Refine your search:     
Report No.
 - 
Search Results: Records 1-4 displayed on this page of 4
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Demonstration of long-pulse acceleration of high power positive ion beam with JT-60 positive ion source in Japan-Korea joint experiment

Kojima, Atsushi; Hanada, Masaya; Jeong, S. H.*; Bae, Y. S.*; Chang, D. H.*; Kim, T. S.*; Lee, K. W.*; Park, M.*; Jung, B. K.*; Mogaki, Kazuhiko; et al.

Fusion Engineering and Design, 102, p.81 - 87, 2016/01

 Times Cited Count:7 Percentile:47.74(Nuclear Science & Technology)

The long-pulse acceleration of the high-power positive ion beam has been demonstrated with the JT-60 positive ion source in the joint experiment among Japan Atomic Energy Agency (JAEA), Korea Atomic Energy Research Institute (KAERI) and National Fusion Research Institute (NFRI) under the collaboration program for the development of plasma heating and current drive systems. As a result of development of the operation techniques of the ion source and facilities of the neutral beam test stand in KAERI, 2 MW 100 s beam has been achieved for the first time. The achieved beam performance satisfies the JT-60SA requirement which is designed to be a 1.94 MW ion beam power from an ion source corresponding to total neutral beam power of 20 MW with 24 ion sources. Therefore, it was found that the JT-60 positive ion sources were applicable in the JT-60SA neutral beam injectors without further modification of the ion source and the accelerator. Moreover, because this ion source is planned to be a backup ion source for KSTAR, the operational region and characteristic has been clarified to apply to the KSTAR neutral beam injector.

Journal Articles

First neutral beam injection experiments on KSTAR tokamak

Jeong, S. H.*; Chang, D. H.*; Kim, T. S.*; In, S. R.*; Lee, K. W.*; Jin, J. T.*; Chang, D. S.*; Oh, B. H.*; Bae, Y. S.*; Kim, J. S.*; et al.

Review of Scientific Instruments, 83(2), p.02B102_1 - 02B102_3, 2012/02

 Times Cited Count:27 Percentile:70.75(Instruments & Instrumentation)

The first NB (neutral beam) injection system of the KSTAR tokamak was partially completed in 2010 with only 1/3 of its full design capability, and NB heating experiments were carried out during the 2010 KSTAR operation campaign. The ion source is composed of a JAEA bucket plasma generator and a KAERI large multi-aperture accelerator assembly. Before the beam injection experiments, characteristics of the ion source were investigated. A minimum beam divergence angle was 0.8 $$^{circ}$$. The ion species ratio was D$$^{+}$$:D$$_{2}$$$$^{+}$$:D$$_{3}$$$$^{+}$$=75:20:5. The arc efficiency is more than 1.0 A/kW. In the 2010 KSTAR campaign, the deuterium NB power of 0.7-1.5 MW was successfully injected into the KSTAR plasma with the beam energy of 70-90 keV. L-H transitions were observed within a wide range of beam powers relative to a threshold value. In every deuterium NB injection, a burst of D-D neutrons was recorded, and increases in the ion temperature and the plasma stored energy were found.

Journal Articles

Commissioning results of the KSTAR neutral beam system

Bae, Y. S.*; Park, Y. M.*; Kim, J. S.*; Han, W. S.*; Kwak, S. W.*; Chang, Y. B.*; Park, H. T.*; Song, N. H.*; Chang, D. H.*; Jeong, S. H.*; et al.

Proceedings of 23rd IAEA Fusion Energy Conference (FEC 2010) (CD-ROM), 9 Pages, 2011/03

The neutral beam injection (NBI) system is designed to provide the ion heating and current drive for the high performance operation and long pulse operation of the Korean Superconducting Tokamak Advanced Research (KSTAR). The KSTAR NBI consists of two beam lines. Each beam line contains three ion sources of which one ion source has been designed to deliver more than 2.5 MW of deuterium neutral beam power with maximum 120-keV beam energy. Consequently, the final goal of the KSTAR NBI system aims to inject more than 14 MW of deuterium beam power with the two beam lines. According to the planned NBI system, the first NBI system is to demonstrate the beam injection from one ion source into the KSTAR tokamak plasma in 2010 campaign including the system commissioning of each components and subsystems. In this paper, the construction and the commissioning of the first NBI system with one ion source is presented.

Journal Articles

Status and result of the KSTAR upgrade for the 2010's campaign

Yang, H. L.*; Kim, Y. S.*; Park, Y. M.*; Bae, Y. S.*; Kim, H. K.*; Kim, K. M.*; Lee, K. S.*; Kim, H. T.*; Bang, E. N.*; Joung, M.*; et al.

Proceedings of 23rd IAEA Fusion Energy Conference (FEC 2010) (CD-ROM), 8 Pages, 2011/03

Because the 2010 operation of Korea Superconducting Tokamak Advanced Research (KSTAR) mainly aims to achieve strongly elongated and diverted plasma, all the necessary hardware systems to provide an essential circumstance for the plasma shaping were newly installed and upgraded in 2010. In this paper, general configuration of the upgraded systems described earlier will be outlined. Moreover, several key performances and test results of the systems will be also reported in summary.

4 (Records 1-4 displayed on this page)
  • 1