Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 39

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Current status of electrostatic accelerator at TIARA

Usui, Aya; Chiba, Atsuya; Yamada, Keisuke; Yokoyama, Akihito; Kitano, Toshihiko*; Takayama, Terumitsu*; Orimo, Takao*; Kanai, Shinji*; Aoki, Yuki*; Hashizume, Masashi*; et al.

Dai-28-Kai Tandemu Kasokuki Oyobi Sono Shuhen Gijutsu No Kenkyukai Hokokushu, p.117 - 119, 2015/12

no abstracts in English

Journal Articles

Current status of electrostatic accelerators at TIARA

Usui, Aya; Uno, Sadanori; Chiba, Atsuya; Yamada, Keisuke; Yokoyama, Akihito; Kitano, Toshihiko*; Takayama, Terumitsu*; Orimo, Takao*; Kanai, Shinji*; Aoki, Yuki*; et al.

Dai-27-Kai Tandemu Kasokuki Oyobi Sono Shuhen Gijutsu No Kenkyukai Hokokushu, p.118 - 121, 2015/03

no abstracts in English

Journal Articles

Operation of electrostatic accelerators

Uno, Sadanori; Chiba, Atsuya; Yamada, Keisuke; Yokoyama, Akihito; Usui, Aya; Saito, Yuichi; Ishii, Yasuyuki; Sato, Takahiro; Okubo, Takeru; Nara, Takayuki; et al.

JAEA-Review 2013-059, JAEA Takasaki Annual Report 2012, P. 179, 2014/03

Three electrostatic accelerators at TIARA were operated on schedule in fiscal year 2012 except changing its schedule by cancellations of users. The yearly operation time of the 3 MV tandem accelerator, the 400 kV ion implanter and the 3MV single-ended accelerator were in the same levels as the ordinary one, whose operation time totaled to 2,073, 1,847 and 2,389 hours, respectively. The tandem accelerator had no trouble, whereas the ion implanter and the single-ended accelerator stopped by any troubles for one day and four days, respectively. The molecular ion beam of helium hydride was generated by the ion implanter, because the users required irradiation of several cluster ions in order to study the effect of irradiation. As a result, its intensity of beam was 50 nA at 200 kV. The ion beam of tungsten (W) at 15 MeV was accelerated by the tandem accelerator, whose intensity was 20 nA at charge state of 4+, because of the request from a researcher in the field of nuclear fusion.

Journal Articles

Current status of electrostatic accelerators at TIARA

Uno, Sadanori; Chiba, Atsuya; Yamada, Keisuke; Yokoyama, Akihito; Usui, Aya; Kitano, Toshihiko*; Takayama, Terumitsu*; Orimo, Takao*; Kanai, Shinji*; Aoki, Yuki*; et al.

Dai-26-Kai Tandemu Kasokuki Oyobi Sono Shuhen Gijutsu No Kenkyukai Hokokushu, p.79 - 81, 2013/07

Three electrostatic accelerators at TIARA were operated on schedule in fiscal year 2012 except changing its schedule by cancellations of users. The yearly operation time of the 3MV tandem accelerator, the 400 kV ion implanter and the 3 MV single-ended accelerator were in the same levels as the ordinary one, whose operation time totaled to 2,073, 1,847 and 2,389 hours, respectively. The tandem accelerator had no trouble, whereas the ion implanter and the single-ended accelerator stopped by any troubles for one day and four days, respectively. The ion implanter generated molecular ion beam of helium hydride by using the Freeman type ion source, because of the request from the user. As a result, its intensity of beam was 50 nA at 200 kV.

Journal Articles

Operation of electrostatic accelerators

Uno, Sadanori; Chiba, Atsuya; Yamada, Keisuke; Yokoyama, Akihito; Saito, Yuichi; Ishii, Yasuyuki; Sato, Takahiro; Okubo, Takeru; Nara, Takayuki; Kitano, Toshihiko*; et al.

