Refine your search:     
Report No.
 - 
Search Results: Records 1-16 displayed on this page of 16
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

The Japan Health Physics Society Guideline on Dose Monitoring for the Lens of the Eye

Yokoyama, Sumi*; Tsujimura, Norio; Hashimoto, Makoto; Yoshitomi, Hiroshi; Kato, Masahiro*; Kurosawa, Tadahiro*; Tatsuzaki, Hideo*; Sekiguchi, Hiroshi*; Koguchi, Yasuhiro*; Ono, Koji*; et al.

Journal of Radiation Protection and Research, 47(1), p.1 - 7, 2022/03

Background: In Japan, new regulations that revise the dose limit for the lens of the eye (the lens), operational quantities, and measurement positions for the lens dose were enforced in April 2021. Based on the international safety standards, national guidelines, the results of the Radiation Safety Research Promotion Fund of the Nuclear Regulatory Authority, and other studies, the Working Group of Radiation Protection Standardization Committee, the Japan Health Physics Society (JHPS) developed a guideline for radiation dose monitoring for the lens. Materials and Methods: The Working Group of the JHPS discussed the criteria of non-uniform exposure and the management criteria set to not exceed the dose limit for the lens. Results and Discussion: In July 2020, the JHPS guideline was published. The guideline consists of three parts: main text, explanations, and 26 questions. In the questions, the corresponding answers were prepared, and specific examples were provided to enable similar cases to be addressed. Conclusion: With the development of guideline on radiation dose monitoring of the lens, radiation managers and workers will be able to smoothly comply with revised regulations and optimise radiation protection.

Journal Articles

Development of guidelines on radiation protection for the lens of the eye in Japan

Yokoyama, Sumi*; Iwai, Satoshi*; Tsujimura, Norio; Hashimoto, Makoto; Yoshitomi, Hiroshi; Kato, Masahiro*; Kurosawa, Tadahiro*; Tatsuzaki, Hideo*; Sekiguchi, Hiroshi*; Koguchi, Yasuhiro*; et al.

Proceedings of 15th International Congress of the International Radiation Protection Association (IRPA-15) (Internet), 8 Pages, 2022/00

Journal Articles

Hydrogen absorption mechanism into iron in aqueous solution including metal cations by laser ablation tests and first-principles calculations

Igarashi, Takahiro; Otani, Kyohei; Kato, Chiaki; Sakairi, Masatoshi*; Togashi, Yusuke*; Baba, Kazuhiko*; Takagi, Shusaku*

ISIJ International, 61(4), p.1085 - 1090, 2021/04

 Times Cited Count:1 Percentile:7.67(Metallurgy & Metallurgical Engineering)

In order to clarify the effect of metal cations (Zn$$^{2+}$$, Mg$$^{2+}$$, Na$$^{+}$$) in aqueous solution on hydrogen permeation into iron, the amount of hydrogen permeation from iron surface was measured by electrochemical tests with a laser ablation. Moreover, in order to obtain the basic mechanism of hydrogen permeation with metal cation, first-principles calculations were used to acquire the adsorption potential of the metal cation and the electronic state around iron surface. By Zn$$^{2+}$$ in solution, anodic reaction on ablated surface by laser irradiation was suppressed. Also, by quantum analysis Zn atoms were chemically bonded stronger than Na and Mg atoms to iron surface. It was suggested that the dissolution reaction of iron was suppressed by the formation of the Zn layer, and that lead suppression of hydrogen permeation into iron.

Journal Articles

Thermally altered subsurface material of asteroid (162173) Ryugu

Kitazato, Kohei*; Milliken, R. E.*; Iwata, Takahiro*; Abe, Masanao*; Otake, Makiko*; Matsuura, Shuji*; Takagi, Yasuhiko*; Nakamura, Tomoki*; Hiroi, Takahiro*; Matsuoka, Moe*; et al.

