Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 129

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Development of beam window protection unit for J-PARC Linac

Takahashi, Hiroki; Miyao, Tomoaki*; Hatakeyama, Shuichiro; Ishiyama, Tatsuya*

Proceedings of 19th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.300 - 304, 2023/01

At J-PARC Linac, some beam dumps (BDs) are used for beam conditioning and study. A beam window is installed in the beamlines of each BD. A beam window protection system has been installed in the Linac 0-deg BD after a trouble with the beam window in 2018. However, the current system has not proved to be fully functional for future beam upgrade plan and etc. Then, we started to develop a beam window protection unit with a new function to measure the beam in real time and to inhibit the beam even in the middle of a beam pulse. In this paper, the details and performance of the developed beam window protection unit will be described.

Journal Articles

Reducing the effect of noise generated from stepper motor for H0 collimator in J-PARC RCS

Fujiyama, Hiroki*; Takahashi, Hiroki; Okabe, Kota; Ito, Yuichi*; Hatakeyama, Shuichiro; Suzuki, Takahiro*; Otsu, Satoru*; Yamakawa, Ryuto*

Proceedings of 19th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.529 - 531, 2023/01

Stepper motors are used for mechanical drive in collimators and wire scanner monitors of J-PARC accelerators. Many of these drive unit hardware have been used since the beginning of J-PARC construction, and it is necessary to take measures against aging deterioration. Therefore, we started updating the motor and control system from around 2017. However, when the stepper motor was updated to the current product in the RCS H0 collimator, a malfunction occurred. This is because the drive unit control system cannot correctly recognize the state of the LS (limit switch) due to the noise generated by the motor driver, which hinders the operation. When the noise generated from the old and new stepper motors was measured in a simple test environment for confirmation, it was found that the current product was clearly larger. As a countermeasure, when the wiring of the stepper motor, which was bundled in a single multi-core cable, was separated into separate cables for the power system and LS signal system, the noise level was reduced to about 1/10 and normal operation was restored. I was able to. In this case, we report on noise countermeasures for the RCS H0 collimator drive unit.

Journal Articles

Design and actual performance of J-PARC 3 GeV rapid cycling synchrotron for high-intensity operation

Yamamoto, Kazami; Kinsho, Michikazu; Hayashi, Naoki; Saha, P. K.; Tamura, Fumihiko; Yamamoto, Masanobu; Tani, Norio; Takayanagi, Tomohiro; Kamiya, Junichiro; Shobuda, Yoshihiro; et al.

Journal of Nuclear Science and Technology, 59(9), p.1174 - 1205, 2022/09

 Times Cited Count:6 Percentile:84.97(Nuclear Science & Technology)

In the Japan Proton Accelerator Research Complex, the purpose of the 3 GeV rapid cycling synchrotron (RCS) is to accelerate a 1 MW, high-intensity proton beam. To achieve beam operation at a repetition rate of 25 Hz at high intensities, the RCS was elaborately designed. After starting the RCS operation, we carefully verified the validity of its design and made certain improvements to establish a reliable operation at higher power as possible. Consequently, we demonstrated beam operation at a high power, namely, 1 MW. We then summarized the design, actual performance, and improvements of the RCS to achieve a 1 MW beam.

Journal Articles

Development of a beam window protection system for the J-PARC Linac

Takahashi, Hiroki; Hatakeyama, Shuichiro; Sawabe, Yuki; Miyao, Tomoaki*; Ishiyama, Tatsuya*; Suzuki, Takahiro*

Journal of Physics; Conference Series, 1350, p.012142_1 - 012142_5, 2019/12

 Times Cited Count:0 Percentile:0.06(Physics, Particles & Fields)

At the J-PARC Linac, beam conditioning and study are performed using beam dumps (BDs). To be a partition with the high vacuum section, a beam window (material Ni, 0.38 mm thick, mirror-shape) is installed upstream of the BD along the beam line. Beams that can be accepted by the beam window are about 1/50 or less of rated beam according to thermal evaluation and experience. Therefore, when using a beam dump, it is necessary not to exceed this tolerance. In a 2018 beam study, the beam e that exceeded tolerance was incident on the 0-degree dump due to human error, and the beam window was cracked. Then, this has revealed the need for protection of the beam window by hardware. Therefore, based on the existing system for monitoring the per-hour beam amount, we began to develop a system to monitor one shot beam and one second beam amount. And, we succeeded in implementing a system that protects the beam window by monitoring the beam in a short time (one shot, and for one second). In addition, the performance tests using actual beams were performed, and it was confirmed that the developed system had sufficient performance requirements to protect the beam window.

