検索対象:     
報告書番号:
※ 半角英数字
 年 ~ 
 年
検索結果: 457 件中 1件目~20件目を表示

発表形式

Initialising ...

選択項目を絞り込む

掲載資料名

Initialising ...

発表会議名

Initialising ...

筆頭著者名

Initialising ...

キーワード

Initialising ...

使用言語

Initialising ...

発行年

Initialising ...

開催年

Initialising ...

選択した検索結果をダウンロード

論文

Chromium(VI) adsorption-reduction using a fibrous amidoxime-grafted adsorbent

林 菜月*; 松村 大樹; 保科 宏行*; 植木 悠二*; 辻 卓也; Chen, J.*; 瀬古 典明*

Separation and Purification Technology, 277, p.119536_1 - 119536_8, 2021/12

 被引用回数:8 パーセンタイル:54.59(Engineering, Chemical)

To develop a safe and simple method for the reduction of toxic chromium(VI) to the less harmful chromium(III), we proposed using radiation-induced graft polymerization. This method allows for any functional group to be introduced into conventional polymeric materials. Herein, we synthesized a fibrous adsorbent with amidoxime functional groups that have a high affinity for chromium, and investigated the changes in the chromium valence state over time in the amidoxime-grafted adsorbent. In situ X-ray absorption fine structure analysis revealed that most of the chromium(VI) was reduced to chromium(III) relatively early during the adsorption process, followed by gradual changes in the bonding structure of the amidoxime-chromium complex. It is expected to contribute to the development of practical technologies for wastewater treatment.

論文

Observation and evaluation of plastic collapse for double-notch pipe

鈴木 良祐*; 松原 雅昭*; 坂本 賢治*; 鈴木 将人*; 白石 泰祐*; 柳原 星児*; 伊沢 悟*; 若井 隆純

Experimental Techniques, 40(1), p.253 - 260, 2016/09

 被引用回数:0 パーセンタイル:0.03(Engineering, Mechanical)

軸方向に垂直な2つの90度貫通切欠きを持つオーステナイト系ステンレス鋼管の塑性崩壊挙動と強度を調べた。様々なノッチ間距離で二つのノッチ試験片を光塑性フィルムで覆った。試験片には、軸方向の引張荷重と曲げ荷重を任意に組み合わせた荷重を加えた。塑性崩壊挙動を調査するために、試験中に光塑性フリンジパターンの変化が観察された。塑性崩壊強度は、弾完全塑性体に基づくモデルを用いて評価した。実験的な塑性崩壊点での光塑性フリンジパターンは荷重履歴によって異なった。このことから、塑性崩壊挙動は荷重履歴に依存することがわかった。一方、塑性崩壊強度はノッチ間距離にはほとんど依存しなかった。実験的な塑性崩壊は、いくつかの純引張荷重試験でのみ理論塑性点に達する前に発生した。したがって、この研究で使用された弾完全塑性体に基づくモデル解析は、純粋な引張荷重を受けるステンレス鋼管の塑性崩壊には非保守的な推定を与える可能性がある。

論文

Corrigendum: Beam range estimation by measuring bremsstrahlung (2012 Phys. Med. Biol. 57 2843)

山口 充孝; 鳥飼 幸太*; 河地 有木; 島田 博文*; 佐藤 隆博; 長尾 悠人; 藤巻 秀; 国分 紀秀*; 渡辺 伸*; 高橋 忠幸*; et al.

Physics in Medicine & Biology, 61(9), p.3638 - 3644, 2016/05

 被引用回数:9 パーセンタイル:100(Engineering, Biomedical)

2012年にPhys. Med. Biol.誌にアクセプトされた原著論文("Beam range estimation by measuring bremsstrahlung", Phys. Med. Biol. 57 (2012) 2843)について、計算コードPHITSを用いた水中での炭素イオンの飛程に関して再計算したところ、飛程の値に間違いが見つかった。今後、制動輻射を用いたビームモニタリングに関する研究を行う上で無視することができない差異であるため、関連する記述内容も含め、訂正した原稿を投稿する。

