Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 50

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Temporally decoherent and spatially coherent vibrations in metal halide perovskites

Zhang, D.*; Hu, X.*; Chen, T.*; Abernathy, D. L.*; Kajimoto, Ryoichi; Nakamura, Mitsutaka; Kofu, Maiko; Foley, B. J.*; Yoon, M.*; Choi, J. J.*; et al.

Physical Review B, 102(22), p.224310_1 - 224310_10, 2020/12

 Times Cited Count:4 Percentile:27.19(Materials Science, Multidisciplinary)

Journal Articles

Stacking fault energy analyses of additively manufactured stainless steel 316L and CrCoNi medium entropy alloy using in situ neutron diffraction

Woo, W.*; Jeong, J.-S.*; Kim, D.-K.*; Lee, C. M.*; Choi, S.-H.*; Suh, J.-Y.*; Lee, S. Y.*; Harjo, S.; Kawasaki, Takuro

Scientific Reports (Internet), 10(1), p.1350_1 - 1350_15, 2020/01

 Times Cited Count:54 Percentile:94.55(Multidisciplinary Sciences)

Journal Articles

PARaDIM; A PHITS-based Monte Carlo tool for internal dosimetry with tetrahedral mesh computational phantoms

Carter, L. M.*; Crawford, T. M.*; Sato, Tatsuhiko; Furuta, Takuya; Choi, C.*; Kim, C. H.*; Brown, J. L.*; Bolch, W. E.*; Zanzonico, P. B.*; Lewis, J. S.*

Journal of Nuclear Medicine, 60(12), p.1802 - 1811, 2019/12

 Times Cited Count:18 Percentile:80.86(Radiology, Nuclear Medicine & Medical Imaging)

Voxel human phantoms have been used for internal dose assessment. More anatomically accurate representation become possible for skins or layer tissues owing to recent developments of advanced polygonal mesh-type phantoms and thus internal dose assessment using those advanced phantoms are desired. However, the Monte Carlo transport calculation by implementing those phantoms require an advanced knowledge for the Monte Carlo transport codes and it is only limited to experts. We therefore developed a tool, PARaDIM, which enables users to conduct internal dose calculation with PHITS easily by themselves. With this tool, a user can select tetrahedral-mesh phantoms, set radionuclides in organs, and execute radiation transport calculation with PHITS. Several test cases of internal dosimetry calculations were presented and usefulness of this tool was demonstrated.

Journal Articles

Beam commissioning of muon beamline using negative hydrogen ions generated by ultraviolet light

Nakazawa, Yuga*; Bae, S.*; Choi, H.*; Choi, S.*; Iijima, Toru*; Iinuma, Hiromi*; Kawamura, Naritoshi*; Kitamura, Ryo; Kim, B.*; Ko, H. S.*; et al.

Nuclear Instruments and Methods in Physics Research A, 937, p.164 - 167, 2019/09

 Times Cited Count:2 Percentile:23.44(Instruments & Instrumentation)

A muon linac is under development for the precise measurement of the muon anomalous magnetic moment ($$g$$-2) and electric dipole moment (EDM) with a reaccelerated thermal muon beam. An H$$^-$$ source driven by an ultraviolet light has been developed for the muon acceleration experiment. Prior to the acceleration experiment, a beamline commissioning was performed using this H$$^-$$ beam, since the accelerated muon intensity is very low. We successfully measured the magnetic rigidity, which is essential for identifying the accelerated muons. This H$$^-$$ source is capable of utilizing as a general-purpose beam source for other beamline.

Journal Articles

Computation speeds and memory requirements of mesh-type ICRP reference computational phantoms in Geant4, MCNP6, and PHITS

Yeom, Y. S.*; Han, M. C.*; Choi, C.*; Han, H.*; Shin, B.*; Furuta, Takuya; Kim, C. H.*

Health Physics, 116(5), p.664 - 676, 2019/05

 Times Cited Count:7 Percentile:62.49(Environmental Sciences)

Recently, Task Group 103 of the ICRP developed the mesh-type reference computational phantoms (MCRPs), which are planned for use in future ICRP dose coefficient calculation. Performance of major Monte Carlo particle transport codes (Geant4, MCNP6, and PHITS) were tested with MCRP. External and internal exposure of various particles and energies were calculated and the computational times and required memories were compared. Additionally calculation for voxel-mesh phantom was also conducted so that the influence of different mesh-representation in each code was studied. Memory usage of MRCP was as large as 10 GB with Geant4 and MCNP6 while it is much less with PHITS (1.2 GB). In addition, the computational time required for MRCP tends to increase compared to voxel-mesh phantoms with Geant4 and MCNP6 while it is equal or tends to decrease with PHITS.

