Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Hasemi, Hiroyuki; Takahashi, Ryuta*; Yamauchi, Yasuhiro*; Ishikado, Motoyuki*; Kawamura, Seiko; Komine, Ryota
JPS Conference Proceedings (Internet), 41, p.011003_1 - 011003_5, 2024/03
Yamamoto, Takeshi; Fujita, Manami; Gogami, Toshiyuki*; Harada, Takeshi*; Hayakawa, Shuhei*; Hosomi, Kenji; Ichikawa, Yudai; Ishikawa, Yuji*; Kamata, K.*; Kanauchi, H.*; et al.
EPJ Web of Conferences, 271, p.03001_1 - 03001_5, 2022/11
Takahashi, Masa
NL Dayori, (537), p.2 - 3, 2022/09
no abstracts in English
Takahashi, Masa
NL Dayori, (536), p.2 - 3, 2022/08
no abstracts in English
Takahashi, Tomoyuki*; Fukaya, Yukiko*; Iimoto, Takeshi*; Uni, Yasuo*; Kato, Tomoko; Sun, S.*; Takeda, Seiji; Nakai, Kunihiro*; Nakabayashi, Ryo*; Uchida, Shigeo*; et al.
Hoken Butsuri (Internet), 56(4), p.288 - 305, 2021/12
We report the results of activities related to the Task Group of Parameters Used in Biospheric Dose Assessment Models for Radioactive Waste Disposal at the Japan Health Physics Society.
Takahashi, Masa; Yoshizawa, Michio
Isotope News, (778), p.30 - 33, 2021/12
no abstracts in English
Hashimoto, Makoto; Kinase, Sakae; Munakata, Masahiro; Murayama, Takashi; Takahashi, Masa; Takada, Chie; Okamoto, Akiko; Hayakawa, Tsuyoshi; Sukegawa, Masato; Kume, Nobuhide*; et al.
JAEA-Review 2020-071, 53 Pages, 2021/03
In the case of a nuclear accident or a radiological emergency, the Japan Atomic Energy Agency (JAEA), as a designated public corporation assigned in the Disaster Countermeasures Basic Act and the Armed Attack Situation Response Law, undertakes technical supports to the national government and local governments. The JAEA is requested to support to evaluate radiation doses to residents in a nuclear emergency, which is specified in the Basic Disaster Management Plan and the Nuclear Emergency Response Manual. For the dose evaluation, however, its strategy, target, method, structure and so on have not been determined either specifically or in detail. This report describes the results of investigation and consideration discussed in the "Working Group for Radiation Dose Evaluation at a Nuclear Emergency" established within the Nuclear Emergency Assistance and Training Center to discuss technical supports for radiation dose evaluation to residents in the case of a nuclear emergency, and aims at contributing to specific and detailed discussion and activities in the future for the national government and local governments, also within the JAEA.
Takahashi, Tomoyuki*; Uchida, Shigeo*; Takeda, Seiji; Nakai, Kunihiro*
KURNS-EKR-11, p.97 - 102, 2021/03
This paper outlines the status of IAEA database compilation for migration parameters depending elements in a biosphere such as soil-to-plant transfer factor and bioconcentration factor of marine products, and the status of utilization of the database in dose evaluation of radioactive waste disposal in Japan. Additionally, in the case of applying a new database to the dose evaluation for future radioactive waste disposal in a specific area. We summarized the opinions of specialists and result of general discussion about future strategies to make a new database for their parameters, perspectives to be considered in it, issues, etc.
Tanimura, Yoshihiko; Yoshitomi, Hiroshi; Nishino, Sho; Takahashi, Masa
Radiation Measurements, 137, p.106389_1 - 106389_5, 2020/09
Times Cited Count:0 Percentile:0.01(Nuclear Science & Technology)A portable thyroid dose monitoring system has been developed at the Japan Atomic Energy Agency (JAEA) to assess the thyroid equivalent dose for workers and members of the public in a high dose rate environment. The background (B.G.) photon correction is required for an accurate measurement in a high dose rate environment at an early stage after a nuclear accident. We developed the B.G. photon correction method using cylindrical PMMA phantoms.
