Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 99

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Neutron/$$gamma$$-ray discrimination based on the property and thickness controls of scintillators using Li glass and LiCAF(Ce) in a $$gamma$$-ray field

Kaburagi, Masaaki; Shimazoe, Kenji*; Terasaka, Yuta; Tomita, Hideki*; Yoshihashi, Sachiko*; Yamazaki, Atsushi*; Uritani, Akira*; Takahashi, Hiroyuki*

Nuclear Instruments and Methods in Physics Research A, 1046, p.167636_1 - 167636_8, 2023/01

 Times Cited Count:3 Percentile:90.12(Instruments & Instrumentation)

We focus on the thickness and property controls of inorganic scintillators used for thermal neutron detection in intense $$gamma$$-ray fields without considering pulse shape discrimination techniques. GS20$$^{rm{TM}}$$ (a lithium glass) and LiCaAlF$$_6$$:Ce(LiCAF:Ce) cintillators with thicknesses of 0.5 and 1.0 mm, respectively, have been employed. Pulse signals generated by photomultiplier tubes, to which the scintillators were coupled, were inserted into a digital pulse processing unit with 1 Gsps, and the areas of waveforms were integrated for 360 ns. In a $$^{60}$$Co $$gamma$$-ray field, the neutron detection for GS20$$^{rm{TM}}$$ with a 0.5-mm thickness was possible at dose rates of up to 0.919 Gy/h; however, for LiCAF:Ce, neutron detection was possible at 0.473 Gy/h, and it failed at 0.709 Gy/h. Threfore, in a $$^{60}$$Co $$gamma$$-ray field, the neutron/$$gamma$$-ray discrimination of GS20$$^{rm{TM}}$$ was better than that of LiCAF:Ce due to its better energy resolution and higher detection efficiency.

Journal Articles

Identification and quantification of a $$^{60}$$Co radiation source under an intense $$^{137}$$Cs radiation field using an application-specific CeBr$$_3$$ spectrometer suited for use in intense radiation fields

Kaburagi, Masaaki; Shimazoe, Kenji*; Kato, Masahiro*; Kurosawa, Tadahiro*; Takahashi, Hiroyuki*

Journal of Nuclear Science and Technology, 59(8), p.983 - 992, 2022/08

 Times Cited Count:0 Percentile:0.01(Nuclear Science & Technology)

Journal Articles

Development of the multi-cubic $$gamma$$-ray spectrometer and its performance under intense $$^{137}$$Cs and $$^{60}$$Co radiation fields

Kaburagi, Masaaki; Shimazoe, Kenji*; Kato, Masahiro*; Kurosawa, Tadahiro*; Kamada, Kei*; Kim, K. J.*; Yoshino, Masao*; Shoji, Yasuhiro*; Yoshikawa, Akira*; Takahashi, Hiroyuki*

Nuclear Instruments and Methods in Physics Research A, 1010, p.165544_1 - 165544_9, 2021/09

 Times Cited Count:0 Percentile:0.02(Instruments & Instrumentation)

The number of nuclear facilities being decommissioned has been increasing worldwide, in particular following the accident of the Tokyo Electric Power Company Holdings' Fukushima Daiichi Nuclear Power Station in 2011. In these nuclear facilities, proper management of radioactive materials is required. Then, A $$gamma$$-ray spectrometer with four segmentations using small volume CeBr$$_{3}$$ scintillators with a dimension of $$5 times 5 times 5$$ $$rm{mm}^3$$ was developed. The four scintillators were coupled to a multi-anode photomultiplier tube specific to intense radiation fields. We performed the $$gamma$$-ray exposure study under $$^{137}$$Cs and $$^{60}$$Co radiation fields. Under the $$^{137}$$Cs radiation field, the relative energy resolution at 1375 mSv/h was the relative energy resolution at 1375 mSv/h was 9.2$$pm$$0.05%, 8.0$$pm$$0.08%, 8.0$$pm$$0.03%, and 9.0$$pm$$0.04% for the four channels, respectively.

Journal Articles

Gamma-ray spectroscopy with a CeBr$$_3$$ scintillator under intense $$gamma$$-ray fields for nuclear decommissioning

Kaburagi, Masaaki; Shimazoe, Kenji*; Kato, Masahiro*; Kurosawa, Tadahiro*; Kamada, Kei*; Kim, K. J.*; Yoshino, Masao*; Shoji, Yasuhiro*; Yoshikawa, Akira*; Takahashi, Hiroyuki*; et al.

