Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 25

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Nanoscopic structure of borosilicate glass with additives for nuclear waste vitrification

Motokawa, Ryuhei; Kaneko, Koji; Oba, Yojiro; Nagai, Takayuki; Okamoto, Yoshihiro; Kobayashi, Taishi*; Kumada, Takayuki; Heller, W. T.*

Journal of Non-Crystalline Solids, 578, p.121352_1 - 121352_7, 2022/02

 Times Cited Count:3 Percentile:22.84(Materials Science, Ceramics)

Journal Articles

Hydrological gravity response detection using a gPhone below- and aboveground

Tanaka, Toshiyuki*; Miyajima, Rikio*; Asai, Hideaki*; Horiuchi, Yasuharu; Kumada, Koji; Asai, Yasuhiro*; Ishii, Hiroshi*

Earth Planets and Space, 65(2), p.59 - 66, 2013/02

 Times Cited Count:8 Percentile:23.68(Geosciences, Multidisciplinary)

Journal Articles

Multistep lattice-voxel method utilizing lattice function for Monte-Carlo treatment planning with pixel based voxel model

Kumada, Hiroaki*; Saito, Kimiaki; Nakamura, Takemi; Sakae, Takeji*; Sakurai, Hideyuki*; Matsumura, Akira*; Ono, Koji*

Proceedings of 14th International Congress on Neutron Capture Therapy (ICNCT-14) (CD-ROM), p.238 - 241, 2010/10

Journal Articles

Feasible evaluation of neutron capture therapy for hepatocellular carcinoma using selective enhancement of boron accumulation in tumour with intra-arterial administration of boron-entrapped water-in-oil-in-water emulsion

Yanagie, Hironobu*; Kumada, Hiroaki*; Nakamura, Takemi; Higashi, Shushi*; Ikushima, Ichiro*; Morishita, Yasuyuki*; Shinohara, Atsuko*; Fujiwara, Mitsuteru*; Suzuki, Minoru*; Sakurai, Yoshinori*; et al.

Proceedings of 14th International Congress on Neutron Capture Therapy (ICNCT-14) (CD-ROM), p.157 - 160, 2010/10

Journal Articles

Data processing methods for dynamic neutron tomography velocimetry

Kureta, Masatoshi; Kumada, Hiroaki; Kume, Etsuo; Someya, Satoshi*; Okamoto, Koji*

Proceedings of 3rd International Workshop on Process Tomography (IWPT-3) (CD-ROM), 8 Pages, 2009/04

Dynamic neutron tomography velocimetry has been developed in order to obtain the 3-D velocity distribution and flow profile data of liquid metal flow in a heated rod bundle for development of an advanced nuclear reactor. In this paper, data processing methods for the 3-D velocimetry is focused on. The data processing is started from the reading images recorded by the three high-speed video cameras, and is finished to the visualization of velocity of the tracers and the profiles. Basic experiments were carried out using the research reactor JRR-4 and the dynamic neutron tomography system. As the results, it was confirmed that the 3-D velocity distribution and flow profile could be visualized by the new data processing methods.

Journal Articles

Dynamic neutron computer tomography technique for velocity measurement in liquid metal flow; Fundamental PTV experiment

Kureta, Masatoshi; Kumada, Hiroaki*; Kume, Etsuo; Someya, Satoshi*; Okamoto, Koji*

Journal of Physics; Conference Series, 147, p.012087_1 - 012087_14, 2009/03

The aim of this development is to visualize and measure the velocity distribution in liquid metal flow using the neutron beam with the high-speed imaging technique, computer tomography (CT) technique and particle tracking velocimetry (PTV). Final research purpose is to obtain the velocity distribution and flow profile data of liquid metal flow in a heated rod bundle for development of the FBR core. In this paper, visualization and measurement method using the JRR-4, spring model PTV method for this technique and results of the fundamental PTV experiment were reported. The fundamental experiment was conducted. As the result, cadmium tracers buried in the aluminum column with the speed of 1.5 revolving per second could be visualized as the 3D movie under 125Hz and 250Hz sampling conditions, the profile of the tracer could be traced, and fundamental velocity distribution measurement method could be conformed.