JAEA-Review 2012-046, JAEA Takasaki Annual Report 2011, P. 173, 2013/01

The three electrostatic accelerators at the TIARA had no mechanical damage when the Tohoku earthquake happened on March 11, 2011. But, they could not be operated during April, due to the influence of planned power outage by TEPCO. These accelerators additionally operated on Saturday for ten days in order to compensate for the lost experiment time. As a result, the yearly operation time had kept the same level as the ordinary one. The ion beam of erbium (Er) with 11.7MeV was accelerated newly by the tandem accelerator, whose intensity was 20nA at charge state of 3+. The sequential generation/irradiation of two different kinds of fullerene ions was achieved at the ion implanter by a mixed powder method without exchange of the Freeman type ion source by the user's request.

Journal Articles

Operation of electrostatic accelerators at TIARA

Uno, Sadanori; Chiba, Atsuya; Yamada, Keisuke; Yokoyama, Akihito; Saito, Yuichi; Ishii, Yasuyuki; Sato, Takahiro; Okubo, Takeru; Nara, Takayuki; Kitano, Toshihiko*; et al.

Dai-7-Kai Takasaki Oyo Kenkyu Shimpojiumu Yoshishu, P. 119, 2012/10

The three electrostatic accelerators at TIARA had no damage when the Tohoku earthquake happened on March 11, 2011. But, they could not be operated until end of April, due to the influence of planned power outage and keep out into the controlled area for radiation. These accelerators additionally operated on Saturday for twelve days in order to compensate for the lost experiment time. Therefore, the yearly operation time had kept the same level as the ordinary one. The tandem accelerator has stopped leakage of the SF$$_{6}$$ gas from the base flange on the tank by the Viton gasket of rectangular cross section at the new type.

Journal Articles

Effects of particle irradiations on vortex states in iron-based superconductors

Tamegai, Tsuyoshi*; Taen, Toshihiro*; Yagyuda, Hidenori*; Tsuchiya, Yuji*; Mohan, S.*; Taniguchi, Tomotaka*; Nakajima, Yasuyuki*; Okayasu, Satoru; Sasase, Masato*; Kitamura, Hisashi*; et al.

Superconductor Science and Technology, 25(8), p.084008_1 - 084008_14, 2012/08

 Times Cited Count:85 Percentile:93.2(Physics, Applied)

Various kinds of energetic particles are irradiated into iron-based superconductors, and their effects on the critical current density $$J$$$$_{rm c}$$ and vortex dynamics have been systematically studied. It is found that $$J$$$$_{rm c}$$ is enhanced and vortex dynamics is strongly suppressed by energetic particles having a sufficient energy deposition rate, similar to the case of high temperature cuprate superconductors. The enhancement of $$J$$$$_{rm c}$$, in general, persists up to much higher irradiation doses than in cuprates. However, details of the effect of irradiation depend on the kind of ion species and their energies. Even with the same ions and energies, the effect is not universal for different kinds of iron-based superconductors. The correlated nature of defects created by heavy-ion irradiation is confirmed by the angular dependence of irreversible magnetization.

Journal Articles

Current status of electrostatic accelerators at TIARA

Uno, Sadanori; Chiba, Atsuya; Yamada, Keisuke; Yokoyama, Akihito; Kitano, Toshihiko*; Takayama, Terumitsu*; Orimo, Takao*; Kanai, Shinji*; Aoki, Yuki*; Yamada, Naoto*; et al.

Dai-25-Kai Tandemu Kasokuki Oyobi Sono Shuhen Gijutsu No Kenkyukai Hokokushu, p.64 - 66, 2012/07

The three electrostatic accelerators at the TIARA had no damage when the Tohoku earthquake happened on March 11, 2011. But, they could not be operated until end of April, due to the influence of planned power outage and keep out into the controlled area for radiation. These accelerators additionally operated on Saturday for twelve days in order to compensate for the lost experiment time. Therefore, the yearly operation time had kept the same level as the ordinary one. The tandem accelerator has stopped leakage of the SF$$_{6}$$ gas from the base flange on the tank by the Viton gasket of rectangular cross section at the new type. The ion implanter could generate two kinds of fullerene ions by a mixed material of ions and a controlled temperature of the oven without exchange of ion source.

