Evaluation of thermal strain induced in components of Nb$$_{3}$$Sn strand during cooling

Suwa, Tomone*; Hemmi, Tsutomu*; Saito, Toru*; Takahashi, Yoshikazu*; Koizumi, Norikiyo*; Luzin, V.*; Suzuki, Hiroshi; Harjo, S.

IEEE Transactions on Applied Superconductivity, 28(3), p.6001104_1 - 6001104_4, 2018/04

 Times Cited Count:1 Percentile:7.67(Engineering, Electrical & Electronic)

Journal Articles

Evaluation of bending strain in Nb$$_{3}$$Sn strands of CIC conductor using neutron diffraction

Hemmi, Tsutomu*; Harjo, S.; Kajitani, Hideki*; Suwa, Tomone*; Saito, Toru*; Aizawa, Kazuya; Osamura, Kozo*; Koizumi, Norikiyo*

IEEE Transactions on Applied Superconductivity, 27(4), p.4200905_1 - 4200905_5, 2017/06

 Times Cited Count:1 Percentile:7.98(Engineering, Electrical & Electronic)

Journal Articles

Development of evaluation procedure for critical current of periodically bent Nb$$_{3}$$Sn strand

Kajitani, Hideki; Ishiyama, Atsushi*; Agatsuma, Ko*; Murakami, Haruyuki; Hemmi, Tsutomu; Koizumi, Norikiyo

Teion Kogaku, 50(12), p.608 - 615, 2015/12

A cable-in-conduit (CIC) conductor using Nb$$_{3}$$Sn strand is applied to an ITER TF coil. The Nb$$_{3}$$Sn strand in the conductor is periodically bent due to electromagnetic force, which causes degradation of performance. This degradation should be evaluated to predict conductor critical current performance. In a past study, a numerical simulation model was developed to evaluate the superconductivity of a periodically bent single strand. However, this model is not suitable for application to strands in the conductor because of the extensive calculation time. The author thus developed a new analytical model with a much shorter calculation time to evaluate the performance of periodically bent strand. This new model uses the classical model concept of a high transverse resistance model (HTRM). The calculated results show good agreement with the test results of a periodically bent Nb$$_{3}$$Sn strand. This indicates that a more practical solution can be achieved when evaluating the performance of periodically bent strands. Thus, the model developed in this study can be applied to evaluate the performance of conductors incorporating many strands.

Journal Articles

Thermal strain in superconducting Nb$$_{3}$$Sn strand at cryogenic temperature

Harjo, S.; Kawasaki, Takuro; Hemmi, Tsutomu; Ito, Takayoshi*; Nakamoto, Tatsushi*; Aizawa, Kazuya

JPS Conference Proceedings (Internet), 8, p.031001_1 - 031001_5, 2015/09

Journal Articles

Accuracy of prediction method of cryogenic tensile strength for austenitic stainless steels in ITER toroidal field coil structure

Sakurai, Takeru; Iguchi, Masahide; Nakahira, Masataka; Saito, Toru*; Morimoto, Masaaki*; Inagaki, Takashi*; Hong, Y.-S.*; Matsui, Kunihiro; Hemmi, Tsutomu; Kajitani, Hideki; et al.

Physics Procedia, 67, p.536 - 542, 2015/07

 Times Cited Count:3 Percentile:73.39

Japan Atomic Energy Agency (JAEA) has developed the tensile strength prediction method at liquid helium temperature (4K) using the quadratic curve as a function of the content of carbon and nitrogen in order to establish the rationalized quality control of the austenitic stainless steel used in the ITER superconducting coil operating at 4K. ITER is under construction aiming to verify technical demonstration of a nuclear fusion generation. Toroidal Field Coil (TFC), one of superconducting system in ITER, have been started procurement of materials in 2012. JAEA is producing materials for actual product which are the forged materials with shape of rectangle, round bar, asymmetry and etc. JAEA has responsibility to procure all ITER TFC Structures. In this process, JAEA obtained many tensile strength of both room temperature and 4K about these structural materials, for example, JJ1: High manganese stainless steel for structure (0.03C-12Cr-12Ni-10Mn-5Mo- 0.24N) and 316LN: High nitrogen containing stainless steel (0.2Nitrogen). Based on these data, accuracy of 4K strength prediction method for actual TFC Structure materials was evaluated and reported in this study.

