Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Kaburagi, Masaaki; Shimazoe, Kenji*; Kato, Masahiro*; Kurosawa, Tadahiro*; Kamada, Kei*; Kim, K. J.*; Yoshino, Masao*; Shoji, Yasuhiro*; Yoshikawa, Akira*; Takahashi, Hiroyuki*
Nuclear Instruments and Methods in Physics Research A, 1010, p.165544_1 - 165544_9, 2021/09
Times Cited Count:0 Percentile:0.02(Instruments & Instrumentation)The number of nuclear facilities being decommissioned has been increasing worldwide, in particular following the accident of the Tokyo Electric Power Company Holdings' Fukushima Daiichi Nuclear Power Station in 2011. In these nuclear facilities, proper management of radioactive materials is required. Then, A -ray spectrometer with four segmentations using small volume CeBr scintillators with a dimension of was developed. The four scintillators were coupled to a multi-anode photomultiplier tube specific to intense radiation fields. We performed the -ray exposure study under Cs and Co radiation fields. Under the Cs radiation field, the relative energy resolution at 1375 mSv/h was the relative energy resolution at 1375 mSv/h was 9.20.05%, 8.00.08%, 8.00.03%, and 9.00.04% for the four channels, respectively.
Kaburagi, Masaaki; Shimazoe, Kenji*; Kato, Masahiro*; Kurosawa, Tadahiro*; Kamada, Kei*; Kim, K. J.*; Yoshino, Masao*; Shoji, Yasuhiro*; Yoshikawa, Akira*; Takahashi, Hiroyuki*; et al.
Nuclear Instruments and Methods in Physics Research A, 988, p.164900_1 - 164900_8, 2021/02
Times Cited Count:11 Percentile:89.29(Instruments & Instrumentation)An increasing number of nuclear facilities have been decommissioned worldwide following the 2011 accident of the TEPCO' Fukushima Daiichi Nuclear Power Station. During the decommissioning, radioactive materials have to be retrieved under proper management. In this study, a small cubic CeBr spectrometer with dimensions of 5 mm 5 mm 5 mm was manufactured to perform -ray spectroscopy under intense -ray fields. Furthermore, thanks to a fast digital process unit and a customized photomultiplier, the device could perform -ray spectroscopy at dose rates of over 1 Sv/h. The energy resolution (FWHM) at 662 keV ranged from 4.4% at 22 mSv/h to 5.2% at 1407 mSv/h for a Cs radiation field. Correspondingly, at 1333 keV, it ranged from 3.1% at 26 mSv/h to 4.2% at 2221 mSv/h for a Co radiation field, which suggested to realize -ray assessment of Cs, Cs, Co, and Eu at dose rates of over 1 Sv/h.
Kaburagi, Masaaki; Shimazoe, Kenji*; Otaka, Yutaka*; Uenomachi, Mizuki*; Kamada, Kei*; Kim, K. J.*; Yoshino, Masao*; Shoji, Yasuhiro*; Yoshikawa, Akira*; Takahashi, Hiroyuki*; et al.
Nuclear Instruments and Methods in Physics Research A, 971, p.164118_1 - 164118_8, 2020/08
Times Cited Count:7 Percentile:66.68(Instruments & Instrumentation)Adare, A.*; Afanasiev, S.*; Aidala, C.*; Ajitanand, N. N.*; Akiba, Y.*; Al-Bataineh, H.*; Alexander, J.*; Aoki, K.*; Aphecetche, L.*; Armendariz, R.*; et al.
Physical Review D, 84(1), p.012006_1 - 012006_18, 2011/07
Times Cited Count:29 Percentile:72.31(Astronomy & Astrophysics)We report on the event structure and double helicity asymmetry () of jet production in longitudinally polarized collisions at = 200 GeV. Photons and charged particles were measured by the PHENIX experiment. Event structure was compared with the results from PYTHIA event generator. The production rate of reconstructed jets is satisfactorily reproduced with the next-to-leading-order perturbative QCD calculation. We measured = -0.0014 0.0037 at the lowest bin and -0.0181 0.0282 at the highest bin. The measured is compared with the predictions that assume various distributions.
Adare, A.*; Afanasiev, S.*; Aidala, C.*; Ajitanand, N. N.*; Akiba, Yasuyuki*; Al-Bataineh, H.*; Alexander, J.*; Aoki, Kazuya*; Aphecetche, L.*; Armendariz, R.*; et al.
Physical Review C, 83(6), p.064903_1 - 064903_29, 2011/06
Times Cited Count:184 Percentile:99.44(Physics, Nuclear)Transverse momentum distributions and yields for , and in collisions at = 200 and 62.4 GeV at midrapidity are measured by the PHENIX experiment at the RHIC. We present the inverse slope parameter, mean transverse momentum, and yield per unit rapidity at each energy, and compare them to other measurements at different collisions. We also present the scaling properties such as and scaling and discuss the mechanism of the particle production in collisions. The measured spectra are compared to next-to-leading order perturbative QCD calculations.
