Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 74

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Birchite Cd$$_{2}$$Cu$$_{2}$$(PO$$_{4}$$)$$_{2}$$SO$$_{4}$$ $$cdot$$ 5H$$_{2}$$O as a model antiferromagnetic spin-1/2 Heisenberg $${it J}$$$$_{1}$$-$${it J}$$$$_{2}$$ chain

Fujihara, Masayoshi; Jeschke, H. O.*; Morita, Katsuhiro*; Kuwai, Tomohiko*; Koda, Akihiro*; Okabe, Hirotaka*; Matsuo, Akira*; Kindo, Koichi*; Mitsuda, Setsuo*

Physical Review Materials (Internet), 6(11), p.114408_1 - 114408_8, 2022/11

 Times Cited Count:0 Percentile:0(Materials Science, Multidisciplinary)

$${it S}$$ = 1/2 Heisenberg $${it J}$$$$_{1}$$-$${it J}$$$$_{2}$$ chain antiferromagnets have been investigated extensively due to their exotic magnetic states. Here, we report the magnetic behavior of birchite Cd$$_{2}$$Cu$$_{2}$$(PO$$_{4}$$)$$_{2}$$SO$$_{4}$$$$cdot$$5H$$_{2}$$O and its effective spin model. Experimental studies by magnetic susceptibility, magnetization, heat capacity, and $$mu$$SR measurements indicate the absence of long-range order down to 0.4 K. Theoretical studies reveal that birchite is a model compound for the $${it J}$$$$_{1}$$-$${it J}$$$$_{2}$$ antiferromagnetic chain: the intrachain interactions $${it J}$$$$_{1}$$ and $${it J}$$$$_{2}$$ are antiferromagnetic and their magnitude is about 100 times larger than the interchain interactions. The magnitude of $${it J}$$$$_{2}$$ is two to three times larger than that of $${it J}$$$$_{1}$$, thus the spin gap is expected to be only a few percent of that of $${it J}$$$$_{1}$$. The temperature dependence of the specific heat shows a broad peak at about 1 K ($$simeq$$ 0.036 $${it J}$$$$_{1}$$), which suggests the presence of a spin gap.

Journal Articles

Rabi-oscillation spectroscopy of the hyperfine structure of muonium atoms

Nishimura, Shoichiro*; Torii, Hiroyuki*; Fukao, Yoshinori*; Ito, Takashi; Iwasaki, Masahiko*; Kanda, Sotaro*; Kawagoe, Kiyotomo*; Kawall, D.*; Kawamura, Naritoshi*; Kurosawa, Noriyuki*; et al.

Physical Review A, 104(2), p.L020801_1 - L020801_6, 2021/08

 Times Cited Count:13 Percentile:83.13(Optics)

Journal Articles

Gapless spin liquid in a square-kagome lattice antiferromagnet

Fujihara, Masayoshi*; Morita, Katsuhiro*; Mole, R.*; Mitsuda, Setsuo*; Toyama, Takami*; Yano, Shinichiro*; Yu, D.*; Sota, Shigetoshi*; Kuwai, Tomohiko*; Koda, Akihiro*; et al.

Nature Communications (Internet), 11, p.3429_1 - 3429_7, 2020/07

 Times Cited Count:37 Percentile:90.63(Multidisciplinary Sciences)

Journal Articles

Magnetic, thermal, and neutron diffraction studies of a coordination polymer; bis(glycolato)cobalt(II)

Nakane, Tomohiro*; Yoneyama, Shota*; Kodama, Takeshi*; Kikuchi, Koichi*; Nakao, Akiko*; Ohara, Takashi; Higashinaka, Ryuji*; Matsuda, Tatsuma*; Aoki, Yuji*; Fujita, Wataru*

Dalton Transactions (Internet), 48(1), p.333 - 338, 2019/01

 Times Cited Count:2 Percentile:11.34(Chemistry, Inorganic & Nuclear)

Journal Articles

New precise measurements of muonium hyperfine structure at J-PARC MUSE

Strasser, P.*; Abe, Mitsushi*; Aoki, Masaharu*; Choi, S.*; Fukao, Yoshinori*; Higashi, Yoshitaka*; Higuchi, Takashi*; Iinuma, Hiromi*; Ikedo, Yutaka*; Ishida, Katsuhiko*; et al.

