Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 391

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Application of control software framework to sample environment equipment in J-PARC MLF

Hasemi, Hiroyuki; Takahashi, Ryuta*; Yamauchi, Yasuhiro*; Ishikado, Motoyuki*; Kawamura, Seiko; Komine, Ryota

JPS Conference Proceedings (Internet), 41, p.011003_1 - 011003_5, 2024/03

Journal Articles

Neutron/$$gamma$$-ray discrimination based on the property and thickness controls of scintillators using Li glass and LiCAF(Ce) in a $$gamma$$-ray field

Kaburagi, Masaaki; Shimazoe, Kenji*; Terasaka, Yuta; Tomita, Hideki*; Yoshihashi, Sachiko*; Yamazaki, Atsushi*; Uritani, Akira*; Takahashi, Hiroyuki*

Nuclear Instruments and Methods in Physics Research A, 1046, p.167636_1 - 167636_8, 2023/01

 Times Cited Count:3 Percentile:90.12(Instruments & Instrumentation)

We focus on the thickness and property controls of inorganic scintillators used for thermal neutron detection in intense $$gamma$$-ray fields without considering pulse shape discrimination techniques. GS20$$^{rm{TM}}$$ (a lithium glass) and LiCaAlF$$_6$$:Ce(LiCAF:Ce) cintillators with thicknesses of 0.5 and 1.0 mm, respectively, have been employed. Pulse signals generated by photomultiplier tubes, to which the scintillators were coupled, were inserted into a digital pulse processing unit with 1 Gsps, and the areas of waveforms were integrated for 360 ns. In a $$^{60}$$Co $$gamma$$-ray field, the neutron detection for GS20$$^{rm{TM}}$$ with a 0.5-mm thickness was possible at dose rates of up to 0.919 Gy/h; however, for LiCAF:Ce, neutron detection was possible at 0.473 Gy/h, and it failed at 0.709 Gy/h. Threfore, in a $$^{60}$$Co $$gamma$$-ray field, the neutron/$$gamma$$-ray discrimination of GS20$$^{rm{TM}}$$ was better than that of LiCAF:Ce due to its better energy resolution and higher detection efficiency.

Journal Articles

Measurement of the transverse asymmetry of $$gamma$$ rays in the $$^{117}$$Sn($$n,gamma$$)$$^{118}$$Sn reaction

Endo, Shunsuke; Okudaira, Takuya*; Abe, Ryota*; Fujioka, Hiroyuki*; Hirota, Katsuya*; Kimura, Atsushi; Kitaguchi, Masaaki*; Oku, Takayuki; Sakai, Kenji; Shima, Tatsushi*; et al.

Physical Review C, 106(6), p.064601_1 - 064601_7, 2022/12

 Times Cited Count:2 Percentile:52.69(Physics, Nuclear)

no abstracts in English

Journal Articles

Interfacial distribution of Nafion ionomer thin films on nitrogen-modified carbon surfaces

Yoshimune, Wataru*; Kikkawa, Nobuaki*; Yoneyama, Hiroaki*; Takahashi, Naoko*; Minami, Saori*; Akimoto, Yusuke*; Mitsuoka, Takuya*; Kawaura, Hiroyuki*; Harada, Masashi*; Yamada, Norifumi*; et al.

ACS Applied Materials & Interfaces, 14(48), p.53744 - 53754, 2022/11

 Times Cited Count:6 Percentile:59.75(Nanoscience & Nanotechnology)

Journal Articles

Design and actual performance of J-PARC 3 GeV rapid cycling synchrotron for high-intensity operation

Yamamoto, Kazami; Kinsho, Michikazu; Hayashi, Naoki; Saha, P. K.; Tamura, Fumihiko; Yamamoto, Masanobu; Tani, Norio; Takayanagi, Tomohiro; Kamiya, Junichiro; Shobuda, Yoshihiro; et al.