Adare, A.*; Afanasiev, S.*; Aidala, C.*; Ajitanand, N. N.*; Akiba, Yasuyuki*; Al-Bataineh, H.*; Alexander, J.*; Aoki, Kazuya*; Aphecetche, L.*; Aramaki, Y.*; et al.
Physical Review C, 83(4), p.044912_1 - 044912_16, 2011/04
Times Cited Count:8 Percentile:49.7(Physics, Nuclear)Measurements of electrons from the decay of open-heavy-flavor mesons have shown that the yields are suppressed in Au+Au collisions compared to expectations from binary-scaled collisions. Here we extend these studies to two particle correlations where one particle is an electron from the decay of a heavy flavor meson and the other is a charged hadron from either the decay of the heavy meson or from jet fragmentation. These measurements provide more detailed information about the interaction between heavy quarks and the quark-gluon matter. We find the away-side-jet shape and yield to be modified in Au+Au collisions compared to collisions.
Adare, A.*; Afanasiev, S.*; Aidala, C.*; Ajitanand, N. N.*; Akiba, Y.*; Al-Bataineh, H.*; Alexander, J.*; Aoki, K.*; Aphecetche, L.*; Armendariz, R.*; et al.
Physical Review D, 83(5), p.052004_1 - 052004_26, 2011/03
Times Cited Count:175 Percentile:98.48(Astronomy & Astrophysics)The PHENIX experiment at RHIC has measured the invariant differential cross section for production of , , and mesons in collisions at = 200 GeV. The spectral shapes of all hadron transverse momentum distributions are well described by a Tsallis distribution functional form with only two parameters, and , determining the high and characterizing the low regions for the spectra, respectively. The integrated invariant cross sections calculated from the fitted distributions are found to be consistent with existing measurements and with statistical model predictions.
Russo, P. A.*; Asakura, Yoshiro*; Hsue, S. T.*; Kondo, Isao*; Sprinkle, J. K. Jr.*; Masui, J.*; Johnson, S. S.*; Shoji, J.*
PNC TN841 82-10, 76 Pages, 1982/08
An instrument based upon high-resolution -ray measurements has beentested for more than 1 year at the TokaiReprocessing Facility for determinationof plutonium concentration by K-edge absorption densitometry and for determination of plutonium isotopic fractions bytransmission-corrected passive -ray spectrometry. The nondestructive assay instrument was designed and built atLos Alamos National Laboratory for theTokai Advanced Safeguards Technology Exercise (TASTEX). It was used at Tokai forthe timely assay of more than 100 productsolution samples daring the TASTEX evaluations The results were compared tosolution samples during the TASTEXaluations. The results were compared toreference values obtained by conventionaldestructive analysis of these samples. The precision and accuracy of plutoniumconcentrations measured by the K-edgetechnique are shown to be with in 0.6% (1) in these applications. The precisionsand accuracies of the isotopic fractions. determined by these passive
Kaburagi, Masaaki; Shimazoe, Kenji*; Otaka, Yutaka*; Uenomachi, Mizuki*; Kamada, Kei*; Kim, K. J.*; Yoshino, Masao*; Shoji, Yasuhiro*; Yoshikawa, Akira*; Takahashi, Hiroyuki*; et al.
no journal, ,
The retrieval of the nuclear fuel debris, which is the substance including melted nuclear fuel and structural materials, will be started from fiscal 2021. Then, as a non-destructive analysis technology of the nuclear fuel debris, a -ray spectroscopy system is being developed to measure high energy rays due to Eu and nuclear reactions under high dose rate, which was composed of a CeBr cubic, photomultiplier tube, and fast signal processing unit. This presentation reports that the exposure study of the detector system was performed for a Co field at the dose rates of up to 750 mSv/h, and the detector response was investigated at each dose rate.
Kaburagi, Masaaki; Shimazoe, Kenji*; Kato, Masahiro*; Kurosawa, Tadahiro*; Kamada, Kei*; Kim, K. J.*; Yoshino, Masao*; Shoji, Yasuhiro*; Yoshikawa, Akira*; Takahashi, Hiroyuki*; et al.
no journal, ,
The retrieval of nuclear fuel debris will be started at Tokyo Electrical Power Company Holdings' Fukushima Daiichi Nuclear Power Station. Because of high dose-rate fields on the surface of nuclear fuel debris and these inhomogeneous elements, non-destructive analysis is required during the retrieval. Here, it is presented that a -ray spectrometry system specific to high dose-rate fields was developed and its performance under intense -ray fields was evaluated for the retrieval of nuclear fuel debris.