Refine your search:     
Report No.
 - 
Search Results: Records 1-18 displayed on this page of 18
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Engineering validation and engineering design of lithium target facility in IFMIF/EVEDA project

Wakai, Eiichi; Kondo, Hiroo; Kanemura, Takuji; Furukawa, Tomohiro; Hirakawa, Yasushi; Watanabe, Kazuyoshi; Ida, Mizuho*; Ito, Yuzuru; Niitsuma, Shigeto; Edao, Yuki; et al.

Fusion Science and Technology, 66(1), p.46 - 56, 2014/07

 Times Cited Count:4 Percentile:31.13(Nuclear Science & Technology)

Journal Articles

Development of lithium target system in engineering validation and engineering design activity of the International Fusion Materials Irradiation Facility (IFMIF/EVEDA)

Wakai, Eiichi; Kondo, Hiroo; Sugimoto, Masayoshi; Fukada, Satoshi*; Yagi, Juro*; Ida, Mizuho; Kanemura, Takuji; Furukawa, Tomohiro; Hirakawa, Yasushi; Watanabe, Kazuyoshi; et al.

Purazuma, Kaku Yugo Gakkai-Shi, 88(12), p.691 - 705, 2012/12

AA2012-1008.pdf:2.42MB

no abstracts in English

Journal Articles

Present status of Japanese tasks for lithium target facility under IFMIF/EVEDA

Nakamura, Kazuyuki; Furukawa, Tomohiro; Hirakawa, Yasushi; Kanemura, Takuji; Kondo, Hiroo; Ida, Mizuho; Niitsuma, Shigeto; Otaka, Masahiko; Watanabe, Kazuyoshi; Horiike, Hiroshi*; et al.

Fusion Engineering and Design, 86(9-11), p.2491 - 2494, 2011/10

 Times Cited Count:10 Percentile:61.04(Nuclear Science & Technology)

In IFMIF/EVEDA, tasks for lithium target system are shared to 5 validation tasks (LF1-5) and a design task (LF6). The purpose of LF1 task is to construct and operate the EVEDA lithium test loop, and JAEA has a main responsibility to the performance of the Li test loop. LF2 is a task for the diagnostics of the Li test loop and IFMIF design. Basic research for the diagnostics equipment has been completed, and the construction for the Li test loop will be finished before March in 2011. LF4 is a task for the purification systems with nitrogen and hydrogen. Basic research for the purification equipment has been completed, and the construction of the nitrogen system for the Li test loop will be finished before March in 2011. LF5 is a task for the remote handling system with the target assembly. JAEA has an idea to use the laser beam for cutting and welding of the lip part of the flanges. LF6 is a task for the design of the IFMIF based on the validation experiments of LF1-5.

JAEA Reports

Analytical work at NUCEF in FY 2006

Sakazume, Yoshinori; Aoki, Hiromichi; Haga, Takahisa; Fukaya, Hiroyuki; Sonoda, Takashi; Shimizu, Kaori; Niitsuma, Yasushi*; Ito, Mitsuo; Inoue, Takeshi

JAEA-Technology 2007-069, 44 Pages, 2008/02

JAEA-Technology-2007-069.pdf:4.55MB

Analysis of the uranyl nitrate solution fuel is carried out at the analytical laboratory of NUCEF (Nuclear Fuel Cycle Engineering Research Facility), which provides essential data for operation of STACY (Static Experiment Critical Facility), TRACY (Transient Experiment Critical Facility) and the fuel treatment system. Analyzed in FY 2006 were uranyl nitrate solution fuel samples taken before and after experiments of STACY and TRACY, samples for the preparation of uranyl nitrate solution fuel, and samples for nuclear material accountancy purpose. The total number of the samples analyzed in FY 2006 was 254. This report summarizes work related to the analysis and management of the analytical laboratory in the FY 2006.

JAEA Reports

Analytical work at NUCEF in FY 2005

Fukaya, Hiroyuki; Aoki, Hiromichi; Haga, Takahisa; Nishizawa, Hidetoshi; Sonoda, Takashi; Sakazume, Yoshinori; Shimizu, Kaori; Niitsuma, Yasushi*; Shirahashi, Koichi; Inoue, Takeshi

JAEA-Technology 2007-005, 27 Pages, 2007/03

JAEA-Technology-2007-005.pdf:1.97MB

Analysis of the uranyl nitrate solution fuel is carried out at the analytical laboratory of NUCEF (Nuclear Fuel Cycle Engineering Research Facility), which provides essential data for operation of STACY (Static Experiment Critical Facility), TRACY (Transient Experiment Critical Facility) and the fuel treatment system. Analyzed in FY 2005 were uranyl nitrate solution fuel samples taken before and after experiments of STACY and TRACY, samples for the preparation of uranyl nitrate solution fuel, and samples for nuclear material accountancy purpose. Also analyzed were the samples from raffinate treatment and its preliminary tests. The raffinate was generated, since FY 2000, during preliminary experiments on U/Pu extraction-pulification to fix the operation condition to prepare plutonium solution fuel to be used for criticality experiments at STACY. This report summarizes work related to the analysis and management of the analytical laboratory in the FY 2005.