Journal Articles

Passive sweat collection and colorimetric analysis of biomarkers relevant to kidney disorders using a soft microfluidic system

Zhang, Y.*; Guo, H.*; Kim, S. B.*; Wu, Y.*; Ostojich, D.*; Park, S. H.*; Wang, X.*; Weng, Z.*; Li, R.*; Bandodkar, A. J.*; et al.

Lab on a Chip, 19(9), p.1545 - 1555, 2019/05

 Times Cited Count:119 Percentile:99.63(Biochemical Research Methods)

This paper introduces two important advances in recently reported classes of soft, skin-interfaced microfluidic systems for sweat capture and analysis: (1) a simple, broadly applicable means for collection of sweat that bypasses requirements for physical/mental exertion or pharmacological stimulation and (2) a set of enzymatic chemistries and colorimetric readout approaches for determining the concentrations of creatinine and urea in sweat, across physiologically relevant ranges. The results allow for routine, non-pharmacological capture of sweat across patient populations, such as infants and the elderly, that cannot be expected to sweat through exercise, and they create potential opportunities in the use of sweat for kidney disease screening/monitoring.

Journal Articles

$$^{239}$$Pu nuclear magnetic resonance in the candidate topological insulator PuB$$_4$$

Dioguardi, A. P.*; Yasuoka, Hiroshi*; Thomas, S. M.*; Sakai, Hironori; Cary, S. K.*; Kozimor, S. A.*; Albrecht-Schmitt, T. E.*; Choi, H. C.*; Zhu, J.-X.*; Thompson, J. D.*; et al.

Physical Review B, 99(3), p.035104_1 - 035104_6, 2019/01

 Times Cited Count:5 Percentile:38.09(Materials Science, Multidisciplinary)

We present a detailed nuclear magnetic resonance (NMR) study of $$^{239}$$Pu in bulk and powdered single-crystal plutonium tetraboride (PuB$$_4$$), which has recently been investigated as a potential correlated topological insulator. The $$^{239}$$Pu NMR spectra are consistent with axial symmetry of the shift tensor showing for the first time that $$^{239}$$Pu NMR can be observed in an anisotropic environment and up to room temperature. The temperature dependence of the $$^{239}$$Pu shift, combined with a relatively long spin-lattice relaxation time ($$T_1$$), indicate that PuB$$_4$$ adopts a nonmagnetic state with gaplike behavior consistent with our density functional theory calculations. The temperature dependencies of the NMR Knight shift and $$T^{-1}$$ imply bulk gaplike behavior confirming that PuB$$_4$$ is a good candidate topological insulator.

Journal Articles

Battery-free, skin-interfaced microfluidic/electronic systems for simultaneous electrochemical, colorimetric, and volumetric analysis of sweat

Bandodkar, A. J.*; Gutruf, P.*; Choi, J.*; Lee, K.-H.*; Sekine, Yurina; Reeder, J. T.*; Jeang, W. J.*; Aranyosi, A. J.*; Lee, S. P.*; Model, J. B.*; et al.

Science Advances (Internet), 5(1), p.eaav3294_1 - eaav3294_15, 2019/01

 Times Cited Count:386 Percentile:99.88(Multidisciplinary Sciences)

Interest in advanced wearable technologies increasingly extends beyond systems for biophysical measurements to those that enable continuous, non-invasive monitoring of biochemical markers in biofluids. Here, we introduce battery-free, wireless microelectronic platforms that perform sensing via schemes inspired by the operation of biofuel cells. Combining these systems in a magnetically releasable manner with chrono-sampling microfluidic networks that incorporate assays based on colorimetric sensing yields thin, flexible, lightweight, skin-interfaced technologies with broad functionality in sweat analysis. A demonstration device allows simultaneous monitoring of sweat rate/loss, along with quantitative measurements of pH and of lactate, glucose and chloride concentrations using biofuel cell and colorimetric approaches.

Journal Articles

Soft, skin-interfaced microfluidic systems with wireless, battery-free electronics for digital, real-time tracking of sweat loss and electrolyte composition

Kim, S. B.*; Lee, K.-H.*; Raj, M. S.*; Reeder, J. T.*; Koo, J.*; Hourlier-Fargette, A.*; Bandodkar, A. J.*; Won, S. M.*; Sekine, Yurina; Choi, J.*; et al.

