Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Initialising ...
Fujita, Manami; Hasegawa, Shoichi; Hosomi, Kenji; Ichikawa, Masaya; Ichikawa, Yudai; Kim, S.; Nanamura, Takuya; Sako, Hiroyuki; Tamura, Hirokazu; Yamamoto, Takeshi; et al.
Progress of Theoretical and Experimental Physics (Internet), 2022(12), p.123D01_1 - 123D01_17, 2022/12
Times Cited Count:0 Percentile:0.01(Physics, Multidisciplinary)Yamamoto, Takeshi; Fujita, Manami; Gogami, Toshiyuki*; Harada, Takeshi*; Hayakawa, Shuhei*; Hosomi, Kenji; Ichikawa, Yudai; Ishikawa, Yuji*; Kamata, K.*; Kanauchi, H.*; et al.
EPJ Web of Conferences, 271, p.03001_1 - 03001_5, 2022/11
Fujita, Manami; Hosomi, Kenji; Ishikawa, Yuji*; Kanauchi, H.*; Koike, Takeshi*; Ogura, Yu*; Tamura, Hirokazu; Tanida, Kiyoshi; Ukai, Mifuyu*; Yamamoto, Takeshi
Nuclear Instruments and Methods in Physics Research A, 1042, p.167439_1 - 167439_9, 2022/11
Times Cited Count:2 Percentile:53.91(Instruments & Instrumentation)Yee-Rendon, B.; Meigo, Shinichiro; Kondo, Yasuhiro; Tamura, Jun; Nakano, Keita; Maekawa, Fujio; Iwamoto, Hiroki; Sugawara, Takanori; Nishihara, Kenji
Journal of Instrumentation (Internet), 17(10), p.P10005_1 - P10005_21, 2022/10
Times Cited Count:0 Percentile:0(Instruments & Instrumentation)To reduce the hazard of minor actinides in nuclear waste, JAEA proposed an accelerator-driven subcritical system (JAEA-ADS). The JAEA-ADS drives a subcritical reactor 800-MWth by 30-MW proton linac delivering the beam to the spallation neutron target inside the reactor. The beam transport to the target (BTT) is required for high-beam power stability and low peak density to ensure the integrity of the beam window. Additionally, the design should have compatible with the reactor design for the maintenance and replacement of the fuel and the beam window. A robust-compact BTT design was developed through massive multiparticle simulations. The beam optics was optimized to guarantee beam window feasibility requirements by providing a low peak density of less than 0.3 A/mm. Beam stability was evaluated and improved by simultaneously applying the linac's input beam and element errors. The input beam errors to the reactor were based on the beam degradation obtained by implementing fast fault compensation in the linac. Those results show that the BTT fulfills the requirements for JAEA-ADS.
Miwa, Koji*; Fujita, Manami; Hasegawa, Shoichi; Hosomi, Kenji; Ichikawa, Yudai; Imai, Kenichi*; Nanamura, Takuya; Naruki, Megumi; Sako, Hiroyuki; Sato, Susumu; et al.
Physical Review C, 104(4), p.045204_1 - 045204_20, 2021/10
Times Cited Count:12 Percentile:89.15(Physics, Nuclear)Yoshida, Junya; Akaishi, Takaya; Fujita, Manami; Hasegawa, Shoichi; Hashimoto, Tadashi; Hosomi, Kenji; Ichikawa, Masaya; Ichikawa, Yudai; Imai, Kenichi*; Kim, S.; et al.
JPS Conference Proceedings (Internet), 33, p.011112_1 - 011112_8, 2021/03
Sakao, Tamao*; Fujita, Manami; Hasegawa, Shoichi; Hosomi, Kenji; Ichikawa, Masaya; Ichikawa, Yudai; Imai, Kenichi*; Nanamura, Takuya; Naruki, Megumi; Sako, Hiroyuki; et al.
JPS Conference Proceedings (Internet), 33, p.011133_1 - 011133_6, 2021/03
Hayakawa, Shuhei; Fujita, Manami; Hasegawa, Shoichi; Hashimoto, Tadashi; Hosomi, Kenji; Ichikawa, Yudai; Imai, Kenichi*; Nanamura, Takuya; Naruki, Megumi; Sako, Hiroyuki; et al.