論文

Particle induced X-ray emission-computed tomography analysis of an adsorbent for extraction chromatography

佐藤 隆博; 横山 彰人; 喜多村 茜; 大久保 猛; 石井 保行; 高畠 容子; 渡部 創; 駒 義和; 加田 渉*

Nuclear Instruments and Methods in Physics Research B, 371, p.419 - 423, 2016/03

 被引用回数:7 パーセンタイル:55.37(Instruments & Instrumentation)

The cross-sectional distribution of neodymium (Nd) simulating minor actinides (MA) in a minute globular adsorbent of less than 50 $$mu$$m in diameter was measured using PIXE (particle induced X-ray emission)-CT (computed tomography) with a 3-MeV proton microbeam for the investigation of residual MA in extraction chromatography of spent fast reactor fuel. The measurement area was 100 $$times$$ 100 $$mu$$m$$^2$$ corresponding to 128 $$times$$ 128 pixels of projection images. The adsorbent target was placed on an automatic rotation stage with 9$$^{circ}$$ step. Forty projections of the adsorbent were finally measured, and image reconstruction was carried out by the modified ML-EM (maximum likelihood expectation maximization) method. As a result, the cross-sectional distribution of Nd in the adsorbent was successfully observed, and it was first revealed that Nd remained in the region corresponding to internal cavities of the adsorbent even after an elution process. This fact implies that the internal structure of the adsorbent must be modified for the improvement of the recovery rate of MA.

論文

Medical application of radiohalogenated peptides; Synthesis and ${it in vitro}$ evaluation of F(${it p}$-$$^{131}$$I)KCCYSL for targeting HER2

佐々木 一郎; 渡辺 茂樹; 大島 康宏; 須郷 由美; 山田 圭一*; 花岡 宏史*; 石岡 典子

Peptide Science 2015, p.243 - 246, 2016/03

Radioisotope labeled peptides with high affinity to receptors overexpressing on the surface of tumor cells are promising for applications in nuclear medicine such as diagnostic radiography and radiotherapy. Radiohalogens such as $$^{131}$$I and $$^{211}$$At are useful for clinical imaging and therapeutic applications, and it can be introduced at the ${it para}$ position of phenylalanine residue via electrophilic destannylation. KCCYSL (Lys$$^{1}$$-Cys$$^{2}$$-Cys$$^{3}$$-Tyr$$^{4}$$-Ser$$^{5}$$-Leu$$^{6}$$) is a hexapeptide containing disulfide bond. Previous study revealed that KCCYSL has potential as tumor imaging and therapeutic agent targeting tumor cells overexpressing the human epidermal growth factor receptor type 2 (HER2). In this study, we report synthesis and ${it in vitro}$ evaluation of radiohalogenated KCCYSL derivatives. Precursor peptides, Boc-F(${it p}$-SnBu$$_{3}$$)K(Boc)C(Trt)C(Trt)Y($$^{t}$$Bu)S($$^{t}$$Bu)L-OH and Boc-F(${it p}$-SnBu$$_{3}$$)GS($$^{t}$$Bu)GK(Boc)C(Trt)C(Trt)Y($$^{t}$$Bu)S($$^{t}$$Bu)L-OH, were synthesized by the Fmoc solid phase peptide synthesis. Then, precursor peptides were radioiodinated via electrophilic destannylation, and they were deprotected to obtain F(${it p}$-$$^{131}$$I)KCCYSL and F(${it p}$-$$^{131}$$I)GSGKCCYSL in radiochemical yield 15% and 17%, respectively. ${it In vitro}$ assays of the radioiodinated peptides for HER2 and stability in serum are being undertaken.

論文

Detection of a gas region in a human body across a therapeutic carbon beam by measuring low-energy photons

山口 充孝; 長尾 悠人; 河地 有木; 佐藤 隆博; 藤巻 秀; 神谷 富裕; 鳥飼 幸太*; 島田 博文*; 菅井 裕之*; 酒井 真理*; et al.