Small, 14(45), p.1802876_1 - 1802876_9, 2018/11

 Times Cited Count:74 Percentile:94.04(Chemistry, Multidisciplinary)

Excretion of sweat from eccrine glands is a dynamic physiological process that varies with body position, activity level, and health status. Information content embodied in sweat rate and chemistry can be used to assess health status and athletic performance. This paper presents a thin, miniaturized, skin-interfaced microfluidic technology that includes a reusable, battery-free electronics module for measuring sweat conductivity and rate in real-time using wireless power from and data communication with capabilities in near field communications (NFC). Systematic studies of these combined microfluidic/electronic systems, accurate correlations of measurements performed with them to those of laboratory standard instrumentation, and field tests on human subjects establish the key operational features and their utility in sweat analytics.

Journal Articles

Muon profile measurement after acceleration with a radio-frequency quadrupole linac

Otani, Masashi*; Sue, Yuki*; Fukao, Yoshinori*; Futatsukawa, Kenta*; Kawamura, Naritoshi*; Mibe, Tsutomu*; Miyake, Yasuhiro*; Shimomura, Koichiro*; Yamazaki, Takayuki*; Iijima, Toru*; et al.

Journal of Physics; Conference Series, 1067(5), p.052012_1 - 052012_7, 2018/09

 Times Cited Count:1 Percentile:47.41

We have measured the muon beam profile after acceleration using a radio frequency quadrupole linac (RFQ). Positive muons are injected to an aluminum degrader and negative muoniums (Mu$$^{-}$$) are generated. The generated Mu$$^{-}$$s are extracted by an electrostatic lens and accelerated to 89 keV by the RFQ. The accelerated Mu$$^{-}$$s are transported to a beam profile monitor (BPM) through a quadrupole magnet pair and a bending magnet. The BPM consists of a micro-channel plate, a phospher screen, and a CCD camera. Measured profile in the vertical direction is consistent to the simulation. This profile measurement is one of milestones for realizing a muon linac for measurement of the muon anomalous magnetic moment at the Japan Proton Accelerator Research Complex.

Journal Articles

A Fluorometric skin-interfaced microfluidic device and smartphone imaging module for ${{it in situ}}$ quantitative analysis of sweat chemistry

Sekine, Yurina; Kim, S. B.*; Zhang, Y.*; Bandodkar, A. J.*; Xu, S.*; Choi, J.*; Irie, Masahiro*; Ray, T. R.*; Kohli, P.*; Kozai, Naofumi; et al.

Lab on a Chip, 18(15), p.2178 - 2186, 2018/08

The rich composition of solutes and metabolites in sweat and its relative ease of collection upon excretion from skin pores make this class of biofluid an attractive candidate for point of care analysis. Here, we present a complementary approach that exploits fluorometric sensing modalities integrated into a soft, skin-interfaced microfluidic system which, when paired with a simple smartphone-based imaging module, allows for in-situ measurement of important biomarkers in sweat. A network array of microchannels and a collection of microreservoirs pre-filled with fluorescent probes that selectively react with target analytes in sweat (e.g. probes), enable quantitative, rapid analysis. Field studies on human subjects demonstrate the ability to measure the concentrations of chloride, sodium and zinc in sweat, with accuracy that matches that of conventional laboratory techniques.

Journal Articles

Development of a microchannel plate based beam profile monitor for a re-accelerated muon beam

Kim, B.*; Bae, S.*; Choi, H.*; Choi, S.*; Kawamura, Naritoshi*; Kitamura, Ryo*; Ko, H. S.*; Kondo, Yasuhiro; Mibe, Tsutomu*; Otani, Masashi*; et al.

Nuclear Instruments and Methods in Physics Research A, 899, p.22 - 27, 2018/08

 Times Cited Count:6 Percentile:53.26(Instruments & Instrumentation)

A beam profile monitor (BPM) based on a microchannel plate has been developed for muon beams with low transverse momentum for the measurement of the muon anomalous magnetic moment and electric dipole moment at high precision, with capability of diagnosing muon beams of kinetic energy range from a few keV to 4 MeV. The performance of the BPM has been evaluated using a surface muon beam at J-PARC and additionally with an ultraviolet (UV) light source. It has been confirmed that the BPM has a dynamic range from a few to 10$$^4$$ muons per bunch without saturation. The spatial resolution of the BPM has been estimated to be less than 0.30 mm. The positron background from muon decays is an obstacle in muon beam profile monitoring and a partial discrimination of the positrons has been achieved under discrete particle conditions.