Journal of Nuclear Science and Technology, 59(9), p.1174 - 1205, 2022/09

 Times Cited Count:6 Percentile:84.97(Nuclear Science & Technology)

In the Japan Proton Accelerator Research Complex, the purpose of the 3 GeV rapid cycling synchrotron (RCS) is to accelerate a 1 MW, high-intensity proton beam. To achieve beam operation at a repetition rate of 25 Hz at high intensities, the RCS was elaborately designed. After starting the RCS operation, we carefully verified the validity of its design and made certain improvements to establish a reliable operation at higher power as possible. Consequently, we demonstrated beam operation at a high power, namely, 1 MW. We then summarized the design, actual performance, and improvements of the RCS to achieve a 1 MW beam.

Journal Articles

Identification and quantification of a $$^{60}$$Co radiation source under an intense $$^{137}$$Cs radiation field using an application-specific CeBr$$_3$$ spectrometer suited for use in intense radiation fields

Kaburagi, Masaaki; Shimazoe, Kenji*; Kato, Masahiro*; Kurosawa, Tadahiro*; Takahashi, Hiroyuki*

Journal of Nuclear Science and Technology, 59(8), p.983 - 992, 2022/08

 Times Cited Count:0 Percentile:0.01(Nuclear Science & Technology)

Journal Articles

Development of the multi-cubic $$gamma$$-ray spectrometer and its performance under intense $$^{137}$$Cs and $$^{60}$$Co radiation fields

Kaburagi, Masaaki; Shimazoe, Kenji*; Kato, Masahiro*; Kurosawa, Tadahiro*; Kamada, Kei*; Kim, K. J.*; Yoshino, Masao*; Shoji, Yasuhiro*; Yoshikawa, Akira*; Takahashi, Hiroyuki*

Nuclear Instruments and Methods in Physics Research A, 1010, p.165544_1 - 165544_9, 2021/09

 Times Cited Count:0 Percentile:0.02(Instruments & Instrumentation)

The number of nuclear facilities being decommissioned has been increasing worldwide, in particular following the accident of the Tokyo Electric Power Company Holdings' Fukushima Daiichi Nuclear Power Station in 2011. In these nuclear facilities, proper management of radioactive materials is required. Then, A $$gamma$$-ray spectrometer with four segmentations using small volume CeBr$$_{3}$$ scintillators with a dimension of $$5 times 5 times 5$$ $$rm{mm}^3$$ was developed. The four scintillators were coupled to a multi-anode photomultiplier tube specific to intense radiation fields. We performed the $$gamma$$-ray exposure study under $$^{137}$$Cs and $$^{60}$$Co radiation fields. Under the $$^{137}$$Cs radiation field, the relative energy resolution at 1375 mSv/h was the relative energy resolution at 1375 mSv/h was 9.2$$pm$$0.05%, 8.0$$pm$$0.08%, 8.0$$pm$$0.03%, and 9.0$$pm$$0.04% for the four channels, respectively.

Journal Articles

4-Methylumbelliferone administration enhances radiosensitivity of human fibrosarcoma by intercellular communication

Saga, Ryo*; Matsuya, Yusuke; Takahashi, Rei*; Hasegawa, Kazuki*; Date, Hiroyuki*; Hosokawa, Yoichiro*

Scientific Reports (Internet), 11(1), p.8258_1 - 8258_10, 2021/04

 Times Cited Count:4 Percentile:47.6(Multidisciplinary Sciences)

Hyaluronan synthesis inhibitor 4-methylumbelliferone (4-MU) is a candidate of radiosensitizers in X-ray therapy. The curative effects under such 4-MU administration have been investigated in vitro; however, the radiosensitizing mechanisms remain unclear. Here, we investigated the radiosensitizing effects under 4-MU treatment from cell experiments and model estimations. We generated experimental surviving fractions of human fibrosarcoma cells (HT1080) after 4-MU treatment combined with X-ray irradiation. Meanwhilst, we also modelled the pharmacological effects of 4-MU treatment and theoretically analyzed the synergetic effects between 4-MU treatment and X-ray irradiation. The results show that the enhancement of cell killing by 4-MU treatment is the greatest in the intermediate dose range of around 4 Gy, which indicates the involvement of intercellular communication. In addition, the oxidative stress level, which leads to DNA damage induction, significantly increased under 4-MU treatment, and the radiosensitization by 4-MU can be suppressed by the inhibitors for intercellular communication. These findings suggest that the synergetic effects between 4-MU treatment and irradiation are predominantly attributed to intercellular communication and provide more efficient tumour control than conventional X-ray therapy.