Physical Review Letters, 126(6), p.062501_1 - 062501_6, 2021/02
Times Cited Count:34 Percentile:95.34(Physics, Multidisciplinary)Gogami, Toshiyuki*; Fujita, Manami; Hasegawa, Shoichi; Hosomi, Kenji; Imai, Kenichi*; Ichikawa, Yudai; Nanamura, Takuya; Naruki, Megumi; Sako, Hiroyuki; Sato, Susumu; et al.
Journal of Physics; Conference Series, 1643, p.012133_1 - 012133_6, 2020/12
Times Cited Count:2 Percentile:84.57(Astronomy & Astrophysics)Miwa, Koji*; Fujita, Manami; Hasegawa, Shoichi; Hosomi, Kenji; Ichikawa, Masaya; Ichikawa, Yudai; Imai, Kenichi*; Nanamura, Takuya; Naruki, Megumi; Sako, Hiroyuki; et al.
Journal of Physics; Conference Series, 1643, p.012174_1 - 012174_6, 2020/12
Times Cited Count:2 Percentile:84.57(Astronomy & Astrophysics)Sue, Yuki*; Yotsuzuka, Mai*; Futatsukawa, Kenta*; Hasegawa, Kazuo; Iijima, Toru*; Iinuma, Hiromi*; Inami, Kenji*; Ishida, Katsuhiko*; Kawamura, Naritoshi*; Kitamura, Ryo; et al.
Physical Review Accelerators and Beams (Internet), 23(2), p.022804_1 - 022804_7, 2020/02
Times Cited Count:2 Percentile:25.94(Physics, Nuclear)A destructive monitor to measure the longitudinal bunch width of a low-energy and low-intensity muon beam was developed. This bunch-width monitor (BWM) employed microchannel plates to detect a single muon with high time resolution. In addition, constant-fraction discriminators were adopted to suppress the time-walk effect. The time resolution was measured to be 65 ps in rms using a picosecond-pulsed laser. This resolution satisfied the requirements of the muon linac of the J-PARC E34 experiment. We measured the bunch width of negative-muonium ions accelerated with a radio-frequency quadrupole using the BWM. The bunch width was successfully measured to be 54 11 ns, which is consistent with the simulation.
Otani, Masashi*; Fukao, Yoshinori*; Futatsukawa, Kenta*; Kawamura, Naritoshi*; Matoba, Shiro*; Mibe, Tsutomu*; Miyake, Yasuhiro*; Shimomura, Koichiro*; Yamazaki, Takayuki*; Hasegawa, Kazuo; et al.
Journal of Physics; Conference Series, 1350, p.012067_1 - 012067_6, 2019/12
Times Cited Count:2 Percentile:73.22(Physics, Particles & Fields)Negative muonium atom (ee, Mu) has unique features stimulating potential interesting for several scientific fields. Since its discovery in late 1980's in vacuum, it has been discussed that the production efficiency would be improved using a low-work function material. C12A7 was a well-known insulator as a constituent of alumina cement, but was recently confirmed to exhibit electric conductivity by electron doping. The C12A7 electride has relatively low-work function (2.9 eV). In this paper, the negative muonium production measurement with several materials including a C12A7 electride film will be presented. Measured production rate of the Mu were 10/s for all the Al, electride, and SUS target. Significant enhancement on electride target was not observed, thus it is presumed that the surface condition should be more carefully treated. There was no material dependence of the Mu averaged energy: it was 0.20.1keV.
Nakada, Yoshiyuki*; Hasegawa, Shoichi; Hayakawa, Shuhei*; Hosomi, Kenji; Ichikawa, Yudai; Imai, Kenichi; Nanamura, Takuya*; Naruki, Megumi*; Sako, Hiroyuki; Sato, Susumu; et al.
JPS Conference Proceedings (Internet), 26, p.023024_1 - 023024_5, 2019/11
Yang, S. B.*; Hasegawa, Shoichi; Hayakawa, Shuhei*; Hosomi, Kenji; Ichikawa, Yudai; Imai, Kenichi; Sako, Hiroyuki; Sato, Susumu; Tamura, Hirokazu*; Tanida, Kiyoshi; et al.
JPS Conference Proceedings (Internet), 26, p.023015_1 - 023015_5, 2019/11
Honda, Ryotaro*; Hasegawa, Shoichi; Hayakawa, Shuhei; Hosomi, Kenji; Imai, Kenichi; Ichikawa, Yudai; Nanamura, Takuya; Naruki, Megumi; Sako, Hiroyuki; Sato, Susumu; et al.