Nuclear Instruments and Methods in Physics Research A, 988, p.164900_1 - 164900_8, 2021/02

 Times Cited Count:11 Percentile:89.29(Instruments & Instrumentation)

An increasing number of nuclear facilities have been decommissioned worldwide following the 2011 accident of the TEPCO' Fukushima Daiichi Nuclear Power Station. During the decommissioning, radioactive materials have to be retrieved under proper management. In this study, a small cubic CeBr$$_3$$ spectrometer with dimensions of 5 mm $$times$$ 5 mm $$times$$ 5 mm was manufactured to perform $$gamma$$-ray spectroscopy under intense $$gamma$$-ray fields. Furthermore, thanks to a fast digital process unit and a customized photomultiplier, the device could perform $$gamma$$-ray spectroscopy at dose rates of over 1 Sv/h. The energy resolution (FWHM) at 662 keV ranged from 4.4% at 22 mSv/h to 5.2% at 1407 mSv/h for a $$^{137}$$Cs radiation field. Correspondingly, at 1333 keV, it ranged from 3.1% at 26 mSv/h to 4.2% at 2221 mSv/h for a $$^{60}$$Co radiation field, which suggested to realize $$gamma$$-ray assessment of $$^{134}$$Cs, $$^{137}$$Cs, $$^{60}$$Co, and $$^{154}$$Eu at dose rates of over 1 Sv/h.

Journal Articles

A Cubic CeBr$$_{3}$$ gamma-ray spectrometer suitable for the decommissioning of the Fukushima Daiichi Nuclear Power Station

Kaburagi, Masaaki; Shimazoe, Kenji*; Otaka, Yutaka*; Uenomachi, Mizuki*; Kamada, Kei*; Kim, K. J.*; Yoshino, Masao*; Shoji, Yasuhiro*; Yoshikawa, Akira*; Takahashi, Hiroyuki*; et al.

Nuclear Instruments and Methods in Physics Research A, 971, p.164118_1 - 164118_8, 2020/08

 Times Cited Count:7 Percentile:66.68(Instruments & Instrumentation)

Journal Articles

Pre- and post-accident $$^{14}$$C activities in tree rings near the Fukushima Dai-ichi Nuclear Power Plant

Matsunaka, Tetsuya*; Sasa, Kimikazu*; Takahashi, Tsutomu*; Matsumura, Masumi*; Satou, Yukihiko; Shen, H.*; Sueki, Keisuke*; Matsuzaki, Hiroyuki*

Radiocarbon, 61(6), p.1633 - 1642, 2019/12

 Times Cited Count:2 Percentile:11.66(Geochemistry & Geophysics)

Journal Articles

Development of compact high field pulsed magnet system for new sample environment equipment at MLF in J-PARC

Watanabe, Masao; Nojiri, Hiroyuki*; Ito, Shinichi*; Kawamura, Seiko; Kihara, Takumi*; Masuda, Takatsugu*; Sahara, Takuro*; Soda, Minoru*; Takahashi, Ryuta

JPS Conference Proceedings (Internet), 25, p.011024_1 - 011024_5, 2019/03

Recently, neutron scattering experiments have been rapidly progressed under high magnetic field. In the J-PARC, proto-type compact pulse magnet system with the power supply, the coil and the sample stick has been developed. Basic specifications of the power supply are as follows; maximum charged voltage with capacitor is 2 kV, maximum current is 8 kA, repetition rate is a pulse per several minutes and pulse duration is several msec. Maximum magnetic field in the coil is more than 30 Tesla. The sample stick is designed for Orange-Cryostat. In this presentation, We report the details of the pulsed magnet system and the performance of it on neutron scattering experiments at MLF beam line (HRC).

Journal Articles

Gamma-ray imaging system for Fukushima Daiichi Nuclear Power Plant using silicon strip detector

Kaburagi, Masaaki; Sato, Yuki; Yoshihara, Yuri*; Shimazoe, Kenji*; Takahashi, Hiroyuki*; Torii, Tatsuo

Reactor Dosimetry; 16th International Symposium on Reactor Dosimetry (ISRD-16) (ASTM STP 1608), p.405 - 414, 2018/11

 Times Cited Count:0 Percentile:0.05(Nuclear Science & Technology)

Journal Articles

Field test around Fukushima Daiichi Nuclear Power Plant site using improved Ce:Gd$$_{3}$$(Al,Ga)$$_{5}$$O$$_{12}$$ scintillator Compton camera mounted on an unmanned helicopter

Shikaze, Yoshiaki; Nishizawa, Yukiyasu; Sanada, Yukihisa; Torii, Tatsuo; Jiang, J.*; Shimazoe, Kenji*; Takahashi, Hiroyuki*; Yoshino, Masao*; Ito, Shigeki*; Endo, Takanori*; et al.