Journal Articles

Operation of the electrostatic accelerators

Agematsu, Takashi; Uno, Sadanori; Chiba, Atsuya; Yamada, Keisuke; Yokoyama, Akihito; Saito, Yuichi; Ishii, Yasuyuki; Sato, Takahiro; Okubo, Takeru; Yokota, Wataru; et al.

JAEA-Review 2011-043, JAEA Takasaki Annual Report 2010, P. 173, 2012/01

Three electrostatic accelerators of TIARA were operated smoothly in FY 2010, and all the planned experiments were carried out except those canceled by users or the impact of Great East Japan Earthquake on March 11, 2011. On the other hand, Saturday operation for experiments was carried out after October on the Global Nuclear-Human Resource Development Initiative. The yearly operation time of the tandem accelerator, the single-ended accelerator and the ion implanter amounted to 2116, 2367 and 1800 hours, respectively, which were similar to those of usual years. Regarding the single-ended accelerator, the generator in the high-voltage terminal failed and was replaced with new one. A switching magnet was installed for a new branch beam line of the ion implanter. As to the tandem accelerator, In ion was generated and accelerated at intensity of 500 nA.

Journal Articles

Current status of electrostatic accelerators at TIARA

Uno, Sadanori; Chiba, Atsuya; Yamada, Keisuke; Yokoyama, Akihito; Agematsu, Takashi; Kitano, Toshihiko*; Takayama, Terumitsu*; Orimo, Takao*; Kanai, Shinji*; Aoki, Yuki*; et al.

Dai-24-Kai Tandemu Kasokuki Oyobi Sono Shuhen Gijutsu No Kenkyukai Hokokushu, p.125 - 128, 2011/07

The yearly operation time of three electrostatic accelerators at TIARA of Japan Atomic Energy Agency is keeping the same level since 2000, the tandem accelerator, the ion implanter and the single-ended accelerator amounted to about 2000, 1900 and 2500 hours, respectively. Three electrostatic accelerators did not have damage when the Tohoku Earthquake occurred on March 11, 2011. However, these accelerators were not able to operate during the planned power outage by Tokyo Electric Power Company (TEPCO). The tandem accelerator accelerated ion beam of In, which gave intensity of 500nA with stability. Additionally, the ion implanter generated maximum 400nA at ion beam of Gd, which was used in experiments for the users.

Journal Articles

Operation of the electrostatic accelerators

Agematsu, Takashi; Uno, Sadanori; Chiba, Atsuya; Yamada, Keisuke; Yokoyama, Akihito; Saito, Yuichi; Ishii, Yasuyuki; Sato, Takahiro; Okubo, Takeru; Yokota, Wataru; et al.

JAEA-Review 2010-065, JAEA Takasaki Annual Report 2009, P. 181, 2011/01

Three electrostatic accelerators of TIARA were operated smoothly in FY 2009, and all the planned experiments were carried out except those canceled by users. The yearly operation time of the tandem accelerator, the single-ended accelerator and the ion implanter amounted to 2100, 2416 and 1866 hours, respectively. Regarding the single-ended accelerator, the radio frequency oscillator of the ion source mounted in high-voltage terminal and the sequencer for control of the SB beam line failed, and they were replaced. The oven controller of Freeman ion source of the ion implanter was renewed. As to the tandem accelerator, Mn ion was successfully generated and accelerated with intensity of 150 nA.

