Sensitivity and uncertainty analysis for a minor-actinide transmuter with JENDL-4.0

JENDL-4.0を用いたMA核変換システムの感度・不確かさ解析

岩元 大樹   ; 西原 健司  ; 菅原 隆徳  ; 辻本 和文 

Iwamoto, Hiroki; Nishihara, Kenji; Sugawara, Takanori; Tsujimoto, Kazufumi

A sensitivity and uncertainty analysis was performed for the minor-actinide transmuter proposed by the Japan Atomic Energy Agency with JENDL-4.0. Analysis with sensitivity coefficients and the JENDL-4.0 covariance data showed that the covariances of the capture cross sections and fission-related parameters of MAs and Pu isotopes have considerable impact on the uncertainties for the ADS, and covariances of the inelastic scattering cross section of LBE materials significantly affect the uncertainty of coolant-void reactivity.