Journal of Nuclear Science and Technology, 53(12), p.1907 - 1918, 2016/12

 Times Cited Count:37 Percentile:96.48(Nuclear Science & Technology)

The Compton camera was improved for use with the unmanned helicopter. Increase of the scintillator array from 4$$times$$4 to 8$$times$$8 and expanse of the distance between the two layers contributed to the improvements of detection efficiency and angular resolution, respectively. Measurements were performed over the riverbed of the Ukedo river of Namie town in Fukushima Prefecture. By programming of flight path and speed, the areas of 65 m $$times$$ 60 m and 65 m $$times$$ 180 m were measured during about 20 and 30 minutes, respectively. By the analysis the air dose rate maps at 1 m height were obtained precisely with the angular resolution corresponding to the position resolution of about 10 m from 10 m height. Hovering flights were executed over the hot spot areas for 10-20 minutes at 5-20 m height. By using the reconstruction software the $$gamma$$-ray images including the hot spots were obtained with the angular resolution same as that evaluated in the laboratory (about 10$$^{circ}$$).

Journal Articles

Age and speciation of iodine in groundwater and mudstones of the Horonobe area, Hokkaido, Japan; Implications for the origin and migration of iodine during basin evolution

Togo, Yoko*; Takahashi, Yoshio*; Amano, Yuki; Matsuzaki, Hiroyuki*; Suzuki, Yohei*; Terada, Yasuko*; Muramatsu, Yasuyuki*; Ito, Kazumasa*; Iwatsuki, Teruki

Geochimica et Cosmochimica Acta, 191, p.165 - 186, 2016/10

 Times Cited Count:28 Percentile:73.1(Geochemistry & Geophysics)

Iodine distribution, speciation, and isotope ratio ($$^{129}$$I/$$^{127}$$I) in both rock and groundwater phases were determined to investigate long-term migration of iodine in diatomaceous and siliceous shale. It was suggested that I$$^{-}$$ is released to the ground water during the progress of the maturation of organic matter. Dissociated I$$^{-}$$ could move toward the surface because of the upward water flow driven by the compaction during burial diagenetic process. Thus, iodine rich brine is created by integration of iodine released from underlying formations. Because of low affinity of I$$^{-}$$ to solid phase, released I$$^{-}$$ remains in solution phase, and the concentration of the iodine in the solution has been possibly increasing during sedimentation history.

JAEA Reports

Research for spectroscopy of fuel debris using superconducting phase transition edge sensor microcalorimeter; Measurement experiment and simulated calculation (Joint research)

Takasaki, Koji; Yasumune, Takashi; Onishi, Takashi; Nakamura, Keisuke; Ishimi, Akihiro; Ito, Chikara; Osaka, Masahiko; Ono, Masashi*; Hatakeyama, Shuichi*; Takahashi, Hiroyuki*; et al.

JAEA-Research 2013-043, 33 Pages, 2014/01

JAEA-Research-2013-043.pdf:13.81MB

In the Fukushima Daiichi Nuclear Power Plant, it is assumed that the core fuels melted partially or wholly, and the normal technique of accounting for a fuel assembly is not applicable. Therefore, it is necessary to develop the transparent and rational technique of accounting in the process of collection and storage of fuel debris. In this research, an application of the superconducting phase Transition Edge Sensor microcalorimeter (TES microcalorimeter) is studied for the accounting of nuclear materials in the fuel debris. It is expected that the detailed information of nuclear materials and fission products in fuel debris is obtained by using a high-resolution characteristic of TES microcalorimeter. In this report, the principle of TES microcalorimeter, the measurement experiment using TES in JAEA, and the simulated calculation using the EGS5 code system are summarized.

Journal Articles

Controls over structural and electronic properties of epitaxial graphene on silicon using surface termination of 3C-SiC(111)/Si

Fukidome, Hirokazu*; Abe, Shunsuke*; Takahashi, Ryota*; Imaizumi, Kei*; Inomata, Shuya*; Handa, Hiroyuki*; Saito, Eiji*; Enta, Yoshiharu*; Yoshigoe, Akitaka; Teraoka, Yuden; et al.

Applied Physics Express, 4(11), p.115104_1 - 115104_3, 2011/11

 Times Cited Count:35 Percentile:78.45(Physics, Applied)

Journal Articles

Control of epitaxy of graphene by crystallographic orientation of a Si substrate toward device applications

Fukidome, Hirokazu*; Takahashi, Ryota*; Abe, Shunsuke*; Imaizumi, Kei*; Handa, Hiroyuki*; Kang, H. C.*; Karasawa, Hiromi*; Suemitsu, Tetsuya*; Otsuji, Taiichi*; Enta, Yoshiharu*; et al.

