Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Shimomura, Koichiro*; Koda, Akihiro*; Pant, A. D.*; Sunagawa, Hikaru*; Fujimori, Hiroshi*; Umegaki, Izumi*; Nakamura, Jumpei*; Fujihara, Masayoshi; Tampo, Motonobu*; Kawamura, Naritoshi*; et al.
Interactions (Internet), 245(1), p.31_1 - 31_6, 2024/12
Ishikado, Motoyuki*; Takahashi, Ryuta*; Yamauchi, Yasuhiro*; Nakamura, Masatoshi*; Ishimaru, Sora*; Yamauchi, Sara*; Kawamura, Seiko; Kira, Hiroshi*; Sakaguchi, Yoshifumi*; Watanabe, Masao; et al.
JPS Conference Proceedings (Internet), 41, p.011010_1 - 011010_7, 2024/05
Kofu, Maiko; Kawamura, Seiko; Murai, Naoki; Ishii, Rieko*; Hirai, Daigoro*; Arima, Hiroshi*; Funakoshi, Kenichi*
Physical Review Research (Internet), 6(1), p.013006_1 - 013006_9, 2024/01
Kumada, Takayuki; Nakagawa, Hiroshi; Miura, Daisuke; Sekine, Yurina; Motokawa, Ryuhei; Hiroi, Kosuke; Inamura, Yasuhiro; Oku, Takayuki; Oishi, Kazuki*; Morikawa, Toshiaki*; et al.
Journal of Physical Chemistry Letters (Internet), 14(34), p.7638 - 7643, 2023/08
Times Cited Count:0 Percentile:0.01(Chemistry, Physical)The structure of nano-ice crystals in rapidly frozen glucose solution was elucidated by using spin-contrast-variation small-angle neutron scattering, which distinguishes the nano-ice crystal signal from the frozen amorphous solution signal by the polarization-dependent neutron scattering. The analysis revealed that the nano-ice crystals form a planar structure with a diameter exceeding tens of nanometers and a thickness of 1 nm, which is close to the critical nucleation size. This result suggests that the glucose molecules are preferentially bound to a specific face of nano-ice crystals, and then block the crystal growth perpendicular to that face.
Shimomura, Koichiro*; Koda, Akihiro*; Pant, A. D.*; Natori, Hiroaki*; Fujimori, Hiroshi*; Umegaki, Izumi*; Nakamura, Jumpei*; Tampo, Motonobu*; Kawamura, Naritoshi*; Teshima, Natsuki*; et al.
Journal of Physics; Conference Series, 2462, p.012033_1 - 012033_5, 2023/03
Times Cited Count:0 Percentile:0.2(Physics, Applied)Iwasa, Kazuaki*; Suyama, Kazuya*; Kawamura, Seiko; Nakajima, Kenji; Raymond, S.*; Steffens, P.*; Yamada, Akira*; Matsuda, Tatsuma*; Aoki, Yuji*; Kawasaki, Ikuto; et al.
Physical Review Materials (Internet), 7(1), p.014201_1 - 014201_11, 2023/01
Times Cited Count:2 Percentile:72.03(Materials Science, Multidisciplinary)Yotsuji, Kenji*; Tachi, Yukio; Sakuma, Hiroshi*; Kawamura, Katsuyuki*
Genshiryoku Bakkuendo Kenkyu (CD-ROM), 29(2), p.63 - 81, 2022/12
The understanding of the swelling phenomenon of montmorillonite is essential to predict the physical and chemical behavior of clay-based barriers in radioactive waste disposal systems. This study investigated the key factors controlling crystalline swelling behavior of montmorillonite with different interlayer counter-ions by molecular dynamics (MD) simulations. On the basis of the comparisons between MD simulated and experimental results, the water content in the interlayer in five homoionic (Na, K, Cs, Ca and Sr) montmorillonite was strongly correlated to the hydration number and the preference of an outer- or inner-sphere complex of each counter-ion. The detailed analysis for these results offer insights that the hydration number is controlled by the hydration free energy, the volume and the distribution of each interlayer counter-ion. The systematic MD simulations with virtually variable parameters clarified that the hydration free energy and the charge of interlayer counter- ions compete as influencing factors, and the control the formation rate of an outer-sphere complex of each counter-ion. The empirical relationships between these key factors will allow essential insights into predicting the swelling behavior of montmorillonite with different interlayer counter-ions.