JAEA Reports

Annual report on analytical works at NUCEF in FY 2004

Nishizawa, Hidetoshi; Fukaya, Hiroyuki; Sonoda, Takashi; Sakazume, Yoshinori; Shimizu, Kaori; Haga, Takahisa; Sakai, Yutaka*; Akutsu, Hideyuki*; Niitsuma, Yasushi; Inoue, Takeshi; et al.

JAEA-Technology 2006-007, 24 Pages, 2006/03

JAEA-Technology-2006-007.pdf:1.81MB

Analysis of the uranyl nitrate solution fuel is carried out at the analytical laboratory of NUCEF(Nuclear Fuel Cycle Engineering Research Facility), which provides essential data for operation of STACY(Static Experiment Critical Facility), TRACY(Transient Experiment Critical Facility)and the fuel treatment system. Analyzed in FY 2004 were uranyl nitrate solution fuel samples taker before and after experiments of STACY and TRACY, samples for the preparation of uranyl nitrate solution fuel, and samples for nuclear material accountancy purpose. Also analyzed were the samples from raffinate treatment and its preliminary tests. The raffinate was generated, since FY 2000, during preliminary experiments on U/Pu extraction-pulification to fix the operation condition to prepare plutonium solution fuel to be used for criticality experiments at STACY. The total number of the samples analyzed in FY 2004 was 160. This report summarizes works related to the analysis and management of the analytical laboratory in the FY 2004.

JAEA Reports

Annual report on analytical works in NUCEF in FY. 2003

Shimizu, Kaori; Gunji, Kazuhiko*; Haga, Takahisa*; Fukaya, Hiroyuki; Sonoda, Takashi; Sakazume, Yoshinori; Sakai, Yutaka*; Akutsu, Hideyuki; Niitsuma, Yasushi*; Inoue, Takeshi; et al.

JAERI-Tech 2004-078, 27 Pages, 2005/02

JAERI-Tech-2004-078.pdf:1.84MB

Analysis of the uranyl nitrate solution fuel are carried out at the analytical laboratory, NUCEF (the Nuclear Fuel Cycle Engineering Research Facility), which provide essential data for the operations of STACY (the Static Experiment Critical Facility), TRACY (the Transient Experiment Critical Facility) and the fuel treatment system.In the FY 2003, analysis of the uranyl nitrate solution fuel from STACY/TRACY on its pre- and post-operations, analysis of the uranyl nitrate solution under preparation stage for the fuel and analysis for nuclear material accountancy purpose, have been conducted. In addition, analysis on the third U/Pu extraction/separation tests among the preliminary tests to confirm adjustment condition of plutonium solution fuel for its further use at STACY from 2000, and analysis on the experiments to treat extraction waste, were conducted. A total number of analytical samples in the FY 2003 were 156.This report summarizes works related to the analysis and management of the analytical laboratory in the FY 2003.

JAEA Reports

Annual report on analytical works in NUCEF in FY. 2002

Sakai, Yutaka; Gunji, Kazuhiko; Haga, Takahisa*; Fukaya, Hiroyuki; Sonoda, Takashi; Sakazume, Yoshinori; Akutsu, Hideyuki; Niitsuma, Yasushi; Shirahashi, Koichi; Sato, Takeshi

JAERI-Tech 2004-006, 25 Pages, 2004/02

JAERI-Tech-2004-006.pdf:1.72MB

Analyses of the uranyl nitrate solution fuel are carried out at the analytical laboratory, NUCEF (the Nuclear Fuel Cycle Engineering Research Facility), which provide essential data for the operations of STACY (the Static Experiment Critical Facility), TRACY (the Transient Experiment Critical Facility) and the fuel treatment system. In the FY 2002, analyses of the uranyl nitrate solution fuel from STACY/TRACY on its pre- and post-operations, analyses of the uranyl nitrate solution under preparation stage for the fuel and analyses for nuclear material accountancy purpose, have been conducted. In addition, analyses on the preliminary tests to confirm adjustment condition of plutonium solution fuel for its further use at STACY, and analyses on the americium extraction/separation tests to provide americium for the research on high temperature chemistry of TRU, were conducted. A total number of analytical samples in the FY 2002 were 275. This report summarizes works related to the analyses and management of the analytical laboratory in the FY 2002.

