Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 57

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

High-sensitive XANES analysis at Ce L$$_{2}$$-edge for Ce in bauxites using transition-edge sensors; Implications for Ti-rich geological samples

Li, W.*; Yamada, Shinya*; Hashimoto, Tadashi; Okumura, Takuma*; Hayakawa, Ryota*; Nitta, Kiyofumi*; Sekizawa, Oki*; Suga, Hiroki*; Uruga, Tomoya*; Ichinohe, Yuto*; et al.

Analytica Chimica Acta, 1240, p.340755_1 - 340755_9, 2023/02

 Times Cited Count:2 Percentile:31.9(Chemistry, Analytical)

no abstracts in English

Journal Articles

Tumor radioresistance caused by radiation-induced changes of stem-like cell content and sub-lethal damage repair capability

Fukui, Roman*; Saga, Ryo*; Matsuya, Yusuke; Tomita, Kazuo*; Kuwahara, Yoshikazu*; Ouchi, Kentaro*; Sato, Tomoaki*; Okumura, Kazuhiko*; Date, Hiroyuki*; Fukumoto, Manabu*; et al.

Scientific Reports (Internet), 12(1), p.1056_1 - 1056_12, 2022/01

 Times Cited Count:10 Percentile:91.34(Multidisciplinary Sciences)

Alive cancer cells after fractionated irradiations with 2 Gy X-rays per day for more than 30 days show clinically relevant radioresistant. Such radioresistance is experimentally interpreted to attributed to the increment of stem-like cell content. However, only an experimental approach cannot clarify the cell responses (DNA damage and cell death induction) of cancer stem cells, so the radioresistant mechanisms remain uncertain. In addition to the conventional cell experiments using radio-resistant cell lines established after fractionated irradiations, in this study we developed a mathematical model (so called integrated microdosimetric-kinetic (IMK) model) explicitly considering cancer stem-like cell content and DNA damage responses and investigated radioresistant mechanisms acquired after fractionated irradiations. The IMK model analysis suggested that the changes of stem-like cell fraction and DNA repair efficiency play important roles of radioresisitance acquired after irradiations. Considering these into the IMK model, we successfully reproduced the experimental survival of various cell lines and various irradiation conditions. This work would contribute to not only the precise understanding of the radioresistant mechanisms induced after irradiation but also predicting curative effects with high precision.

Journal Articles

Dynamical response of transition-edge sensor microcalorimeters to a pulsed charged-particle beam

Okumura, Takuma*; Azuma, Toshiyuki*; Bennet, D. A.*; Caradonna, P.*; Chiu, I.-H.*; Doriese, W. B.*; Durkin, M. S.*; Fowler, J. W.*; Gard, J. D.*; Hashimoto, Tadashi; et al.

IEEE Transactions on Applied Superconductivity, 31(5), p.2101704_1 - 2101704_4, 2021/08

 Times Cited Count:1 Percentile:11.15(Engineering, Electrical & Electronic)

A superconducting transition-edge sensor (TES) microcalorimeter is an ideal X-ray detector for experiments at accelerator facilities because of good energy resolution and high efficiency. To study the performance of the TES detector with a high-intensity pulsed charged-particle beam, we measured X-ray spectra with a pulsed muon beam at the Japan Proton Accelerator Research Complex (J-PARC) in Japan. We found substantial temporal shifts of the X-ray energy correlated with the arrival time of the pulsed muon beam, which was reasonably explained by pulse pileup due to the incidence of energetic particles from the initial pulsed beam.

Journal Articles

Deexcitation dynamics of muonic atoms revealed by high-precision spectroscopy of electronic $$K$$ X rays

Okumura, Takuma*; Azuma, Toshiyuki*; Bennet, D. A.*; Caradonna, P.*; Chiu, I. H.*; Doriese, W. B.*; Durkin, M. S.*; Fowler, J. W.*; Gard, J. D.*; Hashimoto, Tadashi; et al.

