Refine your search:     
Report No.
 - 
Search Results: Records 1-3 displayed on this page of 3
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Development of a real-time thermal neutron monitor and its clinical application

Ishikawa, Masayori*; Ono, Koji*; Matsumura, Akira*; Yamamoto, Tetsuya*; Hiratsuka, Junichi*; Miyatake, Shinichi*; Kato, Itsuro*; Sakurai, Yoshinori*; Kobayashi, Toru*; Kumada, Hiroaki; et al.

Proceedings of 12th International Congress on Neutron Capture Therapy (ICNCT-12), p.397 - 400, 2006/10

An ultraminiature thermal neutron monitor which was named SOF detector (Scintillator with Optical Fiber detector) had been developed for BNCT treatment. We had been experienced 15 clinical trials using SOF detector until the end of 2005, some measurements got good results, and some got unacceptable results. One reason of the unacceptable results was due to dislocation of the detector during treatment. This is because it is difficult to fix the SOF detector on patient's skin without strong sticker. To overcome this problem, a loop-type SOF probe was developed. By using the loop-type SOF detector, fixing on the patient's skin was much easier.

Journal Articles

Development of a wide-range paired scintillator with optical fiber neutron monitor for BNCT irradiation field study

Ishikawa, Masayori*; Kumada, Hiroaki; Yamamoto, Kazuyoshi; Kaneko, Junichi*; Bengua, G.*; Unesaki, Hironobu*; Sakurai, Yoshinori*; Tanaka, Kenichi*; Kosako, Toshiso*

Nuclear Instruments and Methods in Physics Research A, 551(2-3), p.448 - 457, 2005/10

 Times Cited Count:12 Percentile:61.7(Instruments & Instrumentation)

A wide range thermal neutron detector was developed based on the Scintillator with Optical Fiber (SOF) detector which has been previously used for thermal neutron monitoring during boron neutron capture therapy irradiation. With this new detector system we intended to address the issues of real-time thermal neutron flux measurement and the simultaneous measurement of a wide range of thermal neutron flux in a BNCT irradiation field which were difficult to implement with the gold wire activation method. A good agreement between the thermal neutron flux measured by the gold wire activation method and the paired SOF detector system was observed. However, measurements which would normally take a few days to perform with the gold wire activation method were obtained in just about 15 min using the SOF detector system. We also confirmed the dynamic range of linearity for the SOF detector system to be in the order of magnitude of 1e-4.

Oral presentation

Performance of miniature thermal neutron monitor for real-time dosimetry for boron neutron capture therapy

Kumada, Hiroaki; Ishikawa, Masayori*; Komeda, Masao; Nakamura, Takemi; Yamamoto, Kazuyoshi; Nakagawa, Yoshinobu*

no journal, , 

no abstracts in English

3 (Records 1-3 displayed on this page)