Journal Articles

Incorporation of U, Pb and rare earth elements in calcite through crystallisation from amorphous calcium carbonate; Simple preparation of reference materials for microanalysis

Miyajima, Yusuke*; Saito, Ayaka*; Kagi, Hiroyuki*; Yokoyama, Tatsunori; Takahashi, Yoshio*; Hirata, Takafumi*

Geostandards and Geoanalytical Research, 45(1), p.189 - 205, 2021/03

 Times Cited Count:5 Percentile:21.77(Geochemistry & Geophysics)

Uncertainty for elemental and isotopic analyses of calcite by LA-ICP-MS is largely controlled by the homogeneity of the reference materials (RMs) used for normalization and validation. In order to produce calcite RMs with homogeneous elemental and isotopic compositions, we incorporated elements including U, Pb, and rare earth elements into calcite through heat- and pressure-induced crystallization from amorphous calcium carbonate that was precipitated from element-doped reagent solution. X-ray absorption spectra showed that U was present as U(VI) in the synthesized calcite, probably with a different local structure from that of aqueous uranyl ions. The uptake rate of U by our calcite was higher in comparison to synthetic calcite of previous studies. Variations of element mass fractions in the calcite were better than 12% 2RSD, mostly within 7%. The $$^{207}$$Pb/$$^{206}$$Pb ratio in the calcite showed $$<$$1% variations, while the $$^{238}$$U/$$^{206}$$Pb ratio showed 3-24% variations depending on element mass fractions. Using the synthetic calcite as primary RMs, we could date a natural calcite RM, WC-1, with analytical uncertainty as low as $$<$$3%. The method presented can be useful to produce calcite with controlled and homogeneous element mass fractions, and is a promising alternative to natural calcite RMs for U-Pb geochronology.

Journal Articles

Gamma-ray spectroscopy with a CeBr$$_3$$ scintillator under intense $$gamma$$-ray fields for nuclear decommissioning

Kaburagi, Masaaki; Shimazoe, Kenji*; Kato, Masahiro*; Kurosawa, Tadahiro*; Kamada, Kei*; Kim, K. J.*; Yoshino, Masao*; Shoji, Yasuhiro*; Yoshikawa, Akira*; Takahashi, Hiroyuki*; et al.

Nuclear Instruments and Methods in Physics Research A, 988, p.164900_1 - 164900_8, 2021/02

 Times Cited Count:11 Percentile:89.29(Instruments & Instrumentation)

An increasing number of nuclear facilities have been decommissioned worldwide following the 2011 accident of the TEPCO' Fukushima Daiichi Nuclear Power Station. During the decommissioning, radioactive materials have to be retrieved under proper management. In this study, a small cubic CeBr$$_3$$ spectrometer with dimensions of 5 mm $$times$$ 5 mm $$times$$ 5 mm was manufactured to perform $$gamma$$-ray spectroscopy under intense $$gamma$$-ray fields. Furthermore, thanks to a fast digital process unit and a customized photomultiplier, the device could perform $$gamma$$-ray spectroscopy at dose rates of over 1 Sv/h. The energy resolution (FWHM) at 662 keV ranged from 4.4% at 22 mSv/h to 5.2% at 1407 mSv/h for a $$^{137}$$Cs radiation field. Correspondingly, at 1333 keV, it ranged from 3.1% at 26 mSv/h to 4.2% at 2221 mSv/h for a $$^{60}$$Co radiation field, which suggested to realize $$gamma$$-ray assessment of $$^{134}$$Cs, $$^{137}$$Cs, $$^{60}$$Co, and $$^{154}$$Eu at dose rates of over 1 Sv/h.

Journal Articles

Corrosion resistance of a cast steel overpack for high-level radioactive waste disposal in Japan

Ogawa, Yusuke*; Suzuki, Satoru*; Taniguchi, Naoki; Kawasaki, Manabu*; Suzuki, Hiroyuki*; Takahashi, Rieko*

Materials and Corrosion, 72(1-2), p.52 - 66, 2021/01

 Times Cited Count:2 Percentile:12.73(Materials Science, Multidisciplinary)

Cast steel is one of the promising alternative to forged steel that is the current reference material for carbon steel overpack. In this study, the full-scale cast steel overpack was produced experimentally and the distribution of casting defects were investigated. The corrosion test regarding corrosion rate and stress corrosion cracking (SCC) susceptibility were also conducted using samples taken from the full-scale cast steel overpack and the corrosion resistance of cast steel was compared with that of forged steel. From above two corrosion tests, it can be said that the corrosion resistance of cast steel is mostly the same as that of forged steel.