Journal Articles

Temporal change in radiological environments on land after the Fukushima Daiichi Nuclear Power Plant accident

Saito, Kimiaki; Mikami, Satoshi; Ando, Masaki; Matsuda, Norihiro; Kinase, Sakae; Tsuda, Shuichi; Sato, Tetsuro*; Seki, Akiyuki; Sanada, Yukihisa; Wainwright-Murakami, Haruko*; et al.

Journal of Radiation Protection and Research, 44(4), p.128 - 148, 2019/12

Journal Articles

Development of a beam window protection system for the J-PARC Linac

Takahashi, Hiroki; Hatakeyama, Shuichiro; Sawabe, Yuki; Miyao, Tomoaki*; Ishiyama, Tatsuya*; Suzuki, Takahiro*

Proceedings of 10th International Particle Accelerator Conference (IPAC '19) (Internet), p.3886 - 3889, 2019/06

At the J-PARC Linac, beam conditioning and study are performed using beam dumps (BDs). To be a partition with the high vacuum section, a beam window (material Ni, 0.38 mm thick, mirror-shape) is installed upstream of the BD along the beam line. Beams that can be accepted by the beam window are about 1/50 or less of rated beam according to thermal evaluation and experience. Therefore, when using a beam dump, it is necessary not to exceed this tolerance. In a 2018 beam study, the beam e that exceeded tolerance was incident on the 0-degree dump due to human error, and the beam window was cracked. Then, this has revealed the need for protection of the beam window by hardware. Therefore, based on the existing system for monitoring the per-hour beam amount, we began to develop a system to monitor one shot beam and one second beam amount. And, we succeeded in implementing a system that protects the beam window by monitoring the beam in a short time (one shot, and for one second). In addition, the performance tests using actual beams were performed, and it was confirmed that the developed system had sufficient performance requirements to protect the beam window.

Journal Articles

Scaling of memories and crossover in glassy magnets

Samarakoon, A. M.*; Takahashi, Mitsuru*; Zhang, D.*; Yang, J.*; Katayama, Naoyuki*; Sinclair, R.*; Zhou, H. D.*; Diallo, S. O.*; Ehlers, G.*; Tennant, D. A.*; et al.

Scientific Reports (Internet), 7(1), p.12053_1 - 12053_8, 2017/09

AA2017-0448.pdf:3.45MB

 Times Cited Count:7 Percentile:50.08(Multidisciplinary Sciences)

Journal Articles

Measurement of air dose rates over a wide area around the Fukushima Dai-ichi Nuclear Power Plant through a series of car-borne surveys

Ando, Masaki; Nakahara, Yukio; Tsuda, Shuichi; Yoshida, Tadayoshi; Matsuda, Norihiro; Takahashi, Fumiaki; Mikami, Satoshi; Kinouchi, Nobuyuki; Sato, Tetsuro*; Tanigaki, Minoru*; et al.

Journal of Environmental Radioactivity, 139, p.266 - 280, 2015/01

 Times Cited Count:52 Percentile:82.76(Environmental Sciences)

A series of car-borne surveys using the KURAMA and KURAMA-II systems was conducted in a wide area in eastern Japan from June 2011 to December 2012 to evaluate the distribution of air dose rates around the Fukushima Dai-ichi Nuclear Power Plant, and to determine the time-dependent trend of decrease in air dose rates. An automated data processing system was established, which enables analyses of large amounts of data obtained with the use of about 100 units of the measurement system in a short time. The initial data for studying the migration status of radioactive cesium was obtained in the first survey, followed by the other car-borne surveys having wider measurement ranges. Comparing the measured air dose rates obtained in each survey, it was found that the decreasing trend of air dose rates measured through car-borne surveys was larger than that expected from the physical decay of radioactive cesium and that measured using NaI (Tl) survey meters around the road.

JAEA Reports

Research for spectroscopy of fuel debris using superconducting phase transition edge sensor microcalorimeter; Measurement experiment and simulated calculation (Joint research)

Takasaki, Koji; Yasumune, Takashi; Onishi, Takashi; Nakamura, Keisuke; Ishimi, Akihiro; Ito, Chikara; Osaka, Masahiko; Ono, Masashi*; Hatakeyama, Shuichi*; Takahashi, Hiroyuki*; et al.