Yotsuji, Kenji*; Tachi, Yukio; Sakuma, Hiroshi*; Kawamura, Katsuyuki*
Applied Clay Science, 204, p.106034_1 - 106034_13, 2021/04
Times Cited Count:61 Percentile:99.73(Chemistry, Physical)Miura, Daisuke*; Kumada, Takayuki; Sekine, Yurina; Motokawa, Ryuhei; Nakagawa, Hiroshi; Oba, Yojiro; Ohara, Takashi; Takata, Shinichi; Hiroi, Kosuke; Morikawa, Toshiaki*; et al.
Journal of Applied Crystallography, 54(2), p.454 - 460, 2021/04
Times Cited Count:1 Percentile:17.63(Chemistry, Multidisciplinary)We developed a spin-contrast-variation neutron powder diffractometry technique that extracts the structure factor of hydrogen atoms, namely, the contribution of hydrogen atoms to a crystal structure factor. Crystals of L-glutamic acid were dispersed in a dpolystyrene matrix containing 4-methacryloyloxy-2,2,6,6,-tetramethyl-1-piperidinyloxy (TEMPO methacrylate) to polarize their proton spins dynamically. The intensities of the diffraction peaks of the sample changed according to the proton polarization, and the structure factor of the hydrogen atoms was extracted from the proton-polarization dependent intensities. This technique is expected to enable analyses of the structures of hydrogen-containing materials that are difficult to determine with conventional powder diffractometry.
Nakagawa, Hiroshi; Yonetani, Yoshiteru*; Nakajima, Kenji; Kawamura, Seiko; Kikuchi, Tatsuya*; Inamura, Yasuhiro; Kataoka, Mikio*; Kono, Hidetoshi*
JPS Conference Proceedings (Internet), 33, p.011101_1 - 011101_6, 2021/03
Hydration water dynamics were measured by quasi-elastic neutron scattering with HnO/DO contrast for two DNA dodecamers, 5'CGCGCGCG'3 and 5'CGCGCGCG'3, which have been computationally shown to be structurally rigid and flexible, respectively. The dynamical transitions of the hydration water as well as DNA were observed for both sequences at approximately 240 K. Above the transition temperature, the mean square displacements of the hydration water for the rigid sequence were smaller than those for the flexible one. Furthermore, the relaxation time of the hydration water was longer in the rigid DNA than in the flexible DNA. We suggest that hydration water dynamics on the picosecond timescale are associated with sequence-dependent deformability of DNA.
Ueda, Hiroshi*; Onoda, Shigeki*; Yamaguchi, Yasuhiro*; Kimura, Tsuyoshi*; Yoshizawa, Daichi*; Morioka, Toshiaki*; Hagiwara, Masayuki*; Hagihara, Masato*; Soda, Minoru*; Masuda, Takatsugu*; et al.
Physical Review B, 101(14), p.140408_1 - 140408_6, 2020/04
Times Cited Count:4 Percentile:26.53(Materials Science, Multidisciplinary)Kawamura, Seiko; Takahashi, Ryuta*; Ishikado, Motoyuki*; Yamauchi, Yasuhiro*; Nakamura, Masatoshi*; Ouchi, Keiichi*; Kira, Hiroshi*; Kambara, Wataru*; Aoyama, Kazuhiro*; Sakaguchi, Yoshifumi*; et al.