Journal Articles

Non-destructive examination of jacket sections for ITER central solenoid conductors

Takahashi, Yoshikazu; Suwa, Tomone; Nabara, Yoshihiro; Ozeki, Hidemasa; Hemmi, Tsutomu; Nunoya, Yoshihiko; Isono, Takaaki; Matsui, Kunihiro; Kawano, Katsumi; Oshikiri, Masayuki; et al.

IEEE Transactions on Applied Superconductivity, 25(3), p.4200904_1 - 4200904_4, 2015/06

 Times Cited Count:3 Percentile:20.32(Engineering, Electrical & Electronic)

The Japan Atomic Energy Agency (JAEA) is responsible for procuring all amounts of Central Solenoid (CS) Conductors for ITER, including CS jacket sections. The conductor is cable-in-conduit conductor (CICC) with a central spiral. A total of 576 Nb$$_{3}$$Sn strands and 288 copper strands are cabled around the central spiral. The maximum operating current is 40 kA at magnetic field of 13 T. CS jacket section is circular in square type tube made of JK2LB, which is high manganese stainless steel with boron added. Unit length of jacket sections is 7 m and 6,300 sections will be manufactured and inspected. Outer/inner dimension and weight are 51.3/35.3 mm and around 90 kg, respectively. Eddy Current Test (ECT) and Phased Array Ultrasonic Test (PAUT) were developed for non-destructive examination. The defects on inner and outer surfaces can be detected by ECT. The defects inside jacket section can be detected by PAUT. These technology and the inspected results are reported in this paper.

Journal Articles

Behavior of Nb$$_{3}$$Sn cable assembled with conduit for ITER central solenoid

Nabara, Yoshihiro; Suwa, Tomone; Takahashi, Yoshikazu; Hemmi, Tsutomu; Kajitani, Hideki; Ozeki, Hidemasa; Sakurai, Takeru; Iguchi, Masahide; Nunoya, Yoshihiko; Isono, Takaaki; et al.

IEEE Transactions on Applied Superconductivity, 25(3), p.4200305_1 - 4200305_5, 2015/06

 Times Cited Count:0 Percentile:0(Engineering, Electrical & Electronic)

Journal Articles

Nuclear energy (Technical topic); Development of ITER toroidal field (TF) coil

Hemmi, Tsutomu; Kajitani, Hideki; Takano, Katsutoshi; Matsui, Kunihiro; Koizumi, Norikiyo

Yosetsu Gakkai-Shi, 83(6), p.497 - 502, 2014/09

JAEA, serving as the Japan Domestic Agency (JADA) in the ITER project, is responsible for the procurement of 9 TF coils. In the TF coil, the radial plate (RP) structure is selected to improve electrical and mechanical reliability of the electrical insulation. Since the superconductor is degraded by the bending strain of 0.1% after the reaction heat-treatment, the conductor is inserted into the RP after winding to D-shape and the heat-treatment. To insert the conductor into the RP, the winding and RP groove length must be controlled with accuracy of 0.02% (7 mm on the 1 turn of 34 m). Accordingly, the targets for solving this issue are as follows: (1) Development of manufacturing procedure of the RP; (2) Development of winding head to achieve highly accurate winding; (3) Estimation of the conductor elongation after the heat-treatment. Therefore, JAEA can establish manufacturing plan for the TF coil as a result of the R&D for these targets.

Journal Articles

Optimization of heat treatment of Japanese Nb$$_3$$Sn conductors for toroidal field coils in ITER

Nabara, Yoshihiro; Hemmi, Tsutomu; Kajitani, Hideki; Ozeki, Hidemasa; Suwa, Tomone; Iguchi, Masahide; Nunoya, Yoshihiko; Isono, Takaaki; Matsui, Kunihiro; Koizumi, Norikiyo; et al.