Journal Articles

Low-field anomaly of vortex dynamics in iron-pnictide superconductors

Tamegai, Tsuyoshi*; Taen, Toshihiro*; Yagyuda, Hidenori*; Nakajima, Yasuyuki*; Okayasu, Satoru; Sasase, Masato*; Kitamura, Hisashi*; Murakami, Takeshi*; Kambara, Tadashi*; Kanai, Yasuyuki*

Physica C, 471, p.777 - 780, 2011/00

 Times Cited Count:6 Percentile:29.25(Physics, Applied)

Magnetic relaxations in Ba(Fe$$_{1-x}$$Co$$_{x}$$)$$_{2}$$As$$_{2}$$ before and after swift particle irradiations are measured. The normalized relaxation rate S shows a clear suppression in a pristine sample at low fields below the self-field. Heavy-ion irradiations suppress these anomalies considerably, although there still remain weak features depending on ion species and/or energies. In a proton irradiated sample, the low-field anomaly of S survives although it is smeared compared with that in a pristine sample. All these results indicate that the low-field anomaly of S is suppressed by defects, and correlated defects have stronger effects.

Journal Articles

Current status of electrostatic accelerators at TIARA

Chiba, Atsuya; Uno, Sadanori; Yamada, Keisuke; Yokoyama, Akihito; Agematsu, Takashi; Yokota, Wataru; Kitano, Toshihiko*; Takayama, Terumitsu*; Kanai, Shinji*; Orimo, Takao*; et al.

Dai-23-Kai Tandemu Kasokuki Oyobi Sono Shuhen Gijutsu No Kenkyukai Hokokushu, p.119 - 122, 2010/11

Operation times of each accelerator are keeping the same level as in recent 10 years, Tandem accelerator, Single-ended and Ion implanter amounted to about 2,000, 2,500 and 1,900 hours, respectively. In the last fiscal year, we succeeded in maintaining the terminal voltage of the tandem accelerator to high stability for long periods by exchanging the material of a corona-probe needle to the tungsten (NPS Co.). In the ion-implanter, the oven control system equipped with the Freeman ion source was renewed. There was no trouble to affect on the machine-time in the last fiscal year, so the all planned experiments were carried out.

Journal Articles

Decay properties of $$^{266}$$Bh and $$^{262}$$Db produced in the $$^{248}$$Cm + $$^{23}$$Na reaction

Morita, Kosuke*; Morimoto, Koji*; Kaji, Daiya*; Haba, Hiromitsu*; Ozeki, Kazutaka*; Kudo, Yuki*; Sato, Nozomi*; Sumita, Takayuki*; Yoneda, Akira*; Ichikawa, Takatoshi*; et al.

Journal of the Physical Society of Japan, 78(6), p.064201_1 - 064201_6, 2009/06

 Times Cited Count:30 Percentile:78.34(Physics, Multidisciplinary)

Decay properties of an isotope $$^{266}$$Bh and its daughter nucleus $$^{262}$$Db produced by the $$^{248}$$Cm($$^{23}$$Na,5$$n$$) reaction were studied by using a gas-filled recoil separator coupled with a position-sensitive semiconductor detector. $$^{266}$$Bh was clearly identified from the correlation of the known nuclide, $$^{262}$$Db. The obtained decay properties of $$^{266}$$Bh and $$^{262}$$Db are consistent with those observed in the $$^{278}$$113 chain, which provided further confirmation of the discovery of $$^{278}$$113.

Journal Articles

Status of electrostatic accelerators at TIARA; Status of TANDEM accelerator

Chiba, Atsuya; Ishii, Yasuyuki; Mizuhashi, Kiyoshi; Kitano, Toshihiko*; Kanai, Shinji*; Aoki, Yuki*

JAEA-Conf 2008-005, p.107 - 109, 2008/03

no abstracts in English

Journal Articles

Operation of the electrostatic accelerators

Mizuhashi, Kiyoshi; Uno, Sadanori; Okoshi, Kiyonori; Chiba, Atsuya; Yamada, Keisuke; Saito, Yuichi; Ishii, Yasuyuki; Sato, Takahiro; Sakai, Takuro; Yokota, Wataru; et al.

