Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 20
  • 1

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

JAEA Reports

Application of imaging plate to the radiation protection in the MOX fuel fabrication facility, 2; The effect of changing exposure conditions and analysis conditions

Sagawa, Naoki; Izaki, Kenji; Mizuniwa, Harumi*

JAEA-Technology 2013-029, 28 Pages, 2013/11

JAEA-Technology-2013-029.pdf:3.35MB

Developed in the Mixed Oxide fuel fabrication facility, Basic handling of IP, analysis method, detection of Pu and radioactivity quantification. These are the conditions that the exposure conditions and the analysis condition are constant. However, in the case of Contamination has occurred in the workplace, contaminated samples are not only Pu. It may contain a Pb or RnTn. Then, if other work is being carried out in a room that is the operation of IP, it's difficult to darken the room. PSL is reduced when light hits the IP. In this study, we have investigated in order to upgrade radiation protection, in the case of Containing the Pb or PSL reduction by light. Additionally, regarding change of analysis condition, the analysis method was examined when the resolution was changed to 50 micro, 100 micro and 200 micro.

Journal Articles

An Autoradiographical method using an imaging plate for the analyses of plutonium contamination in a plutonium handling facility

Takasaki, Koji; Sagawa, Naoki; Kurosawa, Shigeyuki; Mizuniwa, Harumi

Journal of Nuclear Science and Technology, 48(6), p.911 - 918, 2011/06

 Times Cited Count:12 Percentile:66.68(Nuclear Science & Technology)

An autoradiographical method using an imaging plate (IP) was developed to analyze the plutonium contamination in the plutonium handling facility and was applied to the monitoring of the workplace in a practical uranium-plutonium mixed oxide (MOX) fuel fabrication facility. A good relationship between the photo stimulated luminescence (PSL) intensities of IP and radioactivities measured by a radiation counter was obtained by the least-square fitting, taking the fading effect into consideration. The $$alpha$$-radioactivities of plutonium contamination were derived from the PSL image in this IP method, and their relative errors were evaluated from exposure time.

JAEA Reports

Application of imaging plate to the radiation protection in the MOX fuel fabrication facility

Sagawa, Naoki; Yamazaki, Takumi; Kurosawa, Shigeyuki*; Izaki, Kenji; Mizuniwa, Harumi; Takasaki, Koji

JAEA-Technology 2010-051, 35 Pages, 2011/03

JAEA-Technology-2010-051.pdf:1.83MB

The image analysis method using a imaging plate (IP) is recent technique, and this method can get the information of radioactivity distribution by the unit of Photo Simulated Luminescence (PSL). We have investigated the PSL images obtained by measuring some plutonium samples which are radiation protection samples in order to apply imaging plate to the radiation protection at the MOX fuel facility. Plutonium spots were extracted from the PSL image extracted by the threshold, in which about 99% of the back ground was excluded, and identified by the additional requirement that the spot size is more than 40 pixels. The average background is subtracted from PSL strength of the spot area identified as Pu, and the radioactivity of the Pu spot was evaluated by multiplying the conversion calculation that is in consideration of fading.

JAEA Reports

Study on pulse height discrimination of alpha-ray using ZnS(Ag) scintillation detector; Adaptability to contamination monitoring equipments

Izaki, Kenji; Ino, Kazuo*; Mizuniwa, Harumi

JAEA-Research 2008-107, 46 Pages, 2009/03

JAEA-Research-2008-107.pdf:3.81MB

The contamination control has been carried out by alpha-ray measurement in facilities where handling plutonium like the MOX fuel manufacturing facility and the reprocessing facility, etc. In the case of alpha-ray measurement, it is necessary to consider the influence of radon progeny that is natural radionuclide. The influence of radon progeny has been decreased by pulse height discrimination technique using the semiconductor detector as needed. However, the semiconductor detector has potentially significant problems such as the durability and noise susceptibility. Therefore the accuracy of pulse height discrimination by the ZnS(Ag) scintillation detector was confirmed as alternative to the semiconductor detector. This report shows the accuracy of pulse height discrimination technique using the ZnS(Ag) scintillation detector and evaluates the adaptability to contamination control equipments.

JAEA Reports

Examination of fabric of protective clothing suitable for sweltering radiation work; Influence on survey of contamination (MOX) in wet condition with sweat

Horikoshi, Yoshinori; Nemoto, Norio; Kurosawa, Shigeyuki*; Takasaki, Koji; Mizuniwa, Harumi

JAEA-Testing 2008-003, 29 Pages, 2008/04

JAEA-Testing-2008-003.pdf:1.65MB

In the Plutonium Fuel Technical Development Center, protective clothing suitable for sweltering radiation work was examined. Since it worried about the influence of wet protective clothing with sweat on detection of MOX powder contamination, Detection situations, the diffusion of contamination, and the osmosis and penetrability to wet protective clothing were examined about the present fabric and other new fabrics. As a result of examination, it was confirmed that the influence of detection on alpha ray in the wet condition of new fabrics was smaller than the current fabric. This report compiled the result of examination and points in the fabric selection suitable for protective clothing.

