Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 24

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Characteristics of beta reference radiation fields at the Facility of Radiation Standards (FRS), JAEA for their practical applications in beta dosimetry

Yoshitomi, Hiroshi; Kowatari, Munehiko; Suzuki, Takashi

Proceedings of 4th Asian and Oceanic Congress on Radiation Protection (AOCRP-4) (CD-ROM), 4 Pages, 2015/07

The Facility of Radiation Standards (FRS) in the Japan Atomic Energy Agency (JAEA) provides beta-ray calibration fields for the customers to calibrate dosemeters. Two different types of beta-ray irradiation systems, so called BSS2 and JBS, have been installed and operated in the FRS. They have quite different types of the beta-ray radiation sources, which might be attributed to variations in dosimetric quantities. Variations in these quantities would affect the calibration factor of a dosemeter. A comparison of dosimetric quantities for beta reference radiation fields of both beta-ray irradiation systems was made, in order to investigate how these quantities differ between them and how much differences affect calibration results. With regard to the depth dose curve which is one of the key dosimetric quantities, it was found that they showed different profiles between both systems reflecting their characteristics. This implies that the difference between two systems might affect the calibration of dosemeters, especially one with more than 400 mg/cm$$^2$$ thickness or one made of high-Z materials for $$^{90}$$Sr/$$^{90}$$Y field.

Journal Articles

Development of a widely usable amino acid tracer; $$^{76}$$Br-$$alpha$$-methyl-phenylalanine for tumor PET imaging

Hanaoka, Hirofumi*; Ohshima, Yasuhiro; Suzuki, Yurika*; Yamaguchi, Aiko*; Watanabe, Shigeki; Uehara, Tomoya*; Nagamori, Shushi*; Kanai, Yoshikatsu*; Ishioka, Noriko; Tsushima, Yoshito*; et al.

Journal of Nuclear Medicine, 56(5), p.791 - 797, 2015/05

 Times Cited Count:18 Percentile:62.62(Radiology, Nuclear Medicine & Medical Imaging)

Journal Articles

Biological significance of fluorine-18-$$alpha$$-methyltyrosine (FAMT) uptake on PET in patients with oesophageal cancer

Suzuki, Shigemasa*; Kaira, Kyoichi*; Ohshima, Yasuhiro; Ishioka, Noriko; Soda, Makoto*; Yokobori, Takehiko*; Miyazaki, Tatsuya*; Oriuchi, Noboru*; Tominaga, Hideyuki*; Kanai, Yoshikatsu*; et al.

British Journal of Cancer, 110(8), p.1985 - 1991, 2014/04

 Times Cited Count:24 Percentile:60.43(Oncology)

Journal Articles

Application of the small OSL elements to the ring type dosemeter

Miyauchi, Hideaki; Yoshitomi, Hiroshi; Sato, Yoshitaka; Takahashi, Fumiaki; Tachibana, Haruo; Kobayashi, Ikuo*; Suzuki, Akifumi*

Nihon Hoshasen Anzen Kanri Gakkai-Shi, 12(1), p.41 - 45, 2013/07

In the Japan Atomic Energy Agency (JAEA), exposures to fingertips can be significant in radiological decontamination at the facilities with mixture fields of beta and $$gamma$$ (X) rays. The radiation doses to fingertips have been measured by ring type dosemeters equipped with thermoluminescence dosemeters (TLD) in JAEA. We applied small Optically Stimulated Luminescence (OSL) elements to the ring type dosemeter, which has the advantages in the use for long term and repeating in dose measurements comparing to the TLDs. In this report, we introduce the outline and the dose evaluation method of the new ring type dosimeter which we applied.

Journal Articles

Mock-up test results of monoblock-type CFC divertor armor for JT-60SA

Higashijima, Satoru; Sakurai, Shinji; Suzuki, Satoshi; Yokoyama, Kenji; Kashiwa, Yoshitoshi; Masaki, Kei; Shibama, Yusuke; Takechi, Manabu; Shibanuma, Kiyoshi; Sakasai, Akira; et al.

Fusion Engineering and Design, 84(2-6), p.949 - 952, 2009/06

 Times Cited Count:9 Percentile:53.3(Nuclear Science & Technology)

An upgrading device of JT-60 tokamak with fully superconducting coils (JT-60SA) is constructed under both the Japanese domestic program and the international program "Broader Approach". The maximum heat flux to JT-60SA divertor is estimated to 15 MW/m$$^{2}$$ for 100 s, and a monoblock-type CFC divertor armor is promising. The JT-60SA armor consists of CFC monoblocks, a cooling CuCrZr screw-tube, and a thin OFHC-Cu buffer layer, and the brazed joints are essential for the armor. Metalization inside CFC monoblock is applied for further improvement, and we confirmed again that the mock-up has heat removal capability in excess of ITER requirement. For optimization of the fabrication method and understanding of the production yield, the mock-ups corresponding to quantity produced in one furnace is also produced, and the half of the mock-ups could remove 15 MW/m$$^{2}$$ as required. This summarizes the recent progress of design and mock-up test results for JT-60SA divertor armor.

