Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Nagai, Takayuki; Okamoto, Yoshihiro; Yamagishi, Hirona*; Shibata, Daisuke*; Kojima, Kazuo*; Hasegawa, Takehiko*; Sato, Seiichi*; Fukaya, Akane*; Hatakeyama, Kiyoshi*
JAEA-Research 2023-004, 45 Pages, 2023/09
The local structure of glass-forming elements and waste elements in borosilicate glasses varies with its chemical composition. In this study, simulated waste glass samples were prepared and the chemical state regarding boron (B), silicon (Si) and waste elements of iron (Fe), cesium (Cs) were estimated by using XAFS measurement in soft X-ray region. To understand the chemical stability of simulated waste glasses, XANES spectra of B K-edge, Fe L, L-edge, and Cs M, M-edge were measured on the glass surface exposed to the leachate. As a result, it was found that the glass surface exposed to the leachate was changed and it was difficult to obtain a clear XANES spectrum. From the B K-edge XANES spectra on glass surfaces exposed to the leachate, an increase in three-coordination of B-O (BO) and a decrease in four-coordination of B-O (BO) were observed compared to the glass surfaces before immersion. The XANES spectra of Fe L, L-edge, and Cs M, M-edge show that as the exposure time in the leachate increases, the Cs present on the glass surface dissolves into the leachate. The XANES spectra of Si K-edge were measured on simulated waste glass surfaces before immersion, and it was confirmed that the change in XANES spectra given by NaO concentration had a larger effect than the waste component concentration.
Tachi, Yukio; Sato, Tomofumi*; Akagi, Yosuke*; Kawamura, Makoto*; Nakane, Hideji*; Terashima, Motoki; Fujiwara, Kenso; Iijima, Kazuki
Science of the Total Environment, 724, p.138098_1 - 138098_11, 2020/07
Times Cited Count:13 Percentile:57.17(Environmental Sciences)To understand and predict radiocesium transport behaviors in the environment, highly contaminated sediments from Ukedo and Odaka rivers around the Fukushima Daiichi Nuclear Power Plant were investigated systematically focusing on key factors controlling radiocesium sorption and fixation, including particle size, clay mineralogy and organic matter.
Theis, C.*; Carbonez, P.*; Feldbaumer, E.*; Forkel-Wirth, D.*; Jaegerhofer, L.*; Pangallo, M.*; Perrin, D.*; Urscheler, C.*; Roesler, S.*; Vincke, H.*; et al.
EPJ Web of Conferences, 153, p.08018_1 - 08018_5, 2017/09
Times Cited Count:0 Percentile:0.03(Nuclear Science & Technology)At CERN, gas-filled ionization chambers PTW-34031 (PMI) are commonly used in radiation fields including neutrons, protons and -rays. A response function for each particle is calculated by the radiation transport code FLUKA. To validate a response function to high energy neutrons, benchmark experiments with quasi mono-energetic neutrons have been carried out at RCNP, Osaka University. For neutron irradiation with energies below 200 MeV, very good agreement was found comparing the FLUKA simulations and the measurements. In addition it was found that at proton energies of 250 and 392 MeV, results calculated with neutron sources underestimate the experimental data due to a non-negligible gamma component originating from the target Li(p,n)Be reaction.
Masuda, Akihiko*; Matsumoto, Tetsuro*; Iwamoto, Yosuke; Hagiwara, Masayuki*; Satoh, Daiki; Sato, Tatsuhiko; Iwase, Hiroshi*; Yashima, Hiroshi*; Nakane, Yoshihiro; Nishiyama, Jun*; et al.
Nuclear Instruments and Methods in Physics Research A, 849, p.94 - 101, 2017/03
Times Cited Count:1 Percentile:10.62(Instruments & Instrumentation)Quasi-monoenergetic high-energy neutron fields induced by Li(p,n) reactions are used for the response evaluation of neutron-sensitive devices. The quasi-monoenergetic high-energy field consists of high-energy monoenergetic peak neutrons and unwanted continuum neutrons down to the low-energy region. A two-angle differential method has been developed to compensate for the effect of the continuum neutrons in the response measurements. In this study, the two-angle differential method was demonstrated for Bonner sphere detectors, which are typical examples of moderator-based neutron-sensitive detectors, to investigate the method's applicability and its dependence on detector characteristics. Through this study, the adequacy of the two-angle differential method was experimentally verified, and practical suggestions were made pertaining to this method.