IEEE Transactions on Applied Superconductivity, 24(3), p.6000605_1 - 6000605_5, 2014/06

 Times Cited Count:7 Percentile:39.64(Engineering, Electrical & Electronic)

no abstracts in English

Journal Articles

Investigation of strand bending in the He-inlet during reaction heat treatment for ITER TF Coils

Hemmi, Tsutomu; Matsui, Kunihiro; Kajitani, Hideki; Okuno, Kiyoshi; Koizumi, Norikiyo; Ishimi, Akihiro; Katsuyama, Kozo

IEEE Transactions on Applied Superconductivity, 24(3), p.4802704_1 - 4802704_4, 2014/06

 Times Cited Count:1 Percentile:9.47(Engineering, Electrical & Electronic)

Japan Atomic Energy Agency (JAEA), as Japan Domestic Agency, has responsibility to procure nine ITER Toroidal Field (TF) coils. The TF coil winding consists of a Nb$$_{3}$$Sn Cable-In-Conduit conductor, a pair of joints and a He-inlet. The current capacity of 68 kA is required at the magnetic field of 7 T around the He-inlet region in the TF coil winding. During reaction heat-treatment, the compressive residual strain in Nb$$_{3}$$Sn cable is induced by the difference in the thermal expansion coefficients between the Nb$$_{3}$$Sn cable and stainless steel jacket. The strands bending in the Nb$$_{3}$$Sn cable of the He-inlet is anticipated since there is the compressive residual strain and a gap between the Nb$$_{3}$$Sn cable and the He-inlet to introduce SHE flow. If the strand is bent, the variation of mechanical behaviors, such as the elongation of He-inlet during the reaction heat-treatment and the thermally induced residual strain on the jacket around the He-inlet, are expected. To investigate the strands bending in the Nb$$_{3}$$Sn cable of the He-inlet, the following items are performed; (1) elongation measurement during reaction heat-treatment, (2) residual longitudinal strain measurement using strain gauges by sample cuttings, (3) nondestructive inspection on the cable and strands using high resolution X-ray CT, Detail of test results and investigation of the strands bending in the Nb$$_{3}$$Sn cable of the He-inlet are reported and discussed.

Journal Articles

Cabling technology of Nb$$_3$$Sn conductor for ITER central solenoid

Takahashi, Yoshikazu; Nabara, Yoshihiro; Ozeki, Hidemasa; Hemmi, Tsutomu; Nunoya, Yoshihiko; Isono, Takaaki; Matsui, Kunihiro; Kawano, Katsumi; Oshikiri, Masayuki; Uno, Yasuhiro; et al.

IEEE Transactions on Applied Superconductivity, 24(3), p.4802404_1 - 4802404_4, 2014/06

 Times Cited Count:23 Percentile:73.01(Engineering, Electrical & Electronic)

Japan Atomic Energy Agency (JAEA) is procuring all amounts of Nb$$_3$$Sn conductors for Central Solenoid (CS) in the ITER project. Before start of mass-productions, the conductor should be tested to confirm superconducting performance in the SULTAN facility, Switzerland. The original design of cabling twist pitches is 45-85-145-250-450 mm, called normal twist pitch (NTP). The test results of the conductors with NTP was that current shearing temperature (Tcs) is decreasing due to electro-magnetic (EM) load cycles. On the other hand, the results of the conductors with short twist pitches (STP) of 25-45-80-150-450 mm show that the Tcs is stabilized during EM load cyclic tests. Because the conductors with STP have smaller void fraction, higher compaction ratio during cabling is required and possibility of damage on strands increases. The technology for the cables with STP was developed in Japanese cabling suppliers. The several key technologies will be described in this paper.

Journal Articles

Progress of manufacturing trials for the ITER toroidal field coil structures

Iguchi, Masahide; Morimoto, Masaaki; Chida, Yutaka*; Hemmi, Tsutomu; Nakajima, Hideo; Nakahira, Masataka; Koizumi, Norikiyo; Yamamoto, Akio*; Miyake, Takashi*; Sawa, Naoki*

IEEE Transactions on Applied Superconductivity, 24(3), p.3801004_1 - 3801004_4, 2014/06

 Times Cited Count:6 Percentile:35.78(Engineering, Electrical & Electronic)

no abstracts in English

Journal Articles

Residual strains in ITER conductors by neutron diffraction

Harjo, S.; Hemmi, Tsutomu; Abe, Jun; Gong, W.; Nunoya, Yoshihiko; Aizawa, Kazuya; Ito, Takayoshi*; Koizumi, Norikiyo; Machiya, Shutaro*; Osamura, Kozo*

Materials Science Forum, 777, p.84 - 91, 2014/02

 Times Cited Count:2 Percentile:72.87

Journal Articles

Evaluation of inter-laminar shear strength of GFRP composed of bonded glass/polyimide tapes and cyanate-ester/epoxy blended resin for ITER TF coils