Journal of Neutron Research, 21(1-2), p.17 - 22, 2019/05
The Cryogenics and Magnets group in the Sample Environment team is responsible for operation of cryostats and magnets for user's experiments at the MLF in J-PARC. We have introduced a top-loading He cryostat, a bottom-loading He cryostat, a dilution refrigerator insert and a superconducting magnet. The frequency of use of them dramatically becomes higher in these two years, as the beam power and the number of proposal increase. To respond such situation, we have made efforts to enhance performance of these equipment as follows. The He cryostat originally involves an operation software for automatic initial cooling down to the base temperature and automatic re-charge of He. Recently we made an additional program for automatic temperature control with only the sorb heater. Last year, a new outer vacuum chamber of the magnet with an oscillating radial collimator (ORC) was fabricated. The data quality was drastically improved by introducing this ORC so that the magnet can be used even for the inelastic neutron scattering experiments.
Kajimoto, Ryoichi; Ishikado, Motoyuki*; Kira, Hiroshi*; Kaneko, Koji; Nakamura, Mitsutaka; Kamazawa, Kazuya*; Inamura, Yasuhiro; Ikeuchi, Kazuhiko*; Iida, Kazuki*; Murai, Naoki; et al.
Physica B; Condensed Matter, 556, p.26 - 30, 2019/03
Times Cited Count:2 Percentile:10.61(Physics, Condensed Matter)Yotsuji, Kenji*; Tachi, Yukio; Kawamura, Katsuyuki*; Arima, Tatsumi*; Sakuma, Hiroshi*
Nendo Kagaku, 58(1), p.8 - 25, 2019/00
Molecular dynamics (MD) simulations were conducted to investigate physical properties of water and cations in montmorillonite interlayer nanopores. The swelling behaviors and hydration states were firstly evaluated as functions of interlayer cations and layer charge. The diffusion coefficients of water and cations in interlayer nanopores were decreased in comparison with those in bulk water and came closer to those in bulk water when basal spacing increased. The viscosity coefficients of interlayer water estimated indicated a significant effect of viscoelectricity at 1- and 2-layer hydration states and higher layer charge of montmorillonite. These trends from MD calculations were confirmed to be consistent with existing measured data and previous MD simulation. In addition, model and parameter related to viscoelectric effect used in the diffusion model was refined based on comparative discussion between MD simulations and measurements. The series of MD calculations could provide atomic level understanding for the developments and improvements of the diffusion model for compacted montmorillonite.
Kajimoto, Ryoichi; Nakamura, Mitsutaka; Inamura, Yasuhiro; Kamazawa, Kazuya*; Ikeuchi, Kazuhiko*; Iida, Kazuki*; Ishikado, Motoyuki*; Murai, Naoki; Kira, Hiroshi*; Nakatani, Takeshi; et al.
Journal of Physics; Conference Series, 1021(1), p.012030_1 - 012030_6, 2018/06
Times Cited Count:3 Percentile:88.67(Nuclear Science & Technology)Kadowaki, Hiroaki*; Wakita, Mika*; Fk, B.*; Ollivier, J.*; Kawamura, Seiko; Nakajima, Kenji; Takatsu, Hiroshi*; Tamai, Mototake*
Journal of the Physical Society of Japan, 87(6), p.064704_1 - 064704_6, 2018/06
Times Cited Count:9 Percentile:57.38(Physics, Multidisciplinary)The ground states of the frustrated pyrochlore oxide TbTiO have been studied by inelastic neutron scattering experiments. Three single-crystal samples are investigated; one shows no phase transition (), being a putative quantum spin-liquid (QSL), and the other two () show electric quadrupole ordering (QO) below K. The QSL sample shows continuum excitation spectra with an energy scale 0.1 meV as well as energy-resolution-limited (nominally) elastic scattering. As is increased, pseudospin wave of the QO state emerges from this continuum excitation, which agrees with that of powder samples and consequently verifies good control for the present single crystal samples.
Kawamura, Seiko; Oku, Takayuki; Watanabe, Masao; Takahashi, Ryuta; Munakata, Koji*; Takata, Shinichi; Sakaguchi, Yoshifumi*; Ishikado, Motoyuki*; Ouchi, Keiichi*; Hattori, Takanori; et al.