JAEA Reports

Present status of chemical analysis of uranyl nitrate solution used for the criticality experiments in NUCEF

Haga, Takahisa*; Gunji, Kazuhiko; Fukaya, Hiroyuki; Sonoda, Takashi; Sakazume, Yoshinori; Sakai, Yutaka; Niitsuma, Yasushi; Togashi, Yoshihiro; Miyauchi, Masakatsu; Sato, Takeshi; et al.

JAERI-Tech 2004-005, 54 Pages, 2004/02

JAERI-Tech-2004-005.pdf:2.06MB

Criticality experiments using uranyl nitrate solution fuel are being conducted at STACY (the Static Experiment Critical Facility) and TRACY (the Transient Experiment Critical Facility) in NUCEF (the Nuclear Fuel Cycle Safety Engineering Research Facility). Chemical analyses of the solution have been carried out to take necessary data for criticality experiments, for treatment and control of the fuel, and for safeguards purpose at the analytical laboratory placed in NUCEF. About 300 samples are analyzed annually that provide various kinds of data, such as uranium concentration, isolation acid concentration, uranium isotopic composition, concentration of fission product (FP) nuclides, tri-butyl phosphoric acid (TBP) concentration, impurities in the solution fuel and so on. This report summarizes the analytical methods and quality management of the analysis for uranyl nitrate solution relating to the criticality experiments.

JAEA Reports

Annual report on analytical works in NUCEF in FY. 2001

Sakazume, Yoshinori; Gunji, Kazuhiko; Haga, Takahisa*; Fukaya, Hiroyuki; Sonoda, Takashi; Sakai, Yutaka; Niitsuma, Yasushi; Shirahashi, Koichi; Sato, Takeshi

JAERI-Tech 2002-073, 25 Pages, 2002/09

JAERI-Tech-2002-073.pdf:2.51MB

Analytical results of uranyl nitrate solution are essential data for the operation of the Static Experiment Critical Facility (STACY), the Transient Experiment Critical Facility (TRACY) and the fuel treatment system in the Nuclear Fuel Cycle Safety Engineering Research Facility (NUCEF). Analytical works were carried out for the determination of fuel characteristics before and after criticality experiments, fuel preparation and nuclear material accountancy in FY. 2001. Moreover,as to preparation of critical experiments at STACY, plutonium preliminary tests were carried out to confirm the treatment condition (characteristics of the dissolution of the mixed oxide (MOX) powder and the extraction & separation for uranium / plutonium) of plutonium nitrate solution. Analytical works were carried out on the preliminary tests. A total number of analytical samples in FY. 2001 were 322 samples.This report summarizes the data on analytical works in FY.2001.

JAEA Reports

Annual report on analytical works in NUCEF in F.Y. 2000

Tanoue, Takahiro; Gunji, Kazuhiko; Haga, Takahisa*; Fukaya, Hiroyuki; Sonoda, Takashi; Sakazume, Yoshinori; Niitsuma, Yasushi; Miyauchi, Masakatsu; Shirahashi, Koichi; Sato, Takeshi

JAERI-Tech 2001-071, 30 Pages, 2001/11

JAERI-Tech-2001-071.pdf:4.15MB

Analytical results of uranyl nitrate solution are essential data for the operation of the Static Experiment Critical Facility (STACY), the Transient Experiment Critical Facility (TRACY) and the fuel treatment system in the Nuclear Fuel Cycle Safety Engineering Research Facility (NUCEF). Analytical works were carried out for the determination of fuel characteristics before and after criticality experiments, fuel preparation and nuclear material accountancy in FY. 2000. In accordance with handling and dissolution of mixed oxide(MOX) powder in the fuel treatment system of NUCEF ,the preliminary tests for dissolution of the MOX powder in nitric acid solution have started since the end of 2000 ,after the MOX powder transfer to the NUCEF. The analytical works were carried out for the preliminary tests. A total number of analytical samples in FY. 2000 were 483 samples . This report summarizes the data on analytical works in FY.2000.