JAEA-Research 2013-043, 33 Pages, 2014/01

JAEA-Research-2013-043.pdf:13.81MB

In the Fukushima Daiichi Nuclear Power Plant, it is assumed that the core fuels melted partially or wholly, and the normal technique of accounting for a fuel assembly is not applicable. Therefore, it is necessary to develop the transparent and rational technique of accounting in the process of collection and storage of fuel debris. In this research, an application of the superconducting phase Transition Edge Sensor microcalorimeter (TES microcalorimeter) is studied for the accounting of nuclear materials in the fuel debris. It is expected that the detailed information of nuclear materials and fission products in fuel debris is obtained by using a high-resolution characteristic of TES microcalorimeter. In this report, the principle of TES microcalorimeter, the measurement experiment using TES in JAEA, and the simulated calculation using the EGS5 code system are summarized.

Journal Articles

Crystal morphology-dependent graft polymerization in poly(ether ether ketone) films

Hasegawa, Shin; Takahashi, Shuichi*; Iwase, Hiroki*; Koizumi, Satoshi; Onuma, Masato*; Maekawa, Yasunari

Polymer, 54(12), p.2895 - 2900, 2013/05

 Times Cited Count:9 Percentile:29.18(Polymer Science)

Radiation-induced graft polymerization of sulfo-containing styrene derivatives into crystalline poly(ether ether ketone) (PEEK) substrates was carried out to prepare thermally and mechanically stable polymer electrolyte membranes based on an aromatic hydrocarbon polymer, so-called "super-engineering plastics". Graft polymerization of the sulfo-containing styrene, ethyl 4-styrenesulfonate (E4S) into PEEK substrates with degrees of crystallinity (DC) of 11 - 26% gradually progressed, achieving a grafting degree of more than 50% after 72 hours, whereas graft polymerization of the substrates with DC above 26% did not proceed. When morphological change in these films were measured by SAXS, PEEK films with DC larger than 26% showed a new peak at d=14 nm, corresponding to lamella structure. Thus, the suppression of graft polymerization of PEEK films with DC above 26% was due to obstruct of monomer diffusion by the formation of the oriented lamella structure.

Journal Articles

Synthesis of copolymer grafts containing sulfoalkyl and hydrophilic groups in polymer electrolyte membranes

Enomoto, Kazuyuki; Takahashi, Shuichi; Rohani, R.; Maekawa, Yasunari

Journal of Membrane Science, 415-416, p.36 - 41, 2012/10

 Times Cited Count:15 Percentile:46.12(Engineering, Chemical)

Polymer electrolyte membranes (PEM) consisting of ion conducting alkylsulfonic acid and hydroxyl groups were successfully synthesized by radiation-induced graft polymerization of vinyl acetate (VAc) into a poly(ethylene-$$co$$-tetrafluoroethylene) (ETFE) film, followed by alkylsulfonation with 1,3-propanesulfone. The prepared PEM showed higher conductivity under 30% relative humidity at 80$$^{circ}$$C than that of the conventional poly(styrenesulfonic acid)-grafted ETFE. Furthermore, the prepared PEM also showed better mechanical properties than those of Nafion. Thus, the PEM with hydroxyl groups possesses sufficient mechanical and electrochemical properties, required for a fuel cell, operating at a high temperature and low humidity.

Journal Articles

Uniaxial-pressure control of magnetic phase transitions in a frustrated magnet CuFe$$_{1-x}$$Ga$$_{x}$$O$$_{2}$$ (x =0, 0.018)

Nakajima, Taro*; Mitsuda, Setsuo*; Takahashi, Keiichiro*; Yoshitomi, Keisuke*; Masuda, Kazuya*; Kaneko, Chikafumi*; Homma, Yuki*; Kobayashi, Satoru*; Kitazawa, Hideaki*; Kosaka, Masashi*; et al.

Journal of the Physical Society of Japan, 81(9), p.094710_1 - 094710_8, 2012/09

Journal Articles

Uniaxial-pressure control of magnetic phase transitions in a frustrated magnet CuFe$$_{1-x}$$Ga$$_{x}$$O$$_{2}$$ ($$x$$ = 0, 0.018)

Nakajima, Taro*; Mitsuda, Setsuo*; Takahashi, Keiichiro*; Yoshitomi, Keisuke*; Masuda, Kazuya*; Kaneko, Chikafumi*; Homma, Yuki*; Kobayashi, Satoru*; Kitazawa, Hideaki*; Kosaka, Masashi*; et al.