Physical Review Letters, 127(5), p.053001_1 - 053001_7, 2021/07

 Times Cited Count:13 Percentile:79.44(Physics, Multidisciplinary)

We observed electronic $$K$$X rays emitted from muonic iron atoms using a superconducting transition-edge-type sensor microcalorimeter. The energy resolution of 5.2 eV in FWHM allowed us to observe the asymmetric broad profile of the electronic characteristic $$K$$$$alpha$$ and $$K$$$$beta$$ X rays together with the hypersatellite $$K$$$$alpha$$ X rays around 6 keV. This signature reflects the time-dependent screening of the nuclear charge by the negative muon and the $$L$$-shell electrons, accompanied by electron side-feeding. Assisted by a simulation, this data clearly reveals the electronic $$K$$- and $$L$$-shell hole production and their temporal evolution during the muon cascade process.

Journal Articles

Commissioning of Versatile Compact Neutron Diffractometer (VCND) at the B-3 beam port of Kyoto University Research Reactor (KUR)

Mori, Kazuhiro*; Okumura, Ryo*; Yoshino, Hirofumi*; Kanayama, Masaya*; Sato, Setsuo*; Oba, Yojiro; Iwase, Kenji*; Hiraka, Haruhiro*; Hino, Masahiro*; Sano, Tadafumi*; et al.

JPS Conference Proceedings (Internet), 33, p.011093_1 - 011093_6, 2021/03

no abstracts in English

Journal Articles

Analyses of $$H$$*(10) dose rates measured in environment contaminated by radioactive caesium; Correction of directional dependence of scintillation detectors

Tsuda, Shuichi; Tanigaki, Minoru*; Yoshida, Tadayoshi; Okumura, Ryo*; Saito, Kimiaki

Radiation Protection Dosimetry, 193(3-4), p.228 - 236, 2021/03

AA2020-0760.pdf:0.87MB

 Times Cited Count:3 Percentile:31.78(Environmental Sciences)

Environmental dose rate monitoring has been performed with various scintillation detectors since the Fukushima Dai-ichi Nuclear Power Plant accident. Gamma-rays from caesium isotopes deposited in soil enter radiation detectors in any direction, but directional dependence of the detectors used for dose rate measurements are not always uniform and the dose rates vary even if measurement takes place at the same place. To investigate the influence of crystal configurations on dose rate, dose rate measurements using several scintillation detectors with different crystal configurations were conducted. By measuring pulse height spectra and multiplying them with spectrum - dose conversion operators (G(E) function), dose rates were deduced and compared. It was found that the dose rates varied within approximately 25% among six detectors. To reduce the differences, the dose rate using G(E) functions determined in rotational geometry were obtained and applied instead. The revised dose rates agreed with one another within uncertainties, but this was not the case of scintillation detector with flat crystal shape, and it means this method could not compensate its strong directional dependence. These experimental results reveal that detectors with superior directional characteristics should be used for environmental dose rate measurement since the compensation of directional dependence using a G(E) function determined in rotational geometry is not always available.

Journal Articles

Dependence of dose rate measurement in the environment on crystal configuration of scintillation detectors

Tsuda, Shuichi; Tanigaki, Minoru*; Yoshida, Tadayoshi; Okumura, Ryo*; Saito, Kimiaki

Nihon Genshiryoku Gakkai Wabun Rombunshi, 17(1), p.11 - 17, 2018/03

Environmental dose rate monitoring has been performed using scintillation detectors since the Fukushima Dai-ichi Nuclear Power Plant accident happened. After the accident, various scintillation detectors with directional dependence are used in the measurement, though detectors with superior directional dependence are needed because photons come from various direction in the environment. To investigate the influence of crystal configurations on indicated values of dose rates, pulse height spectra were measured using scintillation-based detectors with different crystal configurations and ambient dose rates were obtained using a spectrum - dose conversion operator (G(E) function). It is found that the dose rate for a rectangular-parallelepiped crystal is $$sim$$ 40% than that for a cylindrical one at the maximum. However, the values agreed within 10% among all the detectors irrespective of the crystal shapes, using G(E) functions determined in a rotational irradiation geometry.

Journal Articles

Operation and commissioning of IFMIF (International Fusion Materials Irradiation Facility) LIPAc injector

Okumura, Yoshikazu; Gobin, R.*; Knaster, J.*; Heidinger, R.*; Ayala, J.-M.*; Bolzon, B.*; Cara, P.*; Chauvin, N.*; Chel, S.*; Gex, D.*; et al.