JAEA Reports

Annual report on analysis work in NUCEF in fiscal year 1998

Togashi, Yoshihiro; Miyauchi, Masakatsu; Sonobe, Tamotsu; Niitsuma, Yasushi; Nakajima, Takayuki; Haga, Takahisa*; Tanoue, Takahiro; Fukaya, Hiroyuki; Sonoda, Takashi; Sakazume, Yoshinori; et al.

JAERI-Tech 2000-032, p.25 - 0, 2000/03

JAERI-Tech-2000-032.pdf:1.45MB

no abstracts in English

JAEA Reports

Analytical laboratory in NUCEF

Miyauchi, Masakatsu; ; Fukaya, Hiroyuki; Sakazume, Yoshinori; Sonoda, Takashi; ; ; Niitsuma, Yasushi; ; Okazaki, Shuji

JAERI-Tech 96-007, 98 Pages, 1996/02

JAERI-Tech-96-007.pdf:3.32MB

no abstracts in English

JAEA Reports

Development of image process system with personal computer

Niitsuma, Yasushi; Murao, Yoshio

JAERI-M 91-213, 73 Pages, 1992/01

JAERI-M-91-213.pdf:1.7MB

no abstracts in English

Oral presentation

Present status of Japanese tasks for lithium target facility under IFMIF/EVEDA

Nakamura, Kazuyuki; Ida, Mizuho; Kanemura, Takuji; Kondo, Hiroo; Niitsuma, Shigeto; Hirakawa, Yasushi; Furukawa, Tomohiro; Watanabe, Kazuyoshi; Horiike, Hiroshi; Terai, Takayuki*; et al.

no journal, , 

Three and half years has been passed from the start of IFMIF/EVEDA. In IFMIF/EVEDA, tasks for Lithium Target System consists of 5 validation tasks (LF1-5) and a design task (ED3), and are shared by Japan and Europe. Japan is covering the construction and operation of EVEDA Li Test Loop (LF1), diagnostics (LF2), purification system (LF4), remote handling system (LF5) and engineering design (ED3) with the contribution from universities. The present status of these tasks will be reported in the conference.

Oral presentation

Design and construction of IFMIF/EVEDA Li test loop

Kondo, Hiroo; Furukawa, Tomohiro; Hirakawa, Yasushi; Iuchi, Hiroshi; Tokoro, Daishiro*; Kanemura, Takuji; Ida, Mizuho; Watanabe, Kazuyoshi; Niitsuma, Shigeto; Wakai, Eiichi; et al.

no journal, , 

Engineering Validation and Engineering Design Activities (EVEDA) for the International Fusion Materials Irradiation Facility (IFMIF) were started from July 2007 under an international agreement called ITER Broader Approach. As a major Japanese activity, EVEDA Li test loop (ELTL) to simulate hydraulic and impurity conditions of IFMIF has already designed and is under construction, in which feasibility of hydraulic stability of the liquid Li target, the purification systems of hot traps are major key issues to be validated in this loop. This presentation focuses on the engineering design of the ELTL, and its construction and commissioning.

Oral presentation

Present status of Japanese tasks for lithium target facility under IFMIF/EVEDA, 1; Outline of activities

Nakamura, Kazuyuki; Ida, Mizuho; Kanemura, Takuji; Kondo, Hiroo; Niitsuma, Shigeto; Hirakawa, Yasushi; Furukawa, Tomohiro; Watanabe, Kazuyoshi; Horiike, Hiroshi*; Terai, Takayuki*; et al.

no journal, , 

I will present the outline and the status of the Japanese tasks for the Li Target system, which is ongoing now under the International Fusion Material Irradiation Facility (IFMIF)/Engineering Validation and Engineering Design Activities (EVEDA). The latest progresses are a completion of the EVEDA Li Loop, a fablication of the remote handling equipment and a repair from the damages caused by the earthquake.

Oral presentation

Construction and first operation of vacuum system for EVEDA Li test loop of International Fusion Materials Irradiation Facility (IFMIF)

Nakamura, Kazuyuki; Ida, Mizuho; Kanemura, Takuji; Kondo, Hiroo; Niitsuma, Shigeto; Hirakawa, Yasushi; Furukawa, Tomohiro; Watanabe, Kazuyoshi; Wakai, Eiichi

no journal, , 

EVEDA Li test loop, which is one of the major conponents for the development of the IFMIF, has been fabricated in Oarai Research Center. A detail of the fabrication and the first operation of the vacuum system, which is compatible with the high temperature and much liquid Li(300 $$^{circ}$$C, 2.5 ton), will be presented.

18 (Records 1-18 displayed on this page)
  • 1