EPJ Web of Conferences, 198, p.00003_1 - 00003_8, 2019/01

 Times Cited Count:13 Percentile:99.06(Quantum Science & Technology)

Journal Articles

Decontamination of radioactive concrete waste and reuse of aggregate using pulsed power technology

Sakamoto, Hiroyuki*; Akagi, Yosuke*; Yamada, Kazuo*; Tachi, Yukio; Fukuda, Daisuke*; Ishimatsu, Koichi*; Matsuda, Mikiya*; Saito, Nozomi*; Uemura, Jitsuya*; Namihira, Takao*; et al.

Nihon Genshiryoku Gakkai Wabun Rombunshi, 17(2), p.57 - 66, 2018/05

Concrete debris contaminated with radioactive cesium and other nuclides have been generated from the accident in the Fukushima Dai-ichi Nuclear Power Plant and there will be generated due to the decommissioning of nuclear power plants in the future. Although conventional decontamination techniques are effective for flat concrete surfaces such as floors and walls, it is not clear what techniques to apply for decontaminating radioactive concrete debris. In this study, focusing on a pulsed power discharge technique, fundamental experimental works were carried out. Decontamination of concrete by applying the aggregate recycling technique using the pulsed power discharge technique was evaluated by measuring radioactivity of aggregate and sludge separated from the contaminated concrete. The results suggest that the separation into aggregate and sludge of the contaminated concrete debris could achieve decontamination and volume reduction of the radioactive concrete debris.

Journal Articles

New precise measurement of muonium hyperfine structure interval at J-PARC

Ueno, Yasuhiro*; Aoki, Masaharu*; Fukao, Yoshinori*; Higashi, Yoshitaka*; Higuchi, Takashi*; Iinuma, Hiromi*; Ikedo, Yutaka*; Ishida, Katsuhiko*; Ito, Takashi; Iwasaki, Masahiko*; et al.

Hyperfine Interactions, 238(1), p.14_1 - 14_6, 2017/11

 Times Cited Count:3 Percentile:86.59(Physics, Atomic, Molecular & Chemical)

Journal Articles

Magnetic structure and dispersion relation of the $$S$$=1/2 quasi-one-dimensional Ising-like antiferromagnet BaCo$$_{2}$$V$$_{2}$$O$$_{8}$$ in a transverse magnetic field

Matsuda, Masaaki*; Onishi, Hiroaki; Okutani, Akira*; Ma, J.*; Agrawal, H.*; Hong, T.*; Pajerowski, D. M.*; Copley, J. R. D.*; Okunishi, Koichi*; Mori, Michiyasu; et al.

Physical Review B, 96(2), p.024439_1 - 024439_8, 2017/07

 Times Cited Count:12 Percentile:51.46(Materials Science, Multidisciplinary)

Journal Articles

New muonium HFS measurements at J-PARC/MUSE

Strasser, P.*; Aoki, Masaharu*; Fukao, Yoshinori*; Higashi, Yoshitaka*; Higuchi, Takashi*; Iinuma, Hiromi*; Ikedo, Yutaka*; Ishida, Katsuhiko*; Ito, Takashi; Iwasaki, Masahiko*; et al.

Hyperfine Interactions, 237(1), p.124_1 - 124_9, 2016/12

 Times Cited Count:7 Percentile:90.97(Physics, Atomic, Molecular & Chemical)

Journal Articles

Radiation response of silicon carbide metal-oxide-semiconductor transistors in high dose region

Oshima, Takeshi; Yokoseki, Takashi; Murata, Koichi; Matsuda, Takuma; Mitomo, Satoshi; Abe, Hiroshi; Makino, Takahiro; Onoda, Shinobu; Hijikata, Yasuto*; Tanaka, Yuki*; et al.

Japanese Journal of Applied Physics, 55(1S), p.01AD01_1 - 01AD01_4, 2016/01

 Times Cited Count:14 Percentile:54.92(Physics, Applied)

Journal Articles

X-ray absorption spectroscopy in the heavy Fermion compound $$alpha$$-YbAlB$$_4$$ at high magnetic fields

Terashima, Taku*; Matsuda, Yasuhiro*; Kuga, Kentaro*; Suzuki, Shintaro*; Matsumoto, Yosuke*; Nakatsuji, Satoru*; Kondo, Akihiro*; Kindo, Koichi*; Kawamura, Naomi*; Mizumaki, Masaichiro*; et al.