JAEA Reports

Development of image-analysis method of plutonium samples by imaging plate; Measurement of plutonium samples in mixed oxide fuel fabrication facility

Takasaki, Koji; Sagawa, Naoki; Kurosawa, Shigeyuki*; Shioya, Satoshi; Suzuki, Kazunori; Horikoshi, Yoshinori; Mizuniwa, Harumi

JAEA-Technology 2008-028, 73 Pages, 2008/03

JAEA-Technology-2008-028.pdf:5.88MB

Recently, an imaging plate (IP) was developed. Pu analysis by an IP was studied in the JAEA Cooperative Research Scheme on the Nuclear Fuel Cycle, and the availability about detection of Pu and discrimination with radon progenies was shown. In order to apply these results to the radiation control, this research aims at evaluation of radioactivity, discrimination with radon progenies, and evaluation of AMAD by an IP. In the conventional autoradiography (ARG) by a ZnS and Polaroid film, Contamination of Pu can only be grasped by viewing. Since the digital data of the radiation and location is obtained by an IP, Pu can be detected quantitatively and radioactivity can be evaluated. As a result of this research, the image of alpha emitter on an IP is the same as that of the conventional ARG, and can be applied also to the ARG of beta and $$gamma$$ emitter. In measurement of Pu, the function of Image J (image-analysis software) was very available. Pu radioactivity was evaluated by an IP.

Journal Articles

None

; Miyabe, Kenjiro; ; Akiyama, Kiyomitsu;

Hoken Butsuri, 37(3), 222- Pages, 2002/09

None

Journal Articles

None

; Miyabe, Kenjiro;

Hoken Butsuri, 35(2), p.238 - 243, 2000/06

None

JAEA Reports

None

Miyabe, Kenjiro; ; ; ; Akiyama, Kiyomitsu;

JNC TN8410 99-054, 175 Pages, 1999/10

JNC-TN8410-99-054.pdf:10.06MB

None

JAEA Reports

None

Ishida, Junichiro; ; ; ; Akiyama, Kiyomitsu; ; Tanaka, Hiroshi; ; Kurimata, Tomoyuki*; Ozawa, Tomoyasu*; et al.

JNC TN8410 98-002, 112 Pages, 1998/09

JNC-TN8410-98-002.pdf:6.27MB

None

JAEA Reports

None

Ishida, Junichiro; ; ; ; ; Tanaka, Hiroshi;

PNC TN8410 98-061, 87 Pages, 1997/10

PNC-TN8410-98-061.pdf:4.72MB

None

Journal Articles

None

Donen Giho, (78), p.15 - 17, 1991/06

Journal Articles

None

Kobayashi, Hirohide; Kanamori, Masashi; Noda, Kimio; Izaki, Kenji; Miyabe, Kenjiro;

Nihon Genshiryoku Gakkai-Shi, , 

None

Oral presentation

Development of image-analysis method of plutonium samples by imaging plate

Mizuniwa, Harumi; Takasaki, Koji; Horikoshi, Yoshinori; Suzuki, Kazunori; Shioya, Satoshi; Sagawa, Naoki; Kurosawa, Shigeyuki*

no journal, , 

no abstracts in English

Oral presentation

Suggestion for design of ventilation system based on trend analysis of dust monitoring data under normal conditions

Yamazaki, Takumi; Izaki, Kenji; Mizuniwa, Harumi

no journal, , 

no abstracts in English

Oral presentation

Application of imaging plate to the radiation protection in the MOX fuel fabrication facility

Sagawa, Naoki; Kurosawa, Shigeyuki*; Takasaki, Koji; Mizuniwa, Harumi

no journal, , 

no abstracts in English

Oral presentation

A Trial the distribution measurement of the alpha ray radioactivity using flat panel type PMT

Yamazaki, Takumi; Sagawa, Naoki; Izaki, Kenji; Mizuniwa, Harumi

no journal, , 

no abstracts in English

Oral presentation

Examination of autoradiography with digital camera

Sagawa, Naoki; Odano, Takayuki*; Morifuji, Masayuki; Izaki, Kenji; Mizuniwa, Harumi

no journal, , 

no abstracts in English

Oral presentation

Measurements and simulations of response of silicon semiconductor detector produced by incident neutron

Morishita, Yuki; Sagawa, Naoki; Tsubaki, Hirohiko; Izaki, Kenji; Mizuniwa, Harumi

no journal, , 

no abstracts in English

Oral presentation

Investigation on plutonium discrimination by function of energy and position detection

Morishita, Yuki; Izaki, Kenji; Mizuniwa, Harumi; Kaneko, Junichi*; Shimaoka, Takehiro*; Tsubota, Yoichi*; Higuchi, Mikio*; Toi, Kohei*

no journal, , 

no abstracts in English

20 (Records 1-20 displayed on this page)
  • 1