Journal Articles

Present status of beryllide R&D as neutron multiplier

Kawamura, Hiroshi; Takahashi, Heishichiro*; Yoshida, Naoaki*; Mishima, Yoshinao*; Ishida, Kiyohito*; Iwadachi, Takaharu*; Cardella, A.*; Van der Laan, J. G.*; Uchida, Munenori*; Munakata, Kenzo*; et al.

Journal of Nuclear Materials, 329-333(1), p.112 - 118, 2004/08

 Times Cited Count:32 Percentile:87.62(Materials Science, Multidisciplinary)

no abstracts in English

Journal Articles

Progress on design and R&D of ITER FW/blanket

Ioki, Kimihiro*; Akiba, Masato; Cardella, A.*; Daenner, W.*; Elio, F.*; Enoeda, Mikio; Lorenzetto, P.*; Miki, Nobuharu*; Osaki, Toshio*; Rozov, V.*; et al.

Fusion Engineering and Design, 61-62, p.399 - 405, 2002/11

 Times Cited Count:11 Percentile:58.2(Nuclear Science & Technology)

We report progress on the ITER-FEAT Blanket design and R&D during 2001-2002. Four major sub-components (FW, shield body, flexible support and electrical connection) have been highlighted. Regarding the FW, design on a separate FW panel concept has progressed, and heat load tests on a small-scale mock-up have been successfully performed with 0.7 MW/m$$^{2}$$, 13000 cycles. Full-scale separate FW panels (dimensions: 0.9$$times$$0.25$$times$$0.07 m) have been fabricated by HIPing and brazing. Regarding the shield body, a radial flow cooling design has been developed, and full-scale partial mock-ups have been fabricated by using water-jet cutting. A separate FW panel was assembled with one the shield body mock-ups. Regarding the flexible support, mill-annealed Ti (easier fabricability) alloy has been selected, and the remote assembly has been considered in the design. In mechanical tests, the requires buckling strength and mechanical fatigue characteristics have been confirmed. Regarding the electrical connection, one-body structure design without welding joints has been developed. Mechanical fatigue tests in the 3 directions, have been carried out, and thermal fatigue tests and electrical tests in a solenoidal magnetic field have been performed. Feasibility of the design has been confirmed. Through progress on design and R&D of the blanket, cost reduction has been achieved, and feasibility of design and fabricability of the components have been confirmed.

Journal Articles

Characteristic evaluation of HIP bonded SS/DSCu joints for surface roughness

Sato, Satoshi; Enoeda, Mikio; Kuroda, Toshimasa*; Ohara, Yoshihiro; Mori, Kensuke*; Cardella, A.*

Fusion Engineering and Design, 58-59(1-4), p.749 - 754, 2001/11

 Times Cited Count:4 Percentile:33.42(Nuclear Science & Technology)

no abstracts in English