Review of Scientific Instruments, 87(2), p.02A739_1 - 02A739_3, 2016/02

 Times Cited Count:7 Percentile:35.23(Instruments & Instrumentation)

IFMIF is an accelerator based neutron facility having two set of linear accelerators each producing 125mA/CW deuterium ion beams (250mA in total) at 40MeV. The LIPAc (Linear IFMIF Prototype Accelerator) being developed in the IFMIF-EVEDA project consists of an injector, a RFQ accelerator, and a part of superconducting Linac, whose target is to demonstrate 125mA/CW deuterium ion beam acceleration up to 9MeV. The injector has been developed in CEA Saclay and already demonstrated 140mA/100keV deuterium beam. The injector was disassembled and delivered to the International Fusion Energy Research Center (IFERC) in Rokkasho, Japan, and the commissioning has started after its reassembly 2014; the first beam production has been achieved in November 2014. Up to now, 100keV/120mA/CW hydrogen ion beam has been produced with a low beam emittance of 0.2 $$pi$$.mm.mrad (rms, normalized).

Journal Articles

Measurement of ion species in high current ECR H$$^+$$/D$$^+$$ ion source for IFMIF (International Fusion Materials Irradiation Facility)

Shinto, Katsuhiro; Sen$'e$e, F.*; Ayala, J.-M.*; Bolzon, B.*; Chauvin, N.*; Gobin, R.*; Ichimiya, Ryo; Ihara, Akira; Ikeda, Yukiharu; Kasugai, Atsushi; et al.

Review of Scientific Instruments, 87(2), p.02A727_1 - 02A727_3, 2016/02

 Times Cited Count:8 Percentile:39.15(Instruments & Instrumentation)

Journal Articles

Progress of the high current Prototype Accelerator for IFMIF/EVEDA

Okumura, Yoshikazu; Ayala, J.-M.*; Bolzon, B.*; Cara, P.*; Chauvin, N.*; Chel, S.*; Gex, D.*; Gobin, R.*; Harrault, F.*; Heidinger, R.*; et al.

Proceedings of 12th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.203 - 205, 2015/09

Under the framework of Broader Approach (BA) agreement between Japan and Euratom, IFMIF/EVEDA project was launched in 2007 to validate the key technologies to realize IFMIF. The most crucial technology to realize IFMIF is two set of linear accelerator each producing 125mA/CW deuterium ion beams up to 40MeV. The prototype accelerator, whose target is 125mA/CW deuterium ion beam acceleration up to 9MeV, is being developed in International Fusion Research Energy Center (IFERC) in Rokkasho, Japan. The injector developed in CEA Saclay was delivered in Rokkasho in 2014, and is under commissioning. Up to now, 100keV/120mA/CW hydrogen ion beams and 100keV/90mA/CW duty deuterium ion beams are successfully produced with a low beam emittance of 0.21 $$pi$$.mm.mrad (rms, normalized). Delivery of RFQ components will start in 2015, followed by the installation of RF power supplies in 2015.

Journal Articles

Measurements and evaluations of air dose rates around Fukushima, 4; Practical aspects of air dose rate measurements in the environment

Tsuda, Shuichi; Yoshida, Tadayoshi; Ando, Masaki; Matsuda, Norihiro; Mikami, Satoshi; Tanigaki, Minoru*; Okumura, Ryo*; Takamiya, Koichi*; Sato, Nobuhiro*; Seki, Akiyuki; et al.

Radioisotopes, 64(4), p.275 - 289, 2015/04

This article provides practically useful information on air dose rate measurements in the environments. The basic requirements for the accurate measurements are described giving actual data. The characteristics and some measured results are shown for reliable methods which are widely used in the environmental radiation measurements. Further, information is given on internet sites where air dose rates and related data obtained by official organizations can be browsed.

Journal Articles

Measurement of air dose rates over a wide area around the Fukushima Dai-ichi Nuclear Power Plant through a series of car-borne surveys

Ando, Masaki; Nakahara, Yukio; Tsuda, Shuichi; Yoshida, Tadayoshi; Matsuda, Norihiro; Takahashi, Fumiaki; Mikami, Satoshi; Kinouchi, Nobuyuki; Sato, Tetsuro*; Tanigaki, Minoru*; et al.