Nature Astronomy (Internet), 5(3), p.246 - 250, 2021/03

 Times Cited Count:44 Percentile:97.1(Astronomy & Astrophysics)

Here we report observations of Ryugu's subsurface material by the Near-Infrared Spectrometer (NIRS3) on the Hayabusa2 spacecraft. Reflectance spectra of excavated material exhibit a hydroxyl (OH) absorption feature that is slightly stronger and peak-shifted compared with that observed for the surface, indicating that space weathering and/or radiative heating have caused subtle spectral changes in the uppermost surface. However, the strength and shape of the OH feature still suggests that the subsurface material experienced heating above 300 $$^{circ}$$C, similar to the surface. In contrast, thermophysical modeling indicates that radiative heating does not increase the temperature above 200 $$^{circ}$$C at the estimated excavation depth of 1 m, even if the semimajor axis is reduced to 0.344 au. This supports the hypothesis that primary thermal alteration occurred due to radiogenic and/or impact heating on Ryugu's parent body.

Journal Articles

The Surface composition of asteroid 162173 Ryugu from Hayabusa2 near-infrared spectroscopy

Kitazato, Kohei*; Milliken, R. E.*; Iwata, Takahiro*; Abe, Masanao*; Otake, Makiko*; Matsuura, Shuji*; Arai, Takehiko*; Nakauchi, Yusuke*; Nakamura, Tomoki*; Matsuoka, Moe*; et al.

Science, 364(6437), p.272 - 275, 2019/04

 Times Cited Count:262 Percentile:99.73(Multidisciplinary Sciences)

The near-Earth asteroid 162173 Ryugu, the target of Hayabusa2 sample return mission, is believed to be a primitive carbonaceous object. The Near Infrared Spectrometer (NIRS3) on Hayabusa2 acquired reflectance spectra of Ryugu's surface to provide direct measurements of the surface composition and geological context for the returned samples. A weak, narrow absorption feature centered at 2.72 micron was detected across the entire observed surface, indicating that hydroxyl (OH)-bearing minerals are ubiquitous there. The intensity of the OH feature and low albedo are similar to thermally- and/or shock-metamorphosed carbonaceous chondrite meteorites. There are few variations in the OH-band position, consistent with Ryugu being a compositionally homogeneous rubble-pile object generated from impact fragments of an undifferentiated aqueously altered parent body.

Journal Articles

NIRS3; The Near Infrared Spectrometer on Hayabusa2

Iwata, Takahiro*; Kitazato, Kohei*; Abe, Masanao*; Otake, Makiko*; Arai, Takehiko*; Arai, Tomoko*; Hirata, Naru*; Hiroi, Takahiro*; Honda, Chikatoshi*; Imae, Naoya*; et al.

Space Science Reviews, 208(1-4), p.317 - 337, 2017/07

 Times Cited Count:54 Percentile:71.62(Astronomy & Astrophysics)

NIRS3: The Near Infrared Spectrometer is installed on the Hayabusa2 spacecraft to observe the target C-type asteroid 162173 Ryugu at near infrared wavelengths of 1.8 to 3.2 micrometer. It aims to obtain reflectance spectra in order to detect absorption bands of hydrated and hydroxide minerals in the 3 micrometer-band. We adopted a linear-image sensor with indium arsenide (InAs) photo diodes and a cooling system with a passive radiator to achieve an optics temperature of 188 K, which enables to retaining sufficient sensitivity and noise level in the 3 micrometer wavelength region. We conducted ground performance tests for the NIRS3 flight model (FM) to confirm its baseline specifications. The results imply that the properties such as the signal-to-noise ratio (SNR) conform to scientific requirements to determine the degree of aqueous alteration, such as CM or CI chondrite, and the stage of thermal metamorphism on the asteroid surface.

