Refine your search:     
Report No.
 - 

Development of a radio-proof control valve and a relief valve; Driving test under the irradiation

Makida, Yasuhiro*; Ohata, Hirokatsu*; Okamura, Takahiro*; Ogitsu, Toru*; Nakamoto, Tatsushi*; Kimura, Nobuhiro*; Idesaki, Akira; Gokan, Mayo*; Morishita, Norio

A Superconducting magnet system will be adopted for the J-PARC neutrino beam line. Since the magnet system will be exposed to high radiation field, the radiation resistance of a cryostat is very important. We have developed radio-proof control valve and relief valve by selection of some parts and separation of the positioner. In this work, the developed valves were worked under the $$gamma$$ ray irradiation, and it was found that the valves show the radiation resistance above 1 MGy.