Refine your search:     
Report No.
 - 
Search Results: Records 1-9 displayed on this page of 9
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Neutron transmission CB-KID imager using samples placed at room temperature

Ishida, Takekazu*; Vu, TheDang*; Shishido, Hiroaki*; Aizawa, Kazuya; Oku, Takayuki; Oikawa, Kenichi; Harada, Masahide; Kojima, Kenji M*; Miyajima, Shigeyuki*; Koyama, Tomio*; et al.

Journal of Low Temperature Physics, 214(3-4), p.152 - 157, 2024/02

 Times Cited Count:0 Percentile:0.02(Physics, Applied)

Journal Articles

Orientation mapping of YbSn$$_{3}$$ single crystals based on Bragg-dip analysis using a delay-line superconducting sensor

Shishido, Hiroaki*; Vu, TheDang*; Aizawa, Kazuya; Kojima, Kenji M*; Koyama, Tomio*; Oikawa, Kenichi; Harada, Masahide; Oku, Takayuki; Soyama, Kazuhiko; Miyajima, Shigeyuki*; et al.

Journal of Applied Crystallography, 56(4), p.1108 - 1113, 2023/08

 Times Cited Count:0 Percentile:0.02(Chemistry, Multidisciplinary)

Journal Articles

High spatial resolution neutron transmission imaging using a superconducting two-dimensional detector

Shishido, Hiroaki*; Nishimura, Kazuma*; Vu, TheDang*; Aizawa, Kazuya; Kojima, Kenji M*; Koyama, Tomio*; Oikawa, Kenichi; Harada, Masahide; Oku, Takayuki; Soyama, Kazuhiko; et al.

IEEE Transactions on Applied Superconductivity, 31(9), p.2400505_1 - 2400505_5, 2021/12

 Times Cited Count:0 Percentile:0(Engineering, Electrical & Electronic)

In this study, we employed a superconducting detector, current-biased kinetic-inductance detector (CB-KID) for neutron imaging using a pulsed neutron source. We employed the delay-line method, and high spatial resolution imaging with only four reading channels was achieved. We also performed wavelength-resolved neutron imaging by the time-of-flight method. We obtained the neutron transmission images of a Gd-Al alloy sample, inside which single crystals of GdAl$$_{3}$$ were grown, using the delay-line CB-KID. Single crystals were well imaged, in both shapes and distributions, throughout the Al-Gd alloy. We identified Gd nuclei via neutron transmissions that exhibited characteristic suppression above the neutron wavelength of 0.03 nm. In addition, the $$_{155}$$Gd resonance dip, a dip structure of the transmission caused by the nuclear reaction between an isotope and neutrons, was observed even when the number of events was summed over a limited area of 15 $$mu$$m $$times$$ 12 $$mu$$m. Gd selective imaging was performed using the resonance dip of $$_{155}$$Gd, and it showed clear Gd distribution even with a limited neutron wavelength range of 1 pm.

Journal Articles

Practical tests of neutron transmission imaging with a superconducting kinetic-inductance sensor

Vu, TheDang; Shishido, Hiroaki*; Aizawa, Kazuya; Kojima, Kenji M*; Koyama, Tomio*; Oikawa, Kenichi; Harada, Masahide; Oku, Takayuki; Soyama, Kazuhiko; Miyajima, Shigeyuki*; et al.

Nuclear Instruments and Methods in Physics Research A, 1006, p.165411_1 - 165411_8, 2021/08

 Times Cited Count:1 Percentile:18.91(Instruments & Instrumentation)

JAEA Reports

Handling of HTTR second driver fuel elements in assembling and storage working

Tomimoto, Hiroshi; Kato, Yasushi; Owada, Hiroyuki; Sato, Nao; Shimazaki, Yosuke; Kozawa, Takayuki; Shinohara, Masanori; Hamamoto, Shimpei; Tochio, Daisuke; Nojiri, Naoki; et al.

JAEA-Technology 2009-025, 29 Pages, 2009/06

JAEA-Technology-2009-025.pdf:21.78MB

The first driver fuel of the HTTR (High Temperature Engineering test Reactor) was loaded in 1998 and the HTTR reached first criticality state in the same year. The HTTR has been operated using the first driver fuel for a decade. In Fuel elements assembling, 4770 of fuel rods which consist of 12 kinds of enrichment uranium are loaded into 150 fuel graphite blocks for HTTR second driver fuel elements. Measures of prevention of fuel rod miss loading, are employed in fuel design. Additionally, precaution of fuel handling on assembling are considered. Reception of fuel rods, assembling of fuel elements and storage of second driver fuels in the fresh fuel storage rack in the HTTR were started since June, 2008. Assembling, storage and pre-service inspection were divided into three parts. The second driver fuel assembling was completed in September, 2008. This report describes concerns of fuel handling on assembling and storage work for the HTTR fuel elements.