Journal of the Physical Society of Japan, 84(11), p.114715_1 - 114715_4, 2015/11

 Times Cited Count:4 Percentile:34.89(Physics, Multidisciplinary)

Journal Articles

A Development of super radiation-hardened power electronics using silicon carbide semiconductors; Toward MGy-class radiation resistivity

Hijikata, Yasuto*; Mitomo, Satoshi*; Matsuda, Takuma*; Murata, Koichi*; Yokoseki, Takashi*; Makino, Takahiro; Takeyama, Akinori; Onoda, Shinobu; Okubo, Shuichi*; Tanaka, Yuki*; et al.

Proceedings of 11th International Workshop on Radiation Effects on Semiconductor Devices for Space Applications (RASEDA-11) (Internet), p.130 - 133, 2015/11

Journal Articles

Effect of humidity and temperature on the radiation response of SiC MOSFETs

Takeyama, Akinori; Matsuda, Takuma; Yokoseki, Takashi; Mitomo, Satoshi; Murata, Koichi; Makino, Takahiro; Onoda, Shinobu; Tanaka, Yuki*; Kandori, Mikio*; Yoshie, Toru*; et al.

Proceedings of 11th International Workshop on Radiation Effects on Semiconductor Devices for Space Applications (RASEDA-11) (Internet), p.134 - 137, 2015/11

Journal Articles

Measurements and evaluations of air dose rates around Fukushima, 4; Practical aspects of air dose rate measurements in the environment

Tsuda, Shuichi; Yoshida, Tadayoshi; Ando, Masaki; Matsuda, Norihiro; Mikami, Satoshi; Tanigaki, Minoru*; Okumura, Ryo*; Takamiya, Koichi*; Sato, Nobuhiro*; Seki, Akiyuki; et al.

Radioisotopes, 64(4), p.275 - 289, 2015/04

This article provides practically useful information on air dose rate measurements in the environments. The basic requirements for the accurate measurements are described giving actual data. The characteristics and some measured results are shown for reliable methods which are widely used in the environmental radiation measurements. Further, information is given on internet sites where air dose rates and related data obtained by official organizations can be browsed.

Journal Articles

Synchrotron X-ray spectroscopy study on the valence state and magnetization in $$alpha$$-YbAl$$_{1-x}$$Fe$$_x$$B$$_4$$ ($$x=0.115$$) at low temperatures and high magnetic fields

Terashima, Taku*; Matsuda, Yasuhiro*; Kuga, Kentaro*; Suzuki, Shintaro*; Matsumoto, Yosuke*; Nakatsuji, Satoru*; Kondo, Akihiro*; Kindo, Koichi*; Kawamura, Naomi*; Mizumaki, Masaichiro*; et al.

Journal of Physics; Conference Series, 592(1), p.012020_1 - 012020_6, 2015/03

 Times Cited Count:1 Percentile:43.19(Physics, Atomic, Molecular & Chemical)

Valence fluctuation phenomena in rare-earth intermetallic compounds have attracted attention because the quantum criticality of the valence transition has been proposed theoretically. Recently, it was found that $$beta$$-YbAlB$$_4$$ shows quantum criticality without tuning and has a strong mixed-valence state. In this study, we measured the magnetization curve and X-ray magnetoabsorption in $$alpha$$-YbAl$$_{1-x}$$Fe$$_x$$B$$_4$$ ($$x=0.115$$), which is a locally isostructural polymorph of $$beta$$-YbAlB$$_4$$. The magnetization and X-ray experiments were performed in fields up to 55 and 40 T, respectively. A small increase in the Yb valence was observed at fields where the magnetization curve exhibited a change in slope.

Journal Articles

Measurement of air dose rates over a wide area around the Fukushima Dai-ichi Nuclear Power Plant through a series of car-borne surveys

Ando, Masaki; Nakahara, Yukio; Tsuda, Shuichi; Yoshida, Tadayoshi; Matsuda, Norihiro; Takahashi, Fumiaki; Mikami, Satoshi; Kinouchi, Nobuyuki; Sato, Tetsuro*; Tanigaki, Minoru*; et al.

