety of sample environment options including high and low temperatures, high magnetic fields, and high pressures. This paper describes the current status of neutron devices, computational and sample environments at MLF.

JAEA Reports

Proceedings of the 21st Meeting of the International Collaboration on Advanced Neutron Sources (ICANS-XXI); Sep. 29 - Oct.3, 2014, Ibaraki Prefectural Center, Mito, Japan

Oku, Takayuki; Nakamura, Mitsutaka; Sakai, Kenji; Teshigawara, Makoto; Tatsumoto, Hideki*; Yonemura, Masao*; Suzuki, Junichi*; Arai, Masatoshi*

JAEA-Conf 2015-002, 660 Pages, 2016/02

JAEA-Conf-2015-002.pdf:168.34MB

The twenty first meeting of the International Collaboration on Advanced Neutron Source (ICANS-XXI) was held at Ibaraki Prefectural Culture Center in Mito from 29 September to 3 October 2014. It was hosted by Japan Atomic Energy Agency (JAEA), High Energy Accelerator Research Organization (KEK) and Comprehensive Research Organization for Science and Society (CROSS). In the meeting, new science and technology in the new era with the high power neuron sources were discussed in mostly "workshop style" sessions. In each session, various kinds of issues related to not only the hardware, but also the software and even radiation safety were discussed with the keyword of "INTERFACE". More than 200 Papers were presented in the meeting and 72 contributed papers are compiled in the proceedings.

Journal Articles

Development status of the NMR system for the polarized $$^{3}$$He Neutron Spin Filter (NSF) in the MLF at J-PARC

Sakai, Kenji; Oku, Takayuki; Hayashida, Hirotoshi*; Kira, Hiroshi*; Hiroi, Kosuke; Ino, Takashi*; Oyama, Kenji*; Okawara, Manabu*; Kakurai, Kazuhisa; Shinohara, Takenao; et al.

JPS Conference Proceedings (Internet), 8, p.036015_1 - 036015_6, 2015/09

The polarized $$^{3}$$He filter, which polarizes neutrons due to a large neutron absorption cross section of $$^{3}$$He with strong spin selectivity, becomes a convenient neutron spin filter (NSF) because it is operated immediately after its installation in beam lines without any neutron beam adjustments. For realizing such the NSF, a nuclear magnetic resonance (NMR) system is indispensable for monitoring $$^{3}$$He nuclear spin polarization ${it P}$ of the NSF. We have developed the flexible NMR system based on adiabatic fast passage (AFP) and pulse NMR methods by using their complementary features. In comparing with the values of ${it P}$ obtained by neutron transmission measurement at the beam line 10 of the J-PARC, we measured the correlations between the AFP and pulse NMR signals as changing condition of temperature, amplitude and applying period of the radio frequency field for the pulse NMR, and so on. As the results, we confirmed that our system would function enough as the ${it P}$ monitor.

Journal Articles

Development of portable polarized $$^{3}$$He neutron spin filter and its application to magnetic field imaging at J-PARC

Sakai, Kenji; Oku, Takayuki; Hayashida, Hirotoshi; Kira, Hiroshi*; Shinohara, Takenao; Oikawa, Kenichi; Harada, Masahide; Kakurai, Kazuhisa; Aizawa, Kazuya; Arai, Masatoshi; et al.

Journal of Physics; Conference Series, 528, p.012016_1 - 012016_7, 2014/07

 Times Cited Count:2 Percentile:69.29(Optics)

In polarized neutron experiments, it is interested in expanding measurable neutron energy region up to epithermal neutrons. For realizing this situation, a Polarized $$^{3}$$He Spin Flipper (PHSF) has a key role because it can polarize from cold to epithermal neutrons, and flip neutron spins by flipping the $$^{3}$$He nuclear spin direction. We have developed the portable PHSF consisting of a cylindrical glass cell filled with $$^{3}$$He gas which is installed a solenoid coil of 20 cm in diameter and 30 cm long. After polarizing the $$^{3}$$He gas by irradiating a laser light based on a SEOP technique, the PHSF is brought by hands to experimental areas with kept its polarization. We carried out the feasibility test on our portable PHSF in the MLF of J-PARC and demonstrated it worked well by evaluating flipping ratios of polarized neutrons and attempting to visualize magnetic fields generated by sample coils.

Journal Articles

The Present situation and future prospects of groundwater colloids studies on the performance assessment of geological disposal of radioactive wastes in Japan

Nagao, Seiya*; Niibori, Yuichi*; Tanaka, Tadao; Sasaki, Takayuki*; Saito, Takumi*; Kirishima, Akira*; Yoshikawa, Hideki; Iijima, Kazuki; Hama, Katsuhiro; Iwatsuki, Teruki; et al.

Genshiryoku Bakkuendo Kenkyu (CD-ROM), 20(1), p.3 - 14, 2013/06

This paper shows a current status of groundwater colloids studies on the performance assessment of geological disposal of radioactive wastes in Japan, and summaries realistic approach of the colloids studies at a substantial research network for Japanese universities and institutes.