Nishino, Sho; Tanimura, Yoshihiko; Yoshitomi, Hiroshi; Takahashi, Masa
Radiation Measurements, 134, p.106292_1 - 106292_5, 2020/06
Times Cited Count:4 Percentile:45.45(Nuclear Science & Technology)In the situation of a severe nuclear accident, radioiodine monitoring in thyroid should be performed for a large number of people immediately after accident. The portable thyroid dose monitoring system which can be used in a high dose rate condition is in development. In this presentation, the result of performance test using prototype model will be described.
Yoshitomi, Hiroshi; Nishino, Sho; Tanimura, Yoshihiko; Takahashi, Masa
Radiation Measurements, 133, p.106279_1 - 106279_6, 2020/04
Times Cited Count:5 Percentile:53.85(Nuclear Science & Technology)Uncertainty of the body size on the counting efficiency of a newly developed thyroid monitor was estimated by Monte Carlo simulations using several voxel phantoms. Overlying tissue thickness was a major impact factor on the counting efficiency. As a result, uncertainty related to the body size of the monitored subject was found to be 25%.
Kawamura, Seiko; Takahashi, Ryuta*; Ishikado, Motoyuki*; Yamauchi, Yasuhiro*; Nakamura, Masatoshi*; Ouchi, Keiichi*; Kira, Hiroshi*; Kambara, Wataru*; Aoyama, Kazuhiro*; Sakaguchi, Yoshifumi*; et al.
Journal of Neutron Research, 21(1-2), p.17 - 22, 2019/05
The Cryogenics and Magnets group in the Sample Environment team is responsible for operation of cryostats and magnets for user's experiments at the MLF in J-PARC. We have introduced a top-loading He cryostat, a bottom-loading He cryostat, a dilution refrigerator insert and a superconducting magnet. The frequency of use of them dramatically becomes higher in these two years, as the beam power and the number of proposal increase. To respond such situation, we have made efforts to enhance performance of these equipment as follows. The He cryostat originally involves an operation software for automatic initial cooling down to the base temperature and automatic re-charge of He. Recently we made an additional program for automatic temperature control with only the sorb heater. Last year, a new outer vacuum chamber of the magnet with an oscillating radial collimator (ORC) was fabricated. The data quality was drastically improved by introducing this ORC so that the magnet can be used even for the inelastic neutron scattering experiments.
Watanabe, Masao; Nojiri, Hiroyuki*; Ito, Shinichi*; Kawamura, Seiko; Kihara, Takumi*; Masuda, Takatsugu*; Sahara, Takuro*; Soda, Minoru*; Takahashi, Ryuta
JPS Conference Proceedings (Internet), 25, p.011024_1 - 011024_5, 2019/03
Recently, neutron scattering experiments have been rapidly progressed under high magnetic field. In the J-PARC, proto-type compact pulse magnet system with the power supply, the coil and the sample stick has been developed. Basic specifications of the power supply are as follows; maximum charged voltage with capacitor is 2 kV, maximum current is 8 kA, repetition rate is a pulse per several minutes and pulse duration is several msec. Maximum magnetic field in the coil is more than 30 Tesla. The sample stick is designed for Orange-Cryostat. In this presentation, We report the details of the pulsed magnet system and the performance of it on neutron scattering experiments at MLF beam line (HRC).
Kajimoto, Ryoichi; Ishikado, Motoyuki*; Kira, Hiroshi*; Kaneko, Koji; Nakamura, Mitsutaka; Kamazawa, Kazuya*; Inamura, Yasuhiro; Ikeuchi, Kazuhiko*; Iida, Kazuki*; Murai, Naoki; et al.
Physica B; Condensed Matter, 556, p.26 - 30, 2019/03
Times Cited Count:2 Percentile:10.61(Physics, Condensed Matter)Tomiyasu, Keisuke*; Ito, Naoko*; Okazaki, Ryuji*; Takahashi, Yuki*; Onodera, Mitsugi*; Iwasa, Kazuaki*; Nojima, Tsutomu*; Aoyama, Takuya*; Ogushi, Kenya*; Ishikawa, Yoshihisa*; et al.