Hemmi, Tsutomu; Nishimura, Arata*; Matsui, Kunihiro; Koizumi, Norikiyo; Nishijima, Shigehiro*; Shikama, Tatsuo*

AIP Conference Proceedings 1574, p.154 - 161, 2014/01

 Times Cited Count:6 Percentile:92.73

Japan Atomic Energy Agency (JAEA), as Japan Domestic Agency, has responsibility to procure 9 ITER Toroidal Field (TF) coils. The insulation system of the ITER TF coils consists of 3 layers of insulations, which are a conductor insulation, a double-pancake (DP) insulation and a ground insulation, composed of multi-layer glass/polyimide tapes impregnated a resin. The ITER TF coils are required to withstand an irradiation of 10 MGy from $$gamma$$-ray and neutrons since the ITER TF coils is exposed by first neutron ($$>$$ 0.1 MeV) of 10$$^{22}$$ n/m$$^{2}$$ during the operation of 20 years in the ITER. Cyanate-ester/epoxy blended resins and bonded glass/polyimide tapes are developed as insulation materials to realize the required radiation-hardness for the insulation of the ITER TF coils. To evaluate the radiation-hardness of the developed insulation materials, the inter-laminar shear strength of glass-fiber reinforced plastics (GFRP) fabricated using developed insulation materials is measured as one of most important mechanical properties before/after the irradiation in a fission reactor of JRR-3. As a result, it is demonstrated that the GFRPs using the developed insulation materials have a sufficient performance to apply the ITER TF coil insulation.

Journal Articles

Investigation of degradation mechanism of ITER CS conductor sample using TAKUMI

Hemmi, Tsutomu; Harjo, S.; Kajitani, Hideki; Nabara, Yoshihiro; Takahashi, Yoshikazu; Nunoya, Yoshihiko; Koizumi, Norikiyo; Abe, Jun; Gong, W.; Aizawa, Kazuya; et al.

KEK Progress Report 2013-4, p.45 - 47, 2013/11

The gradual degradation was observed in the results for ITER CS conductor samples. To investigate its origin, the internal strain in the sample after the testing was successfully measured using a neutron diffraction technique non-destructively. Up to now, the transverse electromagnetic loading has been considered as an origin of the degradation due to the local bending at the high loading side (HLS). However, as a result of the neutron diffraction measurement, the large bending at the LLS of the HFZ was found. The large bending was considered as an origin of the strand buckling due to the large void generated by the transverse electromagnetic loading and the thermally induced residual compressive strain. For the improvement of the conductor performance on the strand buckling, the shorter twisting pitch (STP) can be considered. The result of the SULTAN testing of the conductor sample with STP found very effective, and the performance degradation was negligible.

Journal Articles

Neutron diffraction measurement of internal strain in the first Japanese ITER CS conductor sample

Hemmi, Tsutomu; Harjo, S.; Nunoya, Yoshihiko; Kajitani, Hideki; Koizumi, Norikiyo; Aizawa, Kazuya; Machiya, Shutaro*; Osamura, Kozo*

Superconductor Science and Technology, 26(8), p.084002_1 - 084002_6, 2013/08

 Times Cited Count:14 Percentile:55.58(Physics, Applied)

JAEA has responsibly to procure all ITER CS conductors. Several conductor samples was fabricated and tested. From the result of the cyclic testing in first conductor sample named JACS01 and second conductor sample named JACS02, the continuous linear degradation of the current sharing temperature ($$T$$$$_{cs}$$) was observed. To investigate the $$T$$$$_{cs}$$ degradation, the visual inspection of JACS01 right leg was performed. As a result, the large deflection at the lower loading side (LLS) in the high field zone (HFZ) was observed. The bending strain of the strands cannot be evaluated from the only deflection obtained by a visual inspection. To evaluate the strain of strands in the conductor sample quantitatively, the neutron diffraction measurement of JACS01 left leg was performed using the engineering materials diffractometer in J-PARC. From the result, the large bending strain at the LLS in the HFZ was observed. Therefore, the degraded position in the conductor sample can be determined.

