検索対象:     
報告書番号:
※ 半角英数字
 年 ~ 
 年

Real-time beam profile measurement system using fluorescent screens

蛍光板を用いたリアルタイムビームプロファイル計測システム

湯山 貴裕; 百合 庸介; 石坂 知久; 石堀 郁夫; 奥村 進

Yuyama, Takahiro; Yuri, Yosuke; Ishizaka, Tomohisa; Ishibori, Ikuo; Okumura, Susumu

A real-time beam profile measurement system was developed for efficient operation of a uniform-beam tuning by multipole magnets. This system consists of CCD cameras, two fluorescent screens (Gd$$_{2}$$O$$_{2}$$S:Tb and Al$$_{2}$$O$$_{3}$$:Cr) and an image analysis program based on LabVIEW. Available fluence rate and relative transverse intensity distribution could be obtained from the fluorescence in this system. The intensity distribution measured by the system agreed well with the relative intensity distribution obtained with a Gafchromic radiochromic film.

Access

:

- Accesses

InCites™

:

Altmetrics

:

[CLARIVATE ANALYTICS], [WEB OF SCIENCE], [HIGHLY CITED PAPER & CUP LOGO] and [HOT PAPER & FIRE LOGO] are trademarks of Clarivate Analytics, and/or its affiliated company or companies, and used herein by permission and/or license.