International Journal of PIXE, 26(1&2), p.61 - 72, 2016/00

炭素線治療中にその軌道上の生体組織内で発生する局所的密度減少は、ブラッグピーク位置のシフトを引き起こし、誤照射の原因となる。この密度減少を炭素線照射中に確認できれば、誤照射を軽減する対策が立てられる。そこで、重粒子線治療で発生する二次電子による制動輻射のうち、発生量が多く効率的測定が可能な低エネルギー光子(63-68keV)による生体内の局所的密度減少の検出方法を開発している。今回、空気間隙による密度減少の存在の検出が可能かどうかをPHITSコードを用いたモンテカルロシミュレーションにより次のように評価した。ビーム軸方向の長さが50mm、奥行き200mm、高さ200mmのアクリルブロック2個を、ビーム軸方向に10mmの間隙を設けて設置した。また、検出器として、幅2.4mmのスリットを持つ鉛製コリメータとテルル化カドミウム製の検出素子を組み合わせた。炭素線を照射した際にビーム軸に対して垂直方向に放出される63-68keVの光子を検出したところ、その検出量に明らかな増減が確認できた。この結果は、間隙の存在を十分検出することが可能であることを示す。

論文

Collapse evaluation of double notched stainless pipes subjected to combined tension and bending

鈴木 良祐*; 松原 雅昭*; 柳原 星児*; 森尻 貢*; 大森 敦*; 若井 隆純

Procedia Materials Science, 12, p.24 - 29, 2016/00

 被引用回数:2 パーセンタイル:74.48

二つの亀裂を有するステンレス鋼管の構造健全性評価を単純化するため、引張と曲げを組み合わせた非対称な二つの切欠きを有する管の塑性崩壊応力を調べた。非対称の二つの切欠きを有する管の実験的塑性崩壊応力を、単一切欠きを有する管の理論的塑性崩壊応力と比較した。実験的塑性崩壊点は理論的崩壊限界曲線よりも大きかった。単一の切欠きを有する管の理論的塑性崩壊応力を使用して、引張と曲げを組み合わせた非対称の二つの亀裂を有するステンレス鋼管の健全性を簡単かつ控えめに評価することができることを示した。

論文

New application of NV centers in CVD diamonds as a fluorescent nuclear track detector

小野田 忍; 春山 盛善; 寺地 徳之*; 磯谷 順一*; 加田 渉*; 花泉 修*; 大島 武

Physica Status Solidi (A), 212(11), p.2641 - 2644, 2015/11

 被引用回数:10 パーセンタイル:45.17(Materials Science, Multidisciplinary)

Nitrogen-vacancy (NV) center in diamond is a luminescent point defect with applications of quantum computation and atomic scale sensors. One of the most important features of NV center is high emission rate. This enables single NV centers to be detected using a confocal laser scanning microscope. In this study, we propose a new application of NV centers as a single ion track detector. We perform 490 MeV Os ion irradiation to diamond grown by chemical vapor deposition (CVD) technique. After high temperature annealing at 1000 $$^{circ}$$C, the ion track is able to be visualized by using confocal laser scanning microscope. In short, we have successfully detected ion track in diamonds.

論文

NV centers in diamond used for detection of single ion track

春山 盛善; 小野田 忍; 加田 渉*; 寺地 徳之*; 磯谷 順一*; 大島 武; 花泉 修*

Proceedings of 11th International Workshop on Radiation Effects on Semiconductor Devices for Space Applications (RASEDA-11) (Internet), p.184 - 187, 2015/11

We propose that diamond can be utilized as a new Fluorescent Nuclear Track Detector (FNTD) material. For this aim, we focus on Nitrogen Vacancy (NV) centers in diamond. One of the most important features of a NV center is a high emission rate, which enable us to observe single NV center. After high energy ion irradiation and subsequent annealing, we successfully observe Os ion tracks in various diamonds containing dense nitrogen impurity. However, Os ion track cannot be observed from diamond without nitrogen impurity. We found that the optimization of nitrogen impurity is a key issue for developing high sensitive FNTD based on diamond.