Journal Articles

Compact toroid injection system for JFT-2M

Fukumoto, Naoyuki*; Ogawa, Hiroaki; Nagata, Masayoshi*; Uyama, Tadao*; Shibata, Takatoshi; Kashiwa, Yoshitoshi; Suzuki, Sadaaki; Kusama, Yoshinori; JFT-2M Group

Fusion Engineering and Design, 81(23-24), p.2849 - 2857, 2006/11

 Times Cited Count:7 Percentile:46.04(Nuclear Science & Technology)

no abstracts in English

Journal Articles

A Migration analysis of ${it Sogatella furcifera}$ (Horv$'a$th) (Homoptera: Delphacidae) using hourly catches and a three-dimensional simulation model

Otsuka, Akira*; Watanabe, Tomonari*; Suzuki, Yoshito*; Matsumura, Masaya*; Furuno, Akiko; Chino, Masamichi; Kondo, Tomoya*; Kamimuro, Tsuyoshi*

Agricultural and Forest Entomology, 8(1), p.35 - 47, 2006/02

 Times Cited Count:17 Percentile:58.03(Entomology)

1 Migration of Sogatella furcifera captured in Japan in the 2003 season were analyzed using hourly catches and a simulation model.2. The catch data showed several clear migration peaks, with average durations of 4 h. The peaks were separated from each other by approximately 12 h, corresponding to the observed fact that planthoppers take off at dusk and dawn.3. The simulation model, together with the hourly catches, enabled an estimation of migration source regions.4. Possible migration sources during our hourly observation period were located in the coastal area of Fujian province in China, as well as Taiwan.

Journal Articles

CT injection experiment in JFT-2M

Ogawa, Hiroaki; Ogawa, Toshihide; Tsuzuki, Kazuhiro; Kawashima, Hisato; Kasai, Satoshi*; Kashiwa, Yoshitoshi; Hasegawa, Koichi; Suzuki, Sadaaki; Shibata, Takatoshi; Miura, Yukitoshi; et al.

Fusion Science and Technology, 49(2), p.209 - 224, 2006/02

 Times Cited Count:3 Percentile:24.11(Nuclear Science & Technology)

no abstracts in English

Journal Articles

Development of a numerical simulation model for long-range migration of rice planthoppers

Furuno, Akiko; Chino, Masamichi; Otsuka, Akira*; Watanabe, Tomonari*; Matsumura, Masaya*; Suzuki, Yoshito*

Agricultural and Forest Meteorology, 133(1-4), p.197 - 209, 2005/11

 Times Cited Count:21 Percentile:55.78(Agronomy)

Transoceanic migration of rice planthoppers was precisely simulated by incorporating several parameters related to the flight behavior with a high performance atmospheric dispersion model. The model consists of an atmospheric dynamic submodel and a particle random-walk submodel for atmospheric dispersion. The model also functions in specifying the release area of the migration of planthoppers. Using this model, we carried out a case study simulating the migration of planthoppers to western Japan in mid-June 1998. In the simulation, 56 areas each with a width of two degrees of latitude and longitude were set as tentative take-off areas. The calculated density of immigrants was compared with each observed density by rank correlation coefficients. Possible migration release areas which showed a high correlation to observations were distributed around 23-27N, including Fujian and Taiwan. An air temperature that allowed the planthoppers to fly continuously and flight duration were critical parameters for the simulation results.

Journal Articles

Divertor biasing effects to reduce L/H power threshold in the JFT-2M tokamak

Miura, Yukitoshi; *; *; Hoshino, Katsumichi; *; *; Kasai, Satoshi; Kawakami, Tomohide; Kawashima, Hisato; Maeda, M.*; et al.

Fusion Energy 1996, p.167 - 175, 1997/05

no abstracts in English

Journal Articles

Investigation of causality in the H-L transition on the JFT-2M tokamak

*; *; *; *; *; *; *; Oikawa, Toshihiro; *; *; et al.