Advanced Quantum Technologies (Internet), 1(3), p.1800057_1 - 1800057_7, 2018/12
Spin-state transition, also known as spin crossover, plays a key role in diverse systems. In theory, the boundary range between the low- and high-spin states is expected to enrich the transition and give rise to unusual physical states. However, no compound that realizes a nearly degenerate critical range as the ground state without requiring special external conditions has yet been experimentally identified. This study reports that the Sc substitution in LaCoO3 destabilizes its nonmagnetic low-spin state and generates an anomalous paramagnetic state accompanied by the enhancement of transport gap and magneto-lattice-expansion as well as the contraction of Co-O distance with the increase of electron site transfer. These phenomena are not well described by the mixture of conventional low- and high-spin states, but by their quantum superposition occurring on the verge of a spin-state transition.
Kawakita, Yukinobu; Kikuchi, Tatsuya*; Inamura, Yasuhiro; Tahara, Shuta*; Maruyama, Kenji*; Hanashima, Takayasu*; Nakamura, Mitsutaka; Kiyanagi, Ryoji; Yamauchi, Yasuhiro*; Chiba, Kaori*; et al.
Physica B; Condensed Matter, 551, p.291 - 296, 2018/12
Times Cited Count:11 Percentile:48.06(Physics, Condensed Matter)There are elemental liquid metals with complex structures far from the hard sphere (HS) packing model. Liquid Bi has an asymmetric first peak in the structure factors S(Q). The pair distribution function g(r) exhibits strange distance ratio of 1:2 between the first and the second peaks. Since a HS model with two kinds of radius produces asymmetry of the main peak in S(Q), existence of short-lived covalent bonds was discussed. Contrarily, modulation of the atomic distribution by the Friedel oscillations of shielding electrons around metallic ions was discussed. To examine its bonding nature from viewpoints of dynamic correlation functions, we have measured neutron quasielastic scattering of liquid Bi by using cold disk chopper spectrometer installed at MLF of J-PARC. The van Hove function revealed that the shoulder structure located at a longer side of the first peak in g(r) exhibits a longer relaxation time than the main structures such as the first and second peaks.
Kajimoto, Ryoichi; Nakamura, Mitsutaka; Inamura, Yasuhiro; Kamazawa, Kazuya*; Ikeuchi, Kazuhiko*; Iida, Kazuki*; Ishikado, Motoyuki*; Murai, Naoki; Kira, Hiroshi*; Nakatani, Takeshi; et al.
Journal of Physics; Conference Series, 1021(1), p.012030_1 - 012030_6, 2018/06
Times Cited Count:3 Percentile:88.67(Nuclear Science & Technology)Kawamura, Seiko; Oku, Takayuki; Watanabe, Masao; Takahashi, Ryuta; Munakata, Koji*; Takata, Shinichi; Sakaguchi, Yoshifumi*; Ishikado, Motoyuki*; Ouchi, Keiichi*; Hattori, Takanori; et al.
Journal of Neutron Research, 19(1-2), p.15 - 22, 2017/11
Sample environment (SE) team at the Materials and Life Science Experimental Facility (MLF) in J-PARC has worked on development and operation of SE equipment and devices. All the members belong to one sub-team at least, such as Cryogenic and magnet, High temperature, High pressure, Soft matter and special environment including Pulse magnet, Hydrogen environment, Light irradiation and He spin filter. Cryostats, a magnet, furnaces, a VX-6-type Paris-Edinburgh press and a prototype of a Spin-Exchange Optical Pumping (SEOP) based He spin filter for polarized neutron beam experiments are in operation. Furthermore, a prototype of compact power supply for a pulsed magnet system is currently developed. In the J-PARC Research Building, several pieces of equipment for softmatter research such as a rheometer and a gas and vapor adsorption measurement instrument have been prepared.
Takahashi, Naoki; Suzuki, Soju; Saito, Hiroto; Ueno, Takashi; Abe, Sadayoshi; Yamanaka, Atsushi; Tanigawa, Masafumi; Nakamura, Daishi; Sasaki, Shunichi; Mine, Tadaharu
Nihon Genshiryoku Gakkai Homu Peji (Internet), 20 Pages, 2017/05
no abstracts in English
Kobayashi, Nobukiyo*; Masumoto, Hiroshi*; Takahashi, Saburo*; Maekawa, Sadamichi
Scientific Reports (Internet), 6, p.34227_1 - 34227_7, 2016/09
Times Cited Count:31 Percentile:75.78(Multidisciplinary Sciences)