論文

Development of a widely usable amino acid tracer; $$^{76}$$Br-$$alpha$$-methyl-phenylalanine for tumor PET imaging

花岡 宏史*; 大島 康宏; 鈴木 結利花*; 山口 藍子*; 渡辺 茂樹; 上原 知也*; 永森 收志*; 金井 好克*; 石岡 典子; 対馬 義人*; et al.

Journal of Nuclear Medicine, 56(5), p.791 - 797, 2015/05

 被引用回数:17 パーセンタイル:62.87(Radiology, Nuclear Medicine & Medical Imaging)

Radiolabeled amino acids are superior PET tracers for imaging of malignant tumors, and amino acids labeled with $$^{76}$$Br, an attractive positron emitter due to its relatively long half-life (t$$_{1/2}$$=16.2 h), could potentially be widely usable tumor imaging tracer. In this study, in consideration of stability and tumor specificity, 2-$$^{76}$$Br-bromo-$$alpha$$-methyl-L-phenylalanine (2-$$^{76}$$Br-BAMP) and 4-$$^{76}$$Br-bromo-$$alpha$$-methyl-L-phenylalanine (4-$$^{76}$$Br-BAMP) were designed and their potential as a tumor imaging agent was evaluated. No-carrier-added $$^{76}$$Br and $$^{77}$$Br, the latter of which is suitable radiobromine for basic studies due to its longer half-life (t$$_{1/2}$$ = 57.1 h), were produced. Both $$^{77}$$Br-BAMPs were stable in the plasma and in the murine body. In biodistribution studies, 2-$$^{77}$$Br-BAMP showed more rapid blood clearance and lower renal accumulation than did 4-$$^{77}$$Br-BAMP. More than 90% of injected radioactivity was excreted in the urine by 6 h post-injection of 2-$$^{77}$$Br-BAMP. High tumor accumulation of 2-$$^{77}$$Br-BAMP was observed in tumor-bearing mice and PET imaging with 2-$$^{76}$$Br-BAMP enabled clear visualization of the tumor. These findings suggest that 2-$$^{76}$$Br-BAMP would constitute a potential new PET tracer for tumor imaging and may eventually enable the wider use of amino acid tracers.

論文

Fabrication of microstructures embedded in SC-CVD diamond with a focused proton microbeam

加田 渉*; 神林 佑哉*; 三浦 健太*; 猿谷 良太*; 久保田 篤志*; 佐藤 隆博; 江夏 昌志; 神谷 富裕; 花泉 修*

Key Engineering Materials, 643, p.15 - 19, 2015/05

Micro-processing procedures have been extensively studied using a Proton Beam Writing (PBW) technique in order to fabricate two or three dimensional microscopic patterns in single-crystal chemical vapor deposition (SC-CVD) diamonds. In this study, various microscopic patterns were drawn on SC-CVD diamonds (3.0 mm $$times$$ 3.0 mm $$times$$ 0.5 mm IIa single-crystal) at various fluences with PBW using 0.75 and 3 MeV proton beams. The beam conditions of PBW other than the beam energy were as follows; a beam size of 1 $$mu$$m, a scanning area of 800 $$mu$$m $$times$$ 800 $$mu$$m and beam current of up to 100 pA. From the result of the observations based on the optical and electrical modification of SC-CVD, the microscopic patterns were fabricated in the diamonds by the micro-processing procedure varying fluence and beam energy. This result demonstrated that the micro-processing procedure with PBW enables us to fabricate the two or three dimensional microscopic patterns, which are optically and electrically modified, in SC-CVD diamonds by optimizing fluence and beam energy.