Journal of Neutron Research, 19(1-2), p.15 - 22, 2017/11
Sample environment (SE) team at the Materials and Life Science Experimental Facility (MLF) in J-PARC has worked on development and operation of SE equipment and devices. All the members belong to one sub-team at least, such as Cryogenic and magnet, High temperature, High pressure, Soft matter and special environment including Pulse magnet, Hydrogen environment, Light irradiation and He spin filter. Cryostats, a magnet, furnaces, a VX-6-type Paris-Edinburgh press and a prototype of a Spin-Exchange Optical Pumping (SEOP) based He spin filter for polarized neutron beam experiments are in operation. Furthermore, a prototype of compact power supply for a pulsed magnet system is currently developed. In the J-PARC Research Building, several pieces of equipment for softmatter research such as a rheometer and a gas and vapor adsorption measurement instrument have been prepared.
Sakasai, Kaoru; Sato, Setsuo*; Seya, Tomohiro*; Nakamura, Tatsuya; To, Kentaro; Yamagishi, Hideshi*; Soyama, Kazuhiko; Yamazaki, Dai; Maruyama, Ryuji; Oku, Takayuki; et al.
Quantum Beam Science (Internet), 1(2), p.10_1 - 10_35, 2017/09
Neutron devices such as neutron detectors, optical devices including supermirror devices and He neutron spin filters, and choppers are successfully developed and installed at the Materials Life Science Facility (MLF) of the Japan Proton Accelerator Research Complex (J-PARC), Tokai, Japan. Four software components of MLF computational environment, instrument control, data acquisition, data analysis, and a database, have been developed and equipped at MLF. MLF also provides a wide variety of sample environment options including high and low temperatures, high magnetic fields, and high pressures. This paper describes the current status of neutron devices, computational and sample environments at MLF.
Sakuma, Hiroshi*; Tachi, Yukio; Yotsuji, Kenji; Suehara, Shigeru*; Arima, Tatsumi*; Fujii, Naoki*; Kawamura, Katsuyuki*; Honda, Akira
Clays and Clay Minerals, 65(4), p.252 - 272, 2017/08
Times Cited Count:2 Percentile:16.51(Chemistry, Physical)Structure and stability of montmorillonite edge faces (110), (010), (100), and (130) of the layer charges y = 0.5 and 0.33 are investigated by the first-principles electronic calculations based on the density functional theory. Stacking and single layer models are tested for understanding the effect of stacking on the stability of montmorillonite edge faces. Most stacking layers stabilize the edge faces by making hydrogen bonds between the layers; therefore, the surface energy of stacking layers is reduced rather than the single layer model. This indicates that the surface energy of edge faces should be estimated depending on the swelling conditions. Lowest surface energies of (010) and (130) edge faces were realized by the presence of Mg ions on the edge faces. These edge faces have a strong adsorption site for cations due to local negative charge of the edges.
Kawamura, Takuma; Idomura, Yasuhiro; Miyamura, Hiroko; Takemiya, Hiroshi
Journal of Visualization, 20(1), p.151 - 162, 2017/02
Times Cited Count:3 Percentile:18.26(Computer Science, Interdisciplinary Applications)In this paper, we propose a novel transfer function design interface for multivariate volume rendering. In the conventional multivariate volume rendering, GUI based transfer function design interfaces were limited to two-dimensional variables space. In order to design higher dimensional transfer functions in an interactive and intuitive manner, a Transfer Function Synthesizer (TFS) is developed. On the TFS, multi-dimensional transfer functions are generated by algebraic synthesis of one-dimensional transfer functions, which are designed based on the conventional GUIs or algebraic expressions. The TFS enables not only multivariate volume rendering but also general visualization techniques such as surface visualization and image composition within the framework of volume rendering. The TFS is implemented on the remote visualization system PBVR, and applied to various multivariate scalar volume data generated from nuclear applications.