JAEA Reports

Development on crack growth and crack initiation test units for stress corrosion cracking examinations in high-temperature water environments under neutron irradiation, 1 (Contract research)

Izumo, Hironobu; Chimi, Yasuhiro; Ishida, Takuya; Kawamata, Kazuo; Inoue, Shuichi; Ide, Hiroshi; Saito, Takashi; Ise, Hideo; Miwa, Yukio; Ugachi, Hirokazu; et al.

JAEA-Technology 2009-011, 31 Pages, 2009/04

JAEA-Technology-2009-011.pdf:4.38MB

Regarding Irradiation Assisted Stress Corrosion Cracking (IASCC) for austenitic stainless steel of the light water reactor (LWR), a lot of data that concerns the post irradiation evaluation (PIE) is acquired. However, IASCC occurs in LWR condition. Therefore, it is necessary to confirm adequacy of the PIE data comparing the experiment data under the simulated LWR condition. Bigger specimen is needed to acquire the effective data for the destruction dynamics in the study of stress corrosion cracking under neutron irradiation condition. Therefore, development of a new crack growth unit which can load to bigger is necessary to the neutron irradiation test. As a result, a prospect was provided in the unit that could load to specimen by changing load mechanism to the lever type from the linear type. And also, in the development of crack propagation unit, some technical issues were extracted from the discussion of the unit structure adopting the LVDT (Linear Variable Differential Transformer).

JAEA Reports

Fabrication of irradiation capsule for IASCC irradiation tests, 2; Irradiation capsule for crack propagation test (Joint research)

Ide, Hiroshi; Matsui, Yoshinori; Kawamata, Kazuo; Taguchi, Taketoshi; Kanazawa, Yoshiharu; Onuma, Yuichi; Watanabe, Hiroyuki; Inoue, Shuichi; Izumo, Hironobu; Ishida, Takuya; et al.

JAEA-Technology 2008-012, 36 Pages, 2008/03

JAEA-Technology-2008-012.pdf:10.09MB

It is known that Irradiation Assisted Stress Corrosion Cracking (IASCC) occurs when austenitic stainless steel components used for light water reactor (LWR) are irradiated for a long period. In order to evaluate the high aging of the nuclear power plant, the study of IASCC becomes the important problem. The specimens irradiated in the reactor were evaluated by post irradiation examination in the past study. For the appropriate evaluation of IASCC, It is necessary to test it under the simulated LWR conditions; temperature, water chemistry and irradiation conditions. In order to perform in-pile SCC test, saturated temperature capsule (SATCAP) was developed. There are crack growth test, crack propagation test and so on for in-pile SCC test. In this report, SATCAP for crack propagation test is reported.

JAEA Reports

Fabrication of irradiation capsule for IASCC irradiation tests, 1; Irradiation capsule for crack growth test (Joint research)

Ide, Hiroshi; Matsui, Yoshinori; Kawamata, Kazuo; Taguchi, Taketoshi; Kanazawa, Yoshiharu; Onuma, Yuichi; Watanabe, Hiroyuki; Inoue, Shuichi; Izumo, Hironobu; Ishida, Takuya; et al.

JAEA-Technology 2008-011, 46 Pages, 2008/03

JAEA-Technology-2008-011.pdf:19.39MB

It is known that Irradiation Assisted Stress Corrosion Cracking (IASCC) occurs when austenitic stainless steel components used for light water reactor (LWR) are irradiated for a long period. In order to evaluate the high aging of the nuclear power plant, the study of IASCC becomes the important problem. The specimens irradiated in the reactor were evaluated by post irradiation examination in the past study. For the appropriate evaluation of IASCC, It is necessary to test it under the simulated LWR conditions; temperature, water chemistry and irradiation conditions. In order to perform in-pile SCC test, saturated temperature capsule (SATCAP) was developed. There are crack growth test, crack propagation test and so on for in-pile SCC test. In this report, SATCAP for crack growth test is reported.

Journal Articles

Torque magnetometry of twinned YBa$$_{2}$$Cu$$_{3}$$O$$_{7}$$ single crystal

Ishida, Takekazu*; Kawamata, Shuichi*; Okuda, Kiichi*; Asaoka, Hidehito; ; Noda, Kenji; *

Advances in Superconductivity VIII, 0, p.189 - 192, 1996/00

no abstracts in English

9 (Records 1-9 displayed on this page)
  • 1