論文

Development of microbeam technology to expand applications at TIARA

神谷 富裕; 佐藤 隆博; 江夏 昌志; 加田 渉*

Nuclear Instruments and Methods in Physics Research B, 348, p.4 - 7, 2015/04

 被引用回数:5 パーセンタイル:40.2(Instruments & Instrumentation)

Ion microbeam technology has been progressed at TIARA, aiming at expanding its applications. Micro-analyses of micro-PIGE and micro-IBIL (Ion Beam Induced Luminescence) based on the micro-PIXE have expanded a region of their analyzing objects. Micro-fabrication by mask-less irradiation on materials based on the technique of PBW (Proton Beam Writing) without etching processes was applied for optical, magnetic or other novel micro-devices fabrication. Single-ion-hitting technique which was required for reliable irradiation to biological cells or semiconductor devices progressed so that each ion hit could be monitored in real time using an efficient scintillator and a high sensitivity camera. Development of a thin film type particle detector was newly started for the same purpose. This paper summarizes the latest progress of the ion microbeam technology and applications at TIARA, and discusses their future prospects.

論文

Development of diagnostic method for deep levels in semiconductors using charge induced by heavy ion microbeams

加田 渉*; 神林 佑哉*; 岩本 直也*; 小野田 忍; 牧野 高紘; 江夏 昌志; 神谷 富裕; 星乃 紀博*; 土田 秀一*; 児島 一聡*; et al.

Nuclear Instruments and Methods in Physics Research B, 348, p.240 - 245, 2015/04

 被引用回数:4 パーセンタイル:33.51(Instruments & Instrumentation)

Deep level defects in semiconductors act as carrier traps Deep Level Transient Spectroscopy (DLTS) is known as one of the most famous techniques to investigate deep levels. However, DLTS does not well work for samples with high resistivity. To overcome this issue, DLTS using charge generated by ion incidence was proposed. Recently, we developed a deep level evaluation system based on Charge Transient Spectroscopy using alpha particles from $$^{241}$$Am (Alpha Particle Charge Transient Spectroscopy: APQTS) and reported the effect of deep levels in 6H SiC pn diodes generated by electron irradiation on the characteristics as particle detectors. In this study, we report the development of Charge Transient Spectroscopy using Heavy Ion Microbeams (HIQTS). The HIQTS can detect deep levels with micron meter spatial resolution since microbeams are applied. Thus, we can clarify the relationship between deep levels and device characteristics with micron meter resolution. When a 6H-SiC pn diode was irradiated with 12 MeV-oxygen (O) ions at 4$$times$$10$$^{9}$$ and 8$$times$$10$$^{9}$$ /cm$$^{2}$$, the charge collection efficiency (CCE) decreased to 71 and 52%, respectively. HIQTS signals obtained from those damaged regions using 15 MeV-O microbeams increased at measurement temperature ranges above 350 K, and the signals are larger with increasing 12 MeV-O ion fluence.

論文

Development of embedded Mach-Zehnder optical waveguide structures in polydimethylsiloxane thin films by proton beam writing

加田 渉*; 三浦 健太*; 加藤 聖*; 猿谷 良太*; 久保田 篤志*; 佐藤 隆博; 江夏 昌志; 石井 保行; 神谷 富裕; 西川 宏之*; et al.

Nuclear Instruments and Methods in Physics Research B, 348, p.218 - 222, 2015/04

 被引用回数:6 パーセンタイル:46.16(Instruments & Instrumentation)

The Mach-Zehnder (MZ) optical structures were previously fabricated in a Poly-methyl-methacrylate (PMMA) thin film by Proton Beam Writing (PBW). The enhancement of optical transmittance in the structures is, however, required for industrial use. In this study, the MZ optical waveguides have been fabricated in a poly-dimethyl-siloxane (PDMS) thin film which has the higher optical permeability. The PDMS films were spin-coated on a silicon wafer (40 $$times$$ 20 $$times$$ 0.5 mm$$^3$$) with a thickness of approximately 30 $$mu$$m. The MZ waveguides were drawn by a 750 keV proton microbeam of 1$$mu$$m in diameter having the penetration depth of 18 $$mu$$m with fluence of 40-100 nC/mm$$^2$$. The beam writing was carried out combining an electric scanner and a mechanical sample-stage. The observation of the single-mode light propagation of 1.55 $$mu$$m fiber-laser in the MZ waveguides indicated that the optical transmittance have been successfully enhanced using PDMS.