Journal Articles

Cable twist pitch variation in Nb$$_{3}$$Sn conductors for ITER toroidal field coils in Japan

Takahashi, Yoshikazu; Nabara, Yoshihiro; Hemmi, Tsutomu; Nunoya, Yoshihiko; Isono, Takaaki; Hamada, Kazuya; Matsui, Kunihiro; Kawano, Katsumi; Koizumi, Norikiyo; Oshikiri, Masayuki; et al.

IEEE Transactions on Applied Superconductivity, 23(3), p.4801504_1 - 4801504_4, 2013/06

 Times Cited Count:11 Percentile:50.68(Engineering, Electrical & Electronic)

Japan Atomic Energy Agency (JAEA) is the first to start the mass production of the TF conductors in March 2010 among the 6 parties who are procuring TF conductors in the ITER project. The height and width of the TF coils are 14 m and 9 m, respectively. The conductor is cable-in-conduit conductor (CICC) with a central spiral. A circular multistage superconducting cable is inserted into a circular stainless steel jacket with a thickness of 2 mm. A total of 900 Nb$$_{3}$$Sn strands and 522 copper strands are cabled around the central spiral and the cable is inserted into a round-in-round stainless steel jacket. It was observed that the cabling pitch of the destructive sample is longer than the original pitch at cabling. The JAEA carried out the tensile tests of the cable and the measurement of the cable rotation during the insertion to investigate the cause of the elongation. The cause of elongation was clarified and the results will be described in this paper.

Journal Articles

Analytical study of degradation of CIC conductor performance due to strand bending and buckling

Kajitani, Hideki; Hemmi, Tsutomu; Murakami, Haruyuki; Koizumi, Norikiyo

IEEE Transactions on Applied Superconductivity, 23(3), p.6001505_1 - 6001505_5, 2013/06

 Times Cited Count:6 Percentile:35.14(Engineering, Electrical & Electronic)

Critical current of cable-in-conduit conductors (CICCs) for ITER TF coils was measured. It was found from these test results that the measured critical current was lower than that evaluated from the critical current performance of a single strand. One of the explanations for this phenomenon is a non-uniform current distribution due to (1) unbalanced resistance among strands and between the strand and the upper/bottom joint and (2) local degradation of strand in the conductor. It is reported that the former was improved by using solder-filled joint but the latter issue seems to still remain. Therefore, the author developed a new analysis model for the calculation of strain distribution in the conductor taking account of strand bending and buckling and then, combined this with the electrical circuit model developed by authors before. Simulation results show that when local degradation is significant, the conductor performance can be degraded. In this presentation, these results are reported.

Journal Articles

Examination of Nb$$_{3}$$Sn conductors for ITER central solenoids

Nabara, Yoshihiro; Hemmi, Tsutomu; Kajitani, Hideki; Ozeki, Hidemasa; Iguchi, Masahide; Nunoya, Yoshihiko; Isono, Takaaki; Takahashi, Yoshikazu; Matsui, Kunihiro; Koizumi, Norikiyo; et al.

IEEE Transactions on Applied Superconductivity, 23(3), p.4801604_1 - 4801604_4, 2013/06

 Times Cited Count:10 Percentile:48.09(Engineering, Electrical & Electronic)

no abstracts in English

Journal Articles

ITER magnet systems; From qualification to full scale construction

Nakajima, Hideo; Hemmi, Tsutomu; Iguchi, Masahide; Nabara, Yoshihiro; Matsui, Kunihiro; Chida, Yutaka; Kajitani, Hideki; Takano, Katsutoshi; Isono, Takaaki; Koizumi, Norikiyo; et al.

Proceedings of 24th IAEA Fusion Energy Conference (FEC 2012) (CD-ROM), 8 Pages, 2013/03

The ITER organization and 6 Domestic Agencies (DA) have been implementing the construction of ITER superconducting magnet systems. Four DAs have already started full scale construction of Toroidal Field (TF) coil conductors. The qualification of the radial plate manufacture has been completed, and JA and EU are ready for full scale construction. JA has qualified full manufacturing processes of the winding pack with a 1/3 prototype and made 2 full scale mock-ups of the basic segments of TF coil structure to optimize and industrialize the manufacturing process. Preparation and qualification of the full scale construction of the TF coil winding is underway by EU. Procurement of the manufacturing equipment is near completion and qualification of manufacturing processes has already started. The constructions of other components of the ITER magnet systems are also going well towards the main goal of the first plasma in 2020.