Journal of Materials Chemistry, 21(43), p.17242 - 17248, 2011/11

 Times Cited Count:28 Percentile:63.34(Chemistry, Physical)

Journal Articles

Low-energy-electron-diffraction and X-ray-phototelectron-spectroscopy studies of graphitization of 3C-SiC(111) thin film on Si(111) substrate

Takahashi, Ryota*; Handa, Hiroyuki*; Abe, Shunsuke*; Imaizumi, Kei*; Fukidome, Hirokazu*; Yoshigoe, Akitaka; Teraoka, Yuden; Suemitsu, Maki*

Japanese Journal of Applied Physics, 50(7), p.070103_1 - 070103_6, 2011/07

 Times Cited Count:31 Percentile:75.34(Physics, Applied)

Journal Articles

Oxygen-induced reduction of the graphitization temperature of SiC surface

Imaizumi, Kei*; Handa, Hiroyuki*; Takahashi, Ryota*; Saito, Eiji*; Fukidome, Hirokazu*; Enta, Yoshiharu*; Teraoka, Yuden; Yoshigoe, Akitaka; Suemitsu, Maki*

Japanese Journal of Applied Physics, 50(7), p.070105_1 - 070105_6, 2011/07

 Times Cited Count:4 Percentile:19.03(Physics, Applied)

Journal Articles

Feasible evaluation of neutron capture therapy for hepatocellular carcinoma using selective enhancement of boron accumulation in tumour with intra-arterial administration of boron-entrapped water-in-oil-in-water emulsion

Yanagie, Hironobu*; Kumada, Hiroaki*; Nakamura, Takemi; Higashi, Shushi*; Ikushima, Ichiro*; Morishita, Yasuyuki*; Shinohara, Atsuko*; Fujiwara, Mitsuteru*; Suzuki, Minoru*; Sakurai, Yoshinori*; et al.

Proceedings of 14th International Congress on Neutron Capture Therapy (ICNCT-14) (CD-ROM), p.157 - 160, 2010/10

Journal Articles

Innovative alpha radioactivity monitor for clearance level inspection based on ionized air transport technology; CFD-simulated and experimental ion transport efficiencies for uranium-attached pipes

Hirata, Yosuke*; Nakahara, Katsuhiko*; Sano, Akira*; Sato, Mitsuyoshi*; Aoyama, Yoshio; Miyamoto, Yasuaki; Yamaguchi, Hiromi; Nambu, Kenichi*; Takahashi, Hiroyuki*; Oda, Akinori*

Journal of Power and Energy Systems (Internet), 2(2), p.561 - 572, 2008/00

Journal Articles

Innovative alpha-radioactivity monitor for clearance level inspection based on ionized air transportation technology, 1; Comparison with mass spectral analysis using uranium-attached samples

Aoyama, Yoshio; Miyamoto, Yasuaki; Yamaguchi, Hiromi; Sano, Akira*; Naito, Susumu*; Sumida, Akio*; Izumi, Mikio*; Maekawa, Tatsuyuki*; Sato, Mitsuyoshi*; Nambu, Kenichi*; et al.

Proceedings of 15th International Conference on Nuclear Engineering (ICONE-15) (CD-ROM), 6 Pages, 2007/04

no abstracts in English

Journal Articles

Innovative alpha radioactivity monitor for clearance level inspection based on ionized air transport technology, 2; CFD-simulated and experimental ion transport efficiencies for uranium-attached pipes

Hirata, Yosuke*; Nakahara, Katsuhiko*; Sano, Akira*; Sato, Mitsuyoshi*; Aoyama, Yoshio; Miyamoto, Yasuaki; Yamaguchi, Hiromi; Nambu, Kenichi*; Takahashi, Hiroyuki*; Oda, Akinori*

Proceedings of 15th International Conference on Nuclear Engineering (ICONE-15) (CD-ROM), 6 Pages, 2007/04

no abstracts in English

Journal Articles

Overview of national centralized tokamak program; Mission, design and strategy to contribute ITER and DEMO

Ninomiya, Hiromasa; Akiba, Masato; Fujii, Tsuneyuki; Fujita, Takaaki; Fujiwara, Masami*; Hamamatsu, Kiyotaka; Hayashi, Nobuhiko; Hosogane, Nobuyuki; Ikeda, Yoshitaka; Inoue, Nobuyuki; et al.

Journal of the Korean Physical Society, 49, p.S428 - S432, 2006/12

To contribute DEMO and ITER, the design to modify the present JT-60U into superconducting coil machine, named National Centralized Tokamak (NCT), is being progressed under nationwide collaborations in Japan. Mission, design and strategy of this NCT program is summarized.

99 (Records 1-20 displayed on this page)