論文

Size and dopant-concentration dependence of photoluminescence properties of ion-implanted phosphorus- and boron-codoped Si nanocrystals

中村 俊博*; 安達 定雄*; 藤井 稔*; 杉本 泰*; 三浦 健太*; 山本 春也

Physical Review B, 91(16), p.165424_1 - 165424_8, 2015/04

 被引用回数:17 パーセンタイル:58.8(Materials Science, Multidisciplinary)

半導体ナノ結晶は量子閉じ込め効果などサイズに起因したユニークな物性を示すことから、その不純物ドーピングによる新たな電気的及び光学的特性の発現が期待される。本研究では、発光素子への応用が期待されているシリコン(Si)ナノ結晶を対象に、イオン注入法によりリン(P)とホウ素(B)を共ドープし、フォトルミネッセンス(PL)特性のサイズ(平均値: 3.5, 4.4, 5.2nm)、ドープ量(0.1-4.5$$times$$10$$^{16}$$cm$$^{-2}$$)依存性を調べた。その結果、Siナノ結晶のサイズや不純物のドープ量が増加するとともに、発光ピークの低エネルギー側へのシフトが観測された。したがって、このピークはバンド間遷移による発光と同定でき、サイズやドープ量の変化によりバンドギャップが減少していると考えることができる。このようなバンド間遷移に加え、イオン注入に伴い形成された欠陥を介した発光も見出し、Siナノ結晶における精密な発光特性制御の可能性を示した。

論文

LET dependency of human normal dermal cells survival in carbon ion irradiation

吉田 由香里*; 溝端 健亮*; 松村 彰彦*; 磯野 真由*; 八高 知子*; 中野 隆史*; 舟山 知夫; 小林 泰彦; 金井 達明*

JAEA-Review 2014-050, JAEA Takasaki Annual Report 2013, P. 81, 2015/03

日本の炭素線治療において臨床線量を決定するために用いられているclinical RBE (cRBE)はexperimental RBE (eRBE)にscaling factorをかけたものである。eRBEはhuman salivary gland(HSG)細胞を用いたコロニー形成法によりlinear-quadratic(LQ)モデルで得られた$$alpha$$値および$$beta$$値から求められた各LETにおけるRBEが採用されており、これが全ての患者(すなわちすべての細胞および組織)における炭素線治療計画に反映されている。しかしながら、RBEは線量,線量率,細胞や組織の種類、エンドポイント、酸素化の程度などにより異なる。そこで、群馬大学重粒子線照射施設(GHMC)のLET 13$$sim$$80keV/$$mu$$m、および原子力機構TIARAのLET 108$$sim$$158keV/$$mu$$mの炭素線を用い、その線量分布を評価すると共に、ヒト正常皮膚細胞への照射を行い、得られたRBE値について過去のHSG細胞の結果と比較・解析した。

論文

NHEJ repair rather than HR repair is the primary function to target to enhance radiosensitization at high LET values

高橋 昭久*; 久保 誠*; 五十嵐 千恵*; 吉田 由香里*; 舟山 知夫; 小林 泰彦; 中野 隆史*

JAEA-Review 2014-050, JAEA Takasaki Annual Report 2013, P. 82, 2015/03

放射線によるDNA二本鎖切断(DSB)は致命的であるが、相同組換え(HR)および非相同末端結合(NHEJ)によって修復される。そこで、我々は殺細胞効果におよぼすDNA二本鎖切断修復のLET依存性を明らかにすることを目的に、DNA二本鎖切断修復の異なる細胞における高LET放射線感受性をコロニー形成法で評価した。その結果、NHEJがはたらく野生型細胞とHR欠損細胞は108keV/$$mu$$mの炭素線で高いRBE値を示した。SER値はHR修復欠損ではLETの違いによらず約2と一定だったのに対して、NHEJ修復欠損ではX線に比べて、HR修復欠損よりも高い値を示した。