JAEA-Review 2006-042, JAEA Takasaki Annual Report 2005, P. 197, 2007/02

Three electrostatic accelerators were almost operated smoothly for various experiments in FY 2005. The yearly operation time of each accelerator amounts to 1974, 2359.9, 1859.9 hour for the tandem, the single-ended and the ion implanter, respectively. Main trouble was a short circuit of a part of the ion source in the single-ended accelerator. This lets to the suspension of operation for fifteen days. As features in FY 2005, the generation of the power cut by thunderbolts and large earthquakes were abounding. By this natural force, the Turbo-molecular pump was broken, experiment was interrupted and then the inspection of accelerator facility was carried out every time. New beam acceleration and improvement of each accelerator were carried out.

Journal Articles

Operation of the electrostatic accelerators

Mizuhashi, Kiyoshi; Uno, Sadanori; Okoshi, Kiyonori; Chiba, Atsuya; Yamada, Keisuke; Saito, Yuichi; Ishii, Yasuyuki; Sakai, Takuro; Sato, Takahiro; Yokota, Wataru; et al.

JAEA-Review 2005-001, TIARA Annual Report 2004, P. 371, 2006/01

no abstracts in English

Journal Articles

Angular momentum distributions of Rydberg state electrons of Be-like sulfur produced through foil penetration

Imai, Makoto*; Sataka, Masao; Kitazawa, Shinichi; Komaki, Kenichiro*; Kawatsura, Kiyoshi*; Shibata, Hiromi*; Tawara, Hiroyuki*; Azuma, Toshiyuki*; Kanai, Yasuyuki*; Yamazaki, Y.*

Nuclear Instruments and Methods in Physics Research B, 193(1-4), p.674 - 679, 2002/06

 Times Cited Count:5 Percentile:34.58(Instruments & Instrumentation)

no abstracts in English

Journal Articles

Electron spectroscopy of doubly excited states in He produced by slow collisions of He$$^{2+}$$ ions with Ba atoms

Iemura, K.*; Otani, Shunsuke*; Suzuki, H.*; Takeda, Junichi*; Machida, Shuichi*; Tanabe, K.*; Takayanagi, Toshinobu*; Wakiya, K.*; Sekiguchi, M.*; Kanai, Yasuyuki*; et al.

Physical Review A, 64(6), p.062709_1 - 062709_14, 2001/12

 Times Cited Count:6 Percentile:35.74(Optics)

We measured ejected electron spectra caused by autoionization of doubly excited states in He atoms; the excited He was made by double electron capture of low-energy He$$^{2+}$$ ions colliding with Ba atoms. Measurements were performed by means of zero degree electron spectroscopy at projectile energies from 40 to 20 keV. Electron spectra due to autoionization from the states He(2lnl) to He+(1s) for n$$geq$$2, and those from He(3lnl) to He$$^+$$(2s or 2p) for n$$geq$$3, were observed. Line peaks in the spectra were identified by comparing observed electron spectra with those of several theoretical calculations. It was found that doubly excited states of relatively high angular momenta such as the D and F terms were conspicuously created in a quite different manner from the cases of the production of doubly excited states by the use of photon, electron, or ion impacts on neutral He atoms. Rydberg states with large n values were observed with high population in both the He(2lnl) and He(3lnl) series.

Journal Articles

Electron spectrra from singlet and triplet states of Ne$$^{6+**}$$ produced by low energy Ne$$^{8+}$$+He, Ne and Ar collisions

Kitazawa, Shinichi; Ida, H.*; Matsui, Y.*; Takayanagi, Toshinobu*; Wakiya, K.*; Iemura, K.*; Otani, Shunsuke*; Suzuki, H.*; Kanai, Yasuyuki*; Safronova, U. I.*

Journal of Physics B; Atomic, Molecular and Optical Physics, 34(16), p.3205 - 3220, 2001/08

 Times Cited Count:5 Percentile:31.39(Optics)

no abstracts in English

39 (Records 1-20 displayed on this page)