Journal of the Physical Society of Japan, 81(9), p.094710_1 - 094710_8, 2012/09

 Times Cited Count:13 Percentile:63.29(Physics, Multidisciplinary)

Journal Articles

Beam position monitor system of J-PARC RCS

Hayashi, Naoki; Kawase, Masato; Hatakeyama, Shuichiro; Hiroki, Seiji; Saeki, Riuji; Takahashi, Hiroki; Teruyama, Yuzo*; Toyokawa, Ryoji*; Arakawa, Dai*; Hiramatsu, Shigenori*; et al.

Nuclear Instruments and Methods in Physics Research A, 677, p.94 - 106, 2012/06

 Times Cited Count:12 Percentile:66.54(Instruments & Instrumentation)

A beam position monitor (BPM) system at J-PARC RCS is described. The J-PARC RCS is a rapid-cycling proton synchrotron and its designed beam power is 1 MW. A diameter of the BPM detector is larger than 250 mm, however the system has to measure the beam position very accurately. The system should work not only for the high intensity but also for lower intensity. There are 54 BPM around the ring and most of them are placed inside steering magnets because of quite limited space. The BPM detector is an electro static type and it has four electrodes, and a pair of electrode gives a good linear response with diagonal cut shape to detect the charge center precisely. The signal processing unit, which is equipped with 14-bit 40 MSPS ADC and 600 MHz DSP, has been developed. They are controlled via shared memory space and EPICS. It is capable to record full 25 Hz pulse data for averaged mode and it could also store whole waveform data for further analysis, like turn-by-turn position calculation.

Journal Articles

Systematic measurement of lineal energy distributions for proton, He and Si ion beams over a wide energy range using a wall-less tissue equivalent proportional counter

Tsuda, Shuichi; Sato, Tatsuhiko; Takahashi, Fumiaki; Satoh, Daiki; Sasaki, Shinichi*; Namito, Yoshihito*; Iwase, Hiroshi*; Ban, Shuichi*; Takada, Masashi*

Journal of Radiation Research, 53(2), p.264 - 271, 2012/04

 Times Cited Count:14 Percentile:55.77(Biology)

Deposit energy distribution in microscopic site is basic information for understanding of biological effects of energetic heavy ion beams. To estimate RBE, lineal energy, $$y$$, can be an appropriate physical index. In this work, a wall-less tissue equivalent proportional counter has been designed and used for the measurement of $$y$$ distributions, $$y$$$$f$$($$y$$), for 160 MeV H, 150 MeV/u He, 290 MeV/u C, 490 MeV/u Si and 500 MeV/u Ar. Data of $$y$$$$f$$($$y$$) were also obtained in the wide range of LET. The dose-means of $$y$$, $$overline{y}$$$$_{D}$$, were compared with those calculated by the microdosimetric function of PHITS. It is found that the calculated $$y$$$$f$$($$y$$) and $$overline{y}$$$$_{D}$$ agree fairly well with those measured. The values of $$overline{y}$$$$_{D}$$ are larger than those of LET less than $$sim$$10 keV/$$mu$$m because of the discrete energy deposition by delta rays, while the relation is reversed above 10 keV/$$mu$$m. The results indicate that care should be taken in the difference between $$overline{y}$$$$_{D}$$ and LET when the values of RBE of energetic heavy ions are estimated.

Journal Articles

A Novel characterization method for graft-polymer structures chemically attached on thermally stable polymer films

Enomoto, Kazuyuki; Takahashi, Shuichi; Maekawa, Yasunari

Macromolecular Chemistry and Physics, 213(1), p.72 - 78, 2012/01

 Times Cited Count:10 Percentile:33.08(Polymer Science)

Most polymer grafts in grafted polymer films obtained by radiation-induced solid graft polymerization have not been analyzed in detail due to difficulties in isolation of the grafts without structural decomposition. We report herein a novel structural and molecular weight characterization method for polymer grafts chemically attached to thermally and chemically stable polymer substrates, based on swelling-induced graft detachment in hot water. The polymer grafts prepared by radiation-induced polymerization of alkyl acrylate into poly(ethylene-co-tetrafluoroethylene) (ETFE) followed by a sulfonation reaction were found to have a ternary copolymer structure whose monomer units contained -COOH, -SO$$_{3}$$H, or both.