論文

$$gamma$$線照射によるシルク細胞培養基材の力学特性の変化

河原 豊*; 関口 孝弘*; 西川 幸宏*; 長澤 尚胤

日本シルク学会誌, 23, p.67 - 69, 2015/03

蚕の液状絹を原料として凍結乾燥法により作製した絹エアロゲルは、再生医療用に利用可能な3次元構造を有するシルク細胞培養基材としての利用が期待されている。絹エアロゲルを生体内外で細胞培養する際に、その圧縮強度は重要な物性の一つであることから、絹エアロゲル中の水溶性セリシンの架橋効果を調べた。未処理とセリシンを除去処理した試料に$$gamma$$線を10, 25, 50kGy照射し、照射前後の絹エアロゲルの圧縮強度について評価した。セリシン除去処理した絹エアロゲルは線量の増加とともに圧縮強度が低下したが、未処理絹エアロゲルでは逆に圧縮強度が増加した。50kGy照射した場合、未処理絹エアロゲルの圧縮強度は、未照射の2倍の0.3MPaになった。$$gamma$$線照射によりセリシンに架橋構造が導入され絹エアロゲルの圧縮強度を改善できることから新規シルク細胞培養基材を作製できる手がかりを得た。

論文

Exploring of peptides with affinity to HER2 from random peptide libraries using radioisotope; Random hexapeptide libraries with fixed amino acid sequence at 1 and 2 positions

佐々木 一郎; 花岡 宏史*; 山田 圭一*; 渡辺 茂樹; 須郷 由美; 大島 康宏; 鈴木 博元; 石岡 典子

Peptide Science 2014, p.257 - 260, 2015/03

We have sought to establish drug discovery system using radioisotope (RI) labeled peptides which have high affinity to target proteins overexpressed in cancers. Of the target proteins, we chose the human epidermal growth factor receptor type 2 (HER2), a membrane protein overexpressed in various cancers to evaluate the drug discovery system. Three series of random hexapeptide libraries introduced a radioiodinated D-tyrosine (y(3-$$^{131}$$I)) to $$N$$-terminal were designed and binding assay with HER2-expressed cell lines were conducted in this study. First, we synthesized a series of random hexapeptide libraries with fixed amino acid sequence at 1 and 2 positions, y(3-$$^{131}$$I)X$$^{1}$$X$$^{2}$$X$$^{3}$$X$$^{4}$$X$$^{5}$$X$$^{6}$$. Non-radioactive random peptide libraries, yXXXXXX, were prepared by Fmoc-SPPS with an automatic peptide synthesizer. Radioiodinated y(3-$$^{131}$$I)XXXXXX were subsequently synthesized in 30-50% radiochemical yield. Binding assay using HER2-overexpressed cell line showed that high affinity (38-50% dose, n=6) was obtained with yIIXXXX, while other random peptide libraries were yielded low affinity (approximately 1% dose), which indicated that the system using RI labeled random peptide libraries have potential to discover peptide drug for cancer therapy. Preparation of other random hexapeptide libraries are being undertaken.

論文

Production of highly purified no-carrier-added $$^{177}$$Lu for radioimmunotherapy

渡辺 智; 橋本 和幸; 渡辺 茂樹; 飯田 靖彦*; 花岡 宏史*; 遠藤 啓吾*; 石岡 典子

Journal of Radioanalytical and Nuclear Chemistry, 303(1), p.935 - 940, 2015/01

 被引用回数:10 パーセンタイル:64.82(Chemistry, Analytical)

No-carrier-added $$^{177}$$Lu produced via the $$^{176}$$Yb(n, $$gamma$$) $$^{177}$$Yb $$rightarrow$$$$^{177}$$Lu process was separated from the macroscopic amounts of the Yb target using reversed-phase ion-pair liquid chromatography. To produce a highly purified $$^{177}$$Lu solution capable of labeling antibodies, the metallic impurities were removed using cation, chelating ion, and anion exchange columns. After the elimination of metallic impurities, the concentrations of Ca, Fe, and Zn were reduced from 87, 340, and 77 ppb to 13, 18, and 9 ppb, respectively. Consequently, the labeling yield of the $$^{177}$$Lu -labeled antibody increased from less than 5% to 88%.

457 件中 1件目~20件目を表示