Fusion Energy 1996, p.885 - 890, 1997/05

no abstracts in English

Oral presentation

Monitoring for chemical property of muck from deep shaft

Yamanishi, Takeshi; Sekiya, Yoshitomo; Suzuki, Tatsuya; Ito, Seiji; Kitagawa, Yoshito*; Hagihara, Takeshi*; Doi, Takashi*; Saito, Ryosuke*

no journal, , 

no abstracts in English

Oral presentation

Chemical property and future issues of control typed muck

Yamanishi, Takeshi; Sekiya, Yoshitomo; Suzuki, Tatsuya; Kitagawa, Yoshito*; Saito, Ryosuke*; Yokota, Daisuke*

no journal, , 

no abstracts in English

Oral presentation

Chemical property and future issues of control typed muck at stockyard

Yamanishi, Takeshi; Sekiya, Yoshitomo; Suzuki, Tatsuya; Kitagawa, Yoshito*; Kato, Kinya*; Saito, Ryosuke*

no journal, , 

no abstracts in English

Oral presentation

Development of the server system for Personal Dose Management

Miyauchi, Hideaki; Yoshitomi, Hiroshi; Akazaki, Tomohiko; Tachibana, Haruo; Suzuki, Takashi

no journal, , 

In the Nuclear Science Research Institute in the Japan Atomic Energy Agency (JAEA), the registration management of exposure dose data for radiation workers has been carried out using the "Personal dose Management System" that is took over from the old Japan Atomic Energy Research Institute. In accordance with the result of the discussion which of unification of a radiation control system, or rationalization in JAEA, development of the server system for Personal Dose Management was gradually advanced from 2006, all functions were ready in 2010, and the server system started formal operation in 2011. By the development of the server system, work efficiency and the accuracy of data improved, and more precise management of exposure dose was enabled.

Oral presentation

Personal monitoring for assistance staff to Fukushima

Suzuki, Takehiko; Murayama, Takashi; Miyauchi, Hideaki; Sato, Yoshitaka; Oi, Yoshihiro; Tachibana, Haruo; Yoshitomi, Hiroshi

no journal, , 

Nuclear Science Research Institute is assisting activities concerning the accident of the Fukushima No.1 Nuclear Power Station including the environmental monitoring and the resident's house decontamination, etc. In these assistance, we executing the personal monitoring to assistance staff, because there was fear of the external exposure and the internal exposure. We did by the measurement and the evaluation method of the personal monitoring in consideration of the rise of the environmental background level. We introduce the method of use to evaluate the exposed dose etc.

Oral presentation

Feasibility of OSL dosimeter for environmental $$gamma$$-ray monitoring

Okura, Takehisa; Oishi, Tetsuya; Miyauchi, Hideaki; Yoshitomi, Hiroshi; Tachibana, Haruo; Higashi, Daisuke; Suzuki, Akifumi*; Kobayashi, Ikuo*

no journal, , 

no abstracts in English

Oral presentation

OSL dosimetry in radiation control; For extremity dose monitoring

Yoshitomi, Hiroshi; Miyauchi, Hideaki; Sato, Yoshitaka; Nojima, Shun; Tachibana, Haruo; Suzuki, Takashi; Takahashi, Fumiaki; Kobayashi, Ikuo*; Suzuki, Akifumi*

no journal, , 

no abstracts in English

Oral presentation

Application of the small OSL elements to the ring type dosemeter

Miyauchi, Hideaki; Yoshitomi, Hiroshi; Takahashi, Fumiaki; Tachibana, Haruo; Suzuki, Akifumi; Sato, Yoshitaka*; Kobayashi, Ikuo*

no journal, , 

In the Japan Atomic Energy Agency (JAEA), exposures to fingertips can be significant in radiological decontamination at the facilities with mixture fields of beta and $$gamma$$ (X) rays. The radiation doses to fingertips have been measured by ring type dosemeters equipped with thermoluminescence dosemeters (TLD) in JAEA. We applied small Optically Stimulated Luminescence (OSL) elements to the ring type dosemeter, which has the advantages in the use for long term and repeating in dose measurements comparing to the TLDs. The ring type dosemeter using OSL elements have started operating from 2012.

Oral presentation

Development of 2-[$$^{211}$$At]astato-$$alpha$$-methyl-L-phenylalanine (2-AAMP) as a novel radiopharmaceutical for internal radiotherapy

Ohshima, Yasuhiro; Suzuki, Hiroyuki*; Hanaoka, Hirofumi*; Watanabe, Shigeki; Watanabe, Satoshi; Watanabe, Naoyuki*; Tsushima, Yoshito*; Endo, Keigo*; Arano, Yasushi*; Ishioka, Noriko

no journal, , 

24 (Records 1-20 displayed on this page)