Journal Articles

Measurement of lineal energy distribution of heavy ion using wall-less tissue equivalent proportional counter

Tsuda, Shuichi; Sato, Tatsuhiko; Takahashi, Fumiaki; Satoh, Daiki; Sasaki, Shinichi*; Namito, Yoshihito*; Iwase, Hiroshi*; Ban, Shuichi*; Takada, Masashi*

KEK Proceedings 2011-8, p.100 - 108, 2011/12

Deposit energy distribution in microscopic site is basic information for understanding of biological effects of energetic heavy ion beams. To estimate RBE, lineal energy, y, can be an appropriate physical index. In this work, a wall-less tissue equivalent proportional counter has been designed and used for the measurement of y distributions, $$yf(y)$$, for 160 MeV H, 150 MeV/u He and 490 MeV/u Si ion beams. Data of $$yf(y)$$ and the dose-means of $$y$$, $$overline{y}_D$$, were compared with those calculated by the microdosimetric function of PHITS. It is found that the calculated $$yf(y)$$ and $$overline{y}_D$$ agree fairly well with those measured, as well as the already reported result of 290 MeV/u carbon beam.

Journal Articles

Measurement of deposit energy distribution of heavy ions using a wall-less tissue equivalent proportional counter

Tsuda, Shuichi; Sato, Tatsuhiko; Satoh, Daiki; Takahashi, Fumiaki; Sasaki, Shinichi*; Namito, Yoshihito*; Sanami, Toshiya*; Saito, Kiwamu*; Takada, Masashi*

HIMAC-136, p.219 - 220, 2011/11

Measurements of lineal energy distribution were employed using 160 MeV proton and 490 MeV/u Si. The calculated $$yf(y)$$ by PHITS and $$overline{y}_D$$ agree fairly well with those measured. The LET dependence of $$overline{y}_D$$ was obtained from 3 to 300 keV/um in this project.

Journal Articles

Degradation manner of polymer grafts chemically attached on thermally stable polymer films; Swelling-induced detachment of hydrophilic grafts from hydrophobic polymer substrates in aqueous media

Enomoto, Kazuyuki*; Takahashi, Shuichi*; Iwase, Takanori*; Yamashita, Takashi*; Maekawa, Yasunari

Journal of Materials Chemistry, 21(25), p.9343 - 9349, 2011/07

 Times Cited Count:38 Percentile:72.35(Chemistry, Physical)

The degradation manner of graft-type polymer electrolyte membranes consisting of hydrophilic poly(styrenesulfonic acid) (PSSA) graft polymers (grafts) and thermally and mechanically stable hydrophobic polymer substrates was examined in hot water. Severe weight loss was observed in PSSA-grafted cPTFE and ETFE films but not in a PSSA-grafted PEEK film. The decomposed extracts in water were characterized as PSSA during the whole course of degradation, clearly showing that the PSSA grafts detached from the fluorinated substrates without decomposition or scission of graft polymer chains. This is quite a new degradation manner for graft-type polymer electrolyte membranes; namely, hydrophilic PSSA grafts detach from hydrophobic polymer substrates due to swelling-induced stress at the interfacial boundary in the grafted films.

Journal Articles

AMATERAS; A Cold-neutron disk chopper spectrometer

Nakajima, Kenji; Kawamura, Seiko; Kikuchi, Tatsuya; Nakamura, Mitsutaka; Kajimoto, Ryoichi; Inamura, Yasuhiro; Takahashi, Nobuaki; Aizawa, Kazuya; Suzuya, Kentaro; Shibata, Kaoru; et al.

Journal of the Physical Society of Japan, 80(Suppl.B), p.SB028_1 - SB028_6, 2011/05

 Times Cited Count:125 Percentile:95.7(Physics, Multidisciplinary)

AMATERAS is a cold-neutron disk-chopper spectrometer in MLF, J-PARC. The construction of main part of the spectrometer has been completed in spring of 2009. Soon after that, we have started the commissioning work on AMATERAS. The performance of AMATERAS has been examined by test experiments in the course of commissioning. In parallel to these works, we have started the user program on AMATERAS from December 2009 and we are getting scientific results from our spectrometer. In this presentation, we will report the current status of AMATERAS including the results of performance tests and some of examples of scientific outputs.

129 (Records 1-20 displayed on this page)