Journal Articles

First muon acceleration using a radio-frequency accelerator

Bae, S.*; Choi, H.*; Choi, S.*; Fukao, Yoshinori*; Futatsukawa, Kenta*; Hasegawa, Kazuo; Iijima, Toru*; Iinuma, Hiromi*; Ishida, Katsuhiko*; Kawamura, Naritoshi*; et al.

Physical Review Accelerators and Beams (Internet), 21(5), p.050101_1 - 050101_6, 2018/05

 Times Cited Count:15 Percentile:78.31(Physics, Nuclear)

Muons have been accelerated by using a radio-frequency accelerator for the first time. Negative muonium atoms (Mu$$^{-}$$), which are bound states of positive muons and two electrons, are generated from through the electron capture process in an aluminum degrader. The generated Mu$$^{-}$$'s are initially electrostatically accelerated and injected into a radio-frequency quadrupole linac (RFQ). In the RFQ, the Mu$$^{-}$$'s are accelerated to 89 keV. The accelerated Mu$$^{-}$$'s are identified by momentum measurement and time of flight. This compact muon linac opens the door to various muon accelerator applications including particle physics measurements and the construction of a transmission muon microscope.

Journal Articles

EBR-II passive safety demonstration tests benchmark analyses; Phase 2

Briggs, L.*; Monti, S.*; Hu, W.*; Sui, D.*; Su, G. H.*; Maas, L.*; Vezzoni, B.*; Partha Sarathy, U.*; Del Nevo, A.*; Petruzzi, A.*; et al.

Proceedings of 16th International Topical Meeting on Nuclear Reactor Thermal Hydraulics (NURETH-16) (USB Flash Drive), p.3030 - 3043, 2015/08

The International Atomic Energy Agency Coordinated Research Project, "Benchmark Analyses of an EBR-II Shutdown Heat Removal Test" is in the third year of its four-year term. Nineteen participants representing eleven countries have simulated two of the most severe transients performed during the Shutdown Heat Removal Tests program conducted at Argonne's Experimental Breeder Reactor II. Benchmark specifications were created for these two transients, enabling project participants to develop computer models of the core and primary heat transport system, and simulate both transients. In phase 1 of the project, blind simulations were performed and then evaluated against recorded data. During phase 2, participants have refined their models to address areas where the phase 1 simulations did not predict as well as desired the experimental data. This paper describes the progress that has been made to date in phase 2 in improving on the earlier simulations and presents the direction of planned work for the remainder of the project.

Journal Articles

Projection imaging with directional electron and proton beams emitted from an ultrashort intense laser-driven thin foil target

Nishiuchi, Mamiko; Choi, I. W.*; Daido, Hiroyuki; Nakamura, Tatsufumi*; Pirozhkov, A. S.; Yogo, Akifumi*; Ogura, Koichi; Sagisaka, Akito; Orimo, Satoshi; Daito, Izuru*; et al.

Plasma Physics and Controlled Fusion, 57(2), p.025001_1 - 025001_9, 2015/02

 Times Cited Count:2 Percentile:9.07(Physics, Fluids & Plasmas)

Projection images of a metal mesh produced by directional MeV electron beam together with directional proton beam, emitted simultaneously from a thin foil target irradiated by an ultrashort intense laser. The mesh patterns are projected to each detector by the electron beam and the proton beam originated from tiny virtual sources of $$sim$$ 20 micron meter and $$sim$$10 micron meter diameters, respectively. Based on the observed quality and magnification of the projection images, we estimate sizes and locations of the virtual sources for both beams and characterize their directionalities. To carry out physical interpretation of the directional electron beam qualitatively, we perform 2D particle-in-cell simulation which reproduces a directional escaping electron component, together with a non-directional dragged-back electron component, the latter mainly contributes to building a sheath electric field for proton acceleration.