Journal of Environmental Radioactivity, 139, p.266 - 280, 2015/01

 Times Cited Count:52 Percentile:82.76(Environmental Sciences)

A series of car-borne surveys using the KURAMA and KURAMA-II systems was conducted in a wide area in eastern Japan from June 2011 to December 2012 to evaluate the distribution of air dose rates around the Fukushima Dai-ichi Nuclear Power Plant, and to determine the time-dependent trend of decrease in air dose rates. An automated data processing system was established, which enables analyses of large amounts of data obtained with the use of about 100 units of the measurement system in a short time. The initial data for studying the migration status of radioactive cesium was obtained in the first survey, followed by the other car-borne surveys having wider measurement ranges. Comparing the measured air dose rates obtained in each survey, it was found that the decreasing trend of air dose rates measured through car-borne surveys was larger than that expected from the physical decay of radioactive cesium and that measured using NaI (Tl) survey meters around the road.

Journal Articles

Online full two-dimensional imaging of pulsed muon beams at J-PARC MUSE using a gated image intensifier

Ito, Takashi; Toyoda, Akihisa*; Higemoto, Wataru; Tajima, Minori*; Matsuda, Yasuyuki*; Shimomura, Koichiro*

Nuclear Instruments and Methods in Physics Research A, 754, p.1 - 9, 2014/08

 Times Cited Count:7 Percentile:48.36(Instruments & Instrumentation)

Journal Articles

Temperature and magnetic field dependent Yb valence in YbRh$$_2$$Si$$_2$$ observed by X-ray absorption spectroscopy

Nakai, Hirohito*; Ebihara, Takao*; Tsutsui, Satoshi*; Mizumaki, Masaichiro*; Kawamura, Naomi*; Michimura, Shinji*; Inami, Toshiya; Nakamura, Toshiyuki*; Kondo, Akihiro*; Kindo, Koichi*; et al.

Journal of the Physical Society of Japan, 82(12), p.124712_1 - 124712_5, 2013/12

 Times Cited Count:9 Percentile:53.63(Physics, Multidisciplinary)

The temperature and magnetic field dependences of Yb valence were observed in the heavy fermion compoundYbRh$$_2$$Si$$_2$$ by X-ray absorption spectroscopy. The measurements revealed that the Yb valence decreases with decreasing temperature in the range from 200 to 2 K and increases with increasing magnetic field in the range from 0 to 33 T without showing an abrupt change in the Yb valence. The Yb valence is in the range from 2.92 to 2.96 depending on temperature and magnetic field. With respect to the valence being 2.92 at 0 T and 2.93 at 33 T in 2 K, YbRh$$_2$$Si$$_2$$ is a valence fluctuation compound and does not reach the integer trivalent state at high magnetic field. These results endorse the conventional knowledge that the valence of Yb is very close to the integer value of 3+, decreases with decreasing temperature, and becomes closer to 3+ with increasing magnetic field.

JAEA Reports

Construction of a car-borne survey system for measurement of dose rates in air; KURAMA-II, and its application

Tsuda, Shuichi; Yoshida, Tadayoshi; Nakahara, Yukio; Sato, Tetsuro; Seki, Akiyuki; Matsuda, Norihiro; Ando, Masaki; Takemiya, Hiroshi; Tanigaki, Minoru*; Takamiya, Koichi*; et al.

JAEA-Technology 2013-037, 54 Pages, 2013/10

JAEA-Technology-2013-037.pdf:4.94MB

JAEA has been performing dose rate mapping in air using a car-borne survey system KURAMA-II. The KURAMA system is a GPS-aided mobile radiation monitoring system that has been newly developed by Kyoto University Research Reactor Institute in response to the nuclear disaster. The KURAMA system is composed of an energy-compensated scintillation survey meter for measuring dose rate, electric device for controlling both the dose rates and the position data from a GPS module, a computer server for processing and analyzing data from KURAMA, and client PCs for providing for end users. The KURAMA-II has been improved in small-packaging, durability, and automated data transmission. In consequence, dose rate mapping in wide area has become possible in shorter period of time. This report describes the construction of KURAMA-II, its application and a suggestion of how to manage a large number of KURAMA-II.

Journal Articles

Shallow donor level associated with hydrogen impurities in undoped BaTiO$$_3$$

Ito, Takashi; Higemoto, Wataru; Matsuda, Tatsuma*; Koda, Akihiro*; Shimomura, Koichiro*

Applied Physics Letters, 103(4), p.042905_1 - 042905_4, 2013/07

 Times Cited Count:10 Percentile:41.2(Physics, Applied)

74 (Records 1-20 displayed on this page)