Refine your search:     
Report No.
 - 
Search Results: Records 1-6 displayed on this page of 6
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Computational evaluation of peak efficiencies for a whole-body counter with scanning germanium detectors

Kurihara, Osamu; Takasaki, Koji; Momose, Takumaro; Terakado, Yoshinori*; Takahashi, Koji*

Journal of Nuclear Science and Technology, 41(Suppl.4), p.243 - 246, 2004/03

None

Journal Articles

Evaluation of Detection Characteristics for Ge Scanning-Type Whole-Body Counter by Monte-Carlo Simulation

Kurihara, Osamu; Takasaki, Koji; Momose, Takumaro; Terakado, Yoshinori*; Takahashi, Koji*

IRPA-11, 0 Pages, 2004/00

As an alternative to the phantom used for calibrating whole-body counters, in this study the Monte Carlo simulation was used to evaluate peak efficiencies for a whole-body counter installed at the JNC, to examine the validity of using the simulation technique to calibrate the whole-body counter. Prior to simulating a phantom, the sensitive region of the crystal in the Ge detectors which are used with the whole-body counter, was evaluated by assuming dead layers in the simulation. The phantom was then simulated based on the determined configuration of the sensitive region. As a result, the calculated peak efficiencies were fairly consistent with the measured ones. For an entire body scanning measurement, the discrepancy between the measurement and the simulation was within 4% for peak energies ranging from 81.0 keV to 1460.8 keV. The simulation technique is therefore both effective and practical for situations that are difficult to be simulated by a phantom.

Journal Articles

Determination of detection efficiency curve for a gas monitor with a built-in germanium detector

Oishi, Tetsuya; Yoshida, Makoto; Saegusa, Jun; Honda, Tetsutaro*; Takahashi, Koji*; Kuwabara, H.*

Journal of Nuclear Science and Technology, 38(3), p.203 - 208, 2001/03

no abstracts in English

Journal Articles

A Calibration technique for radioactive gas monitor with a built-in germanium detector

Yoshida, Makoto; Oishi, Tetsuya; Saegusa, Jun; Honda, Tetsutaro*; Takahashi, Koji*; Kuwabara, H.*

Proceedings of 10th International Congress of the International Radiation Protection Association (IRPA-10) (CD-ROM), 6 Pages, 2000/05

no abstracts in English

Journal Articles

PopTop-type germanium detector cooled by stirling refrigerators

Katagiri, Masaki; Kobayashi, Yoshii; Takahashi, Koji*; *; *

KEK-Proceedings 96-4, 0, p.209 - 213, 1996/07

no abstracts in English

Journal Articles

Radiation characteristics of tritium plane sources for calibration of surface contamination monitoring instruments

Yoshida, Makoto; Takahashi, Koji*;

Radioisotopes, 43(12), p.741 - 749, 1994/12

no abstracts in English

6 (Records 1-6 displayed on this page)
  • 1