Basic test on sodium fire protection systems (III); Simulation Test, Run-B3 of a design basis sodium leak from the Monju IHTS

Himeno, Yoshiaki; not registered  ; Kawada, Koji*; Kawabe, Ryuhei*; not registered; not registered; Miyaguchi, Kimihide

Test of sodium fires in an auxiliary building of the fast reactor has been conducted by use of a test rig in which reduced scale models of a sodium pipe, a floor liner, a sodium drain pipe, and a smothering tank were installed to simulate the configuration of fire mitigation systems in the reactor. In the test, a 150kg sodium at temperature of 505 $$^{circ}$$C was spilled from the model sodium pipe at flow rate of 1 $$ell$$/sec for 3 minutes. Then a whole accident sequence that starts from a sodium spill and ends at a self-extiguishment of fire within the smothering tank was studied. From the test results obtained and through their analysis, the following conclusions were drawn. (1)A whole sodium leak and fires accident sequence proceeded as expected in the Monju design, i,e., a spilled sodium was smoothly drained into the smothering tank via the floor liner and the drain pipe, then sodium fire was self-extinguished in the smothering tank. (2)In regard to the model sodium pipe, failures of the thermal insulation jackets due to sodium corrosion and due to generated sodium combustion heat are not found. The thermal insulation jackets kept its original geometries and functioned propely as a barrier to prevent the dispersion of spilled sodium into the atmosphere during the test. No flow blockage of a spilled sodium occured both on the floor Liner and in the drain pipe. Combustion heat of mixed fires (a columnar fire and a pool fire) that occured within an accident cell of the test rig was determined to be 1.6 times of that of a pool fire. This value is not so large as expected and indicates that the mild fires proceeds during the test. (3)With the smothering tank, temperatures data of sodium, steel liner, perlite concrete, and structural concrete were obtained. The data of concretes indicated that the structural concrete was not heated so high as to interfere its structural integrity. A total water released from the concretes per unit surface area of the liner ...

Acecsses

:

- Accesses

InCites™

:

Altmetrics

:

[CLARIVATE ANALYTICS], [WEB OF SCIENCE], [HIGHLY CITED PAPER & CUP LOGO] and [HOT PAPER & FIRE LOGO] are trademarks of Clarivate Analytics, and/or its affiliated company or companies, and used herein by permission and/or license.