JPS Conference Proceedings (Internet), 26, p.023014_1 - 023014_4, 2019/11
Nakagawa, Manami*; Hasegawa, Shoichi; Hayakawa, Shuhei; Hosomi, Kenji; Ichikawa, Yudai; Imai, Kenichi; Sako, Hiroyuki; Sato, Susumu; Tamura, Hirokazu; Tanida, Kiyoshi; et al.
JPS Conference Proceedings (Internet), 26, p.023005_1 - 023005_3, 2019/11
Koike, Takeshi*; Hasegawa, Shoichi; Hayakawa, Shuhei*; Hosomi, Kenji; Ichikawa, Yudai; Imai, Kenichi; Sako, Hiroyuki; Sato, Susumu; Sugimura, Hitoshi; Tamura, Hirokazu; et al.
AIP Conference Proceedings 2130, p.020011_1 - 020011_9, 2019/07
Times Cited Count:2 Percentile:73.22(Physics, Nuclear)Nagae, Tomofumi*; Ekawa, Hiroyuki; Hasegawa, Shoichi; Hayakawa, Shuhei; Hosomi, Kenji; Ichikawa, Yudai; Imai, Kenichi; Kimbara, Shinji; Nanamura, Takuya*; Naruki, Megumi; et al.
AIP Conference Proceedings 2130, p.020015_1 - 020015_9, 2019/07
Times Cited Count:12 Percentile:98.33(Physics, Nuclear)Sue, Yuki*; Iijima, Toru*; Inami, Kenji*; Yotsuzuka, Mai*; Iinuma, Hiromi*; Nakazawa, Yuga*; Otani, Masashi*; Kawamura, Naritoshi*; Shimomura, Koichiro*; Futatsukawa, Kenta*; et al.
Proceedings of 16th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.55 - 60, 2019/07
The result of bunch size measurement of muon accelerated by RFQ up to 89 keV is presented in this paper. A four-stage muon linac for precise measurement of muon property is under construction in the J-PARC. The demonstration of the first muon RF acceleration with an RFQ linac was conducted and the transverse profile of the accelerated muons was measured in 2017. As one of the remaining issues for the beam diagnostic system, the longitudinal beam profile after the RFQ should be measured to match the profile to the designed acceptance of the subsequent accelerator. For this purpose, the new longitudinal beam monitor using the microchannel plate is under development. The time resolution of the monitor aims to be around 30 to 40 ps corresponding to 1% of a period of an operating frequency of the accelerator, which is 324 MHz. On November 2018, the bunch size of accelerated negative muonium ion of 89 keV with the RFQ was measured using this monitor at the J-PARC MLF. The measured bunch width is ns, which is consistent with the simulation.
Yotsuzuka, Mai*; Iijima, Toru*; Iinuma, Hiromi*; Inami, Kenji*; Otani, Masashi*; Kawamura, Naritoshi*; Kitamura, Ryo; Kondo, Yasuhiro; Saito, Naohito; Shimomura, Koichiro*; et al.
Proceedings of 16th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.814 - 817, 2019/07
The J-PARC E34 experiment aims to measure the muon anomalous magnetic moment and the electric dipole moment with a high precision. In this experiment, thermal muonium is produced and ionized by laser resonance to generate ultra-slow muons, which are then accelerated in a multistage muon linac. In order to satisfy the experimental requirements, suppression of the emittance growth during the acceleration is necessary. Because the main cause of the emittance growth is beam mismatching between the accelerating stages, the transverse and longitudinal beam monitoring is important. The longitudinal beam monitor has to measure the bunch length with the resolution equivalent to tens of picoseconds, which is 1% of the acceleration phase of 324 MHz. In addition, it should be sensitive to single muon because the beam intensity is limited during the commissioning phase. To realize above requirements, we are developing a longitudinal beam monitor with a micro channel plate, and the test bench to evaluate the monitor performance. So far, the time resolution of the beam monitor was obtained to be 65 ps in RMS including the jitter on the test bench. We also succeeded in measuring the longitudinal bunch size of the muon beam accelerated by RFQ using the beam monitor. In this paper, the results of the performance evaluation for this beam monitor are reported.