Journal of Environmental Radioactivity, 139, p.266 - 280, 2015/01

 Times Cited Count:52 Percentile:82.76(Environmental Sciences)

A series of car-borne surveys using the KURAMA and KURAMA-II systems was conducted in a wide area in eastern Japan from June 2011 to December 2012 to evaluate the distribution of air dose rates around the Fukushima Dai-ichi Nuclear Power Plant, and to determine the time-dependent trend of decrease in air dose rates. An automated data processing system was established, which enables analyses of large amounts of data obtained with the use of about 100 units of the measurement system in a short time. The initial data for studying the migration status of radioactive cesium was obtained in the first survey, followed by the other car-borne surveys having wider measurement ranges. Comparing the measured air dose rates obtained in each survey, it was found that the decreasing trend of air dose rates measured through car-borne surveys was larger than that expected from the physical decay of radioactive cesium and that measured using NaI (Tl) survey meters around the road.

Journal Articles

C-face interface defects in 4H-SiC MOSFETs studied by electrically detected magnetic resonance

Umeda, Takahide*; Okamoto, Mitsuo*; Arai, Ryo*; Sato, Yoshihiro*; Kosugi, Ryoji*; Harada, Shinsuke*; Okumura, Hajime*; Makino, Takahiro; Oshima, Takeshi

Materials Science Forum, 778-780, p.414 - 417, 2014/02

 Times Cited Count:2 Percentile:72.7(Crystallography)

Interface defects of Metal-Oxide-Semiconductors (MOSFETs) fabricated on Carbone (C) face 4H-SiC were investigated by Electrically Detected Magnet Resistance (EDMR). Gate oxide of the MOSFETs was formed by either wet-oxidation and H$$_{2}$$ annealing or dry-oxidation. The values of channel mobility for MOSFETS with wet gate oxide and dry gate oxide are less than 1 and 90 cm$$^{2}$$/Vs, respectively. By EDMR measurement under low temperature (less than 20 K), EDMR signals related to C were detected. The peak height of the signals increased with increasing $$gamma$$-ray doses, and the channel mobility decreased. From this result, it is assumed that hydrogen atoms passivating C dangling bonds are released by $$gamma$$-rays and the channel mobility decreases with increasing the C related defects.

JAEA Reports

Construction of a car-borne survey system for measurement of dose rates in air; KURAMA-II, and its application

Tsuda, Shuichi; Yoshida, Tadayoshi; Nakahara, Yukio; Sato, Tetsuro; Seki, Akiyuki; Matsuda, Norihiro; Ando, Masaki; Takemiya, Hiroshi; Tanigaki, Minoru*; Takamiya, Koichi*; et al.

JAEA-Technology 2013-037, 54 Pages, 2013/10

JAEA-Technology-2013-037.pdf:4.94MB

JAEA has been performing dose rate mapping in air using a car-borne survey system KURAMA-II. The KURAMA system is a GPS-aided mobile radiation monitoring system that has been newly developed by Kyoto University Research Reactor Institute in response to the nuclear disaster. The KURAMA system is composed of an energy-compensated scintillation survey meter for measuring dose rate, electric device for controlling both the dose rates and the position data from a GPS module, a computer server for processing and analyzing data from KURAMA, and client PCs for providing for end users. The KURAMA-II has been improved in small-packaging, durability, and automated data transmission. In consequence, dose rate mapping in wide area has become possible in shorter period of time. This report describes the construction of KURAMA-II, its application and a suggestion of how to manage a large number of KURAMA-II.

Journal Articles

Actinide-handling experience for training and education of future expert under J-ACTINET

Osaka, Masahiko; Konashi, Kenji*; Hayashi, Hirokazu; Li, D.*; Homma, Yoshiya*; Yamamura, Tomoo*; Sato, Isamu; Miwa, Shuhei; Sekimoto, Shun*; Kubota, Takumi*; et al.

Proceedings of International Conference on Toward and Over the Fukushima Daiichi Accident (GLOBAL 2011) (CD-ROM), 5 Pages, 2011/12

Summer schools for future experts have successfully been completed under Japan Actinide Network (J-ACTINET) for the purpose of development of human resources who are expected to be engaged in every areas of actinide-research/engineering. The first summer school was held in Ibaraki-area in August 2009, followed by the second one in Kansai-area in August 2010. Two summer schools have focused on actual experiences of actinides in actinide-research fields for university students and young researchers/engineers as an introductory course of actinide-researches. Several quasi actinide-handling experiences at the actinide-research fields have attracted attentions of participants at the first school in Ibaraki-area. The actual experiments using actinides-containing solutions have been carried out at the second school in Kansai-area. Future summer schools will be held every year for the sustainable human resource development in various actinide-research fields.