Journal Articles

Atomic and electronic structures of Si(111)-$$sqrt{21}timessqrt{21}$$ superstructure

Fukaya, Yuki; Kubo, Keisuke*; Hirahara, Toru*; Yamazaki, Shiro*; Choi, W. H.*; Yeom, H. W.*; Kawasuso, Atsuo; Hasegawa, Shuji*; Matsuda, Iwao*

e-Journal of Surface Science and Nanotechnology (Internet), 10, p.310 - 314, 2012/07

no abstracts in English

Journal Articles

Atomic structure of two-dimensional binary surface alloys; Si(111)-$$sqrt{21}timessqrt{21}$$ superstructure

Fukaya, Yuki; Matsuda, Iwao*; Hashimoto, Mie*; Kubo, Keisuke*; Hirahara, Toru*; Yamazaki, Shiro*; Choi, W. H.*; Yeom, H. W.*; Hasegawa, Shuji*; Kawasuso, Atsuo; et al.

Surface Science, 606(11-12), p.919 - 923, 2012/06

 Times Cited Count:6 Percentile:28.38(Chemistry, Physical)

no abstracts in English

Journal Articles

Simultaneous generation of ions and high-order harmonics from thin conjugated polymer foil irradiated with ultrahigh contrast laser

Choi, I. W.*; Kim, I. J.*; Pae, K. H.*; Nam, K. H.*; Lee, C.-L.*; Yun, H.*; Kim, H. T.*; Lee, S. K.*; Yu, T. J.*; Sung, J. H.*; et al.

Applied Physics Letters, 99(18), p.181501_1 - 181501_3, 2011/11

 Times Cited Count:16 Percentile:57.76(Physics, Applied)

We report the manufacturing of a thin foil target made of conjugated polymer, and the simultaneous observation of laser accelerated ions and second harmonic radiation, when irradiated with ultrahigh-contrast laser pulse at a maximum intensity of 4$$times$$10$$^{19}$$ W/cm$$^{2}$$. Maximum proton energy of 8 MeV is achieved along the target normal direction. Strong second harmonic with over 6% energy ratio compared to fundamental is emitted along the specular direction. Two-dimensional particle-in-cell simulations confirm the simultaneous generation of protons and high-order harmonics, which demonstrates the feasibility of applications requiring particle and radiation sources at once, effectively using the same laser and target.

Journal Articles

Event structure and double helicity asymmetry in jet production from polarized $$p + p$$ collisions at $$sqrt{s}$$ = 200 GeV

Adare, A.*; Afanasiev, S.*; Aidala, C.*; Ajitanand, N. N.*; Akiba, Y.*; Al-Bataineh, H.*; Alexander, J.*; Aoki, K.*; Aphecetche, L.*; Armendariz, R.*; et al.

Physical Review D, 84(1), p.012006_1 - 012006_18, 2011/07

 Times Cited Count:28 Percentile:72.42(Astronomy & Astrophysics)

We report on the event structure and double helicity asymmetry ($$A_{LL}$$) of jet production in longitudinally polarized $$p + p$$ collisions at $$sqrt{s}$$ = 200 GeV. Photons and charged particles were measured by the PHENIX experiment. Event structure was compared with the results from PYTHIA event generator. The production rate of reconstructed jets is satisfactorily reproduced with the next-to-leading-order perturbative QCD calculation. We measured $$A_{LL}$$ = -0.0014 $$pm$$ 0.0037 at the lowest $$P_T$$ bin and -0.0181 $$pm$$ 0.0282 at the highest $$P_T$$ bin. The measured $$A_{LL}$$ is compared with the predictions that assume various $$Delta G(x)$$ distributions.

JAEA Reports

Theoretical study of rock for estimating long-term behavior; FY2009 (Contract research)

Ichikawa, Yasuaki*; Choi, J. H.*; Tanno, Takeo; Hirano, Toru*; Matsui, Hiroya

JAEA-Research 2011-007, 91 Pages, 2011/06

JAEA-Research-2011-007.pdf:8.75MB

We first surveyed the classical theories of fracture mechanics, and discussed the subcritical crack growth (SCG), which is observed under less load than the fracture toughness Kc. This SCG is a result of coupled mechanical and chemical effect. The SCG for granite was treated on this basis. We performed pressure dissolution experiments using specimens of single crystal quartz, since the dissolution reaction is engaged with a deformation and failure process of polycrystalline rock. The series of experiments were managed by a flow-through type changing temperature, pH and applied stress. Si concentrations we here measured. We first surveyed the theories of pressure solution. Then we proposed a theory of saluting velocity of quart which accounts for the effects of temperature, chemical (pH), solid pressure and pore pressure.

50 (Records 1-20 displayed on this page)