Journal Articles

Isothermal temperature coefficient evaluation for the Monju restart core

Mori, Tetsuya; Maruyama, Shuhei; Hazama, Taira; Suzuki, Takayuki

Nuclear Technology, 179(2), p.286 - 307, 2012/08

 Times Cited Count:11 Percentile:63.41(Nuclear Science & Technology)

The present paper describes the evaluation of the isothermal temperature coefficient data obtained in the Monju restart core. As in the preceding evaluations on the criticality and the control rod worth, the best-estimate value and its uncertainty are evaluated as accurately as possible. Data obtained in the previous test is evaluated in the same level of detail. The measured data shows that the fuel composition change from the previous test decreases the magnitude of the temperature coefficient by $$sim$$8%. Through a sensitivity analysis, it is confirmed that the decrease is mainly brought by the composition of $$^{241}$$Pu and $$^{241}$$Am. The best accuracy within the experimental uncertainty of 2% is attained for the previous core by a calculation with JENDL-4.0. Results for the restart core show inconsistent behavior and require a further investigation.

Journal Articles

Control rod worth evaluation for the Monju restart core

Takano, Kazuya; Fukushima, Masahiro; Hazama, Taira; Suzuki, Takayuki

Nuclear Technology, 179(2), p.266 - 285, 2012/08

 Times Cited Count:9 Percentile:56.92(Nuclear Science & Technology)

The present paper describes the evaluation of the control rod worth data obtained in the Monju restart core. The best-estimate value and its uncertainty are evaluated in detail. As in the criticality evaluation, data obtained in the previous test is evaluated in the same level of detail. The correlation in the uncertainties is also evaluated among different control rods and tests of the previous and the restart cores. Based on the evaluated data, calculation accuracy is investigated with JENDL-3.3 and JENDL-4.0. It is confirmed that the calculation accuracy is within the experimental uncertainty of 2% for each layer and $$^{10}$$B content. A reduction in the uncertainty related to the delayed neutron fraction is effective for a further improvement in the calculation accuracy.

Journal Articles

Development of reactivity feedback effect measurement techniques under sub-critical condition in fast reactors

Kitano, Akihiro; Nishi, Hiroshi; Suzuki, Takayuki; Okajima, Shigeaki; Kanemoto, Shigeru*

Proceedings of International Conference on Physics of Reactors; Advances in Reactor Physics; Linking Research, Industry, and Education (PHYSOR 2012) (CD-ROM), 14 Pages, 2012/04

The "Synthesis Method", a systematic and sophisticated method of sub-criticality measurement, is proposed in this work to ensure the safety margin before operation. The "Synthesis Method" is based on the modified source multiplication method (MSM) combined with the noise analysis method to measure the reference sub-criticality level for MSM. As a result of numerical simulation, it was suggested that a neutron detector located above the core center and three or more neutron detectors located above the radial blanket region enable the measurement of sub-criticality within 10% uncertainty from -0.5 to -2 and within 15% uncertainty for the deeper sub-criticality.

Journal Articles

Development of polarized Xe gas target for neutron experiment at J-PARC

Sakai, Kenji; Oku, Takayuki; Shinohara, Takenao; Kira, Hiroshi; Oi, Motoki; Maekawa, Fujio; Kakurai, Kazuhisa; Ino, Takashi*; Arimoto, Yasushi*; Shimizu, Hirohiko*; et al.

Journal of Physics; Conference Series, 340, p.012037_1 - 012037_7, 2012/02

 Times Cited Count:2 Percentile:62.54(Physics, Condensed Matter)

At the Materials and Life science experimental Facility (MLF) in J-PARC, an experiment of detecting a neutron polarizing ability caused by a neutron-nuclear (n-N) spin correlation term at a resonant peak of $$^{129}$$Xe is planned. The Xe gas having a high polarization under low magnetic field and room temperature by a spin exchange optical pumping (SEOP) technique is expected to become a suitable target for verification of the neutron optical theorem (NOPT). We evaluated measurable quantities based on the NOPT, developed a polarized Xe gas system, and carried out a feasibility test of our apparatus. This paper reports on the present status of the experiment.

JAEA Reports

Uncertainty quantification of Doppler coefficient for MONJU

Chiba, Go*; Hazama, Taira; Kinjo, Hidehito*; Nishi, Hiroshi; Suzuki, Takayuki

JAEA-Research 2011-034, 42 Pages, 2011/12

JAEA-Research-2011-034.pdf:1.88MB

Uncertainty of Doppler coefficient is quantified for a Monju core, reflecting present knowledge. Various uncertainty sources are evaluated: (1) Nuclear data and numerical method, (2) Fission product nuclear data, (3) Control rod position, (4) Approximated treatment of temperature dependence, (5) Averaged fuel temperature, (6) Approximated treatment of temperature spatial distribution, etc. Resulting uncertainty for Doppler coefficient is estimated at 11.7% for the 2 $$sigma$$ reliability.

166 (Records 1-20 displayed on this page)