Journal Articles

Comparison between Monte Carlo simulation and measurement with a 3D polymer gel dosimeter for dose distributions in biological samples

Furuta, Takuya; Maeyama, Takuya*; Ishikawa, Kenichi*; Fukunishi, Nobuhisa*; Fukasaku, Kazuaki*; Takagi, Shu*; Noda, Shigeho*; Himeno, Ryutaro*; Hayashi, Shinichiro*

Physics in Medicine & Biology, 60(16), p.6531 - 6546, 2015/08

 Times Cited Count:19 Percentile:62.37(Engineering, Biomedical)

Low reproducibility of dose distribution in inhomogeneous regions such as soft matter near bones is known with the simple dose analysis currently adopted in treatment planning of particle cancer therapy. Therefore a treatment planning system based on Monte Carlo simulation having better accuracy is highly desired. In order to assess the simulation accuracy of a Monte Carlo simulation code in situations closely related to medical application, we performed a comparison of dose distribution in a biological sample obtained by experiment and that by simulation. In particular, we irradiate a carbon beam on a biological sample composed of fresh chicken meat and bones, with a PAGAT gel dosimeter placed behind it, and compare the complex dose distribution in the gel dosimeter created by the beam passing through the inhomogeneous sample. Monte Carlo simulation using PHITS code was conducted by reconstructing the biological sample from its computed tomography images. The simulation accurately reproduced the experimental distal edge structure of the dose distribution with an accuracy under about 2 mm.

Journal Articles

Engineering a spin-orbital magnetic insulator by tailoring superlattices

Matsuno, Jobu*; Ihara, Kota*; Yamamura, Shugen*; Wadachi, Hiroki*; Ishii, Kenji; Shankar, V.*; Kee, H.-Y.*; Takagi, Hidenori*

Physical Review Letters, 114(24), p.247209_1 - 247209_5, 2015/06

 Times Cited Count:150 Percentile:97.75(Physics, Multidisciplinary)

Journal Articles

Parallel computing with Particle and Heavy Ion Transport code System (PHITS)

Furuta, Takuya; Sato, Tatsuhiko; Ogawa, Tatsuhiko; Niita, Koji*; Ishikawa, Kenichi*; Noda, Shigeho*; Takagi, Shu*; Maeyama, Takuya*; Fukunishi, Nobuhisa*; Fukasaku, Kazuaki*; et al.

Proceedings of Joint International Conference on Mathematics and Computation, Supercomputing in Nuclear Applications and the Monte Carlo Method (M&C + SNA + MC 2015) (CD-ROM), 9 Pages, 2015/04

In Particle and Heavy Ion Transport code System PHITS, two parallel computing functions are prepared to reduce the computational time. One is the distributed-memory parallelization using message passing interface (MPI) and the other is the shared-memory parallelization using OpenMP directives. Each function has advantages and disadvantages, and thus, by adopting both functions in PHITS, it is possible to conduct parallel computing suited for needs of users. It is also possible to conduct the hybrid parallelization by the intra-node OpenMP parallelization and the inter-node MPI parallelization in supercomputer systems. Each parallelization functions were explained together with some application results obtained using a workstation and a supercomputer system, K computer at RIKEN.

Journal Articles

Radiological characteristics of MRI-based VIP polymer gel under carbon beam irradiation

Maeyama, Takuya*; Fukunishi, Nobuhisa*; Ishikawa, Kenichi*; Furuta, Takuya; Fukasaku, Kazuaki*; Takagi, Shu*; Noda, Shigeho*; Himeno, Ryutaro*; Fukuda, Shigekazu*

Radiation Physics and Chemistry, 107, p.7 - 11, 2015/02

 Times Cited Count:12 Percentile:70.16(Chemistry, Physical)

