Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Yatsuka, Eiichi; Hatae, Takaki; Suito, Satoshi*; Ohara, Miyuki*; Hagita, Koji*; Inoue, Kazunori*; Bassan, M.*; Walsh, M.*; Itami, Kiyoshi
Journal of Instrumentation (Internet), 11(1), p.C01006_1 - C01006_12, 2016/01
Times Cited Count:6 Percentile:31.03(Instruments & Instrumentation)Yatsuka, Eiichi; Hatae, Takaki; Suito, Satoshi*; Aida, Yoshiyuki*; Kusama, Yoshinori
Review of Scientific Instruments, 81(10), p.10D541_1 - 10D541_4, 2010/10
Times Cited Count:6 Percentile:30.96(Instruments & Instrumentation)Tojo, Hiroshi; Hatae, Takaki; Sakuma, Takeshi; Hamano, Takashi; Itami, Kiyoshi; Aida, Yoshiaki*; Suito, Satoshi*; Fujie, Daijiro*
Review of Scientific Instruments, 81(10), p.10D539_1 - 10D539_3, 2010/10
Times Cited Count:10 Percentile:44.17(Instruments & Instrumentation)Designs of collection optics for JT-60SA Thomson scattering system are presented. By using tangential (to the toroidal direction) YAG laser injection, three collection optics without strong chromatic aberrations generated by the wide viewing angle and small design volume measure almost all the radial space. For the edge plasma measurements, we optimized the channel number and wavelength ranges of band-pass filters in polychromator to reduce relative error in the electron temperature by considering the all spatial channels and double-pass laser system with different geometric parameters.
Tojo, Hiroshi; Hatae, Takaki; Sakuma, Takeshi; Hamano, Takashi; Shinohara, Koji; Itami, Kiyoshi; Aida, Yoshiaki*; Suito, Satoshi*; Fujie, Daijiro*
no journal, ,
Conceptual designs of the collection optics for JT-60SA Thomson scattering have been done. Adapting four glass materials of the lenses used for the collection optics enables to correct the chromatic aberrations with good resolution ( 1 mm). The whole radial profile can be measured using three designed collection optics in Port-P1, P2 and P5. The collection optics will be installed in port-plugs accessing from the cryostat to vacuum vessel. In a disruption with a decrease of the plasma current by a time scale of 5 MA/8 ms, the eddy current (0.1 MA/m) is strongly generated in the area of 500 mm from the edge of the port-plug with the thickness of 30 mm. Even if the thickness is reduced to 20 mm decreasing the current in the area, the maximum principal stress is still under the limit value for the design.
Yatsuka, Eiichi; Hatae, Takaki; Suito, Satoshi*; Aida, Yoshiaki*; Kusama, Yoshinori
no journal, ,
no abstracts in English
Tojo, Hiroshi; Hatae, Takaki; Sakuma, Takeshi; Hamano, Takashi; Itami, Kiyoshi; Suito, Satoshi*; Araki, Takashi*; Iwamoto, Kohei*; Takeda, Yuya*
no journal, ,