Koka, Masashi; Ishii, Yasuyuki; Yamada, Naoto; Okubo, Takeru; Kada, Wataru*; Kitamura, Akane; Iwata, Yoshihiro*; Kamiya, Tomihiro; Sato, Takahiro
JAEA-Technology 2016-006, 41 Pages, 2016/03
A MeV-class light ion microbeam system has been developed for micro-analysis and micro-fabrication with high spatial resolution at 3-MV single-ended accelerator in Takasaki Ion Accelerators for Advanced Radiation Application of Takasaki Advanced Radiation Research Institute, Sector of Nuclear Science Research, Japan Atomic Energy Agency. This report describes the technical improvements for the main apparatus (the accelerator, beam-transport lines, and microbeam system), and auxiliary equipments/ parts for ion beam applications such as Particle Induced X-ray/Gamma-ray Emission (PIXE/PIGE) analysis, 3-D element distribution analysis using PIXE-Computed Tomography(CT), Ion Beam-Induced Luminescence (IBIL) analysis, and Proton Beam Writing with the microbeam scanning, with functional outline of these apparatus and equipments/parts.
Sato, Takahiro; Yokoyama, Akihito; Kitamura, Akane; Okubo, Takeru; Ishii, Yasuyuki; Takahatake, Yoko; Watanabe, So; Koma, Yoshikazu; Kada, Wataru*
Nuclear Instruments and Methods in Physics Research B, 371, p.419 - 423, 2016/03
Times Cited Count:7 Percentile:55.03(Instruments & Instrumentation)Usui, Aya; Chiba, Atsuya; Yamada, Keisuke; Yokoyama, Akihito; Kitano, Toshihiko*; Takayama, Terumitsu*; Orimo, Takao*; Kanai, Shinji*; Aoki, Yuki*; Hashizume, Masashi*; et al.
Dai-28-Kai Tandemu Kasokuki Oyobi Sono Shuhen Gijutsu No Kenkyukai Hokokushu, p.117 - 119, 2015/12
no abstracts in English
Yuyama, Takahiro; Ishibori, Ikuo; Kurashima, Satoshi; Yoshida, Kenichi; Ishizaka, Tomohisa; Chiba, Atsuya; Yamada, Keisuke; Yokoyama, Akihito; Usui, Aya; Miyawaki, Nobumasa; et al.
Proceedings of 12th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.302 - 304, 2015/09
no abstracts in English
Nakane, Yoshihiro; Hagiwara, Masayuki*; Iwamoto, Yosuke; Iwase, Hiroshi*; Satoh, Daiki; Sato, Tatsuhiko; Yashima, Hiroshi*; Matsumoto, Tetsuro*; Masuda, Akihiko*; Nunomiya, Tomoya*; et al.
Progress in Nuclear Science and Technology (Internet), 4, p.704 - 708, 2014/04
no abstracts in English
Kitamura, Akane; Sato, Takahiro; Koka, Masashi; Kamiya, Tomihiro; Kobayashi, Tomohiro*
Nuclear Instruments and Methods in Physics Research B, 314, p.82 - 85, 2013/11
Times Cited Count:7 Percentile:49.28(Instruments & Instrumentation)Kitamura, Akane; Sato, Takahiro; Koka, Masashi; Kobayashi, Tomohiro*; Kamiya, Tomihiro
Nuclear Instruments and Methods in Physics Research B, 306, p.288 - 291, 2013/07
Times Cited Count:8 Percentile:53.52(Instruments & Instrumentation)Kitamura, Akane; Sato, Takahiro; Koka, Masashi; Kobayashi, Tomohiro*; Kamiya, Tomihiro
Nuclear Instruments and Methods in Physics Research B, 307, p.610 - 613, 2013/07
Times Cited Count:6 Percentile:44.02(Instruments & Instrumentation)Kitamura, Akane; Kobayashi, Tomohiro*; Sato, Takahiro; Koka, Masashi; Kamiya, Tomihiro; Suzuki, Akihiro*; Terai, Takayuki*
Nuclear Instruments and Methods in Physics Research B, 307, p.614 - 617, 2013/07
Times Cited Count:7 Percentile:49.28(Instruments & Instrumentation)Kitamura, Akane; Sato, Takahiro; Koka, Masashi; Kobayashi, Tomohiro*; Kamiya, Tomihiro
Hoshasen To Sangyo, (134), p.37 - 40, 2013/06
no abstracts in English
Kitamura, Akane; Sato, Takahiro; Koka, Masashi; Kamiya, Tomihiro; Kobayashi, Tomohiro*
Transactions of the Materials Research Society of Japan, 38(1), p.101 - 104, 2013/03
Kitamura, Akane; Sato, Takahiro; Koka, Masashi; Kamiya, Tomihiro; Kobayashi, Tomohiro*
JAEA-Review 2012-046, JAEA Takasaki Annual Report 2011, P. 128, 2013/01
Kitamura, Akane; Sato, Takahiro; Koka, Masashi; Kamiya, Tomihiro; Kobayashi, Tomohiro*
Transactions of the Materials Research Society of Japan, 37(2), p.219 - 222, 2012/06
Masuda, Akihiko*; Matsumoto, Tetsuro*; Harano, Hideki*; Nishiyama, Jun*; Iwamoto, Yosuke; Hagiwara, Masayuki*; Satoh, Daiki; Iwase, Hiroshi*; Yashima, Hiroshi*; Nakamura, Takashi*; et al.