Journal Articles

Ground-state properties of the one-dimensional attractive Hubbard model with confinement; A Comparative study

Hu, J.-H.*; Wang, J.-J.*; Xianlong, G.*; Okumura, Masahiko*; Igarashi, Ryo; Yamada, Susumu; Machida, Masahiko

Physical Review B, 82(1), p.014202_1 - 014202_12, 2010/07

 Times Cited Count:17 Percentile:58.6(Materials Science, Multidisciplinary)

We revisit the one-dimensional attractive Hubbard model by using the Bethe-ansatz-based density-functional theory and density-matrix renormalization method. The ground-state properties of this model are discussed in details for different fillings and different confining conditions in weak-to-intermediate coupling regime. We investigate the ground-state energy, energy gap, and pair-binding energy and compare them with those calculated from the canonical Bardeen-Cooper-Schrieffer approximation. We find that the Bethe-ansatz-based density-functional theory is computationally easy and yields an accurate description of the ground-state properties for weak-to-intermediate interaction strength, different fillings, and confinements.

Journal Articles

Research and development of highly-accurate simulation for quantum many-body systems; Parallel-computing of density matrix renormalization group method and ultra large-scale simulations

Yamada, Susumu; Igarashi, Ryo; Okumura, Masahiko*; Imamura, Toshiyuki*; Machida, Masahiko

Oyo Suri, 20(2), p.132 - 147, 2010/06

The density matrix renormalization group (DMRG) method is a numerical calculation technique to obtain the ground state of quantum lattice systems whose degree of freedoms exponentially grows with the size of the lattice sites and particles (or spins in interacting spin systems). Its advantage is excellent accuracy comparable to the exact diagonalization scheme even in considerably large number of sites and particles (spins). However, the technique has been originally developed for one-dimensional systems. Therefore, the extension to higher dimensional lattices systems is in great demand since major rich physics such as superconductivity and ferromagnetism frequently occurs in two or three dimensions. This paper describes a parallelization strategy of the technique to calculate quasi-two dimensional (ladder) systems toward the next generation supercomputer and reports its good parallel efficiency on T2K supercomputer HA8000 at University of Tokyo. Moreover, typical quantum phenomena obtained by using the parallelized code are exhibited and some remarks on parallelization scheme in the next generation supercomputer are mentioned.

Journal Articles

Isoscalar giant resonances in the Sn nuclei and implications for the asymmetry term in the nuclear-matter incompressibility

Li, T.*; Garg, U.*; Liu, Y.*; Marks, R.*; Nayak, B. K.*; Madhusudhana Rao, P. V.*; Fujiwara, Mamoru*; Hashimoto, Hisanobu*; Nakanishi, Kosuke*; Okumura, Shun*; et al.

Physical Review C, 81(3), p.034309_1 - 034309_11, 2010/03

 Times Cited Count:107 Percentile:97.48(Physics, Nuclear)

Journal Articles

Beam performance of negative-ion based NBI system for JT-60

Ito, Takao; Akino, Noboru; Ebisawa, Noboru; Grisham, L. R.*; Honda, Atsushi; Hu, L.*; Kawai, Mikito; Kazawa, Minoru; Kuriyama, Masaaki; Kusaka, Makoto*; et al.

Fusion Engineering and Design, 51-52, p.1039 - 1047, 2000/11

 Times Cited Count:15 Percentile:68.65(Nuclear Science & Technology)

no abstracts in English

Journal Articles

Power flow in the negative-ion based neutral beam injection for JT-60

Kuriyama, Masaaki; Akino, Noboru; Ebisawa, Noboru; Grisham, L. R.*; Hikida, Shigenori*; Honda, Atsushi; Ito, Takao; Kawai, Mikito; Kazawa, Minoru; Kusaka, Makoto*; et al.

Review of Scientific Instruments, 71(2), p.751 - 754, 2000/02

 Times Cited Count:21 Percentile:72.69(Instruments & Instrumentation)

no abstracts in English

57 (Records 1-20 displayed on this page)