Journal Articles

A Cubic CeBr$$_{3}$$ gamma-ray spectrometer suitable for the decommissioning of the Fukushima Daiichi Nuclear Power Station

Kaburagi, Masaaki; Shimazoe, Kenji*; Otaka, Yutaka*; Uenomachi, Mizuki*; Kamada, Kei*; Kim, K. J.*; Yoshino, Masao*; Shoji, Yasuhiro*; Yoshikawa, Akira*; Takahashi, Hiroyuki*; et al.

Nuclear Instruments and Methods in Physics Research A, 971, p.164118_1 - 164118_8, 2020/08

 Times Cited Count:7 Percentile:66.68(Instruments & Instrumentation)

Journal Articles

Giant spin hydrodynamic generation in laminar flow

Takahashi, Ryo*; Chudo, Hiroyuki; Matsuo, Mamoru; Harii, Kazuya*; Onuma, Yuichi*; Maekawa, Sadamichi; Saito, Eiji

Nature Communications (Internet), 11, p.3009_1 - 3009_6, 2020/06

 Times Cited Count:18 Percentile:80.01(Multidisciplinary Sciences)

Journal Articles

$$omega N$$ scattering length from $$omega$$ photoproduction on the proton near the reaction threshold

Ishikawa, Takatsugu*; Fujimura, Hisako*; Fukasawa, Hiroshi*; Hashimoto, Ryo*; He, Q.*; Honda, Yuki*; Hosaka, Atsushi; Iwata, Takahiro*; Kaida, Shun*; Kasagi, Jirota*; et al.

Physical Review C, 101(5), p.052201_1 - 052201_6, 2020/05

 Times Cited Count:4 Percentile:45.12(Physics, Nuclear)

Journal Articles

Pre- and post-accident $$^{14}$$C activities in tree rings near the Fukushima Dai-ichi Nuclear Power Plant

Matsunaka, Tetsuya*; Sasa, Kimikazu*; Takahashi, Tsutomu*; Matsumura, Masumi*; Satou, Yukihiko; Shen, H.*; Sueki, Keisuke*; Matsuzaki, Hiroyuki*

Radiocarbon, 61(6), p.1633 - 1642, 2019/12

 Times Cited Count:2 Percentile:11.66(Geochemistry & Geophysics)

Journal Articles

Analysis of the high-dose-range radioresistance of prostate cancer cells, including cancer stem cells, based on a stochastic model

Saga, Ryo*; Matsuya, Yusuke; Takahashi, Rei*; Hasegawa, Kazuki*; Date, Hiroyuki*; Hosokawa, Yoichiro*

Journal of Radiation Research, 60(3), p.298 - 307, 2019/05

 Times Cited Count:23 Percentile:81.57(Biology)

In radiotherapy, it is recognized that cancer stem cells (CSCs) in tumor tissue shows radio-resistance. However, the relationship between content percentage of the CSCs and dose-response curve on cell survival remain unclear. In this study, we developed a stochastic model considering progeny cells and stem cells, and investigated the impact of stem cells on radio-sensitivity. From the flow-cytometric analysis (cell experiments), the content percentage of stem cells was 3.2% or less which agreed well with the model estimation from the cell survival curve. Based on the verification, it is suggested that cell survival in high-dose range is largely affected by the CSCs. In addition, regarding the sub-population of stem cells, the present model well reproduces the dose response on lethal lesions to DNA comparing with the conventional LQ model. This outcome indicates that the stem cells must be considered for describing the dose-response curve in wide dose range.