IEEE Transactions on Nuclear Science, 59(1), p.161 - 166, 2012/02
Times Cited Count:12 Percentile:66.54(Engineering, Electrical & Electronic)In this study, responses of Bonner sphere spectrometer (BSS) for 245 and 388 MeV neutrons was measured at RCNP, Osaka University. The neutrons are generated in the Li(p,n) reaction and its spectra consist of a high-energy peak and a continuum down to the low energy. Therefore, the observed counts of BSS caused by the continuum need to be subtracted. Adjusting a Li target angle and a collimator position, 0 deg and 30 deg component of generated neutron are available. While the 0 deg component contains both the peak and the continuum, the 30 deg component is considered to contain only the continuum. Therefore, the response of the peak is obtained. The spectra were measured using the time-of-flight (TOF) method with a NE213 scintillator.
Iwamoto, Yosuke; Hagiwara, Masayuki*; Satoh, Daiki; Iwase, Hiroshi*; Yashima, Hiroshi*; Itoga, Toshiro*; Sato, Tatsuhiko; Nakane, Yoshihiro; Nakashima, Hiroshi; Sakamoto, Yukio; et al.
Proceedings of 10th Meeting of the Task Force on Shielding Aspects of Accelerators, Targets and Irradiation Facilities (SATIF-10), p.53 - 61, 2011/03
The neutron energy spectra penetrating 10 to 100 cm thick iron and 25 to 200 cm thick concrete shields have been measured using 138, 243 and 387 MeV quasi-monoenergetic neutron sources at the Research Center for Nuclear Physics (RCNP) facility, Osaka University. The source neutrons were produced from a 1 cm thick lithium target bombarded with 140, 245 and 388 MeV protons. Two types of NE213 liquid organic scintillators and Bonner ball neutron spectrometers were used for the neutron energy spectrum measurement. The TOF and unfolding methods were applied to estimate the energy spectra behind the shield in the peak energy region and continuous energy region, respectively. We have also measured the neutron energy spectra and angular distribution of the source neutron above 1 MeV in the angular range from 0 to 30 with the TOF method. All measured data were compared with the PHITS Monte Carlo calculations.
Iwamoto, Yosuke; Hagiwara, Masayuki*; Satoh, Daiki; Iwase, Hiroshi*; Yashima, Hiroshi*; Itoga, Toshiro*; Sato, Tatsuhiko; Nakane, Yoshihiro; Nakashima, Hiroshi; Sakamoto, Yukio; et al.
Nuclear Instruments and Methods in Physics Research A, 629(1), p.43 - 49, 2011/02
Times Cited Count:21 Percentile:82.72(Instruments & Instrumentation)The authors measured the neutron energy spectra of a quasi-monoenergetic Li(p,n) neutron source with 246 and 389 MeV protons set at seven angles (0, 2.5, 5, 10, 15, 20 and 30), using a time-of-flight (TOF) method employing organic scintillators NE213 at the Research Center for Nuclear Physics (RCNP) of Osaka University. The energy spectra of the source neutrons were precisely deduced down to 2 MeV at 0 and 10 MeV at other angles. The cross sections of the peak neutron production reaction at 0 were on the 35-40 mb line of other experimental data, and the peak neutron angular distribution agreed well with the Taddeucci formula. Neutron energy spectra below 100 MeV at all angles were comparable, but the shapes of the continuum above 150 MeV changed considerably with the angle.