Journal Articles

Dynamic neutron computer tomography technique for velocity measurement in liquid metal flow; Fundamental PTV experiment

Kureta, Masatoshi; Kumada, Hiroaki; Kume, Etsuo; Someya, Satoshi*; Okamoto, Koji*

Proceedings of 6th International Symposium on Measurement Techniques for Multiphase Flows (ISMTMF 2008) (USB Flash Drive), 14 Pages, 2008/12

The aim of this development is to visualize and measure the velocity distribution in liquid metal flow using the neutron beam with the high-speed imaging technique, computer tomography (CT) technique and particle tracking velocimetry (PTV). Final research purpose is to obtain the velocity distribution and flow profile data of liquid metal flow in a heated rod bundle for development of the FBR core. In this paper, visualization and measurement method using the JRR-4, spring model PTV method for this technique and results of the fundamental PTV experiment were reported. The fundamental experiment was conducted. As the result, cadmium tracers buried in the aluminum column with the speed of 1.5 revolving per second could be visualized as the 3D movie under 125 Hz and 250 Hz sampling conditions, the profile of the tracer could be traced, and fundamental velocity distribution measurement method could be conformed.

Journal Articles

Successful BNCT for patients with cutaneous and mucosal melanomas; Report of 4 cases

Morita, Norimasa*; Hiratsuka, Junichi*; Kuwabara, Chiaki*; Aihara, Teruhito*; Ono, Koji*; Fukuda, Hiroshi*; Kumada, Hiroaki; Harada, Tamotsu*; Imajo, Yoshinari*

Proceedings of 12th International Congress on Neutron Capture Therapy (ICNCT-12), p.18 - 20, 2006/12

Since 2003, group of Kawasaki Medical School has conducted BNCT clinical trials on melanomas at the Kyoto University Research Reactor (KUR) and Japan Research Reactor No.4 (JRR-4). We report 4 patients given BNCT for malignant melanomas, 2 with superficial spreading types on the heel, 1 with mucosal melanoma in the nasal cavity, and 1with a melanoma on the vulva and in the vagina. Although 2 patients experienced normal-tissue damage that exceeded the tolerance level, all the participants were cured within a few months of treatment. BNCT was shown to be a promising treatment for mucosal, as well as for cutaneous, melanomas.

Journal Articles

Development of a real-time thermal neutron monitor and its clinical application

Ishikawa, Masayori*; Ono, Koji*; Matsumura, Akira*; Yamamoto, Tetsuya*; Hiratsuka, Junichi*; Miyatake, Shinichi*; Kato, Itsuro*; Sakurai, Yoshinori*; Kobayashi, Toru*; Kumada, Hiroaki; et al.

Proceedings of 12th International Congress on Neutron Capture Therapy (ICNCT-12), p.397 - 400, 2006/10

An ultraminiature thermal neutron monitor which was named SOF detector (Scintillator with Optical Fiber detector) had been developed for BNCT treatment. We had been experienced 15 clinical trials using SOF detector until the end of 2005, some measurements got good results, and some got unacceptable results. One reason of the unacceptable results was due to dislocation of the detector during treatment. This is because it is difficult to fix the SOF detector on patient's skin without strong sticker. To overcome this problem, a loop-type SOF probe was developed. By using the loop-type SOF detector, fixing on the patient's skin was much easier.

Journal Articles

Basic and clinical studies for application of epithermal neutron beam for neutron capture therapy

Nose, Tadao*; Matsumura, Akira*; Yamamoto, Tetsuya*; Shibata, Yasushi*; Yoshida, Fumiyo*; Akutsu, Hiroyoshi*; Yasuda, Susumu*; Matsushita, Akira*; Nakai, Kei*; Yamada, Takashi*; et al.

UTRCN-G-29, p.114 - 123, 2001/00

no abstracts in English

Journal Articles

Intraoperative boron neturon capture therapy for malignant gliomas; First clinical results of Tsukuba phase I/II trial using JAERI mixed thermal-epithermal beam

Matsumura, Akira*; Yamamoto, Tetsuya*; Shibata, Yasushi*; Akutsu, Hiroyoshi*; Yasuda, Susumu*; Matsushita, Akira*; Nakai, K.*; Yamada, Takashi*; Takano, Shingo*; Mizutani, Taro*; et al.