Journal Articles

Development of compact high field pulsed magnet system for new sample environment equipment at MLF in J-PARC

Watanabe, Masao; Nojiri, Hiroyuki*; Ito, Shinichi*; Kawamura, Seiko; Kihara, Takumi*; Masuda, Takatsugu*; Sahara, Takuro*; Soda, Minoru*; Takahashi, Ryuta

JPS Conference Proceedings (Internet), 25, p.011024_1 - 011024_5, 2019/03

Recently, neutron scattering experiments have been rapidly progressed under high magnetic field. In the J-PARC, proto-type compact pulse magnet system with the power supply, the coil and the sample stick has been developed. Basic specifications of the power supply are as follows; maximum charged voltage with capacitor is 2 kV, maximum current is 8 kA, repetition rate is a pulse per several minutes and pulse duration is several msec. Maximum magnetic field in the coil is more than 30 Tesla. The sample stick is designed for Orange-Cryostat. In this presentation, We report the details of the pulsed magnet system and the performance of it on neutron scattering experiments at MLF beam line (HRC).

Journal Articles

Gamma-ray imaging system for Fukushima Daiichi Nuclear Power Plant using silicon strip detector

Kaburagi, Masaaki; Sato, Yuki; Yoshihara, Yuri*; Shimazoe, Kenji*; Takahashi, Hiroyuki*; Torii, Tatsuo

Reactor Dosimetry; 16th International Symposium on Reactor Dosimetry (ISRD-16) (ASTM STP 1608), p.405 - 414, 2018/11

 Times Cited Count:0 Percentile:0.05(Nuclear Science & Technology)

Journal Articles

Fabrication and magnetic control of Y$$_3$$Fe$$_5$$O$$_{12}$$ cantilevers

Seo, Y.-J.*; Harii, Kazuya; Takahashi, Ryo*; Chudo, Hiroyuki; Oyanagi, Koichi*; Qiu, Z.*; Ono, Takahito*; Shiomi, Yuki*; Saito, Eiji

Applied Physics Letters, 110(13), p.132409_1 - 132409_4, 2017/03

 Times Cited Count:12 Percentile:50.89(Physics, Applied)

We have fabricated ferrite cantilevers in which their vibrational properties can be controlled by external magnetic fields. Submicron-scale cantilever structures were made from Y$$_3$$Fe$$_5$$O$$_{12}$$ films by physical etching combined with the use of a focused ion beam milling technique. We found that the cantilevers exhibit two resonance modes which correspond to horizontal and vertical vibrations. Under external magnetic fields, the resonance frequency of the horizontal mode increases, while that of the vertical mode decreases, quantitatively consistent with our numerical simulation for magnetic forces. The changes in resonance frequencies with magnetic fields reach a few percent, showing that an efficient magnetic control of resonance frequencies was achieved.

Journal Articles

Field test around Fukushima Daiichi Nuclear Power Plant site using improved Ce:Gd$$_{3}$$(Al,Ga)$$_{5}$$O$$_{12}$$ scintillator Compton camera mounted on an unmanned helicopter

Shikaze, Yoshiaki; Nishizawa, Yukiyasu; Sanada, Yukihisa; Torii, Tatsuo; Jiang, J.*; Shimazoe, Kenji*; Takahashi, Hiroyuki*; Yoshino, Masao*; Ito, Shigeki*; Endo, Takanori*; et al.

Journal of Nuclear Science and Technology, 53(12), p.1907 - 1918, 2016/12

 Times Cited Count:37 Percentile:96.48(Nuclear Science & Technology)

The Compton camera was improved for use with the unmanned helicopter. Increase of the scintillator array from 4$$times$$4 to 8$$times$$8 and expanse of the distance between the two layers contributed to the improvements of detection efficiency and angular resolution, respectively. Measurements were performed over the riverbed of the Ukedo river of Namie town in Fukushima Prefecture. By programming of flight path and speed, the areas of 65 m $$times$$ 60 m and 65 m $$times$$ 180 m were measured during about 20 and 30 minutes, respectively. By the analysis the air dose rate maps at 1 m height were obtained precisely with the angular resolution corresponding to the position resolution of about 10 m from 10 m height. Hovering flights were executed over the hot spot areas for 10-20 minutes at 5-20 m height. By using the reconstruction software the $$gamma$$-ray images including the hot spots were obtained with the angular resolution same as that evaluated in the laboratory (about 10$$^{circ}$$).

391 (Records 1-20 displayed on this page)