We study the radiological characteristics of VIP polymer gel dosimeters under carbon beam irradiation with energy of 135 and 290 AMeV. To evaluate dose response of VIP polymer gels, the transverse relaxation rate R2 of the dosimeters measured by magnetic resonance imaging (MRI) as a function of linear energy transfer (LET), rather than penetration depth, as is usually done in previous reports. LET is evaluated by use of the particle transport simulation code PHITS. Our results reveal that the dose response decreases with increasing dose-averaged LET and that the response-LET relation also varies with incident carbon beam energy. The latter can be explained by taking into account the contribution from fragmentation products. Furthermore, as an application of the evaluated response-LET relation, we compare the measured and simulated R2 distribution in a VIP gel formed by heterogeneous irradiation and obtain agreement in overall distribution and range within an accuracy of 5% and 1-2 mm, respectively.

Oral presentation

Fission study by multi-nucleon transfer reaction at JAEA

Hirose, Kentaro; Nishio, Katsuhisa; L$'e$guillon, R.; Makii, Hiroyuki; Nishinaka, Ichiro; Orlandi, R.; Smallcombe, J.; Ishii, Tetsuro; Tsukada, Kazuaki; Asai, Masato; et al.

no journal, , 

Oral presentation

Response of soil microbial community to climate change

Kondo, Toshiaki*; Teramoto, Munemasa*; Nakane, Kaneyuki*; Takagi, Kentaro*; Koarashi, Jun; Atarashi-Andoh, Mariko; Takagi, Masahiro*; Ishida, Sachinobu*; Liang, N.*

no journal, , 

Oral presentation

Long-term soil warming effect on soil organic carbon decomposition in Asian Monsoon forests

Teramoto, Munemasa*; Liang, N.*; Takagi, Kentaro*; Kondo, Toshiaki*; Kondo, Toshiaki*; Koarashi, Jun; Atarashi-Andoh, Mariko; Takagi, Masahiro*; Ishida, Sachinobu*; Naramoto, Masaaki*; et al.

no journal, , 

Oral presentation

Upscaling of soil respiration in Japan

Ichii, Kazuhito*; Yamanuki, Hina*; Liang, N.*; Teramoto, Munemasa*; Takahashi, Yoshiyuki*; Zeng, J.*; Takagi, Kentaro*; Hirano, Takashi*; Ishida, Sachinobu*; Takagi, Masahiro*; et al.

no journal, , 

no abstracts in English

Oral presentation

Intercomparison of data-driven estimation of soil respiration in Japan

Yamanuki, Hina*; Ichii, Kazuhito*; Liang, N.*; Teramoto, Munemasa*; Takahashi, Yoshiyuki*; Zeng, J.*; Takagi, Kentaro*; Hirano, Takashi*; Ishida, Sachinobu*; Takagi, Masahiro*; et al.

no journal, , 

Oral presentation

Spectral characteristics of asteroid (162173) Ryugu with Hayabusa2 NIRS3

Takir, D.*; Kitazato, Kohei*; Milliken, R. E.*; Iwata, Takahiro*; Abe, Masanao*; Otake, Makiko*; Matsuura, Shuji*; Arai, Takehiko*; Nakauchi, Yusuke*; Nakamura, Tomoki*; et al.

no journal, , 

JAXA spacecraft and sample return mission Hayabusa2 has arrived at the near-Earth asteroid 162173 Ryugu, which is classified a primitive carbonaceous object. Here we report recent results of near-infrared spectrometer (NIRS3) on the Hayabusa2 spacecraft. The observations provide direct measurements of the surface composition of Ryugu and context for the returned samples. NIRS3 has detected a weak and narrow absorption feature centered at 2.72 micrometer across entire observed surface. This absorption feature is attributed to the presence of OH-bearing minerals. The NIRS3 observations also revealed that Ryugu is the darkest object to be observed up-close by a visiting spacecraft. The intensity of the OH feature and low albedo are consistent with thermally-and/or shock-metamorphosed, and/or carbon-rich space-weathered primitive and hydrated carbonaceous chondrites.

16 (Records 1-16 displayed on this page)
  • 1