Proceedings of 9th International Symposium on Neutron Capture Therapy for Cancer, p.29 - 30, 2000/10

no abstracts in English

Journal Articles

Radiobiogical characterization of epithermal and mixed thermal-epithermal beams at JRR-4

Yamamoto, Tetsuya*; Matsumura, Akira*; Shibata, Yasushi*; Nose, Tadao*; Yamamoto, Kazuyoshi; Kumada, Hiroaki; Hori, Naohiko; Torii, Yoshiya; Ono, Koji*; Kobayashi, Toru*; et al.

Proceedings of 9th International Symposium on Neutron Capture Therapy for Cancer, p.205 - 206, 2000/10

no abstracts in English

Oral presentation

Estimation of thermal neutron flux distribution with an annular beam irradiation method for neutron capture therapy

Kumada, Hiroaki; Yamamoto, Kazuyoshi; Ono, Koji*

no journal, , 

no abstracts in English

Oral presentation

Development of dynamic neutron computer tomography for the thermal-hydraulic evaluation of liquid metal, 1; Development of the system and fundamental tests

Kureta, Masatoshi; Kumada, Hiroaki; Kume, Etsuo; Someya, Satoshi*; Okamoto, Koji*

no journal, , 

Development of the Dynamic Neutron Computer Tomography (DNCT) technique is started as the new 4D thermal-hydraulic measurement technique in order to provide the detailed database for thermal-hydraulic evaluation methods on liquid metal cooled FBR core. In this presentation, development of the DNCT system and fundamental tests carried out in the JRR-4 are reported. Basic principal of the DNCT, that is, six neutron radiography projection images are recorded with high speed at the same time was confirmed.

Oral presentation

Study of irradiation techniques for reduction in skin dose and for improvement of dose distribution in BNCT at JRR-4

Kumada, Hiroaki; Nakamura, Takemi; Ono, Koji*; Maruhashi, Akira*; Matsumura, Akira*

no journal, , 

no abstracts in English

Oral presentation

Clinical study of neutron capture therapy for locally recurrent breast cancer

Yanagie, Hironobu*; Sakurai, Yoshinori*; Kumada, Hiroaki; Naka, Hideji*; Furuya, Yoshitaka*; Takamoto, Shinichi*; Ono, Koji*; Takahashi, Hiroyuki*

no journal, , 

no abstracts in English

Oral presentation

Development of high-speed three-dimensional measurement technique for liquid metal thermo-fluid dynamics

Okamoto, Koji*; Someya, Satoshi*; Kureta, Masatoshi; Kumada, Hiroaki; Kume, Etsuo

no journal, , 

no abstracts in English

Oral presentation

Recent irradiation technique for BNCT in JRR-4

Nakamura, Takemi; Kishi, Toshiaki; Kumada, Hiroaki; Kusunoki, Tsuyoshi; Matsumura, Akira*; Ono, Koji*

no journal, , 

no abstracts in English

Oral presentation

Verification for dosimetry performance of JCDS with PHITS

Kumada, Hiroaki; Matsumura, Akira*; Maruhashi, Akira*; Niita, Koji*; Seki, Akiyuki; Imaki, Tadashi*

no journal, , 

no abstracts in English

Oral presentation

Development of dynamic neutron computer tomography; Fundamental tests for 4 dimensional velocity measurement

Kureta, Masatoshi; Kumada, Hiroaki; Kume, Etsuo; Someya, Satoshi*; Okamoto, Koji*

no journal, , 

The paper proposes a new measurement technique named as dynamic neutron computer tomography (CT). The purpose of the development is to visualize and measure the three-dimensional velocity distribution in liquid metal flow based on high-speed neutron radiography and CT techniques. The dynamic neutron CT system generates six neutron beams and neutron radiography images at the same time. And the images are recorded by three set of high-speed video camera systems in the neutron irradiation room of the research reactor JRR-4. Consecutive instantaneous CT value 3D distributions were visualized using a fundamental rotating test section for the dynamic neutron CT test with the developed system.

25 (Records 1-20 displayed on this page)