Yamano, Hidemasa; Xu, Y.*; Sago, Hiromi*; Hirota, Kazuo*; Baba, Takeo*
Proceedings of 2016 International Congress on Advances in Nuclear Power Plants (ICAPP 2016) (CD-ROM), p.1029 - 1038, 2016/04
This study conducted the flow-induced vibration evaluation of the primary hot-leg piping in the demonstration reactor design of advanced loop-type sodium-cooled fast reactor in order to confirm the integrity of the piping. Following the description of the primary hot-leg piping design and a design guideline of the flow-induced vibration evaluation, this paper describes mainly the flow-induced vibration evaluation and thereby the integrity assessment. In the fatigue evaluation for the flow-induced vibration, the pipe stresses considering the stress concentration factor and so on, at representative locations were less than the design fatigue limit. Therefore, this evaluation confirmed the integrity of the primary hot-leg piping in the demonstration reactor.
Baba, Takeo*; Hirota, Kazuo*; Sago, Hiromi*; Yamano, Hidemasa; Aizawa, Kosuke; Xu, Y.*
Proceedings of 19th International Conference on Nuclear Engineering (ICONE-19) (CD-ROM), 9 Pages, 2011/10
Baba, Takeo*; Hirota, Kazuo*; Sago, Hiromi*; Yamano, Hidemasa; Aizawa, Kosuke; Xu, Y.*
no journal, ,
no abstracts in English
Hirota, Kazuo*; Baba, Takeo*; Sago, Hiromi*; Xu, Y.*; Kaneko, Tetsuya; Yamano, Hidemasa
no journal, ,
no abstracts in English
Baba, Takeo*; Hirota, Kazuo*; Sago, Hiromi*; Xu, Y.*; Yamano, Hidemasa; Kaneko, Tetsuya
no journal, ,
no abstracts in English
Xu, Y.*; Sago, Hiromi*; Hirota, Kazuo*; Baba, Takeo*; Yamano, Hidemasa
no journal, ,
Structural integrity evaluation has been carried out for a hot-leg pipe due to random vibration induced by turbulence of pipe flow using "proposed guideline of flow-induced vibration evaluation for the primary hot-leg piping in sodium-cooled fast reactor", which has reflected the R&D results of the flow-induced vibration for a large-diameter piping. This gave the prospect of integrity of the primary hot-leg piping in the demonstration fast reactor.